Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.5 L+₹12,110.31 (0.59%)Rejected-AOC SIDDHARTH NAGAR | KHERI | UTTAR PRADESH | 261501 | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.6 L+₹22,535.31 (1.11%)Rejected-AOC BHAGATPUR SHIVPUR VARANASI | VARANASI | UTTAR PRADESH | 221001 | L3 | Rejected-AOC L3 |
Tender Value
₹22.9 L
EMD Value
₹41,320
Closing Date
11 Apr 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER DRAINAGE DIVISION SIDDHARTH NAGAR
Construction of Watch Tower at Majhauli Sagar in Birdpur Block In District Siddharthnagar.
2023_UPIDC_793499_1
02/EE/2022-23
Open Tender
Civil Works - Others
Item Rate
60 days
DISTRICT-SIDDHARTH NAGAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹944
₹41,320
29 Apr 2023
5 Apr 2023
11 Apr 2023
5 Apr 2023
11 Apr 2023
5 Apr 2023
Amount
Civil Work
Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 ft) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30 mt. (100) fts) from the foundation trenches.
Carted Earth filling complete in all respect.
Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm) nominal size and curing complete, including cost of form-work in foundation and floors.
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1) Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
R.C.C. work in Ground floor with cement approved coarse sand and 20 mm. guage approved stone g.it im the proportion of 1.1.53 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works strength of the concrete shall not beless than M-20 in Ground floor
R.C.C. work in First floort with cement approved coarse sand and 20 mm. guage approved stone g.it im the proportion of 1.1.53 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works strength of the concrete shall not beless than M-20 in First floor
R.C.C. work in Second floor with cement approved coarse sand and 20 mm. guage approved stone g.it im the proportion of 1.1.53 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works strength of the concrete shall not beless than M-20.
R.C.C. in Terrace floor work with cement approved coarse sand and 20 mm. guage approved stone g.it im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works strength of the concrete shall not beless than M-20.
Providing and injecting Ground floor slab (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting First floor slab (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Second floor slab (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Terrace floor slab (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Ground floor for the lighter beams i.e. having span upto 6m. (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting First floor for the lighter beams i.e. having span upto 6m. (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Second floor for the lighter beams i.e. having span upto 6m. (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Tarrace floor for the lighter beams i.e. having span upto 6m. (Using 1:1.5:3 Mix concrete ) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting R.C.C. Raft foundation and footing with approved stone ballast (Using 1:1.5:3 Mix concrete) chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution).
Providing and injecting Ground Floor RCC columns in 1:1.5:3 having strength not less than M-20 chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution).
Providing and injecting First Floor RCC columns in 1:1.5:3 having strength not less than M-20 chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per .S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Second Floor RCC columns in 1:1.5:3 having strength not less than M-20 chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
Providing and injecting Second Terrace RCC columns in 1:1.5:3 having strength not less than M-20 chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per 1.S.6313(Partil 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows (1)Treatment for masonary & foundation 5 liters per sqm (2) Back fill in immediate contact with foundation 7.5 liters'sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters/sqm (5)Treatment of soil along external perimeterof building 7.5 liters/sqm (6) Treatment of soil underapron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution).
M-150 brick work in 1:6 (one cement and six course sand of 2.25 freness modus) mortar in foundation & plinth including supply of all materials labour and T & P etc required for proper completion of the work.
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12.5 mm nominal size)
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per quare metre on damp proof course afer cleaning the surface with brushes and finally with a piece of cloth lighty soaked in kerosene oil.
Brick work in super-structure above plinth level up to foor (two level up to two storeys) including necessary cuting and moulding of bricks as required and also including honey comb brick work thickness of wal 230 mm thick to (1:6 cement & coarse sard)
Providing and laying First floor damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12.5 mm nominal size) in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
Providing and laying Terrace floor damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12.5 mm nominal size) in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
Boring with hydraulic piling rigs with power units. providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in ple cap etc. all complete (Length of pile for payment shall be measured upto the bottom of pile cap): 300 mm dia piles (Single bulb pile )
Vertical load testing of piles accordance with IS 2911 (Part IV) including installation of loading platform by kentledge method and preparation of pile head of construction of test cap and dismantling of test cap after test etc. comple as per specification & the direction of Engineer Incharge in- charge. Single pile upto 50 tonne Safe capacity . Initial test (Test load 2.5 times the safe capacity)
Vertical load testing of piles accordance with IS 2911 (Part IV) including installation of loading platform by kentledge method and preparation of pile head of construction of test cap and dismantling of test cap after test etc. comple as per specification & the direction of Engineer Incharge in- charge. Single pile upto 50 tonne Safe capacity . Initial test ( Test load 2.5 times the safe capacity ) Routine test (Test Load 1.5 times the safe capacity )
T.M.T.-FE-500 steel or iron in plan work,Ground floor such an reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape at necessary including bending for proper complation of the wors and including supply of all steel and wastage & overlapping & hooks.
T.M.T.-FE-500 steel or iron in plan work,First floor such an reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape at necessary including bending for proper complation of the wors and including supply of all steel and wastage & overlapping & hooks.
T.M.T.-FE-500 steel or iron in plan work ,Second floor such an reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape at necessary including bending for proper complation of the wors and including supply of all steel and wastage & overlapping & hooks.
T.M.T.-FE-500 steel or iron in plan work, Terrace floor such an reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape at necessary including bending for proper complation of the wors and including supply of all steel and wastage & overlapping & hooks.
15 mm cement plaster on plinth of mix : 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster on Ground floor in single coat on rough side of single orn half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (1)1 cement :6 fine sand.
12 mm cement plaster on First floor in single coat on rough side of single orn half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (1)1 cement : 6 fine sand.
12 mm cement plaster on Second floor in single coat on rough side of single orn half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (1)1 cement : 6 fine sand.
12 mm cement plaster on Terrace floor in single coat on rough side of single orn half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth and finished even and smooth (1)1 cement : 6 fine sand.
12 mm cement plaster on Ground floor in single coat on fair side of single or half brick wal for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in grith and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.
12 mm cement plaster on First floor in single coat on fair side of single or half brick wal for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in grith and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.
12 mm cement plaster on Second floor in single coat on fair side of single or half brick wal for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in grith and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.
12 mm cement plaster on Terrace floor in single coat on fair side of single or half brick wal for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in grith and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.
Engraving Iines in Ground floor the plaster of outer face wal vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour. T & P etc. required for proper completion the work.
Engraving Iines in First floor the plaster of outer face wal vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour. T & P etc. required for proper completion the work.
Engraving Iines in Second floor the plaster of outer face wal vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour. T & P etc. required for proper completion the work.
Engraving Iines in Terrace floor the plaster of outer face wal vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour. T & P etc. required for proper completion the work.
Making grooves in Ground floor 10 to 12 wide x 8mm deep in plaster of the walls or in celling vertically or horizontally as required.
Making grooves in First floor 10 to 12 wide x 8mm deep in plaster of the walls or in celling vertically or horizontally as required.
Making grooves in Second floor 10 to 12 wide x 8mm deep in plaster of the walls or in celling vertically or horizontally as required.
Making grooves in Terrace floor 10 to 12 wide x 8mm deep in plaster of the walls or in celling vertically or horizontally as required.
Supply of fixing 6mm thick china white glazed tile in flooring or dado laid with 1:3 cement & approved coarse sand mortar finished with white cement joint Ground floor
25 cement concrete flooring 1:2:4 (1 cement :2 coarse sand : 4 aggregate stone aggregate of size 12.50 mm and below) laid over base concrete and finished with floating coat of neet cement (base concrete to be paid seperately) including fixing of glass strips .
40mm thick 1:2:4 plain cament concrete floor (1 cement :2 coarse sand : 4 aggregate stone aggregate of size 12-20 mm nominal size laid in one layer neet cement
20 mm thick cement plaster in dado/skirting in 1:2 consisting of one part of cement and 2 part of approved coarse sand laid in panels, finished with 3 mm floating coat of neat cement and marble dust in ratio of 5:1 including supply of all materials labour T&P etc. required for proper completion of the work.
Providing and fixing glass strips of 3.15 mm thickness in joints of floors & skirting at the time of laying floor, flush with floor including labour tools plants etc. complete of 35 mm depth.
Providing & fixing ISI marked flush door shutters conforming IS 2202 non - decorative type core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bends and face veneers on both faces of shutters (a) 35 mm thick - single leaf.
Provindings & fixing of hold fast for chaukhats of door and windows. Mild steel or iron work of small sizes and sections such as holding down bolts hold fast tierods gratings etc (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and weiding grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing .
Provindings & fixing of door / windows grill.. Mild steel or iron work of small sizes and sections such as holding down bolts hold fast tierods gratings etc (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and weiding grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing .
Provindings & fixing Z- section steel windows. Mild steel or iron work of small sizes and sections such as holding down bolts hold fast tierods gratings etc (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and weiding grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing .
Fixing of Door, chaukhats in position.
Fixing of Dwindows chaukhats in position.
Fixing of ventilators chaukhats in position.
Distempering (Two coat) with oil bound distemper approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger ,J&N, Shalmar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign maters & also including preparing the surface even with plaster of paris or approved synthetic matarial & sand papered smooth including cost of all materials (Inner walls)
Finishing was with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqn ove and including priming coat of exterior primer applied @ 2.20 kg/10sqm )
Distempering (Two coat ) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials (Celling )
Providing and applying white cement based putty of average thicknees 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing & laying brick bat Coba 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of cuba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all materal labour T & P etc complete for proper completion of work.
Painting or varnishing work in small areas or new wood work with one to one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour ,Tools & plants etc. required for proper completion of the work, Paint to be used should fonfirm the ISI no. 103.1950 (M.S. works)
Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one cost of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc required for proper completion of the work. Paint to be used should fonfirm the ISI no 103- 1950 (Wooden works)
Fixing panes of glass with and including Atul or equivalent ISI mark quality putty and brads and spring including supply of all materials, labour. T & P etc. required for proper completion the work 4.0 mm thick glass panes.
Providing and fixing ISI marked oxidised MS sliding door bolts with nuts and screws etc. complete: 250x16 mm
Providing and foxing ISI marked oxidised M.S. tower bolt black finish (Barrel type) with necessary screws etc.complete: 250x10 mm
Providing and foong ISI marked oxidised M.S. handles conforming to IS :4992 with necessary screws etc.complete: 125 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Construction of drain along with apron 150x150mm
Electric Work
Wiring points for light with 1 sqmm.FRLSH PVC Insulated single core aluminium condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with 1.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc complete in all respects.
Wiring points for light with 1 sqmm.FRLSH PVC Insulated single core aluminium condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with 1.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc complete in all respects. for fan and light duty exhaust fan
Wiring points for light with 1 sqmm.FRLSH PVC Insulated single core aluminium condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with 1.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc complete in all respects. 5 Amp plug point
Supply and wiring of submain 2 number 4 sqmm FRISH PVC insulated 1100 v grade multistranded single core copper conductor cable in heavy duty (2 mm thick) 20mm dia PVC condit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
Supply fixing and concealing of 20 mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid plastering with cement sand mortar finished to level with matching colour inducing cost of material labour and T & P etc required for proper completion of work ( for Telephone point)
Erection and testing of celling fan and regulator for room height upto 3.5mts, including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects
Erection and testing exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
S/F of hexagonal fan box with hexagonal side of approx 80 mm in length fabricated from 16SWGMS sheet incorporating 10mm dia, MS. round barduly bent for supporting fan hanger duly painted withred oxide and screwing arrangement with wiring conduit laid in the RCC roof before concreting along with supply of all materiais, labour T & P etc, for proper completion of work.
Supply fixing of electronic fan regulator 125-280 v. ISI marked, on the exiting switch board including making connection, required material, labour T&P etc for proper completion of work to the satisfaction of Engineer in charge of work
Supply & faxing of single wall light bracket made of brass on matching polished MOFEG board brass including connection etc. as required CAT AAA
Supply and Phong of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. 1x22 W CAT-AAA
Supply and fixing of flush/surface mounting distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. 12 Way SPN CAT B
Supply and fixing of 240 volts L series miniature drouit breaker 6 Amp. To 32 Amp (10 xK A) in existing MCB, DB complete with connections as required, 6-32 amps.
Supply fixing and making connection of following MCBS complete in all respect as per directionand satisfaction of engineer-in -charge 63 AMP. DP MCB
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
Supply and fixing Single Pole MCBS Blanking Plate complete in all respect.
Supply and burying of 600mm x 600 mmx6mm G.I plate, vertically for earthing with its top atleast 3 mts below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No 8to10SWG GI wire in 15mm diaG.I pipe upto switch board (from apron to switch board the cost of GI pipe and G.L. wire will be extra) 30cm. square C1. frame with hinged cover, masonary housing, alternate layers/of charcoal coke and salt at least 150mm thick alround etc. complete in all respects.
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects
Supply and fixing of one number & SWG G.I wire in 15mm dia. GI pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mm x 75 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding moduler plate etc as required. Telephone socket outlet.
Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC Insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair.
Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceiling fan with regulater standar down rod, blades including connection etc. complete as required.
Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required .300mm sweep.
Plumbing works
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap 10 litre low level white PVC flushing cistern with manualy controlled device (handle lever) conforming to IS.7231 Parryware Hindware Seabird Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa patern W.C. pan of size 580x440 mm with integral type foot rests.
Providing &fixing white vitreous china wash basin with CI brackets painted white 15 mm CP. brass pillar taps C.P.brass chain with rubber plug 32 mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. (a) White vitreous China Flat back wash Basin size 550x400mm with single 15 mm C.P. brass pillar tap.
Providing and fixing P.V.C. waste pipe for sink or basin including PVC waste fittings complete. Semi rigid pipe 32 mm dia
Providing and fixing 600x450mm bevelled edge mirror of superiorr glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.
Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (a) 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of acproved quality conforming to IS:8931 15 mm nominal bore
Providing & Fixing soil and vent pipes. 100 mm dia centrifugally cast iron S&S pipe
Providing & Fixing soil and vent pipes. 75 mm dia centrifugally cast iron S&S pipe
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes &fitting of diameters. 100 mm
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes &fitting of diameters. 75 mm
Providing and laying cement concrete 1:5:10(1 cement :5 coarse sand :10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring/ ground) For 75 to 110 mm dia
Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 100mm inlet & 75mm outlet.
Providing & fixing cast iron coller. 100 mm dia.
Providing & fixing cast iron coller. 75 mm dia.
Providing and fixing plain cast iron S & S sanitary bend. 100 mm
Providing and fixing plain cast iron S & S sanitary bend. 75 mm
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100 mm
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 75 mm
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS.13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.110 mm Bend.
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS.13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Shoe.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc. 110 mmcomplete.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testang of joints complete as per direction Engineer in Charge. Concealed work including cutting chases and making good the wall etc. 20mm dia nominal outer dia pipes.
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work) Exposed on wall 25mm dia nominal bore.
Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work) Exposed on wall 32 mm dia nominal bore
Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work 25mm dia nominal bors .
Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work 32 mm dia nominal bors .
Providing and fixing GI Union in Gl pipes including cutting and threading the pipe and making long screws etc. complete (new work) 25mm dia nominal bors.
Providing and fixing GI Union in Gl pipes including cutting and threading the pipe and making long screws etc. complete (new work) 32 mm dia nominal bors.
Providing and foung gun metal gate valve with wheel approved quality. 25 mm dia nominal bors.
Providing and foung gun metal gate valve with wheel approved quality. 32 mm dia nominal bors.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license] . Capcity in Per Liters.
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc, and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300 mm.
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc.complete. 100 mm dia SW pipe
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100 mm dia SW pipe
Providing and laying Non pressure NP 2 class (light duay) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement :2 fine sand) including testing of joints etc. complete . 1962 150 mm dia. RCC Pipes
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm dia RCC Pipes
Providing and faxing square-mouth SW. gully trap grade A complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS: 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat to neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm rminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including Cl cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 For Sewer Line.
Extra for depth for manholes: Size 90x80cm with FPS bricks (class 1).
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
Extra for providing & fixing 125 mm dia grating in place of C.I. grating over floor traps
Providing & fixing Single Towel Rail 600 mm Long as per aproved brand
Supplying & fixing of Soap Dispenser with glass bottle as per aproved brand
Septic Tank works
Excavation in Foundation in ordinary soil (Loam clay, or sand) Including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (From 0.00 mt to 1.50 mt)
Excavation in Foundation in ordinary soil (Loam clay, or sand) Including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (From 1.50 mt to 3.00 mt)
Excavation in Foundation in ordinary soil (Loam clay, or sand) Including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (From 3.00 mt to 4.50 mt.)
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 [1 cement :1.5 coarse sand :3 stone aggregate] in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. As in item no. 3 above but for slabs.
M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fo 500).
15 mm cement plaster on rough side of single or half brick wall of mix. (1) 1 cement: 4 Coarse sand.
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
Providing and fixing soil, waste and vent pipes: 75mm diameter Sand cast iron S&S pipe as per IS: 1729
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) as per standard design: (With 20x20mm square bar)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Boring works
Boring/drilling bore well of required dia for casing /strainer pipe, by suitable method prescribed in IS: 2800 (part 1) including collecting samples from different strata, preparing and submitting strata chart bore log. Including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 50 metre depth below ground level 150 mm dia upto 90 metre depth below ground level
Boring/drilling bore well of required dia for casing /strainer pipe, by suitable method prescribed in IS: 2800 (part 1) including collecting samples from different strata, preparing and submitting strata chart bore log. Including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 50 metre depth below ground level 150mm dia Upto Beyond 50 metre & upto 150 metre depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. aII complete, for all depths, as per direction of Engineer-in-charge (1) 110 mm nominal size dia
Supplying assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. (1) 110 mm nominal size dia
Supplying filling. spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit). with required capacity air compressor, running the compressor for required time til well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, Vc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 110 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing housing pipe of tubewell as per IS: 2800 (part 1). including necessary bolts & nuts of required size complete. 110 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part 1) 110 mm dia.
PUMPING SET KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. [1.5 H.P.)
Supply and fixing of nylon jali around the slotted pipescomplete as required. Up to 10 meter
Supply and fixing of finolex of copper cable ISI marked submersible cable of size 4 sq mm
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore
Step works
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the space between the building and sides of foundation benches or into the plinth and removal and disposal of surplus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches including all T & P phowarah and basket etc complete.
Providing and laying cement concrete 1:4:8 (1) cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P etc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M 20) in footing excluding supply of reinforcement and its binding but B.W.G.G.L binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item M-20
R.C.C. work with cement approved coarse sand and 2 cm. (3/4") gauge approved stone ballast in the proportion of 1:1.5:3 (M 20) in columns excluding supply of reinforcement and its binding but B.W.G.G.L binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item M-20
M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, and T & P etc.required for proper completion of the work.
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
M/S RAMASHANKAR CONTRACTOR
M/S SINGH TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .