Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.3 L+₹1.6 L (16.0%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.1 L+₹2.3 L (23.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.9 L+₹3.2 L (32.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹13.6 L+₹3.8 L (38.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S SHEIKH FEROOZ AHMAD L2 | M/S N A Enterprises L5 | M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR L3 | YATTOO ENTERPRISES L4 | JK BUILDERS AND ENGINEERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, jointing and testing in repairs XPLE insulated, armoured heavy duty electirc cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core in trenches, through pipe, under culvert or in air complete all as specified and directed. | 250 | RM | 450 ₹1,12,500 | 300 ₹75,000 | 385 ₹96,250 | 320 ₹80,000 | 200 ₹50,000 Lowest |
| 2.00 | All as per item Ser No 01 above but 95 Sqmm 3.5 Core | 200 | RM | 600 ₹1,20,000 | 500 ₹1,00,000 | 500 ₹1,00,000 | 450 ₹90,000 Lowest | 500 ₹1,00,000 |
| 3.00 | All as per item Ser No 01 above but 120 Sqmm 3.5 Core | 150 | RM | 650 ₹97,500 | 650 ₹97,500 | 350 ₹52,500 Lowest | 550 ₹82,500 | 350 ₹52,500 Lowest |
| 4.00 | All as per item Ser No 01 above but 150 Sqmm 3.5 Core | 120 | RM | 750 ₹90,000 | 700 ₹84,000 | 400 ₹48,000 Lowest | 650 ₹78,000 | 400 ₹48,000 Lowest |
| 5.00 | All as per item Ser No 01 above but 185 Sqmm 3.5 Core | 90 | RM | 850 ₹76,500 | 850 ₹76,500 | 420 ₹37,800 Lowest | 850 ₹76,500 | 500 ₹45,000 |
| 6.00 | S&F in repairs LT Busbar panel board, outdoor type door cubical type, slopy roof front back both side opening, pedastal mounted overall size not less than 600 x 450 x 25mm, CPRI approved, IP-54 having independent compartment for bus bar, incoming feeder and each outgoing feeders dust and vermin proof and lockable, factory made fabricated out of 3.15mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with 4 Nos aluminium bus bar of 150 Amps rating for 3 phase and bus bar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set including necessary copper cables of suitable size for MCCB/ inter connections, common earth bus bar of GI strip 32 x 6mm at bottom with independent plates at bottom for each outgoing and incoming cables in cabel alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing all accessories :-
NOTES :-
(a) All MCCBs will be measured and paid separately under relevant item of this schedule.
(b) Rates of interconnecting copper/ aluminium cable along with necessary copper/ aluminium lugs are inclusive in the quoted rate.
(c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval/ Layout/ Drawing/ General arrangements for panel from AGE (I) prior to commencement of work.
(d) Cost for connecting of existing old underground cable of any size/ type to new incoming/ outgoing terminals by cutting the required length. Addition/ altration and provision of necessary cable lugs, cable glands, nuts & bolts etc shall be included in the quoted rates. | 15 | Each Job | 8,500 ₹1,27,500 | 25,000 ₹3,75,000 | 15,000 ₹2,25,000 | 16,000 ₹2,40,000 | 4,000 ₹60,000 Lowest |
| 7.00 | M&L Earthing complete with GI earth plate of size 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below normal ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, protection pipe 15mm dia light grade upto 7.5mtr and salt etc. and connected to earthing test point including dismantling of old unserviceable earthing and taking out material, complete all as specified and directed including testing after completion. | 15 | Each Set | 3,000 ₹45,000 | 3,000 ₹45,000 | 3,800 ₹57,000 | 3,200 ₹48,000 | 1,500 ₹22,500 Lowest |
| 8.00 | S&F MCCB 4 pole, current rating 400 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity of 16 KA at 415 V, 50 Hz, complete all as specified and directed. | 15 | Each | 10,000 ₹1,50,000 Lowest | 10,000 ₹1,50,000 Lowest | 17,000 ₹2,55,000 | 16,000 ₹2,40,000 | 15,000 ₹2,25,000 |
| 9.00 | All as per item No 08 above but 4 pole 200 Amps having breaking capacity 36 KA | 3 | Each | 5,000 ₹15,000 Lowest | 7,000 ₹21,000 | 7,500 ₹22,500 | 8,500 ₹25,500 | 11,000 ₹33,000 |
| 10.00 | All as per item No 08 above but 4 pole 160 Amps having breaking capacity 36 KA | 4 | Each | 10,000 ₹40,000 | 5,500 ₹22,000 Lowest | 5,500 ₹22,000 Lowest | 6,500 ₹26,000 | 6,500 ₹26,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Sept 2025, 6:00 pmClosed
Cdr, HQ 134 Wks Engrs
HQ 134 WE C/o 56 APO PIN-914134
REPAIR MAINT OF LT EXTERNAL ELECTRICAL WORKS MCCBs WITH PANEL UG CABLE OF SECTOR A OF SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2025_MES_728398_1
134 WE-60(T)/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
AGE (I) CIF (K)
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹40,000
10 Oct 2025
29 Aug 2025
27 Sept 2025
29 Aug 2025
25 Sept 2025
12 Sept 2025
29 Aug 2025 - 5 Sept 2025
Amount
Supply, laying, jointing and testing in repairs XPLE insulated, armoured heavy duty electirc cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core in trenches, through pipe, under culvert or in air complete all as specified and directed.
All as per item Ser No 01 above but 95 Sqmm 3.5 Core
All as per item Ser No 01 above but 120 Sqmm 3.5 Core
All as per item Ser No 01 above but 150 Sqmm 3.5 Core
All as per item Ser No 01 above but 185 Sqmm 3.5 Core
S&F in repairs LT Busbar panel board, outdoor type door cubical type, slopy roof front back both side opening, pedastal mounted overall size not less than 600 x 450 x 25mm, CPRI approved, IP-54 having independent compartment for bus bar, incoming feeder and each outgoing feeders dust and vermin proof and lockable, factory made fabricated out of 3.15mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with 4 Nos aluminium bus bar of 150 Amps rating for 3 phase and bus bar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set including necessary copper cables of suitable size for MCCB/ inter connections, common earth bus bar of GI strip 32 x 6mm at bottom with independent plates at bottom for each outgoing and incoming cables in cabel alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing all accessories :- NOTES :- (a) All MCCBs will be measured and paid separately under relevant item of this schedule. (b) Rates of interconnecting copper/ aluminium cable along with necessary copper/ aluminium lugs are inclusive in the quoted rate. (c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval/ Layout/ Drawing/ General arrangements for panel from AGE (I) prior to commencement of work. (d) Cost for connecting of existing old underground cable of any size/ type to new incoming/ outgoing terminals by cutting the required length. Addition/ altration and provision of necessary cable lugs, cable glands, nuts & bolts etc shall be included in the quoted rates.
M&L Earthing complete with GI earth plate of size 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below normal ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, protection pipe 15mm dia light grade upto 7.5mtr and salt etc. and connected to earthing test point including dismantling of old unserviceable earthing and taking out material, complete all as specified and directed including testing after completion.
S&F MCCB 4 pole, current rating 400 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity of 16 KA at 415 V, 50 Hz, complete all as specified and directed.
All as per item No 08 above but 4 pole 200 Amps having breaking capacity 36 KA
All as per item No 08 above but 4 pole 160 Amps having breaking capacity 36 KA
All as per item No 08 above but 4 pole 100 Amps having breaking capacity 16 KA
Supply, fixing & laying in repairs GI pipe light grade 50mm bore in trench, under floor, wall and on pole for cable protection, complete all as specified and directed.
Excavation in trenches, in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cables, erection of poles, stays etc. and getting out, complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removal of surplus excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
Sand cushioning to under ground cable using fine sand (8cm before & 15cm after laying of cable) complete all as specified and directed. NOTE :- Punned thickness shall be measured and paid.
Brick sub class 'B' of standard size for protection of cable, brick laid across the cable complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 60 watt 230 Volts AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 90 watt 230 Volts AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply and fixing in repairs LED street light fitting 120 watt 230 Volts AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
NOTE :- An amount of Rs. 38000.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S SHEIKH FEROOZ AHMAD (BID ID -3428224)
M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR (BID ID -3429375)
YATTOO ENTERPRISES (BID ID -3428698)
M/S N A Enterprises (BID ID -3429329)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .