Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.9 L+₹56,270 (3.07%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹20.5 L+₹2.1 L (11.6%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹20.5 L+₹2.2 L (11.9%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹20.6 L+₹2.2 L (12.1%)Rejected-AOC LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L5 | Rejected-AOC Other than L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
15 Jan 2021, 6:00 pmClosed
Shri TKM Rambhal, EE
GE (West) Mathura Pin-281001
Repair to tiles, chequared tiles, roof sheet, glass panes, false ceiling and connected internal wiring under GE(W) Mathura
2020_MES_405911_1
8300/985/E8
Open Tender
Civil Works
Item Rate
180 days
Mathura Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹50,000
Yes
21 Jan 2021
23 Dec 2020
16 Jan 2021
23 Dec 2020
15 Jan 2021
3 Jan 2021
Amount
Dismantling of AC (corrugated or semi corrugated etc) sheets in roof covering complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel ridges suitable for corrugated steel sheet 0.5mm thick of red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts and washer in roofs, walls etc complete all as specified and directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts and washer in roofs, walls etc but except sheet complete all as specified and directed.
S&F 6mm thick asbestos cement two pices adjustable plain wing ridge complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets and frame complete all as specified and directed.
M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, size of grid 605mm x 605mm including providing and fixing designer decorative Gypsum board 4mm thick complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' old size brick straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
All as per item No 10.00 (here-in-before) but except bricks.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM in (1:4) finished fair and even external surface complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on brick or concrete surface other than fair faces of brick complete all as specified and directed.
M&L for rendering 5mm thick in CM (1:4) on fair finished faces of ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a one coat of alkali resistance primer complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a one coat of chalk whitening on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section in framed work, in any position complete all as specified and directed.
S&F steel work in tubular trusses including columns, special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade St-240 complete all as specified and directed.
M&L for applying two coats of synthetic enameled paint over a coat of red oxide primer on new steel surfaces exc. 10 cm girth and width including preparation of new steel surfaces complete all as specified and directed.
Dismantiling floor, hearth or wall tiling including cement motar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premishes complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 8 to 9 mm thick exceeding 0.11 sqm but not exceeding 0.18 sqm (Square/rectangular) in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
All as per item No 23.00 (here-in-before) but over 10mm thick rendering in CM (1:3) as in skirting/dado.
M&L for joint free Non skid coloured ceramic tiles 8 to 9 mm thick exceeding 0.18 sqm but not exceeding 0.38 sqm (Square/rectangular) in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
All as per item No 25.00 (here-in-before) but over 10mm thick rendering in CM (1:3) as in skirting/dado.
M&L for glazed coloured ceramic tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) for skirting / dado finishes complete all as specified and as directed.
Demolition of cement concrete ( unreinforced ) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and as directed
M&L for cement concrete type B0, (1:2:4) (using 12.5mm graded stone aggregate) as in benching/coping and the like including weathering slightly round or chamfered angles and throating complete all as specified and directed.
Dismantling structural steel work of any description and in any position complete all as specified and directed.
S&F mild steel flat iron as in hold fasts, wind ties etc and similar small work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for pre-polished ultra designer chequered tiles (any colour) of size 30cm x 30cm x 25mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed.
M&L for providing 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in base of interlocking tiles/chequered tiles complete all as specified and directed.
Taking down surface / concealed copper / aluminium point wiring (light,bell,fan,socket or power) complete, including fixtures and fittings such as switches,ceiling roses,lamp holders,pendants,sockets, regulators,light fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete.
M&L for point wiring for one light point controlled by one switch with PVC insulated, unsheathed 1.5 sqmm FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC concealed conduit medium grade not less than 20 mm dia ISI marked ivory colour with and including all conduit fittings and fixing accessories including not less than 1.60mm thick sunken anodised pressed steel terminal boxes/modular boxes suitable for fixing of modular face plates, 3.0 mm thick hylam sheet cover/modular plate cover for mounting switches, sockets, fan regulators etc incuding 1.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete.
S&F switch piano flush button single pole, one way 5 Amp 240 Volt complete all as specified and directed.
S&F 36 W LED edge-lit luminaire suitable for armstrong/grid ceiling complete with separate electronic driver 6000K of 2'x2' LED panel for recessed dust-free installation with high brightness LEDs for glare-free homogenous illumination with all connected accessories complete all as specified and directed.
B S ENTERPRISES
M/S ANIL KUMAR AGRAWAL
M/s Kartar Singh Construction Co.
ISHWAR ENTERPRISES
JWALA ELECTRIC CONTRACTORS
M/s Hoti Lal Contractor
M/S SHRI RAM INFRASTRUCTURE
SHRI RADHAYSHYAM JHA
Jain construction co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .