Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹31.5 L Quoted ₹32.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹37.2 L+₹5.1 L (15.8%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | ₹37.2 L+₹5.1 L (15.8%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹39.5 L+₹7.3 L (22.7%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹39.5 L+₹7.3 L (22.7%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹39.7 L+₹7.6 L (23.5%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹39.7 L+₹7.6 L (23.5%) | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
18 Jun 2024, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS AND MAINTENANCE OF WINDOW SPLIT TYPE ACs COLD STORAGE PLANTS DEHUMIDIFIERS REPAIRS TO FAN EXHAUST FAN AND OTHER SUMMER WINTER APPLIANCES AND CONNECTED EM WORKS AT DFRL MYSORE
2024_MES_653907_1
8505/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY c (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹92,000
Yes
22 Jul 2024
23 May 2024
25 Jun 2024
23 May 2024
18 Jun 2024
6 Jun 2024
23 May 2024 - 4 Jun 2024
Amount
Material and labour for servicing of Window / spilt type AC indoor/outdoor of capacity upto 3.0 Ton of any make, model and type complete all as specified and directed. NOTE :- (a) The quoted rate is deemed to be inclusive of checking of Electrical wiring and carrying out necessary repairs/replacement like with lugs, clamps, soldering, internal suitable copper wiring upto 5 m, etc. including Greasing and oiling of fan motor (b) The quoted rate is deemed to be inclusive of checking of refrigerant piping, drain pipes and carrying out necessary repairs/replacement to insulation to copper tubing. (c) The quoted rate is deemed to be inclusive of deep cleaning of air filter with soap water / foam complete and cleaning of the other connected parts as and when required. (d) Servicing shall have to be carried out in an interval of every 3 months (e) Other Spares like Capacitors, PCB Boards, etc will be paid separately under Supply only
Taking out AC 1.0/ 1.5/ 2.0 ton capacity(indoor & outdoor unit) of any make from its original location and transport to the nearest workshop removing the dust from body with blower cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black synthetic enamel paint and checking of all components/accessories for their serviceability and replacement of defective components/accessories complete and refixing it in its original place including commissioning and testing complete all as specified and directed by Engineer-in-Charge. NOTE :- (a) The quoted rate deemed to be inclusive of transportation within the city, cleaning and painting. (b) Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted. (c) Replacement of unserviceable items shall be measured and paid separately under relevant items as supply only (d) Refrigerant gas will be measured separately. (e) The quoted rate deemed to be inclusive of deploying well skilled labourers alongwith safety belts and scaffolding who are capable to relocate the outdoor unit at not less than 30 m over the building (f) The rate is deemed to be inclusive of brazing of cooling coils (g) The nitrogen gas required for testing of the unit is deemed to be included in the quoted rates
Supply only New Air filter suitable for existing Window / split type AC of capacities 1.5/2.0/3.0 TR complete all as specified and directed.
Supply only remote for 1.5 TR Split type AC all as specified and as directed
Supply only remote for 2.0 TR Split type AC all as specified and as directed
All as per Sl item No.3 above but supply only Running capacitor 36 MFD 230 volts, 50 Hz.
All as per Sl item No.3 above but supply only Running capacitor 45 MFD 230 volts, 50 Hz.
All as per Sl item No.3 above but supply only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz.
All as per Sl item No.3 above but supply only contactor 240 V up to 32 A
All as per Sl item No.3 above but supply only suction and discharge valve
All as per Sl item No.3 above but supply only Fan motor, single phase 230 Volts 1500 RPM
All as per Sl item No.3 above but supply only Blower Motor, single phase 230 Volts 1500 RPM.
All as per Sl item No.3 above but supply only New swing motor
All as per Sl item No.3 above but supply only PCB
All as per Sl item No.3 above but supply only Fan blade
All as per Sl item No.3 above but supply only cooling coil made out from seamless hard copper pipe including brazing and pressure testing by nitrogen gas to suit the existing model and make of ACs Note for Sl Item No. 3 to 16 :- (a) The spares are to be suited with the existing model of the AC's, makes of the existing AC's are Videocon, Voltas, LG, Hitachi, Samsung (b) The labour element for these items will be paid under Sl Item No. 1 or Sl item No. 2 as applicable.
Supply and fix in replacement of compressor (sealed unit) of capacity 1.5 Ton in exchange of unserviceable unit, suitable for installation in 1.5 Ton Split type Air Conditioner all as specified and as directed by Engineer-in-Charge. NOTE :- (a) Brazing, Vaccuming, Leak testing and gas charging for the units replaced with new compressor is deemed to be included in the unit rate quoted.
Supply and fix in replacement compressor (sealed unit) of capacity 2.0 Ton in exchange of unserviceable unit, suitable for installation in 2.0 Ton Split type Air conditioner all as specified and as directed by Engineer-in-charge NOTE :- (a) Brazing, Vaccuming, Leak testing and gas charging for the units replaced with new compressor is included in the unit rate quoted.
Supply and fix Extra length of PVC drain pipes of 20 mm bore with all accessories, clamped to wall / ceiling with necessary clamps for draining out condensed water from indoor / outdoor units as required and directed at site all as specified and as directed
Material and labour for removing the split type Air conditioner of capacities upto 3.0 Ton outdoor unit / indoor unit from its position for pressure / leak testing and arresting the leakages in condenser coil / cooling coil by brazing etc and gas charging as per required basis complete and shifting to new location as directed by Engr-in-charge. NOTE :- (i) Refrigerant Gas charging will be paid separately (ii) The quoted rate deemed to be inclusive of T&P required for making hole in the wall
Supply only copper refrigerant pipe copper tube of size 5/8'' x 3/8" including brazing and fixing with the Cold Room Unit / ACs / Water Cooler / Refrigerator / Deep freezer all as specified and as directed
All as per Sl item No. 21 above but copper refrigerant pipe copper tube of size 1/2'' x 1/4''
All as per Sl item No.21 above but copper refrigerant pipe copper tube of size 5/8'' x 1/4''. Note for Sl Item No. 21 to 23 :- (a) The spares are to be suited with the existing model of the AC's. Makes of the existing AC's are Videocon, Voltas, LG, Hitachi (b) The labour element for this item will be paid under their relevant items
Supply and filling/topping up/ charging of Refrigerant gas R-22 at the site complete all as specified and directed.
All as per Sl item No.24 above but refrigerant gas R -134A
All as per Sl item No.24 above but refrigerant gas R -32
Supply and fix in replacement of outdoor condensing unit of split type AC 1.5/2 TR capacity all as specified and directed. NOTE :- (a) The outdoor unit are to be suited with the existing model of the AC's. Makes of the existing AC's are Videocon, Voltas, LG, Hitachi (b) Irrespective of the model, makes of the AC's the condenser coils should be made up of copper only. (c) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Supply and fix in replacement of indoor unit of split type AC 1.5/2 TR capacity all as specified and directed. NOTE :- (a) The indoor unit are to be suited with the existing model of the AC's. Makes of the existing AC's are Videocon, Voltas, LG, Hitachi. (b) Irrespective of the model, makes of the AC's the condenser coils should be made up of copper only. (c) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Material and Labour for removing old rusted outdoor unit split air conditioner stand upto 2 TR from the existing site and supply and fix new stand suitable to the particular outdoor unit and location made out mild steel as per existing without distributing / damage to the copper piping etc all as per specified and directed.
Material and Labour for dismantling/taking out of water cooler for repairs such as repair/replacement of compressor. fan motor. tank repair etc of any makes and size, from any place, and any capacity, transported to workshop and back, complete all as specified and directed. NOTE :- (i) The quoted rate deemed to be inclusive of minor spare parts and MS work. (ii) Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Replacement of unserviceable/damaged items shall be measured and paid separately under relevant items
Dewatering the steel tanks of water cooler and cleaning of steel water tanks manually including scrubbing of the walls of the tank with Sodium carbonate or dish-washer detergent complete and all as directed NOTE :- Cleaning to be carried out on monthly basis
Material and Labour for dismantling/taking out of deep freezer / Refrigerator for repairs such as repair/replacement of compressor. fan motor. etc of any makes and size, from any place, and any capacity, transported to workshop and back, complete all as specified and directed. NOTE :-: (i) The quoted rate deemed to be inclusive of minor spare parts & MS work. (ii) Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (iii) Replacement of unserviceable/damaged items shall be measured and paid separately under relevant items
Supply only Compressor ( Sealed unit ) suitable for existing Water Cooler / Deep freezer / Refrigerator of various capacities complete all as specified and directed.
All as per Sl item No.33 above but Push type C.P. bib cock for water cooler.
All as per Sl item No.33 above but float valve PVC for water coolers as per sample.
All as per Sl item No.33 above but Running capacitor 25 MFD 230 volts, 50 Hz.
All as per Sl item No.33 above but Starting capacitor 60 to 80 MFD 230 volts, 50 Hz. Note for item no. 33 to 36 :- (a) The spares are to be suited with the existing model of the Water Coolers / Refrigerator . (b) The labour element for this item will be paid under Item No. 30 and 31
Supply and replacement of flexible core sheathed PVC insulated sheathed with multistranded copper conductor 2.5 sq.mm 3 core 600/1100 Volts, ISI Marked all as specified and as directed.
Supply and fix in replacement of voltage stabilizer of upto 5 KVA capacity single phase 230 Volts suitable for ACs / Water Cooler / Refrigerator of available make after disconnecting incoming and outgoing electric connections including testing by connecting on load and adjusting low/ high cut off and timing relay all as specified and as directed.
Servicing / overhauling to complete indoor/outdoor (Walk in Cold Storage plant of Capacity 20000 BTU & Walk in Frezzes ) labour only for overhauling and servicing whole chamber, blowing out the dust, rectifying the problems, checking of interlock of safety/ control device, checking of all electrical connections in unit, refrigerant pipe lines, renewal of all corroded sheet metal screws, servicing of blowers, cleaning of evaporator coils washing with chemicals with forced feed method to remove the dust from the coil and filters, greasing the fan including leak testing of the total refrigerant system of plants by pumping down the refrigerant to cylinder, flushing out the entire system arresting all leakages by replacing the damaged flare nuts, taflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas ( N-2) under constant pressure of 250 - 300 PSI , watch the pressure for 24 Hrs for confirmation tightening the nuts bolts complete all as specified and directed by EIC. Note : (a) Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (b) The quoted rate deemed to be inclusive of replacement of all minor spares and testing equipments (c) All the major spares parts will be measured and paid separately und relevant items (d) The servicing and testing of the Cold storage / Walk in freezer plant equipments needs to be carried out in once in three months
Supply only low and high pressure cut out suitable for existing Cold Storage facilities / Walk in Freezer of capacities 20000 BTU complete all as specified and directed.
All as per Sl item No. 41 above but Temperature controller suitable for cold storage plant upto 4 (+/-2) degree celsius complete all as specified and as directed.
All as per Sl item No. 41 above but Temperature controller suitable for Walk in Freezer upto (-) 20 (+/-2) degree celsius complete all as specified and as directed.
All as per Sl item No. 41 above but Door Lock and Door Bedding arrangements
All as per Sl item No. 41 above but Contactor 3 phase, 415 V . Note for item no.41 to 45 :- (i) The spares are to be suited with the existing model of the Cold Storage / Walk in Freezer . Makes of the existing Cold Storage / Walk in Freezer are Blue Star / Rinac. (ii) The labour element for this item will be paid under Item No. 40
Supply and fix in replacement compressor (sealed unit) reconditioned compressors as per sample, suitable for cold storage plant upto 4 (+/-2) degree celsius and of capacity 20000 BTU complete all as specified and as directed. NOTE :- Brazing, Vaccuming, Leak testing and gas charging for the units replaced with new compressor is included in the unit rate quoted.
Supply and fix in replacement compressor (sealed unit) reconditioned compressors as per sample, suitable for walk in freezer plant upto -20 (+/-2) degree celsius and of capacity 20000 BTU complete all as specified and as directed. Note: (a) Brazing, Vaccuming, Leak testing and gas charging for the units replaced with new compressor is deemed to be included in the unit rate quoted.
Comprehensive maintenance/ servicing of dehumidifiers of make BRY Air, model FRB 1800 after dismantling, opening of external covers, opening and removal of filter bank, heater banks and gear box, checking, cleaning and defect rectification of all internal parts for minor faults and replacement of same, refixing all the dismantled accessories including testing etc. complete all as specified and as directed. NOTE :- (a) Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted. (b) The quoted rate deemed to be inclusive of replacement of minor spare parts. (c) The servicing is to be carried out in every 03 months.
Supply and fix refrigeration capacity split type 20,000 BTU/Hr, Outdoor unit - with SS Casing and axial fans, outdoor unit - blue star Air cooled condenser with Hermetic reciprocating compressor, Digital temperature indicator cum controller, provided LED type existing 415 volts, 50Hz 3 phase, 32 Amps 4 pole MCB with Earthing incoming product temp (+) 20 to (+) 25 Deg C complete including testing and commissioning all as specified and directed. Input Parameters : Ambient Temperature : > 45°C Desired Temperature : < 4°C (± 2) Note : (a) The outdoor unit are to be suited with the existing model of the Refrigerating Unit. Make of Existing Unit : Blue Star, Rinac (b) Irrespective of the model, makes of the Outdoor Unit the condenser coils should be made up of copper only (c) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Supply and fix refrigeration capacity split type 20,000 BTU/Hr, indoor unit - with SS Casing and axial fans, outdoor unit - blue star Air cooled condenser with Hermetic reciprocating compressor, Digital temperature indicator cum controller, provided LED type existing 415 volts, 50Hz 3 phase, 32 Amps 4 pole MCB with Earthing incoming product temp (+) 20 to (+) 25 Deg C complete including testing and commissioning all as specified and directed. Input Parameters : Ambient Temperature : > 45°C Desired Temperature : < 4°C (± 2) Note : (a) The indoor unit are to be suited with the existing model of the Refrigerating Unit. Make of Existing Unit : Blue Star, Rinac (b) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Supply and fix refrigeration capacity split type 12000 BTU/Hr, Outdoor unit - with SS Casing and axial fans, outdoor unit - blue star Air cooled condenser with Hermetic reciprocating compressor, Digital temperature indicator cum controller, provided LED type existing 415 volts, 50Hz 3 phase, 32 Amps 4 pole MCB with Earthing incoming product temp (+) 20 to (+) 25 Deg C complete including testing and commissioning all as specified and directed. Input Parameters : Ambient Temperature : > 45°C Desired Temperature : < (-) 20°C (± 2) Note : (a) The outdoor unit are to be suited with the existing model of the Refrigerating Unit. Make of Existing Unit : Blue Star, Rinac. (b) Irrespective of the model, makes of the Outdoor Unit the condenser coils should be made up of copper only. (c) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Supply and fix refrigeration capacity split type 12000 BTU/Hr, indoor unit - with SS Casing and axial fans, outdoor unit - blue star Air cooled condenser with Hermetic reciprocating compressor, Digital temperature indicator cum controller, provided LED type existing 415 volts, 50Hz 3 phase, 32 Amps 4 pole MCB with Earthing incoming product temp (+) 20 to (+) 25 Deg C complete including testing and commissioning all as specified and directed. Input Parameters : Ambient Temperature : > 45°C Desired Temperature : < (-) 20°C (± 2) Note : (a) The indoor unit are to be suited with the existing model of the Refrigerating Unit. Make of Existing Unit : Blue Star, Rinac (b) Non-CFC Refrigerant gas is only to be used in the replaced unit. The rate is inclusive of the refrigerant gas charging as required initially.
Repair to geyser including taking down geyser by emptying and removing nut bolts disconnecting electrically, making the dead weight on top of geyser free, cleaning of thermostat and heating element and repairs to container if required and refixing geyser in its position after repairs Note : Spares required for repairs / replacement will be measured and paid separately under relevant items of work
Supply only Heating element 2 KW suitable for Horizontal / Vertical geyser of 50 litres capacity,
Supply only Heating element 1.5 KW suitable for Horizontal / Vertical geyser of 25 litres capacity,
Supply only thermostat, minimum 300 mm long, suitable for any make and type of geyser 25 / 50 litres capacity horizontal or vertical type all as specified and directed.
Supply only thermal cut out for geysers of any make and type of geyser 25/50 litres capacity horizontal or vertical type all as specified and as directed.
Supply only indicating lamp LED type for Horizontal / Vertical geysers of any type make and capacity all as specified and directed .
Taking down the ceiling fan/Exhaust fan/Wall mounted fan of any size, sweep, model complete and refixing the fan with twin flexible cord wire from the ceiling rose and testing after replacing the wornout and defective parts complete all as specified and as directed. Note : Spares will be paid and measured separately under relevant items
Supply only Bearing of suitable size of ceiling fan/exhaust fan/wall mounted fan.
Supply only Bush of suitable size of ceiling fan/exhaust fan / wall mounted fan
Supply only Capacitor 2.5/4 MFD for ceiling fan/exhaust fan / wall mounted fan
Rewinding of ceiling fan/exhaust fan / wall mounted fan with suitable gauge of enemelled copper wire with suitable class of insulating varnish, of any size and sweep complete all as specified and as directed
Material and labour for Painting of ceiling fan/exhaust fan / wall mounted fan any type with 2-coats of enemelled paint after filling cavities complete all as specified and as directed
Supply and fix in replacement sheet metal enclosures with socket plug top Double pole and neutral enclosure with two pin and earth plug and socket complete with 20 Amps, 240 Volts, 'C' Curve MCB Complete all as specified and directed.
Supply and fix in replacement sheet metal enclosures with socket plug top Triple pole and earth enclosure with a three pin and earth plug with socket complete with one Triple pole 32 Amps 415 Volts, 'C' Curve MCB Complete all as specified and directed.
Supply and fix in replacement of sheet metal enclosures with socket plug top Triple pole and earth enclosure with a three pin and earth plug with socket complete with one Triple pole 63 Amps 415 Volts, 'C' Curve MCB Complete all as specified and directed.
Taking down old unserviceable aluminium sub main wiring, material and labour for sub main wiring complete with 2 runs of 6 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including PVC non metallic rigid conduit/casing caping of suitable size and conduit accessories run on surface of wall / ceiling etc and connecting terminal ends including 1 run of 4 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth dolly complete all as directed.
All as per item No 68 above but sub main wiring complete with 2 runs of 4 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 1 run of 4 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor complete all as specified and as directed
All as per item No 68 above but sub main wiring complete with 4 runs of 6 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, including 1 run of 6 sqmm PVC insulated un-sheathed copper conductor cable green colour as continuous earth continuity conductor complete all as specified and as directed
RRK PROJECTS
SREEKRUPA ENTERPRISES
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .