Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDEER | |
| 2 | L2₹51.9 L+₹2.7 L (5.55%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical 3 G M C MARKET G N B ROAD CHANDMARI KAMRUP ASSAM 781003 | KAMRUP METRO | ASSAM | 781003 | - | Rejected-Technical Due to adverse remarks in WLR | |
| 4 | Rejected-Technical | - | Rejected-Technical As the firm is not enlisted in appropriate category | |
| 5 | Rejected-Technical OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | - | Rejected-Technical As the firm is not enlisted in appropriate category |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Apr 2024, 6:00 pmClosed
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
PROVN OF INSTALLATION OF SMOKE/ FIRE DETECTION SYSTEM AT CSD DEPOT NARANGI UNDER GE GUWAHATI
2024_MES_641887_2
8739/GUW/E8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
Guwahati
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Guwahati
₹96,000
Yes
6 Nov 2024
6 Mar 2024
5 Apr 2024
6 Mar 2024
3 Apr 2024
13 Mar 2024
Amount
Supply, lnstallation, Testing & Commissioning of Intelligent, addressable microprocessor based multisensor detector with heat and smoke combination with both photoelectric/ thermal sensors with base and 360° view, 2 wire plug-in type with self testing features and built intelligence that incorporates optionally configurable advanced built-in-isolation, Tri-color detector-status with LED (Green flash with approx 10 second interval - Normal supervisory operation, smoke sensitivity is within rated limits; Yellow flash with approx 4 second interval- Detector is in trouble and needs replacement; Red flash with approx 1 second interval - Alarm condition; No flash - Detector is not powered). The detector should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - (i) The Detector must be compatible to the fire alarm control panel and other accessories described in the schedule (ii) The spacing between two detectors should be maintained 3.0 meter and spacing from side wall to detector should be mainteined 1.5 meter]
Supply, lnstallation, Testing & Commissioning of Response Indicator for above false ceiling detectors. The indicator should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - The Indicator must be compatible to the fire alarm control panel and other accessories described in the schedule]
Supply, lnstallation, Testing & Commissioning of Intelligent, addressable resettable type Manual Call Point or manual pull station complete with built-in loop isolation, Multi-color (tri-color) status LED, single action pull station in plastic housing that requires one action by the user to initiate the alarm. The device should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - The Manual call point must be compatible to the fire alarm control panel and other accessories described in the schedule]
Supply, lnstallation, Testing & Commissioning of Fire Alarm sounders / Sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5m with sound output variation of + 5 db 3.5 km range including manual/ auto start/ stop button, necessary cables to get connection from nearest point, suitable PCC foundation, pgi sheet protection cover and iron mesh cover to protect against monkey menace complete all as specified and as directed by Engr-in-Charge.
Supply, lnstallation, Testing & Commissioning of Intelligent, addressable Relay control module with addressable ‘Form C’ relay, built-in dual isolators, current rating up to 4 Amps with multi-color LEDs (Green flash with approx 10 second interval - Normal supervisory operation, smoke sensitivity is within rated limits; Yellow flash with approx 4 second interval- Device is in trouble and needs replacement; Red flash with approx 1 second interval - Alarm condition; No flash - Detector is not powered). The device should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - The device must be compatible to the fire alarm control panel and other accessories described in the schedule]
Supply, lnstallation, Testing & Commissioning of Intelligent Addressable Monitor module comprising of single-input interface module that can only monitor and report the status of a Normally Open (N.O.) or a Normally Closed (N.C.) contact with built-in dual isolators, multi-color LED. The device should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - The device must be compatible to the fire alarm control panel and other accessories described in the schedule]
Supply, Installation, Testing and Commissioning of Addressable fire alarm control panel (FACP) for 5 Loop Fire alarm Panel expandable upto 10 loops including suitable software and system hardware, Operating units, Periphery boards, Power supplies,System enclosures, Fully programmable through use of a Windows operating system y,Supports Class X Wiring suitable for maximum 2500 detector / device in any combination , 6-inch (15.2 cm.), backlit liquid-crystal display (LCD) Touch screen for maintenance operations and function keys, on-board 24 Hours battery backup with 30 min alarm condition and an Operating temperature range of 0°C to 49°C and a relative humidity of 93%, The Panel shall have power Surge Arrester to protect the for any unwanted surge. The panel should have suitable network interface card and capable to integrate with RS-485 network communications protocol.The panel should be complying with relevant IS standard with latest amendments and compliant to NFPA standard 72 The device should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - (i) The panel must be compatible to all accessories/ devices described in the schedule (ii) Necessary fixing arrangement of the panels and cables deemed to be included in the quoted rate (iii) Any accessories not specified but forming part of standard model of manufacturer deemed to be included in the quoted rate]
Supply, Installation. testing & commissioning of Repeater panel (SSD) System-Status LCD display unit with LED indicators that shows the local status of fire alarm control panel described at item Ser No 8 above. LED will illuminate when Alarm, Supervisory, Trouble and Security events occur on the system. Four-line LCD will give details of the event in alphanumeric form. The display can be toggled to display additional events. Provision for optional remote-system-control capabilities should be available. The panel should be complying with relevant IS standard with latest amendments complete all as specified and as directed by Engr-in-Charge. [Note: - The panel must be compatible to the fire alarm control panel and other accessories described in the schedule]
Supply, Installation. testing & commissioning of 24V 5A power supply unit with built in battery with 30 mnts backup for sounders complete all as specified and as directed by Engr-in-Charge. Make: Standard make as recommended by OEM of the Fire alarm system.
Supplying and Laying of 2 core 1.5 sqmm fire survival armoured cable, 600/1000V rated with stranded annealed copper conductor mica tape wrapped, FRLS inner sheathed, GI wire/ strip armoured having XLPE insulation complete all as specified and as directed by Engr-in-Charge.
Supplying and Laying of 2 core 4.0 sqmm fire survival armoured cable, 600/1000V rated with stranded annealed copper conductor, mica tape wrapped, FRLS inner sheathed, GI wire/ strip armoured having XLPE insulation complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable etc, in soft / loose soil including removing and refixing paver block complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand all as specified and as directed by the Engineer-in-Charge.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge.
Supply & laying of High density polyethylene pipes (HDPE) 40 mm of pressure rating 6 kgf/cm2 laid in trenches/ path/ road for laying of cable complete all as specified and directed by Engr-in-Charge.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road/path (Maximum 10 M in width) suitable for passing GI/HDPE pipe/ tubing of 40 to 80 mm bore incl necessary excavation and returning filling complete all as specified and directed.
M/s JK Jangid and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .