Providing LED street light, network(cable) and street light pole( RSJ) in Zone No. 1,18,19 and 20 under BMC, Bhopal. (Third Call)
2023_UAD_252816_3
2020212429
Open Tender
Electrical Works
Percentage
60 days
ISBT, Electric Section
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹12,500
₹99,810
19 Feb 2024
9 Aug 2023
24 Aug 2023
9 Aug 2023
23 Aug 2023
9 Aug 2023
Amount
Providing LED street light, network(cable) and street light pole( RSJ) in Zone No. 1,18,19 and 20 under BMC, Bhopal. (Second Call)
3000012331-XLPE aerial bunch 3x25 sq.mm, 1x16(st. light), 1x35(insulated neutral messenger) AS PER MP PWD SOR 2022
3000012329-XLPE aerial bunch Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS-14255- 1995, alu. alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below – Single core cable(insulated neutral messenger) 2x25 sq.mm, 1x16(insulated neutral messenger) AS PER MP PWD SOR 2022
3000012350-Piercing connector Main:50-150sq.mm, tap:6-50sq.mm AS PER MP PWD SOR 2022
3000012353-Spring loaded Supplying &fixing of spring loaded busbar screwless connector with enclosure of approved make including required clamp, nut, bolt, connection, testing as per specification to complete the job. Three Phase 1Ph 1in 8out AS PER MP PWD SOR 2022
3000001215-Clamp for Neutral Supply and installation of Clamp for Neutral
3000012347-Suspension clamp Supplying & fixing of aerial bunch cable accessories suspension clamp i/c required attachment for single core cable of approved make on pole with clamp, necessary material as per specification for required size. AS PER MP PWD SOR 2022
3000012348-Tension clamp Supplying &fixing of aerial bunch cable accessories tension clamp (dead end) i/c required attachment for single core cable of approved make in air with clamp, necessary material as per specification for required size. AS PER MP PWD SOR 2022
1000004963-30 watt LED Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass cover on existing electric pole. The fitting should be IP66, IK-08, with power factor >0.95 The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 10%. The total system output should be not less than 110 lumens/ watt. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 5 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass cover GI Pipe Bracket upto 2 Mtr Long in Required angle/shape etc. on stamp paper with service center details. LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before. Manufacturer must have in house NABL accredited Lab.
1000001873-45 watt LED Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass cover on existing electric pole. The fitting should be IP66, IK-08, with power factor >0.95 The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 10%. The total system output should be not less than 110 lumens/ watt. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 5 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass cover GI Pipe Bracket upto 2 Mtr Long in Required angle/shape etc. on stamp paper with service center details. LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before. Manufacturer must have in house NABL accredited Lab.
1000004964-60 watt LED Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass cover on existing electric pole. The fitting should be IP66, IK-08, with power factor >0.95 The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 10%. The total system output should be not less than 110 lumens/ watt. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 5 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass cover GI Pipe Bracket upto 2 Mtr Long in Required angle/shape etc. on stamp paper with service center details. LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before. Manufacturer must have in house NABL accredited Lab.
1000004965-90 watt LED Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass cover on existing electric pole. The fitting should be IP66, IK-08, with power factor >0.95 The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 10%. The total system output should be not less than 110 lumens/ watt. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 5 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass cover GI Pipe Bracket upto 2 Mtr Long in Required angle/shape etc. on stamp paper with service center details. LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be
Bidder Name
Amount
HEENA CONSTRUCTION COMPANY(GSTN-23AAYFM7973Q1ZZ)
PRASHANT ELECTRICALS(GSTN-23AABFP1106H1ZX)
HEENA CONSTRUCTION COMPANY
PRASHANT ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .