Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical technically not qualified |
| Sl No | Description | Qty | Unit | SALIEABS SOLUTIONS LLP L1 |
|---|---|---|---|---|
| 1.00 | Removal of Accumulated Sludge in Receiving Chamber ,Grid chamber,Primary Sedimentation tank ,Bio Arration tank,Secondary Clarifier and Chlorin tank with using of Mechanical Equipments ,And Men and Materials and All Safety measures like Gum Boot ,Hand Glouse with all Initial aspects etc complete as per standards and the direction of the Departmental officers etc complete | 5,580.41 | cum | 429 ₹23,93,997.28 Lowest |
| 2.00 | Supply and delivery and Fixing of 1 HP Monoblock Motor pump with ISO Quality as per standards and the direction of the Departmental officers etc complete. M-1063 (PWD SOR 25-26, Pg no-169) | 6 | each | 7,751 ₹46,506 Lowest |
| 3.00 | Supply and delivery and Fixing of 2 HP Monoblock Motor pump with ISO Quality as per standards and the direction of the Departmental officers etc complete. M-1064 (PWD SOR 25-26, Pg no-169) | 3 | each | 11,620 ₹34,860 Lowest |
| 4.00 | Supply and delivery and Fixing of Air blower 40 HP Motor (Squirrel Cage or Mono block type) with ISO Quality as per standards and the direction of the Departmental officers etc complete by replacing motor make Kirlosker,Speed 1440 rpm. M-2683 (PWD SOR 2025-26, Pg no 285) | 5 | Each | 4,37,500 ₹21,87,500 Lowest |
| 5.00 | Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40metres head to develop 3.5 kg/sq.cm at the heightest andfarthest hydrant point to make 30 m water jet at the time offire fighting emergency cicumstances, coupled with 11 KW /15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete antivibration mounting, rain safety hood and etc. complete asdirected by the Departmental Officers (Kirloskar make KDS1555+ or Equivalent) Each 54700.00 by replacing motor make KAY,Capacity 1020 cubic meter per minites, speed 1077 rpm. M-0778 (PWD SOR 2025-26 , Pg 136) | 2 | each | 1,46,000 ₹2,92,000 Lowest |
| 6.00FULL BORE ELECTROMAGNETIC FLOW METER WITH 5 YEARS WARRANTY. Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a selfdiagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished. | ||||
| 7.00 | 500 mm Electromagnetic flow meter [Inlet & Out let] [TWAD SOR 2025-26 Vol II, Page No.98] WD-M1400 | 2 | each | 4,03,000 ₹8,06,000 Lowest |
| 8.00 | 400 mm Electromagnetic flow meter [Inlet & Out let] [TWAD SOR 2025-26 Vol II, Page No.98] WD-M1398 | 1 | each | 3,05,000 ₹3,05,000 Lowest |
| 9.00Ductile Iron Socket/Spigot Pipes For Class K9, as per IS 8329/2000. (Twad SOR 2025-26, Pg no 39) | ||||
| 10.00 | 500mm WD-M0643 | 4 | M | 9,800 ₹39,200 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹1.5 L
Closing Date
18 Mar 2026, 3:00 pmClosed
commissioner
13,sendurai main rd,elil nagar,dindigul
AMRUT 2.0-Removing replacing and Reerection of All motors and Pumpsets and Blowers in STP ,Ponmandurai in Dindigul city municipal Corporation
2026_MAWS_674711_1
2855/2023/E4
Open Tender
Civil Works
Works
13, sendurai main rd, elil nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.5 L
13,sendurai main rd,elil nagar,dindigul
5 Jun 2026
14 Mar 2026
18 Mar 2026
14 Mar 2026
18 Mar 2026
14 Mar 2026
16 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Removal of Accumulated Sludge in Receiving Chamber ,Grid chamber,Primary Sedimentation tank ,Bio Arration tank,Secondary Clarifier and Chlorin tank with using of Mechanical Equipments ,And Men and Materials and All Safety measures like Gum Boot ,Hand Glouse with all Initial aspects etc complete as per standards and the direction of the Departmental officers etc complete | 5,580.41 | cum | - | - |
| 2 | Supply and delivery and Fixing of 1 HP Monoblock Motor pump with ISO Quality as per standards and the direction of the Departmental officers etc complete. M-1063 (PWD SOR 25-26, Pg no-169) | 6 | each | - | - |
| 3 | Supply and delivery and Fixing of 2 HP Monoblock Motor pump with ISO Quality as per standards and the direction of the Departmental officers etc complete. M-1064 (PWD SOR 25-26, Pg no-169) | 3 | each | - | - |
| 4 | Supply and delivery and Fixing of Air blower 40 HP Motor (Squirrel Cage or Mono block type) with ISO Quality as per standards and the direction of the Departmental officers etc complete by replacing motor make Kirlosker,Speed 1440 rpm. M-2683 (PWD SOR 2025-26, Pg no 285) | 5 | Each | - | - |
| 5 | Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40metres head to develop 3.5 kg/sq.cm at the heightest andfarthest hydrant point to make 30 m water jet at the time offire fighting emergency cicumstances, coupled with 11 KW /15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete antivibration mounting, rain safety hood and etc. complete asdirected by the Departmental Officers (Kirloskar make KDS1555+ or Equivalent) Each 54700.00 by replacing motor make KAY,Capacity 1020 cubic meter per minites, speed 1077 rpm. M-0778 (PWD SOR 2025-26 , Pg 136) | 2 | each | - | - |
| 6 | FULL BORE ELECTROMAGNETIC FLOW METER WITH 5 YEARS
WARRANTY. Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion
resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a selfdiagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished. | - | - | - | - |
| 7 | 500 mm Electromagnetic flow meter [Inlet & Out let] [TWAD SOR 2025-26 Vol II, Page No.98] WD-M1400 | 2 | each | - | - |
| 8 | 400 mm Electromagnetic flow meter [Inlet & Out let] [TWAD SOR 2025-26 Vol II, Page No.98] WD-M1398 | 1 | each | - | - |
| 9 | Ductile Iron Socket/Spigot Pipes For Class K9, as per IS 8329/2000. (Twad SOR 2025-26, Pg no 39) | - | - | - | - |
| 10 | 500mm WD-M0643 | 4 | M | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.89 MB
BOQ_810929.xls
BOQ • 0.33 MB
stpbiddocument.pdf
Tender Documents • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .