| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.9 L+₹2.0 L (4.86%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹45.5 L+₹4.7 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹47.5 L+₹6.6 L (16.2%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
22 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt PIN-144005
Please refer tender documents
2023_MES_634439_1
8323/64/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class D Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
AGE (I) Suranussi
₹85,000
Yes
23 Mar 2024
26 Dec 2023
29 Jan 2024
26 Dec 2023
22 Jan 2024
10 Jan 2024
Amount
Demolition of brick work built in cement mortar including all quoins arches, pillars etc but including ashalr facing dressed stone work and precast concrete articles complete all as specified and as directed by engineer-in-charge.
Demolition of cement conc in ground floor and pavings not exceeding 15 cm thick above or below ground level complete all as specified and as directed by Engineer-in-charge.
Taking down chowkats or frames with Shutters ( without taking off the shutter from the frame ) of area n.exc 1.50 Sqm each and removing from site complete all as specified and as directed by engineer-in-charge.
Taking down chowkats or frames with Shutters ( without taking off the shutter from the frame ) of area exc 1.50 Sqm but n.exc 4.00 Sqm & removing from site complete all as specified and as directed by engineer-in-charge.
Taking down shutters of any description exceeding 1sqm each and not exceeding 2.00 sqm each complete all as specified and as directed by engineer-in-charge.
M&L brick work , with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exc 6mtr mean radius, using old size bricks complete all as specified and as directed by engineer-in-charge.
Ditto all as per item No 6 above but except bricks.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc incl raking out joints hacking for keys srubbing down with water etc complete all as specified and as directed
M&L 15mm thick cement plastering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&L 15 mm thick cement plastering in cement mortar (1:4) of brick work or concrete surfaces with using water proofing compound finished even & smooth without using extra cement complete all as specified and as directed by engineer-in-charge.
M&l for 5 mm th rendering in cement mortar in 1:3 on ceiling complete all as specified and as directed
Dismantling of asbestos cement sheets (Corrugated, semi corrugated etc) in roof coverings complete all as specified and as directed by engineer-in-charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ,fixed with J-type hook in any location complete all as specified and as directed by engineer-in-charge.
S&F Pre- painted galvalume aluminum zinc coating GI based plain sheet ,sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ,fixed with J-type hook complete all as specified and as directed by engineer-in-charge.
Dismantling wall and Ceiling boards any thickness, including cover fillets complete all as specified and as directed by engineer-in-charge.
M&L for 12mm th perforated particle board/tiles for insulation and accoustic purpose 60X60CM in size fixed in frame work /gridcomplete all as specified and as directed by engineer-in-charge.
M&L 605mmX605mmsize anodised Aluminium snap grid frame work for false ceiling with aluminium angle 25X25X1.5mm th and Tee 25X35mmX1.5mm th and using 2mm GI wire adjustable as suspender in required length complete all as specified and as directed by engineer-in-charge.
S & F 1 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and cup board with all locking arrangement similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
S & F reflective HIP cautionary circular sign board of size 600 mm made of ACP sheet 3 mm thick supported over 25x25x3 mm MS angle iron frame powder coated with hold fast.front side of the sign board fully reflective with high intensity reflective sheet base letter ,sign and border duty computer cut.sign board supported over single leg of 47 mm MS square pipe of 3 mtr long duly painted black and white incl exc in post holes each n.exc 0.50 cum and removing surplus soil n .exc 50m and making good surface in loose/soft soil filling with cement concrete type B1 1:2:4 (40 mm graded agg ) as in foundation filling and mass concrete complete all as specified and as directed
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering to Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165) complete all as specified and as directed by engineer-in-charge.
Taking down shutters of any description exceeding 2 sqm each complete all as specified and as directed by engineer-in-charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing/gate made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
Taking down PVC wall panelling and similar work complete all as specified and as directed by engineer-in-charge.
S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed by engineer-in-charge.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. complete all as specified and as directed by engineer-in-charge.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed by engineer-in-charge.
M&L preparing surfaces of new walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by engineer-in-charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M&L preparing surfaces new of walls and applying two coats of cement base paint over a coat of primer complete all as specified incl preparation of surfaces.
M&L for three coats of white wash on newly plastered surface of ceiling incl preparation of surface complete all as specified
M&L for two coats of synthetic enamel paint on new steel surface over 10cm width or girth over a coat red oxide primer complete all as specified and as directed by engineer-in-charge.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 as in plinth protection with using 40mm graded stone aggregateincl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ration 1:2 by weight etc complete all as specified and as directed by engineer-in-charge.
M&L for 40mm th PCC 1:2:4 type B1 (using 20mm graded aggregate) as in flooring incl finishing the surface even and smooth with using extra ement complete all as specified and as directed by engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rmoving servicable tiles to store and rubbish off the premises complete all as specified and as directed by engineer-in-charge.
M&L for Acid resistant/proof tiles 15 mm thick vitreous ceramic, unglazed, set, jointed and pointed in approved chemical resistant mortar, resin type, to match the shade of existing floors complete all as specified and directed by Engineer-in Charge
M&L for Acid resistant/proof tiles 10 mm thick vitreous ceramic, unglazed, set, jointed and pointed in approved chemical /chemical resistant mortar, resin type,to match the shade of existing walls complete all as specified and directed by Engineer-in Charge
M&L Non-skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over 15 mm th screed or bedding layer in CM 1:6 complete all as specified and directed by Engineer-in Charge.
M & L for 15-20 mm thick lakeland stone on wall /pillars/elevation as approved size ,pattern and shade, design (design approved by Engineer -in charge) polished, set and jointed in cement and stone dust mortar 1:3 and pointed in cement mixed with approved pigment to match complete all as specified and directed by Engineer-in Charge.
M&L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone over 15 m thk screed or bedding layer in CM 1:6 including grinding and polishing all as specified and directed by Engineer-in Charge complete
Supply & fixed sliding/opening anodised powder coated aluminium window (minimum thickness of powder coating 50 micron) shutters including frame and made out of hollow extruded alumimum sections as mentioned below. Each window having triple channel with triple shutters (two Nos glass and one No wire gauge shutter ) including 03 Nos D type handles, 02 Nos aluminium tower bolts 300 mm size, 01 Nos door closer hydraully regulated. Shutter to be partly glazed with 5 mm thick, plain or tinted glass.Chowkat / frame 101.60 x 44.45 x 1.60 mm thick Shutter top and bottom rail : 114.30 x 44.45 x 1.55 mm thick, complete all as specified and directed by engr-in-charge.
Supply & fixed sliding/opening anodised aluminum Powder coated aluminium door (minimum thickness of powder coating 50 micron) and partitions (Fixed portions)work for doors, (Fixed portions) anodised aluminum door shutters including frame and locking arrangement and made out of hollow extruded alumimum sections as mentioned below. Each door having 02 Nos D type handles,01 door stopper 02 Nos aluminium tower bolts 300 mm size, 01 Nos door closer hydraully regulated. Shutter to be partly glazed with 5mm thick, plain or tinted glass and partly paneled with 12 mm thick prelaminated particle board fixed with glazing clips, rubber beading / gasket, anodized aluminum beading, screws including bothside openable in door bottom hydraulic double action machine machine complete all as per specified and directed. Chowkat / frame 101.60 x 44.45 x 1.60 mm thick Shutter top and bottom rail : 114.30 x 44.45 x 1.55 mm thick, Shutter middle rail 83.50 x 44.45 x 1.55mm, Shutter verticle style : 85 x 44.45 x 1.55 mm thick.complete all as specified and directed by engr-in-charge.
Supply & fixed factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat /Frame size 65x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
Supply & fixed factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and including locking arranmgement and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
S & F Neoprene/ EPDM rubber gasket all as specified and as directed by engineer-in-charge.
S & F Steel ventilator with top hung shutter including hinges, steel peg stay, glass and wire gauge complete all as specified and directed by engr-in-charge (Get to be ascertained by BOO to be convened by GE).
Dismantling Matting, single or double any type including, bamboo framing or bamboo supports, cover fillets, if any
M & L 3.2/3.3 mm thick linoleum, plain coloured, laid dry in floors including stretching, cutting and fitting with approved adhesive/chemical complete all as specified and directed by engr-in-charge.
M & L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete.complete all as specified and as directed by engineer-in-charge.
Form work to soffits of suspended slab such as roof slab/Kitchen slab n exc 200mm thick (horizontal/sloping/vertical) with fair finished surface complete all as specified
M & L TMT bars 6mm to 8mm dia. cut to length bent to shape required including cranking, bending and binding with and including ms wire (annealed) n. less than 0.9mm dia or securing with clips complete all as specified
Demolition of cement concrete is reinforced of any description and in any position not otherwise specifically provided for as specified and directed by Engineer - in - Charge .
M&L Reinforced cement concrete (nominal mix) Type B-0 1:2:4 (12.5mm graded aggregate) in slabs supported on walls, beams, columns deck slabs and in shelves, the like all as specified and directed by Engineer - in - Charge .
Dismantling boarding, any description, fixed in any position with fixed with screws
M&L for Providing precast cement concrete louvres and jallies (design approved by engineer -in charge), 25 mm thick (measured solid) set in cement mortar 1:4, Type B0 1:2:4 (12.5mm graded aggregate) including all mould- ings and applying two coats of exterior emulsion paint over a coat of alkali primer over it incl the preparation of surface. complete all as specified and directed by engr-in-charge.
M&L for Providing Precast GFRC (Glass fibre reinforced concrete ) louvres screens in approved size ,pattern and shade, design (design approved by Engineer -in charge) and thickness of 50 mm on frame and design element in 30mm thick have weight approx between 3.5-4 kg /sqft .The scren should be made from 53 grade white portland cement manufactured by N.E.G japan or equivalent ,super plasticizers manufactures by BASF or equivalent ,polymers manufactured by BASF or equivalent and U.V. resistant synthetic inorganic pigments should be used for pigmentation manufactured by BATFERROX or equivalent .The material casting should take place in frp molds .The fixing of screebs should be dry fixing i.e. to be done with M.S galvanised clamps ,fixtures and fasteners of Hilti/fischer etccomplete all as specified and directed by engr-in-charge.
Dismantling brick tile or terracing tile single layer on roof complete all as specified and as directed by engineer-in-charge.
Demolition of mud in roofs any thickness including plastering and leeping (weather full thickness removed or part there of) complete all as specified and as directed by engineer-in-charge.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by engineer-in-charge.
M&L for 75mm average consolidated thickness P.C.C 1:3:6 type C2 with using 20mm graded stone aggregate as in padding on flat roofs etc all as specified and directed.
Supply only Integral water proofing compound complete all as specified and as directed by engineer-in-charge.
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm over a coat of primer including cleaning surfaces complete all as specified and as directed by engineer-in-charge.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application complete all as specified and as directed by engineer-in-charge.
M&L for 40mm thick brick tiles laid on cement mortar bed ( 1:3) with WPC and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement and pointed in CM (1:3) complete all as specified and as directed by engineer-in-charge.
All as per item No 63 above but except brick tiles
M&L Providing, cement concrete type B2 (1:2:4) (using 20 mm aggregate), as in roof kerbs or mud stops, rounded or chamfered on edges parapets copings, bed plates, etc complete all as specified and as directed by engineer-in-charge.
Cutting grooves of size 75mm wide and 65mm deep in brick parapet wall for inserting APP membrane and making good the disturbed portion in CM (1:3) complete all as specified and as directed by engineer-in-charge.
SUNRISE CONSTRUCTION COMPANY
SONA BUILDERS
AAY KAY Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .