₹50,000
Closing Date
24 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
MAINTENANCE, REPAIR AND REPLACEMENT OF DEFECTIVE ITEMS OF LT DISTRIBUTION SYSTEM IN VIMAN NAGAR, 509 AND 1020 AREA AND 9 BRD AT AF STN PUNE
2020_MES_380391_2
8405/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹50,000
Yes
23 Jan 2021
9 Nov 2020
26 Nov 2020
9 Nov 2020
24 Nov 2020
11 Nov 2020
60 days
Amount
Disconnecting of incoming / outgoing ACSR conductor/ cables and GI earthing wire and dismantling of existing unserviceable LT pole any size / type and removing unserviceable LT pole from the PCC foundation in necessary earth work complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed.
Dismantling / taking out insulator of any size / type from existing electric LT lines complete all as specified and directed.
Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as specified and directed.
Disconnecting of incoming / outgoing cables and earthing lead and taking out existing unserviceable outdoor feeder pillar box / Panel and removing unserviceable pillar box / Panel with frame from the PCC foundation complete all as specified and directed.
Taking down Old unserviceable LT UG cable of service connection or distribution system of any size and removing from site complete all as specified and directed. NOTE : ( Excavation and earth work will be measured seperately)
Supply & fix pole cap made out of MS including two coat of aluminium paint over one coat of red oxide paint suitable for 8.5 / 9.0/ 11.0 mtr long tubular pole including threaded hole 2 Nos and suitable size of nut and bolts complete all all as specified and directed.
Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed.
Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete all as specified and directed.
Ditto all as per Ser Item No.10.00 above but single phase and neutral conductor.
Felling/trimming of trees not exc 30 cm girth including cutting of upper portion of branches and disposal of same at a distance not exc 50 mtr and clearing of site complete all as specified and directed. (Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.)
Removing LT over head conductor from insulator where ever required and restretching the same without any kink / bend upto premissible sag, binding it on insulator by means of binding wire including fixing line seprator at 3 places where required and directed and testing LT over head line on completion and complete all as specified and directed. Note:- 1.Three runs of LT over head conductor for phase, one run of LT over head conductor for neutral shall be measured & paid as one length. 2.Line seprator shall be measured and paid seperately.
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed.[Make : MS Seal / Reychem / Denson]
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 50 mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed.
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of pole complete all as specified and directed.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc. complete all as specified and directed.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc. complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc complete all as specified and directed.
Supplying,Laying and jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed for following size:-
10 sqmm 2 core
16 sqmm 2 core
16 sqmm 4 core
25 sqmm 4 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc. complete all as specified and directed.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 10 cm after laying and stretching jointing and testing the cable complete all as specified and directed. [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75) mm complete all as specified and directed.
Supply and fix in repair / replacement of MCCB FP 400 Amps 50 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 200 Amps 25 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 160 Amps 25 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 100 Amps 16 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix in repair / replacement of MCCB TP 63 Amps 16 KA including connections and testing for proper functioning complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix MCB TPN 240 V, 32 Amps. complete all as specified and directed.
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as specified and directed.
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and directed.:-
Copper bus bar 300 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.
MCCB FP 200 Amps 25 KA - 01 No for main incoming
MCB 40 Amps TPN, 10 KA - 06 Nos
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and directed.:-
Copper bus bar 300 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.
MCCB FP 200 Amps 25 KA - 01 No for main incoming
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and directed.:-
Copper bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.
MCCB FP 400 Amps 35 KA - 01 No for main incoming
MCCB TP 250 Amps 25 KA - 02 No
MCCB TP 100 Amps 25 KA - 02 No
MCCB TP 63 Amps 16 KA - 01 No
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following complete all as specified and directed.:-
Copper bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.
MCCB FP 400 Amps 50 KA - 01 No for main incoming
MCCB TP 250 Amps 25 KA - 01 No
MCCB TP 100 Amps 25 KA - 02 No
MCCB TP 63 Amps 16 KA - 03 No
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified and directed.
N AND G CONSTRUCTION
metro electrical services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .