Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.4 LAccepted-AOC | 1 | Accepted-AOC ACCEPTED BEING L-1 | |
| 2 | 2₹9.4 L+₹57,913 (6.59%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING L-1 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
16 Dec 2019, 6:00 pmClosed
AGE (I) CIF (R)
AGE (I) CIF (R), PIN-934756, c/o 56 APO
REPAIR/MAINT OF TRANSFORMER/DG SET, VOLTAGE STABILIZER, INTERNAL ELECTRIFICATION WORKS AT HQ POTHA AND ANCILLARY UNITS
2019_MES_276630_1
AGE(I)/R-65/2019-20
Open Tender
Miscellaneous Works
Item Rate
365 days
POTHA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,800
Yes
6 Feb 2020
18 Nov 2019
21 Dec 2019
18 Nov 2019
16 Dec 2019
2 Dec 2019
Amount
PART-I (E&M Works)
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 2 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 35Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. NOTE:(Earth work, brick protection and sand cushioning shall be measured and paid for separately). Make: Finolex/Havells/Polycab
GI tubing light grade 80 mm bore for fixing along the pole / wall including fixing clamps, bolts, nuts made of GI flat strip of size 40x4mm etc for protection of cable complete all as specified and directed . Make: Jindal/Prakash Surya/Tata
GI tubing light grade 50 mm bore for fixing along the pole / wall including fixing clamps, bolts, nuts made of GI flat strip of size 40x4mm etc for protection of cable complete all as specified and directed . Make: Jindal/Prakash Surya/Tata
GI tubing light grade 40 mm bore for fixing along the pole / wall including fixing clamps, bolts, nuts made of GI flat strip of size 40x4mm etc for protection of cable complete all as specified and directed . Make: Jindal/Prakash Surya/Tata
Aluminium cable thimbles of size 120 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 95 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 50 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 35 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 25 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 16 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Aluminium cable thimbles of size 10 Sqmm for UG Cable including connection and crimping in replacement complete all as specified and directed . Make : Jaipuriya/Rastriya/Dowells
Electronic driver (Printed circuit board) suitable for 150 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
Electronic driver (Printed circuit board) suitable for 120 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
Electronic driver (Printed circuit board) suitable for 90 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
Electronic driver (Printed circuit board) suitable for 80 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
Electronic driver (Printed circuit board) suitable for 45 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
LED panel suitable for 150 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
LED panel suitable for 120 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
LED panel suitable for 90 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
LED panel suitable for 80 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
LED panel suitable for 45 watt LED street/flood light fitting input voltage 230 Volt 50 HZ AC in replacement complete all as specified and directed . Make : Havells/CG/Bajaj. Note : The make of electronic driver should be match with the make of LED light fitting installed at site and the contractor should visit the site before quoting the rates so as to avoid the ambiquity during execution stage.
Endura Cylinder Neo / Neo N 120W Neo N 5700K, New generation energy & environment friendly long life Versatile pressure die -cast aluminium IP66 roadway luminaire with high power LED as light source complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed . Make: Havells Cat Part No. LHETAXU7PA6J120 or eqivalent in Philips/Crompton.
Off load change over switch 400 Amps 415 volts 4 pole, 50 Hz in sheet metal enclosure with out side handle operated and fixed including taking down old, complete all as specified and directed . Make: Seimens/Havells/Control & switchgear/ABB
Off load change over switch 250 Amps 415 volts 4 pole, 50 Hz in sheet metal enclosure with out side handle operated and fixed including taking down old, complete all as specified and directed . Make: Seimens/Havells/Control & switchgear/ABB
Off load change over switch 200 Amps 415 volts 4 pole, 50 Hz in sheet metal enclosure with out side handle operated and fixed including taking down old, complete all as specified and directed . Make: Seimens/Havells/Control & switchgear/ABB
Off load change over switch 100 Amps 415 volts 4 pole, 50 Hz in sheet metal enclosure with out side handle operated and fixed including taking down old, complete all as specified and directed . Make: Seimens/Havells/Control & switchgear/ABB
On load change over switch 125 Amps 415 volts 4 pole, 50 Hz open execution type with rotary type handle operated and fixed including taking down old, complete all as directed. Make: Seimens/Havells/Control & switchgear/ABB
On load change over switch 100 Amps 415 volts 4 pole, 50 Hz open execution type with rotary type handle operated and fixed including taking down old, complete all as directed. Make: Seimens/Havells/Control & switchgear/ABB
On load change over switch 63 Amps 415 volts 4 pole, 50 Hz open execution type with rotary type handle operated and fixed including taking down old, complete all as directed. Make: Seimens/Havells/Control & switchgear/ABB
MCCB 4 pole adjustable type 250 Amps, repturing capacity 36 KA for 415 volts including taking down old MCCB, complete all as specified. Make: Seimens/Havells/Control & switchgear/ABB
MCCB 4 pole adjustable type 200 Amps, repturing capacity 36 KA for 415 volts including taking down old MCCB, complete all as specified. Make: Seimens/Havells/Control & switchgear/ABB
MCCB 4 pole adjustable type 160 Amps, repturing capacity 36 KA for 415 volts including taking down old MCCB, complete all as specified. Make: Seimens/Havells/Control & switchgear/ABB
MCCB 4 pole adjustable type 100 Amps, repturing capacity 36 KA for 415 volts including taking down old MCCB, complete all as specified. Make: Seimens/Havells/Control & switchgear/ABB
Supply and fix in replacement stop solenoid 12V 10 amps single coil 75mm dia complete all as specified. Cat part No - 02.477.01.0.00
Dismantling and taking out self starter assembly suitable for 62.5 KVA DG Set and replacement of wornout spare parts like field coil, armature assembly, solenoid assembly, corbon brush, corbon brush assembly, clutch plate assembly and bushes including serviceing and refixing to engine complete all as specified and directed .
Supply and fix replacement generator control unit KG541 level-0 complete all as specified. Cat part No - D8.048.07.0.00
Dismantling and taking out battery charging alternater assembly suitable for 62.5 KVA DG Set and replacement of wornout spare parts like field coil, rotor assembly, corbon brush, rectifier assembly and bushes etc including serviceing and refixing complete all as specified and directed .
Supply and fix replacement exhaust fan (450mm) with connectorcomplete all as specified. cat part No -D8.079.26.0.00
Dismantling and taking out fuel injector pump assembly suitable for 62.5 KVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector 'O' rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified and directed .
Supply and fix in replacement Self starter assembly 12V suitable for 62.5 KVA DG Set complete all as Specified and directed. Make MICO/LUCAS/BOSCH
Supply and fix in replacement Banded cogged belt (2JAX51-LP-1326) complete all as specified and directed . Cat part No - 06.032.03.0.00
Supply and fix in replacement V Belt (A-47) 1227 length complete all as specified and directed. Cat part No - 04.140.01.0.00
Supply and fix in replacement Fuel pipe (7.5, 14x14B, 700 PB) complete all as specified and directed. Cat part No - 34.151.04.0.00
Supply and fix in replacement Silencer assembly complete all as specified and directed. Cat part No - 48.318.10.0.00
Supply and fix in replacement Rubber hose for air intake complete all as specified and directedC cat part No - 48.464.02.0.00
Diconnecting the input and output electric supply from automatic voltage stabiliser of any capacity and taking out from site and shifting to civil workshop Rajouri (about 70 KMs away from Surankote) for carrying out repair works. Note:- The rate quoted by the contractor shall incude the rate for T&P, transportation and necessary men power required during loading and unloading.
Opening the top cover of votage stabiliser taking out the complete servo stabiliser oil and keep it for reuse and taking out dimmer assembly and transformer assembly for checking the defects and carrying out the following repairs:-
Supply and fix in replacement Dimmerstate unit of capacity 50 KVA servo voltage stabilizer 28 amps of Make Volina complete all as specified and directed.
Supply and fix in replacement main transformer of capacity 50 KVA servo voltage stabilizer of make Volina complete all as specified and directed.
Supply and fixing in replacement Electronic circuit board (Printed circuit board) for controlling of synchronous motor of torque 10 KG and auto/manual under voltage high voltage operation complete all as specified and directed.
Supply and fix in replacement PCB holder complete all as specified and directed.
Supply and fixing in replacement trigger transformer complete all as specified and directed.
Supply and fixing in replacement panel lamps alongwith connecting leads for over voltage under voltage etc.complete all as specified and directed.
Supply and fix in replacement corbon brush complete all as specified and directed.
Supply and fix in replacement digital volt meter 72 x 72 mm complete all as specified and directed.
supply and fixing in replacement servo motor 10 KG torque complete all as specified and directed.
Supply and fixing in replacement RC network for 10 KG servo motor complete all as specified and directed.
Supply and fix in replacement auto manual switch complete all as specified and directed.
Dimantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp 02 nos with rubber reel complete all as specified and as directed.
Supply and fixing in replacement of ball bearing of size 6200 to 6204 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. . Make :- NBC/SKF
Dimantling and taking out Exhaust fan 230 volts 200 to 450mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes complete all as specified and as directed.
Supply and fixing in replacement heating element any shape of capacity 1.5/2 KW 230 volt AC supply for electric storage type water heater complete all as specified and directed. Make:- Racold/Bajaj/Havells.
Supply and fix in replacement inner MS water storage tank suitable for 15 ltr storage type water heater complete all as specified and as directed.. Make:- Racold/Bajaj/Havells.
Supply and fix in replacement inner MS water storage tank suitable for 25 ltr storage type water heater complete all as specified and as directed.. Make:- Racold/Bajaj/Havells.
Supply and fix in replacement inner MS water storage tank suitable for 50 ltr storage type water heater complete all as specified and as directed.. Make:- Racold/Bajaj/Havells.
Supply and fix in replacement Thermostat of capacity suitable for 1.5/2 KW 230 volt AC supply for electric storage type water heaters complete all as specified and as directed.
Taking down old and UNSV transformer at different locations in the area of responsibility falls under AGE(I) CIF (R ) from two pole strcture/ foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed at site of following capacity transformer:- 25 to 100 KVA
Taking down old and UNSV transformer at different locations in the area of responsibility falls under AGE(I) CIF (R ) from two pole strcture/ foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed at site of following capacity transformer:- 101 to 200 KVA
Replacement of burnt defective HT/LT copper coil of different type capcity winding with superior qulity enamelled copper winding wire/strips of approved of suitable size/guage and Nos of turns maching with the existing impendence and insulated including all allied materials such as cork sheets, fiver glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make/type/capacity in repairs all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make/type/capacity in repairs all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity in repairs complete all as specified and directed
Supply and fixing in replacement Dehydrating breather assembly CI body of standard size filled with silica-gel for transformer of capacity upto and including upto and including 200 KVA in repairs complete all as specified and directed
Supply and fixing in replacement Temperature gauge circular dia type of standard size for transformer of capacity upto and including upto and including 250 KVA in repairs complete all as specified and directed
Material and labour for filling in with new transformer oil for top up having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 40 KV(after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol
Supply & fixing in replacement of Dehydration including filtration of transformer oil on different locations by dehydration plant including testing of samples before and after dehydration and fiteration complete all as specified and directed the dielectric strength to be achieved 40 KV at 4 mm gap after complete dehydration.
Air break gang operated triple pole mechanically operated mounted on HT insulators and galvanised steel frame with operating rod of 25mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt 50 Hz including 12 insulator and drop out fuse carrier element all as specified and directed by Engineer-in-charge.
Expulsion fuse single pole upto 25 amps 11000 volts complete all as directed by Engr In Charge.
Air break switch insulators (set of three) for 11000 volts suitable for current rating 200 amps complete all as directed by Engr In Charge.
Lightening arrestor expulsion type complete with all fittings, transmission class discharge capacity 65 Kilo amps suitable for 11000 volt including taking down old uncerviceable complete all as specified and direted by Engineer-in-Charge.
Dismantling of 62.5 KVA DG Set complete engine like head, valve tappet, nozzle, valve guide, piston, cylinder, cylinder liner, connecting rod, crank shaft, cam shaft and lubricant system and replacing the spare parts as required and re-installation at the original location including all necessary connections , connecting to alternator, including commissioning and testing complete all as specified and directed. Note: (i) Spare parts will be measured and paid separately as supply only. (ii) The quoted rate shall included the Labour element required for fixing of new spare parts under relevant Items here-in-after. (iii) The rate quoted by the contractor shall include the rate for fixing of cylinder head valve guide/valve seat, Con rod bush fitting and crank shaft grinding/main bearing fitting.
Supply only the following spare parts for fixing under Serial Item No -2 here in before. Note: All spare parts shall be Make of Kirloskar to suit the Model of DG Sets and to be procured from the authorised dealer.
Bearing T/W KIR HA 394 cat part No - W.073.7.00.003 or as suitable at site as per direction of Engineer-in-Charge.
Bearing main HA 694 Cat part No - M.075.4.00.023 or as suitable at site as per direction of Engineer-in-Charge.
Bearing C/R KIR HA 694, 0.50, (Nick) cat part No - B.075.4.10.023 or as suitable at site as per direction of Engineer-in-Charge.
Bearing bush S/E KIR HA 694 cat part No - S.075.5.00.703 or as suitable at site as per direction of Engineer-in-Charge.
Bearing C/bush KIR HA 394 cat part No - C.073.6.00.003 or as suitable at site as per direction of Engineer-in-Charge.
Lubricant pump assembly cat part No - 06.010.60.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Oil seal (115 x 140 x 12) CR make cat part No - 03.007.06.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Oil seal (65 x 85 x 13) CR make cat part No - 03.013.06.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Set of rubber 'O' rings (HA 694) cat part No - 06.051.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Set of joints (HA 694) cat part No - 06.050.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Piston complete cat part No - 02.182.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Cylinder liner cat part No - 02.183.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Pair of inlet and exhaust valve (US tier 1) cat part No - 02.445.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Valve guide cat part No - 02.022.17.0.00 or as suitable at site as per direction of Engineer-in-Charge.
valve tappet cat part No - 02.024.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
valve collect cat part No - 02.022.12.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Thermostat element (74 Deg) WTIL No.DEV358 cat part No - 39.040.09.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Nozzele leak off pipe cat part No - 06.819.20.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Fuel pipe (7.5, 14x14B, 700 PB) cat part No - 34.151.04.0.00 or as suitable at site as per direction of Engineer-in-Charge.
KOEL care super genuine oil 20 liters Can Cat part No - 82.050.10.0.20 or as suitable at site as per direction of Engineer-in-Charge.
1.1 liter fuel filter kit cat part No - 48.040.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Lub oil filter element cat part No - 06.040.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Valve spring cat part No - 02.022.13.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Cap assembly cat part No - 34.036.60.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Lube oil pressure sensor (sensor+switch), VDO Siemence(India), 2 terminal, body ground with imported bobin assembly cat part No - 2H.092.11.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Precoated drain plug cat part No - 2H.035.02.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Set of copper washers cat part No - 4H.087.30.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Valve seal cat part No - 06.631.02.0.00 or as suitable at site as per direction of Engineer-in-Charge.
washer cat part No - 02.022.04.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Cylinder head bolt 12x211 cat part No - 02.022.03.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Push rod (welded) cat part No - 02.024.70.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Con rod bolt cat part No - 02.021.04.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Hose for air inlet monifold cat part No - 06.260.03.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Fuel pipe 8.0, 14 B 1000 WB cat part No - 36.040.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Leak off pipe 1000mm long cat part No - 48.112.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Rocker lever assembly cat part No - 02.024.50.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Starter ring 121 teeth 3.175 module cat part No - 03.035.02.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Bush for injector cat part No - 02.035.08.0.00 or as suitable at site as per direction of Engineer-in-Charge.
L.O. supply hose (FIP) M10 banjo ends x 235 L cat part No - 4H.006.01.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Oil spray nozzele assembly cat Part No - 02.002.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Con rod assembly (without) LE bearing) cat part No - 04.685.20.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Fuel pipe (9.5I.D x 4000L) cat part No - 06.610.03.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Expantion bellow assembly 3" cat part No - 06.602.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Anabond
Fuel level sensor height 225mm cat part No- DV0.802.15.0.00 or as suitable at site as per direction of Engineer-in-Charge.
4-20mA lube oil pressure sensor gems make 3100 series cat part No - Dvo.812.11.0.00
Silencer assembly cat part No - 48.318.10.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Rubber hose for air intake cat part No - 48.464.02.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Kirloskar green AVR for alternator 62.5 KVA DG set (Model: TAVR-10/TAVR-20/TAVR-14) cat part No - 2H.811.32.0.00 or as suitable at site as per direction of Engineer-in-Charge.
Supply and fixing in replacement air filter element cat part No - CC1.006.008.0.00
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified.
Removing excavated material (soils) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 95 Sqmm,complete all as specified.
PART-II (Schedule of Credit) Amount of credit of Rs. 40135.00 for retrieved material mentioned in Sch `A' Part-IIof tender documents in PDF form which will be deducted offline during acceptance of tender.
M/S NARAYAN CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .