Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-Finance | ₹1.8 L | L1 | Accepted-Finance Least one |
| 2 | L2₹2.1 L+₹23,836.23 (13.1%)Accepted-Finance | ₹2.1 L+₹23,836.23 (13.1%) | L2 | Accepted-Finance Second Least |
| 3 | L3₹2.2 L+₹34,807.20 (19.1%)Accepted-Finance 26 10B KRISHNAPURAM KADAIYANALLUR TENKASI TALUK TENKASI 627 759 | TENKASI | TAMIL NADU | 627759 | ₹2.2 L+₹34,807.20 (19.1%) | L3 | Accepted-Finance Highest one |
| Sl No | Description | Qty | Unit | K Rajamohammed L3 | JANAKIRAM PRASATH L1 | NAVASKHAN L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing in position of Alu. Anodised Partition with 62x38x2mm extruded box section at bottom vertical and horizontal members. The vertical member are spaced at 90 cm c/c and to horizontal members are spaced at 1.2M, 2.1M and 2.4M height the bottom panels should be covered with 12 mm thick PLB exterior grade and the top and middle panels should be fixed at 4mm thick glass thick glass with necessary glassing clips.rubber beading, etc., including necessary dismantling holes in RCC columns, beams masonry wherever necessary with power power drill ti the extent required and made good to the original conditions after fixing as directed by the departmental officers. All the Aluminium sections should be anodised to 1.5microns as per ISI specification 1868/1962. | 25 | Sqm | 3,816 ₹95,400 | 3,204.5 ₹80,112.5 Lowest | 3,624.1 ₹90,602.5 |
| 2.00 | Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug | 5.8 | Sqm | 8,314.5 ₹48,224.1 | 6,983 ₹40,501.4 Lowest | 7,897.35 ₹45,804.63 |
| 3.00 | Supply and Delivery of 1 PHASE UPS (Single Phase In & Single Phase Out) 1 Kva CAPACITY - SYSTEM WITH BATTERY - 2 HOURS BACK-UP | 1 | Nos | 37,365 ₹37,365 | 31,374 ₹31,374 Lowest | 35,482 ₹35,482 |
| 4.00 | Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % | 1 | Nos | 24,275 ₹24,275 | 20,389 ₹20,389 Lowest | 23,059 ₹23,059 |
| 5.00 | Supply and delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE
CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER | 26 | Rm | 151 ₹3,926 | 125 ₹3,250 Lowest | 141.5 ₹3,679 |
| 6.00 | Supply and Delivery of pipe and Specials including cost and conveyance of all materials to site etc,complete 20mm PVC Pipe | 38 | Rm | 201.2 ₹7,645.6 | 169 ₹6,422 Lowest | 190.7 ₹7,246.6 |
| 7.00 | 20mm PVC Elbow | 12 | Nos | 10.7 ₹128.4 | 9 ₹108 Lowest | 9.95 ₹119.4 |
Tender Value
₹2.5 L
EMD Value
₹2,500
Closing Date
22 Sept 2026, 3:00 pmClosed
Municipal Commissioner
444, Thiruvengadam saali, Sankarankovil
Providing Main Stock Room and Biometric Weaste Room at Meeran Sait Colony PHC in Sankarankovil Municipality
2026_MAWS_699633_1
0746/2026/E1
Open Tender
Civil Works
Works
45 days
Sankarankovil Municipality
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹2,500
24 Sept 2026
31 Aug 2026
22 Sept 2026
31 Aug 2026
22 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing in position of Alu. Anodised Partition with 62x38x2mm extruded box section at bottom vertical and horizontal members. The vertical member are spaced at 90 cm c/c and to horizontal members are spaced at 1.2M, 2.1M and 2.4M height the bottom panels should be covered with 12 mm thick PLB exterior grade and the top and middle panels should be fixed at 4mm thick glass thick glass with necessary glassing clips.rubber beading, etc., including necessary dismantling holes in RCC columns, beams masonry wherever necessary with power power drill ti the extent required and made good to the original conditions after fixing as directed by the departmental officers. All the Aluminium sections should be anodised to 1.5microns as per ISI specification 1868/1962. | - | Sqm | 1.25 | - |
| 2 | Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug | 1 | Sqm | 1.25 | ₹1.25 |
| 3 | Supply and Delivery of 1 PHASE UPS (Single Phase In & Single Phase Out) 1 Kva CAPACITY - SYSTEM WITH BATTERY - 2 HOURS BACK-UP | - | Nos | 1.25 | - |
| 4 | Supply and delivery of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % | - | Nos | 1.25 | - |
| 5 | Supply and delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE
CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER | - | Rm | 1.25 | - |
| 6 | Supply and Delivery of pipe and Specials including cost and conveyance of all materials to site etc,complete 20mm PVC Pipe | - | Rm | 1.25 | - |
| 7 | 20mm PVC Elbow | - | Nos | 1.25 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_841040.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .