Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L1 | Accepted-AOC BEING L1 ACCEPTED | |
| 2 | L2₹5.1 L+₹15,855 (3.21%)Rejected-Finance C 234 ADG P CHENNAI | L2 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Mechanical cleaning and disinfection of RCC water tanks UG sumps and certain allied works supply of essential chemical annual maintenance/ services of RO plant installed at various location under GE (I) (CG) Chennai
2023_MES_574813_1
8993/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹8,000
Yes
14 Mar 2023
19 Jan 2023
16 Feb 2023
19 Jan 2023
13 Feb 2023
27 Jan 2023
Amount
De-watering and cleaning inner surface of Semi under ground sump of capacity 6.80 lakhs litres for phase-I pump house at Thalakancherry by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed .
De-watering and cleaning inner surface of Under ground sump of capacity 6.80 lakhs litres for phase-II pump house at Thalakancherry by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed .
De-watering and cleaning inner surface of Semi under ground sump of capacity 75000 litres for balancing tank in swimming pool at Thalakancherry by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including applying two coats of white wash and cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed .
De-watering and cleaning inner surface of Semi under ground sump of capacity 100000 litres at ICGAS Meenambakkam by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including applying two coats of white wash and cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed .
De-watering and cleaning inner surface of Under ground sump of capacity 50000 litres at DHQ-5, , RHQ(E) and BMU Royapuram ,CGRA Royapuram by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed
De-watering and cleaning inner surface of Under ground sump of capacity 30000 litres at CG PRT (E) Timber Pond and 308 Flats Ayapakkam by scrapping down with wire brush and washing with bleaching powder to remove sludge, clay, dirt and other foreign particles etc from the inner base of sump and removal of debris to a distance 50 m away from the site and depositing where directed including cleaning /surface dressing upto 20 meter around the sump complete all as specifed and as directed . NOTES: for Serial item nos: 1 ,2,4 to 6: Sumps has to be Cleaned at every 06 months interval
Mainteance of 250 litre per hour Reverse Osmosis Plant at CG Md Accn at Thalakancheery for smooth running and functioning as per schedule of maintenance mentioned in Appendix "A" complete all as specified and as directed.
Description all as per Srl item NO: 07 here in before but plant capacity of 500 litre per hour reverse Osmosis Plant at ICGAS Meenabakkam, Chennai
Replacement of micro filter of size (20' X 4") Spun-5 micron Jumbo Wound Complete all as specified and as directed.
Replacement of micro filter of size (20' X 2.5") Spun-5 micron PP Wound Complete all as specified and as directed.
Replacement of micro filter housing of size (20' X 4") Spun-5 micron Jumbo Wound Complete all as specified and as directed.
Replacement of micro filter housing of size (20' X 2.5") Spun-5 micron PP Wound Complete all as specified and as directed.
Supply of Sodium Hypo Chloride Solution for plant including mixing into water as per requirement complete all as speicified and as directed.
Supply of SMBS for De-chlorination for plant including mixing into water as per requirement complete all as specified and as directed.
Supply and fix End Cover and Saddle for membrance housing 40-40
Chemical cleaning /washing of membrane of Size 40-40 during routine maintenance work
Supply of Anti Scalant chemicals for plant including mixing into water as per requirememnt complete all as specified and as directed.
Replacement of dosing pump set for RO palnt of capacity 6 litre/hour, single Phase, 230 Volt , AC testing and commissioning of Pump complete all as specified and as directed. NOTE: Contractor shall submit two year warranty for pump.
Replacement of unserviceable membrane housing and provision of membrane as per existing size 4" BW 40-40 for capacity 500 litre, 1000 litre/per Hour RO Plant complete all as specified and as directed. Make: Flimtec/Osmonics/GE/Hydraunatics/Pentair
Replacement of unserviceable membrane housing and provision of membrane as per existing size 4" BW 80-40 for capacity 500 litre, 1000 litre/per Hour RO Plant complete all as specified and as directed. Make: Flimtec/Osmonics/GE/Hydraunatics/Pentair
Replacement of unservieable float valve and Supplyy and fix new float value of 20 to 25 mm size/as per existing size complete all as specified and as directed. Make:M/S Ozone Technologies/GE.
Replacement of unservicable existing skid complete and Supply and Fix New Frame/Stand/Skid for R O Plant made out of staniless steel -grade 304 material suitable for 250 LPH capacity including necessary demolition of existing PCC Platform and provision of PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform (0.5cum Approx) for fixing of Skid including removal of debris of distance not exceeding 50 metres complete all as specified and as directed.
Replacement of unservicable existing skid complete and Supply and Fix New Frame/Stand/Skid for R O Plant made out of staniless steel -grade 304 material suitable for 500 LPH capacity including necessary demolition of existing PCC Platform and provision of PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform (0.5cum Approx) for fixing of Skid including removal of debris of distance not exceeding 50 metres complete all as specified and as directed.
Replacement of unserviceable LP switch and Supply and fix new LP switch (KP 35) as per existing size complete all as specified and as directed. MAKE: Ozone technologies/GE/Donfoss.
Replacement of unserviceable HP switch and Supply and fix new HP switch (KP 36) as per existing size complete all as specified and as directed. MAKE: Ozone technologies/GE/Donfoss.
Replacement of unservicable UPVC pipe of any size and Supply fix 40 mm bore UPVC pipes of pressure rating 10 kg/cm2 with fittings laid in trenches/on wall/floor fixed with clamps complete all as specified and as directed. MAKE: Finolex/Trubore/Supreme
Replacement of unservicable UPVC pipe and Supply fix 25 mm bore UPVC pipes of pressure ratng 10 kg/cm2 with fitting laid in trenches/on wall/floor fixed with clamps complete all as specified and as directed. MAKE: Finolex/Trubore/Prince
Replacement of uservicable flow meter and Supply fix new flow meter as per existing size complete all as specified and as directed. MAKE: Ozone technologies/GE/Donfoss.
Supply only 10mm dia PVC hose pipe for pressure gauge and dosing
Supply only pressure gauge 0-25kg/cm2
Supply only Needle ball valve for dosing pump
Supply and fix PVC ball valve of 1" dia
Supply and fix PVC ball valve of 3/4" dia
Supply and fix Ultra violet lamp housing for 500-1000 litres capacity RO Plant
Replacement of unservicable multi port valve and Supply and fix new multi port valve of size 40NB TMF SOLO, 250 to 500 LPH capacity RO Plant complete all as specified and as directed. MAKE: Ozone technologies/GE/USS/Solo
Replacement of unservicable control panel and supply and fix new control panel Astro Panel 33 complete all as specified and as directed. MAKE: Astro/GE.
Servicing/Repairing of Auto control panel Astro-33
Replacement of unservicable pressure sand filter media and Supply and fix new pressure sand filter media suitable for 500/1000LPH RO plant complete all as specified and as directed. MAKE: Astro/GE.
Replacement of unservicable Activated carbon filter media and Supply and fix new Activated carbon filter media suitable for 500/1000LPH RO plant complete all as specified and as directed. MAKE: Astro/GE.
Supply, hoisting,installing and connecting rotational mould polyethylene water storage tank of capacity 500 litres , double layered cylindrical vertical tank with closed top confirming to IS 12701:96 complete all as specified and directed MAKE: Sintex/Aquaplus/Polycon
Supply, hoist,install and connect rotational mould polyethylene water storage tank of capacity 2000 litres , double layered cylindrical vertical tank with closed top confirming to IS 12701:96 complete all as specified and directed MAKE: Sintex/Aquaplus/Polycon
Re-programming Automatic Digital multi port valve with reference to interconnected other media filters and control panel board
Servicing/Repairing of Automatic Digital multi port valve (25NB Auto valve solo)
GMS Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .