Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.7 L+₹1.2 L (5.81%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹25.3 L+₹3.8 L (17.7%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹26.4 L+₹5.0 L (23.1%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹38.2 L+₹16.7 L (77.7%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
13 Oct 2021, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF CEILING FAN EXHAUST FAN WITH CONNECTED ACCESSORIES INCLUDING INTERNAL WIRING FITTING FIXTURE OF LOW RISE BUILDING AT OLD AND NEW NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_475707_1
8161/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹80,000
Yes
1 Nov 2021
16 Sept 2021
14 Oct 2021
16 Sept 2021
13 Oct 2021
30 Sept 2021
16 Sept 2021 - 6 Oct 2021
Amount
Taking down ceiling fans of 1200/1400mm sweep from site for repair complete all as specified and directed by Engr-in-Charge.
Rewinding of ceiling fan any size 1200mm size as per IS-13730 using super enameled copper wire of same guage complete and directed.
Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Canopy, bushes, bearing cap and down rod measured and paid separately.
Supply and fix Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet in provision for fixing complete all as required and as specified.
Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge.
Supply only gun metal bush suitable for any sweep fan of any make
Supply only capacitor 2.5Mfd.
Supply only ball bearing suitable for 230/300/380/450mm sweep Exhaust Fan.
Supply and Fix and replacement of 15mm dia clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins as approved by Engr-in-Charge.
Supply and fixing ceiling fan down rod of length as per suitable size and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge
Supply only ceiling fan blade (set of 3) suitable to any sweep and makes complete all as specified and as directed.
M & L for fabrication of fan hook made out of 12mm dia stainless steel rod suitable for fan hook bend to shape 'S' including 12mm dia SS fastner as required at site and as directed by Engr in Charge.
M & L for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and applying one coats of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed.
Taking out unserviceable and S&F ceiling fan 1200mm sweep, 230V, 50Hz, minimum BEE star rating and energy saving, hanging on ceiling with GI wire and connect with copper conductor multi stranded 3 core wire of size 14/0.0076.
Taking down Exhaust fan of any sweep for repairs complete all as specified and directed by Engr-in-Charge.
Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete all as specified and directed by Engr-in-Charge
M & L for rewinding of exhaust fan with super enamelled copper wire of same size/gauge, no of turns as per existing, varnishing, oiling and greasing of any make of size 230/300/380mm sweep by dismantling its parts and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover and cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate
S & F Exhaust fan blade suitable to any sweep exhaust fan and makes complete all as specified and as directed by Engr-in-charge.
M&L for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying one coat of grey enamelled paint by spray to Exhaust fan body, blades and louvers complete all as specified and as directed by Engr-in-Charge
Cutting hole in existing concrete or brick wall suitable for fixing 300mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
Taking out unserviceable and S&F Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connection as required at site with flexible copper cable all as per specified and directed.
Inspection / checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e 'S' hook, split pin, cotter pins, rubber bush etc) servicing the fan completely after removing of old grease from bearing and hanging it to its same loaction after complete assurence of any defects as specified inspecting fan for proper working, connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 all as specified and as directed by Engr-in-charge. Note (a) Complaint pertains to unserviceable Ceiling fan/Exhaust Fan/Energy Meter as given by the Engr-in-Charge shall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule (BOQ) (b) The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station No -07 and RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday.
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories and provision of PVC box for mounting of modular Switchs & Sockets as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
One bell point controlled by one push button
All as per item No 25.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F in replacement with new modular switch, 1 module, single pole one way 6Amp.
S & F in replacement with new modular switch, 1 module, single pole one way 16Amp.
S & F in replacement with new ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
S & F in replacement with new modular socket 2/3 pin, 2 module, 6A.
S & F in replacement with new Socket 6/16A, 6 pin, 2 module.
S & F in replacement with new modular bell push switch, 1 module, single pole one way 6Amp.
S & F in replacement with new modular electric bell ding dong, AC, 230V single pole.
S & F in replacement with new modular stepped type fan regulator, 2 module, single pole one way.
S & F in replacement with new lamp holder, Angle/Batten, PVC/Polycarbonate body with 7 W LED Lamp.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gang box, screwless of 8 module for mounting of modular switches and sockets including blank plate for blank module.
All as per Item No- 40.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 40.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 40.00 above but of modular PVC Gang box, 2 module.
All as per Item No- 40.00 above but of modular PVC Gang box, 1 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 2 module.
S&F modular white cover plate with frame, 1 module.
Taking down unserviceable FTL and supply and fix Slim LED intigrated batten of 20Watt 4ft coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete. Make of Light Fitting : Wipro Cat Part No D53206520 watts or BN 021C LED 20S PSU CDL GR of Philips F9 or 20WT560K of EVEREADY or SZSLAMX020 of Shakti.
All as per Item No-50.00 above but Slim LED integrated batten of 10 Watt 2ft complete. Make of Light Fitting : Wipro Cat Part No D53106520 Watts or BN021 LED 10S 6500 PSU GRS1 of Philips or 10WT560K of EVEREADY or SZSLAMX010 of Shakti.
Taking out any type of fitting bulkhead/FTL and S&F 10 watt linear LED batten, 2 feet, aluminium extruded channel, powder coated with diffuser for glare free light, inbult motion sensor prewired with 25% dimmer illuminiuos in ideal time with all accessories including two nos of PVC box of size 75x75x20mm for mounting light fittings complete in common area and staircase. Cat ref SZSLAMX010-ISS Make -Shakti or Polycab/Wipro/Havells/Bajaj.
S&F MCB DB SPN confirming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S&F MCB SPN, 32 Amp, 10 KA, 230 Volt.
S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt.
A P ENTERPRISES
NOEL ENGINEERS
S S ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .