Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | ₹5.4 Cr Quoted ₹5.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹5.9 Cr+₹35.2 L (6.38%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹5.9 Cr+₹35.2 L (6.38%) | L2 | Rejected-Finance Being Other than Lowest |
| 3 | L3₹5.9 Cr+₹38.5 L (6.98%)Rejected-Finance | ₹5.9 Cr+₹38.5 L (6.98%) | L3 | Rejected-Finance Being Other than Lowest |
| 4 | L4₹6.0 Cr+₹49.9 L (9.03%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹6.0 Cr+₹49.9 L (9.03%) | L4 | Rejected-Finance Being Other than Lowest |
| 5 | L5₹6.1 Cr+₹61.0 L (11.0%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹6.1 Cr+₹61.0 L (11.0%) | L5 | Rejected-Finance Being Other than Lowest |
Tender Value
₹6.3 Cr
EMD Value
₹6.4 L
Closing Date
10 Feb 2020, 6:00 pmClosed
CWE NW MUMBAI
DR HOMI BHABHA NAVY NAGAR ROAD COLABA MUMBAI
ADDITION ALTERATION AND SPECIAL REPAIRS TO OFFRS MARRIED ACCOMMODATION G AND H BLOCK AT NOFRA MUMBAI UNDER GE NW NOFRA 2ND CALL
2019_MES_272192_2
8686/CWE (NW) MUMBAI
Open Tender
Civil Works
Item Wise
540 days
GE NW NOFRA
Class A and Category a (i)
9 documents required · 9 mandatory
₹3,000
Yes
GE NW NOFRA
₹6.4 L
Yes
19 Jun 2020
11 Jan 2020
11 Feb 2020
11 Jan 2020
10 Feb 2020
18 Jan 2020
Amount
Dismantling floor, hearth or wall tiling (fixed at any position but not backing) including cement mortar bedding and removing and removing rubbish off the premises (outside MD land) complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 6th floor
Material & labour for Non Skid rectified coloured ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc.set laid in flooring with 15mm screed bed in cm 1:6 including levelling the floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge. Make:- Somany,Orient bell & Kajaria.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for coloured glazed rectified ceramic tiles 300 X 450 X 7mm or 300 x 600 x 7 to 8mm thick as on vertical surfaces such as in dado/ skirting over & incl 10mm th backing coat in cement mortar 1:3 set jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and directed by Engineer-in-Charge. Make:- Somany,Orient bell & Kajaria.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for coloured vitrified tiles of size 600 x 600 mm, 9 to 10mm thick, laid in flooring, with & including 5mm thick adhesive of Ferrouscrete (FERRO-1122) / Fevimate XL- Pidilite / Gold star of Bal Endura or equivalant including necessary roughning of existing PCC flooring & levelling the floor if required, grouting the joints complete all as specified and directed by Engineer-in-Charge. Make:- Kajaria (the star series), Somany (ultra Charge) ,Orient bell (Ultra charge).
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for coloured vitrified tiles 9 to 10mm thick, superior quality, 100mm high skirting, over & including a backing coat of 10mm thick in CM 1:3, complete and making nosing at right angle corner, including levelling the wall complete all as specified and directed by Engineer-in-Charge. (Note :- Skirting shall be flush with the walls) Make:- Kajaria (the star series), Somany (ultra Charge) ,Orient bell (Ultra charge).
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, rivetting, etc not exceeding 10 Kg each brackets, conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in counter top ceramic wash hand basin vitreous china with pillar tap, brass chromium plated waste coupling 32mm with long screwed and fly nuts ,incl 60 cm long,32mm dia PVC(flaxible) type waste pipe fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make for WHB :- Jaquar Cat Part No. FLS-WHT-5935 or equivalent in Grohe, Kohler . Make for Pillar tap :- Jaquar Cat Part No. KUP 35001PM or equivalent in Grohe, Kohler.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in white vitreous china ware wash down water closet pan (pedestal pattern) incl trap, connection to drain (or outgoing pipe) with matching plastic seat cover fixed in repairs complete all as specified and directed by Engineer-in-Charge. Make : Jaquar Esscco, Grohe, Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 10 ltr capaciaty PVC low level flushing cistern with dual flushing system including brackets 5/10 litre capacity with 32mm bore polythene flush pipe of sufficient lenght including internal fitting (valve less syphonic) etc. complete fixed as in repairs. MAKE : Jaquar continetal/ Grohe / Kohler.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in toilet paper holder fixed in repairs complete all as specified and directed by Engineer-in-Charge. Make : Jaquar cat Part No.ACN 1151N or equivalent in Grohe/ Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in soap dish fixed in repairs. Make : Jaquar cat Part No.AKP 35731P or equivalent in Grohe/ Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in PVC cabinet with openable shutter and mirror with size of 450mm x 350mm with thickness of mirror not less than 2mm, fixed to wall with brass screwes in repairs complete all as specified and directed by Engineer-in-Charge ( Make : PRAYAG cat part No. 551 or make mentioned in Appendix 'B')
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in repairs stain less steel tubular towel rail 20mm dia 60cm long between flanges. Make-Jaquar cat no AKP-35711PS or equivalent in Grohe/ Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Demolition of cement concrete filling of any description in sunken portion and removing debris out side MD land complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Demolition of cement concrete (PCC/RCC) in ground floors n exc 15 cm thickness (below or above ground floor) and removing debris out side MD land complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (a) Material & labour for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 4omm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately) (b) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately) (c) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (d) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (e) Plaster the bottom and sides up to bottom of the skirting with 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is inclued in the rates quoted above.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
Cutting holes in bricks or RCC walls exce half brick built in cement mortar including making good after inserting and setting spouts complete all as specified and directed by Engineer-in-Charge
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and directed by Engineer-in-Charge
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
Material & labour for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion complete all as specified and directed by Engineer-in-Charge
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan) shall be paid separately complete all as specified and directed by Engineer-in-Charge
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
Material & labour for preparation of new steel surfaces of any description exc 10cm in width or girth and applying two coat of Black bituminous paint over one coat of red oxide primer. Make :- Asian, Berger or Nerolac .
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
Material & labour for injection grouting in RCC slab shall be cast/laid to the slope. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expose. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for PCC 1:7:12 with brick agg as in lean concrete/filling concrete complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor.
(b) From 5th floor to 8th floor
Material & labour PVC floor trap with grating dia of outlet 75mm including jointing to waste pipe in cement concrete type B1(1:2:4) as in repairs.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix low density polyethylene (LDPE) pipes 40mm dia of pressure rating 6 Kg /CM2 laid in walls/floors from WHB out let upto Nahani trap including required Nos of fittings, and cutting chasing in, etc complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Kitchen sinks with drainage board made of stainless steel 1 mm thick (SS grade 304 AISI 18/8) IS embosed (IS : 13983) gloosy finish ktichen sink with plugs, washeres and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460 mm bowl size 410 mm x 330 mm x 160 mm, as in repairs complete all as specified and as directed by Engineer in Charge. MAKE :- Blanco, Cera Cat log No, Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 38mm dia PVC (flexible) waste pipe, 800mm long for Kitchen sink complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in stainless steel handle fabricated type anodised 100mm long of approved design shape and make fixed in repairs with nut screw & washers complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Demolition of brick work built in cement mortar or cement lime mortar an removal of debris out side MD land complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for brick work built in cement mortar 1:6 with sub class B bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for brick work sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls in cement mortar 1:4 etc complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Vitreous water closet (Squatting pan, Orissa pattern, size 580 x 440 white, with integral foot rests and 'P' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete fixed in repairs complete all as specified and directed by Engineer-in-Charge. Make : Jaquar, Kohler, Grohe
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Taking down chowkats exc 1.5sqm and n.exc 4 sqm each with shutters complete all as specified and directed by Engineer-in-Charge(without taking off shutters from the chowkats or frames)
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Taking down chowkats not exceeding 1.0Sqm each with shutters (without taking off shutters from the chowkats or frames) complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Taking down shutter exceeding 1.0Sqm and not exceeding 2Sqm each with shutters (without taking off shutters from the chowkats or frames) complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Taking down shutters of any description exceeding 1 sqm and not exceeding 2Sqm each and refixing in the same opening after easing and adjusting complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 2nd class HW plain, solid, straight chowkats and frames,wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fixin 40mm thick factory made plain framed, panelled shutters (two panel), 2nd class HW rail and style, with lock rail and panel of 9 mm B.W.P commercial ply with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for 35mm thick 2nd Class Hard Wood as glazed and skelton shutters open rebated and prepared to receive glass, gauze etc, edges of forming plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters with sash bars all as specified in SSR Pt-I
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for factory made moulded door shutter 35mm thick , consisting of solid core single leaf flush door of 30mm thick, lipped with 15mm (5mm x3) thick x 30mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30mm width on the other stiles & bottom rails. The inner panel laminated with 2mm thick PVC sheet of density 600 Kg/Cum Manufactured by an ISO 9001-2015 certified company . Termite proof, water proof and fire resistant moulded PVC sheet with 2, 4, 6 raised panel design in different plain and or prelam PVC sheet on other side after routing the moulding design on flush doooor & 2mm plain and or prelam PVC sheet on other side using rubber based adhisive on the PVC lipping etc. complete all as specified and directed by Engineer-in-Charge incl supplying and fixing in frame at site as per specication and apporved by GE etc complated all as specified and directed. Make:- Sintex, Rajshree.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Solid PVC door frame of size 100 x 45mm made out of 5mm wood grain printed PVC sheet reinforced with MS square/rectangular tube fixing in existing opening including & edges will be painted to match with prelam sheet necessary hold fast and concrete complete all as specified and directed by Engineer-in-Charge. Make:- Sintex, Rajshree.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Marble Baroda green 18 to 20 mm thick (table rubbed and polishing) as in skirting/dado/ window cills/ jambs, vertical surface over cement rendering and jointed with grey cement,over and including screed bed of 15mm thick in CM 1:4,including pointing in white cement (1:2) using marble dust with admixture of pigment to match with the shade of marble and making nosing at right angle corner complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix powder coated (50Micron minimum thickness) aluminum frame for door ,windows,ventilators etc.with one or more rebates including joining cleat for fixing etc.fixed type/louvered window or ventilator without sash bar,aluminum including necessary joining cleats,glazing clips,rubber packing,anodised aluminum snap beading,screws, sliding rollers, Rubber gasket complete all as specified and directed by Engineer-in-Charge Note:a) Glazing shall be measured seperately. b) Item shall be paid as per weight of alluminium section.c) The rate quoted shall be inclusive of neoprene beading,glazing clips,screws, etc., as required which shall not be measured for arriving the weight.d)the rate shall be inclusive of the locking arrengement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Mild steel work as in window, balcony grills of Mild steel in Angle, flat, round or square bars etc., with ends of bars shouldered and/or riveted, and similar work conforming to Fe 290 Gde-E-165.for Servant balcony portion and including removal of existing wooden frame with wire mesh/net complete all as specified and directed by Engineer-in-Charge
Supply & fix hold fasts and similar small articles conforming to Fe 410-0or 310-3.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Preparing surfaces of wood and wood based/materials of any descriptions and treating ends of posts backs of chowkats with tar, area tarred exc 0.10 Sqm but n.exc 0.50 Sqm each complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for preparation of surfaces of steel or iron work treating small article such as hold fast clamps etc with black bituminous paint area n.exc 0.15 Sqm in each complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply and fix 5.50 mm thick plain glass n exc 0.5 sqm in each pane fixed to aluminium windows and iron frame complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply and fix 5.50 mm thick plain glass exc 0.5 sqm in each pane fixed to aluminium windows and iron frame complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 4mm thick glass sheet ordinary quality frosted on one side, n exc 0.5Sqm in each pane,fixed to Aluminium windows complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100mm long butt hinges medium weight stainless steel with ISI mark. Make Godrej, Hettich, Kaff
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in repair 100mm long butt hinges medium weight stainless steel with ISI mark. Make Godrej, Hettich, Kaff
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 50mm long butt hinges medium weight stainless steel with ISI mark.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Godrej night latch seven levers suitable for 35mm to 45mm thick doors in repairs complete all as specified and directed by Engineer-in-Charge. Make : Godrej Product code 7666 or 7793 or equivalent in Hettich, Kaff
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Aluminum alloy anodized Aldrop bolt 300mm long with hasp and staple and fixing bolts complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Aluminum alloy anodized Aldrop bolt 300mm long with hasp and staple and fixing bolts in repairs complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Aluminum anodized barrel tower bolt of extruded section 200mm long complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in repairs Aluminum anodized barrel bolt of extruded section 200mm long complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Ditto same as item above but 150mm long.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
All as above but fixed in repairs 150mm long.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fixin extruded aluminium alloy handle fabricated type anodized 125mm long complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in repair extruded aluminium alloy handle fabricated type anodized 125mm long complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in peep hole , Magic eye brass to entrance door shutter in repairs complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Door stopper wall mounted megnetic latch type arrrangement of make and pattern, approved by GE, fixed with screws on skirting and plate with spring arrangement fixed on door in repairs complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 20mm dia stainless steel curtain rod or similar articles complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in stainless steel decorative type brackets suitable for 20mm dia curtain rod or similar articles complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in alumunium powder coated brackets suitable for hanging 20mm dia rods in Wardrobs and Curtain in Shower Area fixed on stone/ walls with screws, complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in stainless steel wire cloth 0.36mm niminal dia with 1.4mm average width of aperature, fixed as in aluminium window shutterscomplete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in stainless steel wire cloth 0.36mm niminal dia with 1.4mm average width of aperature,, fixed as in wooden window/door shutters as in repairs, complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Dismantling boarding any description fixed in any position with screws complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in slide on hinge OK with mounting plates to hinges plate and fixed with screws complete all as specified and directed by Engineer-in-Charge. Make:- Hettich,Godrej, Ebco.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for 12mm thick Marine plywood, grade BWP, type BB with both side 0.9mm thk decorative choice laminate type 1 of surface finish, colour and pattern as approved , fixed with approved adhesive as per manufacturer's instruction, fixed with screws to timber frame work including 1st class HW lipping alround the shutter/edges and polishing etc as in modular kitchen shutters complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for 18mm thick Marine plywood, grade BWP, type BB with both side 0.9mm thk decorative choice laminate type 1 of surface finish, colour and pattern as approved i, fixed with approved adhesive as per manufacturer's instruction,fixed with screws to timber frame work including 1st class HW lipping alround the shutter/edges and polishing etc as in cupboard shutters complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Megnetic latch of approved pattern and shape fixed with screws on wooden surfaces complete all as specified and directed by Engineer-in-Charge. Make:- Takiger, Godrej.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour PCC 1:2:4 B1 (20mm graded aggregate) as in bed blocks, copings, benchings, railing, bends etc incl necessary form work complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Taking down existing cement or cement lime plaster and preparation of surfaces of walls of any description incl racking out joints backing for scrubbing down with water and any height including necessary scaffolding and removing debris out side MD land complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Plastering in cement & sand mortar 1:4, 15mm thick on fair faces of brick work or concrete surfaces of walls finished even and smooth on wall any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for rendering 5 mm thick cement plaster in brick or concrete surfaces in CM 1:3 as on ceiling finished even and smooth with 3mm thick wall care putty on ceiling any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 30mm thickness including leveling profliling complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for rendering 20mm thick on other than fair face of brick work or concrete in two layer first is 15mm thick CM 1:4 and seconed 5mm thick cement mortar 1:4 mixed with water proofing powder at the rate of 2% of cement or as per manufacturers instructions and any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge. Note:-Water proofing compound shall be measured sepratly under respective item.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply only integral water proofing compound
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material and labour for preparation of old plastered surfaces by complete removal of existing treatment including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts done by mechanical means / All painting shall be done by smart painting techniques, applying two coats of emulsion paint on ceiling over a coat of alkaline resistant primer over and including a coat of putty to plumb the existing surface at any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge. Make :- Asian Tractor UNO, Berger COMMONDO or Nerolac LITTLE Master
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material and labour for preparation of newly plastered surfaces done by mechanical means, All painting shall be done by smart painting techniques, applying two coats of emulsion paint on ceiling over a coat of alkaline resistant primer over and including a coat of putty to plumb the existing surface at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. Make : Asian Tractor UNO, Berger COMMONDO or Nerolac LITTLE Master.”
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material and labour for preparation of old plastered surfaces by complete removal of existing treatment including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts done by mechanical means /All painting shall be done by smart painting techniques, Applying two coats of emulsion paint on wall surfaces over a coat of alkaline resistant primer over and including a coat of putty to plumb the existing surface at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. Make : Asian Tractor UNO, Berger COMMONDO or Nerolac LITTLE Master
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material and labour for preparation of newly plastered surfaces done by mechanical means, All painting shall be done by smart painting techniques, applying two coats of emulsion paint on wall over a coat of alkaline resistant primer over and including a coat of putty to plumb the existing surface at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. Make : Asian Tractor UNO, Berger COMMONDO or Nerolac LITTLE Master.”
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for preparation of new wooden surfaces of any description exc 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of primer complete all as specified and directed by Engineer-in-Charge. Make:- Asian Apocillite, Berger Hi- luxol, Nerolac hi gloss.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Make:- Asian Apocillite, Berger Hi- luxol, Nerolac hi gloss.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for Preparation of old plastered/concrete surfaces on ceiling applying two coats of textured exterior acrylic emulsion (weather proof treatment) over one coat of primer, complete all as specified and as directed ( The tint and shade be as approved by the GE) The treatment shall be carried out by the authorised applicator of the firm and at any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge. Make : Asian paint ultima allura venezia or equivalent in Berger and Nerolac.
Preparing of old decorated surfaces of walls/ceiling washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers, applying two coats of acrylic latex base exterior grade (100%Acrylic)cutting, chasing the cracks at least mm deep by means of grinder/machine etc.including necessary scaffoling complete all as specified and directed by Engineer-in-Charge
Preparing of new surfaces of walls/ceiling (of projected Cup boards, rain beating side) washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers and applying two coats of Rain coat manufactured by Dr Fixit of Piddilte Industries Ltd or liquiplas PUD (Rain sheld / Terra Sheld) IWL India Ltd. (shade to match the existing paint) complete all as specified and directed by Engineer-in-Charge
Taking down Cast iron/AC pipe of any dia and size fixed on wall or floor including all fittings complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste. complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100 mm dia sand cast CI bend of any radius, jointed with neat cement paste complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100 mm dia sand cast CI branch piece single branch of any radius, and jointed with rubber ring joint complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100 mm dia sand cast CI branch piece double, of any radius and jointed with with rubber ring joint complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 100mm dia cast iron cowls on roof
Supply & fix in 150mm dia UPVC (Sch 40) pipes as in rain water pipes including all necessary fittings i.e bends, shoes, etc and fixed to walls by using necessary clamps/ fittings complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for for cutting holes into or through cement concrete slab, chajjas etc superfical area exc 100 sqm cm but n exc 250 sq cm and making good the exisiting surface complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in Stain less steel Towel ring 150mm dia of approved make. Make : Jaquar, Grohe, Kohler
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for preparation of new steel surfaces of any description exc 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Make :- Asian Apcolite, Berger luxol or Nerolac Hi -gloss.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for preparation of old steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Make :- Asian Apcolite, Berger luxol or Nerolac Hi -gloss.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for 20 mm thick granite work as in cooking platform & table top WHB in cement mortar (1:4) including bull nosing/ moulding on all exposed edges/sides and pointing in white cement (1:2) using marble dust with admixture of pigment to match with the shade of granite complete all as specified and directed by Engineer-in-Charge
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 75 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste complete all as specified and directed by Engineer-in-Charge. Make :- Neco, Jindal
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 75 mm dia sand cast CI bend of any radius, jointed with neat cement paste.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 75 mm dia branch piece single branch of any radius, and jointed with neat cement paste.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in 75mm dia cast iron cowls on roof.
Material & labour for 18 to 20 mm thick both side mirror polished kota stone work as in Partitions/ shelves as in Wardrobes, fixed in cement mortar (1:4) including cutting chasing in walls,bull nosing/ moulding on all exposed edges/sides and pointing in white cement (1:2) using marble dust with admixture of pigment to match with the shade of Kota stone complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion@ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engineer-in-Charge
Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution)@ .5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-Charge.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fix in decorative corner glass shelf shall be size of 300 X 120 mm and 8mm thick with railing 25mm high having edges rounded off and shall be supported on chromium plated brass brackets fixed with chromium plated brass screw on plugs or gutties fixed in wall. Make:- Cera Catlogue No, Parryware, Somany.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Supply & fixin repairs stainless steel plate rack of size 900X580X210 mm fixed to wall with screws complete all as specified and directed by Engineer-in-Charge Make:- Cera Catlogue No, Kohler, Diamond blanco.
(a) From Ground floor upto fourth floor
(b) From 5th floor to 8th floor
Material & labour for protecting the roof with water proofing coating (Dr. Fixit) complete as specified below :- (a) Wire brush the surface to remove loose particles & laitance wash with clean water. (b)complete crack filling & reinstate damaged portion shall be filled with polymer modifie mortar as recommended. (c) allow the repair surface to cure for 24 hours afterwards wet the surface to a saturated surface dry condition (d) apply one coat of primer by brush and allow to dry for 4 hours (e) Apply one coat of water proofing coating over the primed surface by brush on the wet primed surface overlay a open- woven fiber glass mesh min 40 GSM of size 2mm x 2mm and allow it to soak completely (g) immediately there after apply the second coat with a roller to ensure complete coverage of the fibre mesh (h) apply the 3rd coat after 6 to 8 hours, once the 2nd coat is dry Make : Crack filler : Dr. Fixit crack-X Paste, Dr. Fixit crack -X shrinkfree, Shaliseal CPM of M/S STP Ltd Prime Coating : Dr. Fixit Primeseal Water Proofing Coating : Dr. Fixit Newcoat, Waterseal concentrate of M/s Krishna Conchem Products, Shalicry 215 of M/s STP Ltd, Liquiplas PUD of IWL India Ltd. ( NOTE : Cost of removing Existing APP Treatment is included in quoted rate )
Material & labour for 10mm thick rendering in cement and sand mortar 1:4 on roof padding concrete surface for levelling course rounded or chamfered on edges, slopping mixed with water WPC @ 2% by weight of cement, finished even & smooth surface without using extra cement incl taking down of old cement mortar plaster of any description complete all as specified and directed by Engineer-in-Charge. NOTE : (WPC shall be measured and paid seperately)
Supply & fix in repair framed work such as grills,gratings, Mild steel in flat, round or square bars etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; rallings; framework of watertanks and similar work conforming to Fe 290 Gde-E-165.for Servant balcony portion and including removal of existing wooden frame with wire mesh/net complete all as specified and directed by Engineer-in-Charge
Material & labour for preparation of new Steel surface synthetic enamel paint of two coats in any description, over 10 cm in width or girth, not otherwise described, over a coat of Red oxide, zinc chrome complete all as specified and directed by Engineer-in-ChargeMake :-Asian Apcolite, Berger Luxol, Nerolac Hi-gloss.
Removing and Refixing MS angle iron or tee sections, framed brackets of angles or tees,(not exc 10 kg each bracket) conforming to Fe-290.Grade-E-165, purlins for fixing roof / fixing sheets as in chhajjas with coach screws and washers with 20mm wide x 3mm thick tie to frame work and fixed to walls / supports by means MS 10 mm dia 150 mm long dash through fasteners in concrete, brick work, including drilling hole, including distance pieces, cleats etc. and welding any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge. Note : Dash Fasteners will be paid and measured saperately.
Material & labour for preparation of old Steel surface synthetic enamel paint of two coats in any description, over 10 cm in width or girth, not otherwise described, over a coat of Red oxide, zinc chrome complete all as specified and directed by Engineer-in-Charge. Make :-Asian Apcolite, Berger Luxol, Nerolac Hi-gloss.
Removing and Refixing of existing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified any height including necessary scaffolding complete all as specified and directed by Engineer-in-Charge
Material & labour for repairs Galvalume sheets in chajjas/walls/roof, fitting & fixing anti corrosive pre painted/colour coated galvalume base sheet of thickness 0.50mm TCT having high tensile strength not less than 550 Mpa yield strength CR steel base metal with hot dip alloy coating of A1-Zn-si as per ASTM-A-792 M - 02/AS-1397 ALU-SINC alloy sheet shall be on alloy of 55% Aluminium = 43.5% Zinc+1.5% Silicon. The total coating of alloy shall not be less than 150 grms per Sqm (AZ150) as per ASTM-792 or AS -1397 with top coat of 20 micron (DFT) epoxy primer. The overall width shall be 1072 mm and effective width of sheet shall be 1015mm. The profile shall be 203 x 28.5 mm. The sheet shall be provided with protective polythene cover for avoiding damage during transit. Each sheet shall have manufacturers name / batch No etcduly marked on rear side of the sheet. The sheet shall be fixed to purlin with self drilling and self tapping screws of 12 guage dia, Zn/ Sn alloy coated by mechanical coating @ 5 per sqm ie. sheet shall be stiched with the purlins at the every crest conforming to IS AS-3566 of ATW- HILTY/ Buildex corroshield make with moulded EPDM washers all as specified and directed. The length of screw shall be 55mm having 14 threads per inch. It shall have threads atleast 1/8th inch at top and 2 threads extra at bottom to achieve maximum pull out strength. For stiching operation in between the purlin support (sheet to sheet, flashings, ridges) 10 guage / 20mm length/ 12 threads per inch self drilling and taping screws shall be fixed at every crest of the sheet. NOTE :- (a) Rate quoted is deemed to be inclusive of leak proof jointing and testing of roof sheets. (b) Fixing of sheets shall be carried out by authorised fabricator of manufacturer.
Chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debris out side the premises complete all as specified and directed by Engineer-in-Charge. Hard concrete shall not be removed by force.
Clean existing reinforement with/ rotary wire bruch, making the surfaces free from loose material dirt etc, complete, applyin g two coats of alkaline rust converting primer FEOVERT confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and directed by Engineer-in-Charge
Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET_RB complete all as specified and directed by Engineer-in-Charge
Carryout application of bi-polar migratory corrosion inhibitor EPCO-KP-100/Protectsil/ CIT/Ferogard 903 on concrete surface (This inhibitor shall have migratory kind of properly which permits the material to a vertual extent of 100mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete
Material & labour for drilling and fixing Rohibb Teflon nozzoles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 center to center in staggered manner complete all as specified and directed by Engineer-in-Charge in RCC structural element work shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia, Rohibb Teflon nozzles in cleared holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hours. (iii) Cutting the nozzles. Cut the nozzles by chiselling after completion of grouting without damaging structural elements.
Material & labour for injecting of site cement slurry grout, in ratio 1:2 (1 Cement, 2 water) including super plasticizer (Supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/ specified grout by means of pump at a pressure of 0.5 Kg/CM2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. (For repair to slab).
Material & labour for injecting low viscosity MONOPOL (3-5cps) high molecular weight monometer by pressure and using mechanized injector gun with accessories till nozzles rufeses to accept the hrout, including , mixing of materials, mixing of material components (Part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting maintain the pressure at exit (0.5 to 1.0 Kg/ Cm2) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzles. (Beam & columns)
Providing and applying structural grade EPIBOND-21-LP prior to application of any type mortar plaster confirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bond between old concrete and new concrete)
Providing and applying jacketing around columns with micro concrete (Molith MC) M40 including all lifts, shuttering, drilling, holes and fixing shear anchor complete all as specified and directed by Engineer-in-Charge. Note :- Reinforcement shall be measured and paid saperately (Rates including jacketing, formwork and micro concrete)
Material & labour in repair water proofing treatment with APP based polymeric membrane reinforced of 4.5Kg/Sqm with non woven polyester mat of weight 150 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer @ 0.25 Kg/Sqm over roof (An overlap of 100mm and 150mm shall be provided on sides and ends respectively) and including all joints made water tight and applying two coats of aluminium paint and taking down old sheets and removing outside MD land or store all as appproved by GE
Demolition of concrete in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge
Material & labour for 50mm thick PCC (1:2:4) as in plinth protection
Supply & fix in stainless steel kitchen baskets for storage of plates, cups, bottles etc., made out of stainless steel of grade SS 304 not less than 6 to 8 Kg each using square hollow tubes of size 12mm x 12mm x 1.25mm thick for framework as required and solid round bars / 26 guage thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete. Note : (i) Telescopy channels shall be measured and paid under separate item.
Supply & fix in Telescopy channels, powder coated with ball bearings, suitable for Sliding stainless steel kitchen basket 60cm long standard width; fixed over 2nd class hard wood rectangular fillet sectional area exc 3 & n exc 6 Sqcm, clean swan secured with screws and the fillet fixed on cuddapah stone with screws, complete all as specified and directed by Engineer-in-Charge. Make : Hettich,Godrej, Kaff
Machine cut cuddapa stone slabs 20-25mm thick fixed with cement mortar/1:3 screed base laid and jointed with grey cement slurry as in verticle/ horizontal supports for cooking platform complete all as specified and directed by Engineer-in-Charge
Supply & fix in MS 10 mm dia 150 mm long dash through fasteners in concrete work, including drilling hole, complete all as directed by Engineer-in-Charge.
Supplying, fabricating and fixing wall cladding (for all height) of aluminium composite panel in metallic/ non metallic colour of approved shade made out of 3mm thick aluminium composite panel material consisting of 2mm thick mineral core sandwiched between two aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with kynar 500 based PVDF/Lumiflon based fluoropolymer resin coating of approved colour and shade on exposed face and polymer (service) coating on other face, fixed over and including base frame fabricated with aluminium square pipe of size 25mmx20mm with 1mm wall thickness in 600mmx600mm size grid including stainless steel screws, nut, bolts, washers, cleats, weather silicone sealent for groove filling, backer rods etc, complete all as per Manufacturer instruction and as directed.
Taking up or down steel water tubing and connections and removing to store of following sizes, complete all as directed by Engineer-in-Charge.
(a) 50 mm bore
(b) 25 mm bore
(c) 20 mm bore
(d) 15 mm bore
Supply and fixing 3 Layer PPR (Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV stabilized and anti microbial welded having thermal stability for hot and cold water supply including all PPR plian and brass PPR random fittings of required sizes and fixed to wall/ ceilings laid in floor or concealed of following sizes in buildings of G+5 floor incl scaffolding) complete all as directed by Engineer-in-Charge. Make : SFMC, SHK, VESBO
(a) 90 mm bore
(b) 32 mm bore
(c) 25 mm bore
(d) 20 mm bore
Supply and fixing PPR gate valves of following sizes with iron wheel head screwed both ends for PPR polypropylene random coploymer pipes, with suitable fittings fixed to new line in position complete all as directed by Engineer-in-Charge.
(a) 90mm bore
(b) 32mm bore
(c) 20mm bore
Cutting chases for connected water tubing and making good in cement mortar 1:3, girth of cutting n exc 10cm in brick / concrete walls complete all as directed by Engineer-in-Charge.
Supply and fixing in clamps, Bands, straps, supports or stays for rainwater pipes/GI pipes/ CI pipes, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintel hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps,plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as directed by Engineer-in-Charge.
Supply and fixing Mild steel angle iron section (Fe 290 Gde E 165) fixed independently, without connecting plates, etc incl cutting to required length, drilling, welding etc and embedding in Brick work incl Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 as required as in loft Water tank base in bathrooms/kitchens etc complete all as directed by Engineer-in-Charge.
M& L for reparation of new surfaces of steel of any description, over 10 cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zink crome primer complete all as directed by Engineer-in-Charge.
Supply and fix in repair white rectangular PVC water storage tanks (Loft tank) of capacity following sizes with complete fitting including fixing 03 Nos tank nipples of GI/ PPR with washer for out let and inlet all as per manufacturers instructions including disconnecting service connections/over flow pipes and removing old tank complete all as directed by Engineer-in-Charge (Make : Sintex)
Supply and fixing in repair PVC profile suitable for PVC Loft tank of capacity following sizes including fixing of necessary aluminium channel around the profile complete all as directed by Engineer-in-Charge.
Supply and fixing rotational moulded polythylene water storage tank (cylindrical vertical with closed top) of following capacities hoisted and fixed in position including disconnecting all incoming and out going connections and provn of new fittings upto 80mm bore suitable for PPR pipes all as per extg/ new requirements all as specified and directed. Make : Sintex, Infra, Polycame complete all as directed by Engineer-in-Charge.
Cleaning of loft tanks of following capacities in existing position or taking down by removing out the residual water from the tank, removing dirt, cleaning the internal surfaces of the tank with high pressure controlled water jet pump by using different nozzles as per requirement. After sucking out entire moss and algae by wet vaccume pump, wash the tank with clean drinking water tank with cleaning solution on all internal surfaces, then cleaning the bottom surface of the tank with vaccume pump to make it dry and providing sticker showing the date of cleaningcomplete all as directed by Engineer-in-Charge.
(a) 150 Ltrs
(b) 270Ltrs
Supplying and fixing in repairs brass float valve flat type of size 15 mm bore, high pressure with polythene float & fly nut complete, screwed for GI pipe of following sizes including necessary GI fittings complete all as directed by Engineer-in-Charge.
Material & labour for taking down old mixer unit/ bib cock/ stop cock (concealed)/ stop cock/ shower/ mixer/ angular stop cock/ gate valve of any description and size complete all as directed by Engineer-in-Charge.
Supply and fix fancy type chromium plated brass mixer unit 3 in 1 with wall flange suitable for 15mm bore GI/ PPR tubing with necessary fittings complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No : FUS-29273UPR
Supply & fix in over head shower rose with Rubit cleaning system with shower arm and flange suitable for 15mm bore GI/ PPR tubing complete all as directed by Engineer-in-Charge.. Make: Jaquar Cat Part No : OHS-1709
Supply and fix in fancy concealed type stop valve with long shark and adjustable wall flange including union suitable for 15mm bore GI pipe complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No : CON-083KN
Supply and fix fancy type chromium plated brass angular stop cock suitable for 15mm bore GI tubing, with necessary fittings complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No : CON-059KN
Supply and fix in fancy type chromium plated brass Bib tap with wall flange suitable for 15mm bore GI tubing with necessary fittings complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No : CON-047KN
Supply and fix in hand Shower (Health Faucet) with 1 Meter Long flex tube in chrome finish including holder complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No. ALD-CHR-565
Supply and fix chromium plated brass Bib cock two way suitable for 15mm bore GI tubing and health faucet complete all as specified.Make: Jaquar Cat Part No : FLR-5041N
Supply and fix fancy in type chromium plated brass Bib tap with nozzle for washing mechine suitable for 15mm bore GI tubing with necessary fittings complete all as directed by Engineer-in-Charge. Make: Jaquar Cat Part No : CON-049NKN
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials for taking credit (credit of items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as directed by Engineer-in-Charge.
Material & labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through & including steel conduits of suitable size, ISI marked with accessories concealed in wall/ceiling/truss etc with metallic ISI marked terminal boxes concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of wire- Finolex, Polycab, Havells Make of casing & capping- Preesfit, Precision
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell point controlled by one bell push 5 Amps.
(g) one light point controlled by two 2- way switches
Material & labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through & including steel conduits of suitable size, ISI marked with accessories concealed in wall/ceiling/truss etc with metallic ISI marked terminal boxes concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 4.0 sqmm as earth continuity conductor connected to common earth as earth dolly for:- Make of wire- Finolex, Polycab, Havells Make of casing & capping- Preesfit, Precision
Supply & fix in Modular Switch , 6Amp, One way, 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular Blank Plate , One way, 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular Switch , 16Amp, One way, 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular Switch , 6Amp, 2 way, 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular type bell push , 6Amp, 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Bell electric AC 230Volt single pole musical type with ISI mark.
Supply & fix in Modular type, electronic fan regulator ( 5 step ), 450 Watts, 230 volts, 2 module Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
Supply & fix in Modular Socket oulet, 6 Amps, 2/3 pin combined 2 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular Socket oulet, 6/ 16 Amps, 2/3 pin combined 2 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 1 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor(Ave)
Supply & fix in Modular white cover plate with Frame 2 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 3 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 4 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 6 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 8 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular white cover plate with Frame 12 Module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 1 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 2 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 3 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 4 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 6 module. Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 8 module . Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in Modular metal flush box 12 module.Make : Legrand(Arteor), Schneider (Zencelo) , Anchor (Ave)
Supply & fix in repair LED baton integral aluminum body with white acrylic cover of lumen output 1800 -2400 Lux, 3000 to 6500 Kelvin with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as directed by Engineer-in-Charge. Make : Make- Philips/ Jaquar/ Havells
Supply & fix in repair LED baton integral aluminum body with white acrylic cover of lumen output 1000 -1200 Lux, 3000 to 6500 Kelvin with accessories internall prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as directed by Engineer-in-Charge. Make: Philips/ Jaquar/ Havells
Supply and fix aesthetically designed wall bracket light with B22d lamp holder complete all as specified and directed. Make: Jaquar Lighting Cat No KWB-CHR-MB48021A / Philips Cat No 58185 / Havells Cat No LHJE02106499
Supply & fix in LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply. Make- Philips/ Jaquar/ Havells/ Syska
Taking down MCB DB of any type, single phase including disconnection of all circuits complete with MCBs etc.
Supply & fix 12 way Double door type having protrection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make-Schneider/Siemens/Legrand
Supply & fix in MCB SPN 63 Amps, 240 Volts, C Series . Make Legrand Model No 408620.
Supply & fix in MCB SP 6-32 Amps, 240 Volts, C Series . Make Legrand Model No 408595
Supply & fix in repairs single phase sheet metal powder coated distribution board 4 way comprising with following:- Make-Schneider/Siemens/Legrand
Supply & fix in MCB SPN 40 Amps, 240 Volts, C Series . Make Legrand Model No 408618.
Supply & fix in repairs sheet metal enclosure 2 way without bus bar with MCB (a) Isolator DP 63 Amps Breaking capacity 10 KA. (C series) Make-Schneider/Siemens/Legrand
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces.
Supply & fix in 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC conduits of suitable size not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4.0 sqmm (green colour) for earthing. Note : 2 runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 2.5 Sqmm cable shall be measured as 1 Run. Make of wire- Finolex, Polycab, Havells Make of casing & capping- Preesfit, Precision
Supply and fix in 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC conduits of suitable size not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note : 2 runs of 10 Sqmm cable, 1 run of PVC casing caping and 1 run of 06 Sqmm cable shall be measured as 1 Run. Make of wire- Finolex, Polycab, Havells Make of casing & capping- Preesfit, Precision
Taking down old UNSV water heater of any type / capacity from site.
Supply and fix , testing and commissioning of storage type water heater (geyser) vertical type of 6 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete all as directed by Engineer-in-Charge. Make- Havells/ Jaquar ELENA / Philips
Supply and fix RCCB with MCB of 2 Pole, 10 Amps rating with sensitivity of 30 mA suitable for 240 Volts complete all as directed by Engineer-in-Charge. Make-Schneider/Siemens/Legrand
Supply and fix in 15 Amps plug top, AC 230 volts, ISI marked.
Taking down ceiling/exhaust fan, sealing cable end, dismantling blades and removing fan and blades to MES E/M Store complete all as directed by Engineer-in-Charge.
Supply & fix in repair Ceiling Fan of size 1200mm Sweep, ISI marked, alongwith down rod lenth 26 Cm, antique brass look with electroplated blade, air delivery of 215 m3 / Hr, No of blades -4, fixed to ceiling and connecting up including provision of flexible 3 core copper cable & testing, smooth functioning at site complete all as specified and directed by the Engineer-in-Charge. Cat Part No Florence of Havells or equivalent in Orient / Philips or approved by GE.
Supply & fix in exhaust fan 150mm sweep, 1400 RPM plastic ABS body super silent below 42dB with automatic front opening with slitted gauard , No of blades-07, AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces complete all as directed by Engineer-in-Charge. Make- Cat Part No FHVVJAUSTF06 of Havells or equivalent in Orient/ Philips as approved by GE.
Supply & fix in exhaust fan 230mm sweep, 1400 RPM metallic body with louvers AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces complete all as directed by Engineer-in-Charge. Make-Orient/Havells/Usha
Supply & fix in Rigid non-metallic PVC casing caping/conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of medium grade, ISI mark, 25mm width double lock, for cable TV, internet, telephone cable complete all as directed by Engineer-in-Charge. Make of casing & capping- Preesfit, Precision
Supply and fix in modular single pole & neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amps complete with modular box & modular plate complete all as directed by Engineer-in-Charge. Make-Schneider/Siemens/Legrand
Supply & fix in Rigid non-metallic PVC casing caping/conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of medium grade, ISI mark, 25mm width double lock, for cable TV, internet, telephone cable complete all as directed by Engineer-in-Charge. Make of casing & capping- Preesfit, Precision
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip.
Material & labour for earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip32 x 6 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type C2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion. Note for similar items to be given :- (i) In case of similar items with different quoted rate are observed, the lowest quoted rate amongst all shall be considered and amount will be accordingly amended. The tenderer shall be note the above requirement & shall have no claim on this account (ii) The work is to be carried out at any heigh and rate quoted shall be deemed to be included necessary scaffolding and safety measures of labours as per latest labour laws
Idustrial products India
Nexus Infratech
MUKESH CONSTRUCTION CO
AGRAWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .