Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.1 L+₹1.3 L (3.48%)Rejected-Finance D 91 BLOCK D AMITY GREEN HASEMAU LUCKNOW PIN 226028 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226028 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.6 L+₹3.8 L (10.3%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L3 | Rejected-Finance Being L3 |
Tender Value
₹37.4 L
EMD Value
₹74,760
Closing Date
21 Sept 2024, 6:00 pmClosed
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Spl repairs for conversion and Re-routing of Old rusted CI pipe lines to DI double flanged pipe lines from PH No 02 to PH No 03 and allied works for external water supply at 39 GTC Varanasi Cantt.
2024_MES_654025_2
8723/E8
Open Tender
Civil Works
Item Rate
180 days
Varanasi
As Per NIT
6 documents required · 6 mandatory
₹500
GE (East) Prayagraj
₹74,760
Yes
14 Nov 2024
18 Jul 2024
28 Sept 2024
18 Jul 2024
21 Sept 2024
25 Jul 2024
Amount
Excavation in trenches in soft/loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,laying of pipes etc. not exceeding 10 sq m on plan and getting out complete all as specified and directed.
Returning, filling in excavated material, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L for for bore hole for passing DI Pipe of 150 mm dia under PCC road/ taxi track/ runway/ hard standing not less than 1200 mm deep complete all as directed. NOTES :- (i) Cost of equipments, tools & plants, material required for boring shall be deemed to be included in unit quoted rates above.
Taking up cast iron water mains (including all fittings), with flanged ends including disconnecting pipes and fittings complete all as specified and directed .
Material & labour for laying, jointing, commissioning & testing 150 mm dia Ductile iron welded double flanged Pipe centrifugally cast , class K-9 conforming to IS, in any length, jointing with rubber / fibre joints in trenches complete all as specified and directed.
Material & labour for Ductile iron fittings or special for flanged ends size up to 150 mm bore pipes conforming ti IS : 1538, like bends (any radious and angle ) taper any type ( Straight, end increasing, decreasing or double socket etc) tail pieces single branches, Ý' junction double branches,crosses (all flanged ends) complete all as specified & directed.
Supply & Fixing Sluice valve 150 mm bore heavy duty both ends flanged and drilled type nominal pressure rating PN 1.6 , Conforming to IS: 14846 complete with cast iron body bonnet wedge stuffing box with high tensil steel spindle cast iron hand operated wheel & Cap top nuts,bolts & washers including 6 mm thick rubber gasket joint complete all as specified and directed .
M&L construction of brick masonry valve pit of size 1050 mm X 1050 mm X 1050 mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified & directed.
Cutting of DI pipe 150 mm bore in position for insertion new tees, branch including the required length complete all as specified & directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in foundation/sub base complete all as specified & directed as per requirement by Engr-in-Charge.
M & L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates as in buttresses columns, pillars, boundary pillars and posts of any thickness, size or shape including form work, plasters, caps and bases etc as specified & directed as per requirement by Engr-in-Charge.
Matrubhoomi Construction (BID ID -3104803)
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3097026)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .