| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.4 L+₹39,640 (1.89%)Rejected-AOC KERNI MARKET COURT ROAD UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.0 L+₹1.0 L (4.93%)Rejected-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.0 L+₹1.0 L (4.96%)Rejected-AOC G 704 SUNCITY HEIGHTS LADHOUT ROAD SECTOR 36A ROHTAK HARYANA 124001 INDIA | ROHTAK | HARYANA | 124001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹22.0 L+₹1.0 L (4.98%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
27 May 2021, 6:00 pmClosed
GENORTH UDHAMPUR
GENORTH UDHAMPUR
Repairs to roof false ceiling and other misc works etc of CH NC FHO and AMSD under AGE B of GE North Udhampur
2021_MES_439675_1
GE/U(N)-12/2021-22
Open Tender
Civil Works
Item Rate
180 days
GENORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GENORTH UDHAMPUR
₹48,000
Yes
22 Jun 2021
1 May 2021
29 May 2021
1 May 2021
27 May 2021
13 May 2021
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engr-in-charge
Pre-painted coloured corrugated profiled Galvalume /Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), including gap filling between sheet and wall with PCC 1:3:6 as per site requirement complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, or on ridge fixed with self tapping screws as specified
Dismantling wall/ceiling board, fibre pulp insulation etc or insulation boards/slabs/blanks of any description, any thickness including over as directed by Engr-in-charge
S&F false ceiling with Everest Fibre Cement Designer tile Ivory/white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 595mmx595mm and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on interlocking powder coated certra black pattern metal grid of hot dipped galvanised steel sections (galvanised @120 gms, both sides inclusive) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0..30mm thick sheet and cross T of size 15x32mm made of 0.30mm sheet spaced between main T at 600mm c/c from a grid of 600x600mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers grils, light suspended from ceiling using GI soffit cleats fixed to existing rafters, purlin etc with dash fastners GI adjustable rods of 3mm dia wit galvanised butterfly level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centre black pre-painted with polyester painnt and having a load bearingcapacity of 12 kg/sqm and refixed all exesting electric wiring and fixture all complete at all heights as per directed
S & F for 5mm thick lnsulated PVC Wall Lining honeycombed as per sample kept in GE office consisting of PVC Insulated Panels with approved colour and design printed PVC sheet used colour PVC sheet duly fitted into the wall including PVC sheet in strips feathered at the edges including removing and refixing electric switch boards & plates and covered with PVC stripes or beading after fixing wall panelling as per specifications Complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified and as directed by Engr-in-charge
M&L Brick work with sub class 'B' bricks, straight or curved on plan, exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified.
ditto but except bricks only complete all as specified and as directed by Engr-in-charge
Providing plain cement concrete 1:2:4, type B-0 using 12.5 mm graded crushed stone aggregates as in cills, steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneelers, apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engr-in-charge
M&L for rendering 15 mm thick in cement mortor 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M&L for peparation of new surfaces and applying two coats of cement base paint on external wall surface over one coat of exterior primer and applying putty as required complete all as specified.
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. of any size in section complete all as specified.
S&F Steel work in tubular Post/ trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed by Engr-in-charge
S & F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including Chequered plates and plain plastes of any thickness and distance pieces, cleats etc conforming to Fe-410- W(Gde-E-250) quality- B complete all as specified and directed
Preparation of steel surfaces of any description over 10cm width or girth not other wise describe, two coat of synthetic enamel paint and over one coat of red oxide primer complete all as specified and as directed by Engr-in-charge
Roughing surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3.50 Kg/ sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound and the sand used for the same will be clean and free from any silt, organic matter and impurities. RCC and plastered surface will be wet cured for minimum period laid down in IS 456 & then allowed to dry and leakage checked by pointed test atleast 72 hrs. After checking of leakages on dry surfaces applying bituminous primer on roof surfaces @ 0.40 kgs/sqm on plastered surface on sunny day. After the primed surface has dried and apply a coat of hot blown 85/25 penetration grade blown bitumen confirming to IS-702 @ 1.20 kg/sqm on the surface provided APP (Atactic Polypropylene polymer) modified polymeric five layered membrane with central core 100 micron high molecular high density film. Minimum weight of membrane will be 3.00kg /sqm. APP membrane will be laid across the slope from lowest line slopping roof towards ridge with minimum end lap of 150mm & side lap of 75mm bonded with hot blown bitumen. Over the membrane apply semi hot blown 85/25 penetration grade bitumen 1.2kg/sqm and blinded with fine sand in dry condition 0.5kg/sqm dusted over the bitumen coat complete all as specified. Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer.
Supply only water prrofing compund complete all as specified and as directed by Engr-in-charge
Preparation of new surface and Applying two coat of Aluminium paint and over one coat of aluminium primer over bitumen membrane complete all as specified.
Demolition of plain cement concrete below or above ground level n exc 15 cm thickness and removal of soil to outside MD land complete all as specified and as directed by Engr-in-charge.
M&L 75mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring etc, complete all as specified and as directed by Engr-in-charge.
Demolition Stone slabs and tiles laid dry or dry beded or pointed of any description or thickness in floors, aprons etc complete all as specified and as directed by Engr-in-charge
M&L for plain cement concrete tiles coloured designer interlocking paver of 30mm thick having glossy finish, colour and pattern as approved by Engr-in-charge strength not less than 350 Kg/Sqcm (tested as per IS 1237-1980) laid over and including 50mm thick dry river sand cushioning and voids filled with dry sand and surface compacted with surface vibrator complete all as per manufacturer instructions, specified and as directed by Engr-in-charge.
S&F factory made heavy duty full body digital matt finish, paving coloured tiles of size 300mm x 300mm x 10mm thick for external use laid over and including 15mm thick screed bed or bedding layer in CM 1:4 including jointed with neat cement slurry and pointed in coloured tile epoxy grout to match the shade of tiles complete all as specified.
kerni electricals
TULSI RAINA AND SONS
Bansal and Sons
Alishan Builders
VARDHMAN INTERNATIONAL
M/S GURU DEV BUILDERS
JOGINDER SINGH
NARESH KUMAR KHAJURIA
sohtra and co
R K BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .