Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹8.7 L+₹2.1 L (31.1%)Rejected-AOC | L2 | Rejected-AOC Higher Rate |
Tender Value
Refer Docs
EMD Value
₹13,220
Closing Date
26 Jun 2024, 5:00 pmClosed
Executive Engineer, PHE Division No.1, Narnaul
Executive Engineer, PHE Division No.1, Narnaul
Providing and fixing concertina coil and supply of lab equipment at Canal Based Water Works Lehroda for running the water supply smoothly and all other works contingent thereto
2024_HRY_380756_1
SE PHE Circle NNL No. 98 dt. 05-01-2024
Open Tender
Civil Works
Works
30 days
Narnaul
Please refer tender Notice
4 documents required · 4 mandatory
₹1,000
₹13,220
Yes
10 Oct 2024
20 Jun 2024
26 Jun 2024
20 Jun 2024
26 Jun 2024
20 Jun 2024
Amount
Providing anf fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length fixed on existing angle iron Y shaped placed at existing boundary wall. With 5 horizonyytal R.B.T reinforced barbed wire studtied with G.I. staples and G.I.clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete as per direction of Engineer-in-charge .
Turbidity meter of make HACH Range: 0-4000 NTU; Certification: CE, FCC, EC, EN, UL STD Communication: RS 232, USB via adapter Compliance: ISO Data Log: 1000 total logs, includes reading log, verification log and calibration log, Date Time, User Display: LCD graphic, backlit, menu controlled Interface: RS 232, USB via adapter, external printer, barcode scanner, PC Light source: Light-emitting diode (IR LED)/ Tungsten Filament Lamp Measurement method: Nephelometric Operating temperature range: 0 - 50 °C Power requirements (Voltage): 100 - 240 VAC with Lab station, Battery Operated 4 x 1.5 V, type AA for approx. 3,000 measurements Resolution: 0.001 NTU; Repeatability ±1% of reading or 0.01 NTU whichever is greater Accuracy: ± 2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU or better Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure Regulatory: Meets ISO 7027, DIN EN 27027 Response time: <15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries) Dimension 236 x 86 x 117 mm Source Lamp: LED Stabilization time: Immediately Storage conditions: -20 to 65 °C Units: FNU and NTU Relative Humidity Yearly mean: < 75 %; 30 days/year: 95 %; Other days: 85 % Type of Protection: IP 67 with five years AMC
Glassware 1 ltr capacity of make Borosil, Glassco,
Jar Testers of make Electronics India, • Accepts six samples (40,000) • LED Digital Display • Digital indication of speed and timer • Digital timer from 0 to 99 minutes • Two pre-set programs • Built in illumination for easy viewing of sample • Speed range 25 to 200 rpm • Power-230V,50Hz,100 W
TDS meter of make Hach Conductivity 0.00- 1000 mS/cm; Batteries: 4 x 1.5 V alkali-manganese batteries, type AA Resolution 0.001 μS/ 0.01 μS / 0.1 μS; 1 / 0.01mS / 0.1 mS; Operational life: Up to 800 h without/ 100 h with illumination Accuracy ±0.5 % of value (Salinity); USB interface - USB B (device), data output; Dimension: 240 x 190 x 80 mm Resistivity 0.00-199.9 MΩcm; EMC - EC directive 2004/108/EC EN 61326-1 Resolution 0.001/ 0.01 / 0.1 Ω; 0.001 / 0.1 kΩ; 0.01 MΩ Accuracy ±0.5 % of value (Resistivity) 0.0 -70.0 according to the IOT table Resolution 0.1; Weight 0.8 kg; IP Class: IP 43 Accuracy ± 0.1; Operational Temp: +5 °C ... +55 °C; Admissible relative humidity: Yearly mean: < 75 % 30 days/year: 95 %, Other days: 85 %" TDS Range 1 … 1999 mg/l, 0 … 199.9 g/l (@ TDS factor 1.00) Resolution 1 ppm; 0.01 / 0.1 ppt; Accuracy ±0.5 % of value Temp Range -5.0 ... +105.0°C Resolution 0.1°C; Accuracy ± 0.1°C none, nlF, 0.000 … 10.000 %/K Reference Temperature 20 °C/25 °C Built-in Electrode Arm Yes Compensation ATC / MTC Memory 5000 data sets electrode Included, 4 cell graphite electrode, Conductivity electrode, K=0.475 "Power Requirements Input: 100/ 240 V ~ / 50-60 Hz / 270 mA Output: 9 V = / 1.1 A with five years AMC
Analytical Balance of make Radwag, Mettler Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size Ø 90 mm Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size Ø 90 mm. Standard Values Repeatability (5% Max) 0.015 mg Repeatability (Max) 0.08 mg Minimum weight (USP) 30 mg Minimum weight (U=1%, k=2) 3 mg Permissible Values Repeatability(5% Max) 0.02 mg Repeatability(Max) 0.1 mg Linearity ± 0.05 mg Stabilization time 2 seconds Adjustment Internal Verification Yes OIML Class I Display LCD (with backlight) Keypad 14 keys Protection class IP 43 Databases 5 USB-A (interchangeable) 2 USB-B 1 RS 232 2 Wi-Fi 802.11 b/g/n Power supply 12 ÷ 16 V DC Power consumption 3 W Weighing pan dimensions ø 90 mm open-work ø 85 mm standard (option) with five years AMC
Surender Kumar, Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .