Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹12.0 L+₹52,479.25 (4.57%)Rejected-Finance 5C H M APARTMENT SATI JAYMATI ROAD ATHGAON KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.0 L+₹56,646 (4.94%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.1 L+₹67,003.50 (5.84%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹12.2 L+₹75,891.50 (6.61%)Rejected-Finance HENGRABAI LICHUBAGAN BYE LANE 2 HOUSE NO 2 GUWAHATI 781036 ASSAM | KAMRUP METRO | ASSAM | 781036 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
4 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
REPAIR/MAINT OF HT AND LT NETWORK SYSTEM AND ITS CONNECTED WORKS AT CDA GUWAHATI UNDER GE GUWAHATI
2024_MES_649768_1
8743/GUW/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Guwahati
₹20,000
Yes
6 Nov 2024
10 Apr 2024
6 May 2024
10 Apr 2024
4 May 2024
24 Apr 2024
Amount
Materials and labour for carrying out periodical maintenance two pole/ four pole structure of 11 KV distribution system including replacing of damaged / rusted bolts, nuts, greasing to all moving parts of GOD/ AB switch, tightening of all loose bolts, applying petroleum gelly to AB switch contact, checking and tightening of earth connections, tightening of brackets, clamps and crimping of Jumpers etc., complete for one set GOD all as specified and directed. Note: Required tools & plant including lifting arrangement etc., shall be included in the rate quoted.
Materials and labour for replacement of silica gel of breather including providing silica gel as per the existing size / model complete all as specified and directed.
Supply & Fixing in replacement of complete breather assembly with silica gel, screwing and making threads on existing size of the transformer 50 KVA-200KVA complete all as specified and directed.
Materials and labour for replacement of temperature gauge as per the existing size / model complete all as specified and directed.
Materials and labour for removing the burnt out/ damaged LV bushes with porcelain insulator and replace with Brass LV bushes; nuts, check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity 100 to 200 KVA complete all as specified and directed.
Materials and labour for removing the burnt out/ damaged HV bushes with porcelain insulator and replace with Brass HV bushes, nuts, check nuts, rubber washer etc complete as per the existing size /model, for transformers of capacity 100 to 200 KVA complete al as specified and directed.
Supply and fixing gasket (set of four) for ceramic bushing on LT side of suitable size, shape and specification complete for capacity 100 to 200 KVA, 11/0.433 Volts transformers complete all as specified and directed.
Supply and fixing top cover gasket set of suitable size, shape and specification complete for capacity 100 to 200 KVA, 11/0.433 Volts transformers complete all as specified and directed.
Dehydration and filtration of transformer oil of transformers capacity ranging from 100 KVA to 200 KVA (11/0.433 KV) on site at different locations with filtration machine in order to achieve desired Di-electric strength of oil upto 60KV maximum at 2.5 mm gap complete all as specified and directed.
Supply & filling up of transformer oil conforming to IS-335 of 1993 up to desired level complete all as specified and directed. [Note: Dielectric strength of oil should not be less than 60KV complete all as specified and directed.] (Make: POWER OIL/SERVO/CASTRO/GULF or equivalent as approved by GE)
Supply and fixing of lightning arrester high tension of 11000 V grade expulsion type complete with all fittings, transmission class, discharge capacity 65KA including taking down of old complete all as specified and directed.
Materials and labour for Galvanised Iron strip of size 32mm x 6.0mm with saddles and fixing screw etc. for earth continuity conductor including taking down of unserviceable complete all as specified and directed.
Taking out unserviceable HT cable jointing kit of any cross sectional area with Connections and joints from cable, complete all as specified and directed.
M&L for Cable End Jointing Kit Indoor Termination Cold Shrinkable type complete with Jointing materials with all accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed.
M&L for Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed.
Cutting of green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the Fencing, removing rubbish from the Site of Work and depositing where directed not exc. 100 Metre from the starting Point, complete all as specified and directed. NOTE: The Item shall be operated maximum 4 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
Material and labour for painting to steel tubular pole 11.0 metre long with two coats of synthetic enamel paint up to 1.50 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with aluminium paint including numbering of pole No. by stensils and MS frames like channel, clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet of size 25x20cm, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolts and nuts of approved size for HT poles including taking out old unserviceable danger notice plate complete all as specified and directed.
Taking down/dismantling old/rusted/broken steel poles/struts, removing from site and making good disturbed surface complete all as specified and directed.
Supply, fixing and erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 (using 40mm graded stone aggregates) for foundation and coping with PCC 1:2:4 (using 20mm graded stone aggregates) and finishing the surface even and smooth complete all as specified and directed.
Material and labour in replacement street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape, fixing for LT steel poles with flat iron clamps 40mm x 6 mm - 02 sets including nuts, bolts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down of old unserviceable complete all as specified and directed.
M&L in replacement street light bracket made out of 32 mm dia two Nos. Gl pipe medium grade 120 cm long cut to size and bend to shape, fixing for LT steel poles with flat iron clamps 40mm x 6mm - 04 sets for fixing two LED light including nuts, bolts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down of old unserviceable complete all as specified and directed.
Material and labour for replacement of junction boxes with new Thermoplastic Cable Junction Boxes IP66/67 "weather proof, for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable of Size 155 X 210 X 92 mm including busbar fixed in repairs and including necessary civil works and connecting all incoming and outgoing wires with aluminium lugs of appropriate sizes complete all as specified and directed.
Material & Labour for fabrication of Sheet metal enclosure, powder coated of Timelite Distribution Boards TIMELITE-40A, 3P, 240V Digital time switch for automatic Switching of street lights internally pre wired by using suitable lugs including fixing with MS Clamp 40 X 5mm to steel/RCC poles including connection comprising of the following:- (i) Digital time switch 24 hrs operation 240 Volts (ii) 3 pole contactor 40Amps (iii) MCB FP 40 Amps
Material and labour for painting to steel tubular pole 9.00 metre long after scrapping of old painted surface with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30cm alternative black and yellow strips and remaining portion including MS frames like channel clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
Material and labour for painting of pole number using stensils of letter size 75mm height with white synthetic enamel paint over black background complete all as specified and directed.
Taking down LT/HT UG Cables of any size from trenches/poles/wall complete after disconnection all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm, 3.5 core complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 3.5 core complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm, 3.5 core complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor conforming to IS:7098 (Part 11), 11 KV earthed grade, cross sectional area 95 sq mm 3 core complete all as specified and directed.
M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L for 50 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc., or for shafts, wells, cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L for providing sand cushioning to UG cable, 8 cm thick laid before laying of cable and 15 cm thick after laying of cable punned down to total thickness of 18 cm in trenches with clean dry sand of approved quality, suitable for sand cushioning complete all as specified and directed. Note: Punned thickness only shall be measured and paid.
Supply and laying in trenches brick common burnt clay building brick, sub class 'B' designated-75 for cable protection complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded aggregates) as in foundations, filling in and mass concrete complete all as specified and directed.
Supply and fixing MCCB 400Amps, 415 volt, AC 50 Hz, 4 pole, 50 KA with thermal magnetic release, adjustable over load and short circuit conditions complete all as specified and directed.
Supply and fixing MCCB 250 Amps, 415 volt, AC 50 Hz, 4 pole, 36 KA with thermal magnetic release, adjustable over load and short circuit conditions complete all as specified and directed.
Supply and fixing MCCB 200 Amps, 415 volt, AC 50 Hz, 4 pole, 36 KA with thermal magnetic release, adjustable Over load and short circuit settings to be fitted in existing LT panel complete all as specified and directed.
Material & labour for carrying out repairs to the IPFC/APFC Panels including servicing/replacing worn-out nuts, bolts, cable lugs, connecting wires, markers, insulating sleeves, repairs to PCC foundation etc and replacement of power capacitors with equal or higher capacities, capacitor switching duty contactor, suitable APFC Relay, HRC Fuse links, TPN/TP of required amp, CT/PT etc all as specified and directed. Note: Replacement of power capacitor, capacitor switching duty contactor and IPFC/APFC Relay will be measured separately but cost for the rest items required to make the IPFC/APFC controller functional to achieve best result should deem to be included in the rate.
Supply and fixing in replacement of Power factor correction Capacitor super heavy duty of following capacities complete all as specified and directed:-
1 KVAR, Cylindrical Type
2 KVAR, Cylindrical Type.
3 KVAR, Cylindrical Type.
4 KVAR, Cylindrical Type.
5 KVAR, Cylindrical Type
7.5 KVAR, Cylindrical Type
10 KVAR, Cylindrical Type
15 KVAR, Cylindrical Type
Supply and fixing in replacement 3Ø 415 V 50 HZ Capacitor switching duty contactor suitable upto 50KVAR rating of type MO C 25 complete all as specified and directed.
S & F in replacement of Intelligent/Automatic power factor controller suitable for Banks upto 8 steps size 144x144 with 1/3 CT input having auto programming function IPFC CS 1003-308-90 V/ 550 Vac for 50/25 KVAR IPFC complete all as specified and directed.
Taking down old unserviceable earthing of any type including all its accessories complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to Gl earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to Gl earth strip 32 x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed.
M/s JK Jangid and Company
Purbanchal Construction Co
M/S. SUBHAS CONSTRUCTION CO.
S and B Electricals
KUNDAN ENGINEERS AND BUILDERS
PURBANCHAL BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .