Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC AOC | |
| 2 | L2₹3.5 L+₹868 (0.25%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹3.7 L+₹25,851 (7.49%)Rejected-Finance | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹6,614
Closing Date
6 Nov 2021, 12:00 pmClosed
EE_KCED_PWD
Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_A_3rd_Floor_Kokata_700087
Renovation of EI and Installation of Air conditioning system at newly created chamber of Chemical Examiner 1st floor of Chemical Examination Laboratory Kolkata SITC of Air conditioning system
2021_PWDE_345990_1
WBPWD/EE/19/IR/T/KCED/II of 2021-22
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
46 Christopher Road
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,614
Office_of_EE_KCED_PWD
19 May 2022
29 Sept 2021
8 Nov 2021
29 Sept 2021
6 Nov 2021
8 Oct 2021
8 Oct 2021
Amount
VARIABLE REFRIGERANT FLOW SYSTEM : Supply of Variable Refrigerant Flow modular type air-conditioning system with DIP-IPM Inverter Controlled with step-less modulation complete with indoor & outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping , full charge of R-410 refrigerant gas & oil, control cabling etc. SUPPLY OF VRF OUTDOOR UNIT: Supply of Top Discharge Heat Pump Type Outdoor units equipped with highly efficient 100% full inverter scroll compressors with special heat exchanger, 27 Steps speed controle DC motor condenser fan , newly design special type heat exchanger ( Heating -20deg C to 15deg C) ( Cooling -5deg C to 52deg C) Self Demand function, auto chck function for connection error , auto address setting & in built Double Stage Oil Separater to ensure minimum oil entrenchment & proper lubrication. Minimum COP should be 3.75 at ARI conditions at 100% Load condition. 990 Steps 11Hz ~ 110Hz of compressor control by 0.1Hz. The condensing units should be capable for outside ambient 52˚C. (Make- Hitachi ) a) 8 HP Heat Pump Type
Hi-Wall Type : a)Supply of 2.0 HP Hi-Wall Type Indoor Unit with following Specification : i) IDU Power supply- AC 1ph, 230V/50Hz., ii) Nominal Cooling Capacity- 19800 Btu/hr, iii) Nominal Heating Capacity- 21200 Btu/hr, iv) Maximum Sound Pressure Level- 48 db, v) Maximum Air Flow Rate- 585 CFM
Multikit (Approved Brands – Hitachi) a)Supply of Y-shape Multikit Joints sizes as mentioned below. Multikit is consist of 2 nos copper joints and 2 nos separate insulation suitable for these Joints
Installation of VRF air-conditioning system of following items Lifting, Shifting, Installation, testing & Commissioning of Top Discharge type Outdoor units as follows : a)8 HP Heat Pump Type
Indoor Units : Lifting, Shifting, filter section & Installation, testing and commissioning of Indoor units address setting and capacity as mentioned below. Multi speed motor, coil section with DX coil. A)Hi-Wall Unit- 2.0 HP
Commissioning of VRF systems including Nitrogen Flushing etc.
Installation, Testing & Commissioning of Multikit Joints
Providing and fixing rigid PVC piping complete with fittings, supports as STD. & specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Make: Supreme , Astral , Finolex) a)25 mm dia
Supply & fixing of control cum distribution wiring of Copper conductor cable of size 2 C X 0.75 Sq. mm along with conduit for looping between indoor & outdoor VRF system & to main Central remote controller system
Supply and testing of R410 Gas Charging Top Up
Supply and fixing of 8" cable tray suitable to lay of VRF copper piping.
Refrigerant Piping : Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger. (Make: Rajco / Mandev) a)19.1 mm O.D. (with19 mm insulation )
b)15.9 mm O.D.(with 13mm insulation )
c)12.7 mm O.D.(with 13mm insulation )
d)9.5 mm O.D.(with 13mm insulation )
e)6.3 mm O.D.(with 13mm insulation )
Charges for M.S. Structure for ODU installation. The work including supplying fabrication & fixing of MS Structure with U channel of 6 mm thick of size ( 75 mm X 40mm X 40mm) for making 1.2 mtr X 1 mtr. platform supported from wall by 3 nos leg and inclined support from proper distance from wall bellow the structure for providing extra support to the structure for carring the load of the structure as well as the weight of the out door unit properly. Safety Railling (width-20mm, thick-4mm) should be provided at all side of the structure for safety of the maintenance personel incl. necy welding & painting etc. complete work should be carried out as per direction of E.I.C.
SKY DECORATIONS PRIVATE LIMITED
ELECTRIC REFRIGERATION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .