Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.1 L+₹4.1 L (29.5%)Rejected-AOC KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.0 L+₹7.0 L (49.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.3 L+₹8.3 L (59.1%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.3 L+₹9.2 L (66.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
7 Aug 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
REPAIR OR REPLACEMENT OF UG CABLES, ACSR CONDUCTOR, POLES, LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT SUNJUWAN UNDER GE JAMMU
2020_MES_359475_1
GEJC-29/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of GE Jammu
Class E category b i
8 documents required · 8 mandatory
₹500
GE Jammu
₹46,000
Yes
28 Oct 2020
10 Jul 2020
10 Aug 2020
10 Jul 2020
7 Aug 2020
24 Jul 2020
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 deep for foundations of poles/stays/cable etc. and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches exc 1.5 m wide and n.exc 3.0 deep for foundations of poles/stays/cable etc. and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in earth including spreading levelling watering and well ramming in layers each not exceeding 25 cm thick each layer, complete all as specified and as directed.
Removing of surplus soil to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and as directed by Engr-in-Charge.
M & L for sand cushioning with a layer of fine sand (sand for plastering) 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and as directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable , adjacent/abutting each other complete all as specified and as directed by Engineer-in-charge in trenches over the cable for protection.
Relaying of serviceable bricks breath wise in trenches for UG cable protection complete all as specified and as directed.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape and including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof as directed by the Engineer-in-Charge. Note:- Earth work for taking out of poles shall be measured and paid separately under relevant item of this Schedule.
Dismantling cross arms of MS channel or angle sections etc., and keeping serviceable materials in safe custody for re-use and/or unserviceable materials removing from the Site(s), complete all as specified and directed.
Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s), complete all as specified and as directed. Notes:- a) Unserviceable Stay assembly shall be taken off/dismantled at Ground Level and making good disturbed ground surface. b) Earthwork for demolition of cement concrete shall be measured and paid separately under relevant Items of this Schedule.
Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re-use and unserviceable materials removing from the Site(s), complete all as specified and as directed.
Dismantling earth wire of any size/dia or aluminium conductor, guarding cradle or disturbed span and keeping serviceable materials in safe custody for re-use and removing unserviceable materials from the Site(s) complete all as specified and as directed.
Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and/or unserviceable materials removing from the Site(s), complete all as specified and as directed.
Supplying, erecting and fixing Pre-stressed concrete poles 9 mtr long of cross section 102mmx172mm at top and 102mmx279mm at bottom Class 10 compluing with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint in black and white strips each 30 cm wide each up to 1.5mtr high from coping over a coat of primer including numbering of poles complete all as specified and as directed.
M&L for PCC(1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of electric poles,struts,PCC blocks etc including necessary form work complete all as specified and as directed.
M&L for PCC(1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of assembly,bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specifieds,struts,PCC blocks etc including necessary form work complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections, including nuts, bots, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat (red oxide, zine chrome primer), one under coat and one finishing coat of aluminium paint including preparation of surfaces complete as specified and directed.
Fixing only serviceable cross arm, MS Channel, angle section obtained from item No 9 here-in-before as ordered and inclusive of one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed.
S&F stay assembly comprising of stay bow 40cm long,16mm dia , complete with accessories as shown in electrical Plate No-1 of SSR Part-1 with and including 16mm dia stay rod 180cm long with threaded ends,GI nuts,check nuts,bolts,washers 2 thimbles MS clamp made out of 40x6mm flat Iron includig nuts,bolts and washers,230mmx230mmx6mm thick stay plate and also exposed surfaces shall be given two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F loop type insulators vitreous porcelain white / brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete as specified and directed.
S&F galvanized stay strand of size 7/4.00 mm complete all as specified and as directed.
M&L aluminium conductor steel reinforced (ACSR) of sizes on LT poles including straining, binding with insulators with aluminium binding wire with insulator as in OH conductor, providing PVC sleeves for jumpers complete all specified and directed.
Fixing only by re-straining, tightening of ACSR conductors of any size/type on HT/LT poles including necessary new aluminium binding wire for fixing with insulator/PVC sleeves for jumper etc as required complete all as specified and as directed. Note : Serviceable ACSR conductors shall be obtained from item No. 11 here-in-before.
S&F PVC fibre separator for LT line 1100 volt OH conductor 3/4 wire system for maintaining horizontal spacing of conductor complete with nut & bolt minimum two nos in a span complete as specified and directed.
M&L galvanised steel continuous earth wire 3.15 mm or 4 mm dia and fabricating cradles,hexagonal/rectangular complete as specified and directed.
Fixing only serviceable GI wire 3.15 mm or 4 mm dia martial obtained from item No 12 here-in-before complete all as specified and directed.
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete as specified and directed.
Fixing only serviceable pin type porcelain, vitreous, (white/brown or green) insulator for 1100 volts grade of any type obtained from item No 13.00 here-in-before.
S&F shackle type, porcelain, vitreous white, brown or green insulator including galvanised mild steel straps of size 31 x 3 mm, 12 mm dia insulator bolts, nuts and washers for working pressure 1100 volts of size 75 mm height, 90 mm dia complete as specified and directed.
Fixing only serviceable shackle type porcelain, vitreous (white / brown or green) insulator of any size and shape for 1100 Volts grade obtained from item No 13.00 here-in-before.
Preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 11.00 metre length including MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 2.4 mtr height from the top of caping/ bottom of pole as per site condition and numbering of poles complete all as specified and as directed by Engr-in-charge.
Note: Zebra colour will be applied by synthetic enamel paint of White/Black (or Green) colour as approved in alternate layer of 30 cm height of each layer.
Labour for Cutting of tree branches 2 mtr above the conductor which are touching to the LT Over Head Lines in vertically & horizontally conductor and poles etc, complete clear in a standard Span in between two poles as per SSR Part-I, 19.59 and removing cutting material not exc 50 mtr and depositing where directed at a distance level not exc 3 mtr from starting point, minimum 04 Nos of Mazdoor-man with ropes/cutting tools complete will be engaged for a standard one span at a forest/high gradient/any type of surfaces, follows safety measures as per IE Rules, all as specified and as directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular poles of any long type 410 SP-55 and applying one coat of synthetic enamel paint up to 1.2 mtr height as per exising pattern above the P.C.C coping and two coat of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) incl cross arms and channel, angle fitted on the pole incl wiriting pole numbers and cutting vegetation growth all arond and on the poles up to 1 mtr radius complete all as specified and directed.
Taking out old / unserviceable under ground LT cables and connections including pipes, bricks or precast concrete cable cover etc of any from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site all as specified and directed.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 300 sq mm 3 1/2 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and pannels complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 185 sq mm 3 1/2 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 95 sq mm 3 1/2 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 50 sq mm 3 1/2 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 35 sq mm 3.5 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 70 sqmm 3.5 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 25 sq mm 4 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 16 sq mm 2 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
All as per Ser Item No 36.00 above but of size 10 sq mm 2 core. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Supply and laying mild steel galvanised iron pipe light grade 80mm bore(for passing of cable/laid in trenches fixed to pole/ walls/laid under floors/roads) complete with and including fittings as required all as specified and as directed.
All as per Item No 45.00 above here-in-before but 50mm bore all as specified and as directed.
Labour for Horizontal Boring Road/Foot Path, not exc. 20.00 METRE in Length, complete all as specified and as directed.
S&F danger notice plate for LT poles of size 20cmx15 cm of 1.6mm thick mild steel sheet vitreous enamelled white with letters,figure and conventional skull and bones "DANGER" in Hindi & English etc. in single red colour and fixed with MS clamps made out of 25mmx3mm MS flat iron bolts,nuts complete including two coat of red oxide primer all as specified and as directed.
Anti Climbing device fabricated out of MS flat iron 40x 6 mm in two parts with 20 Nos spikes 230mm long and 12mm dia,size and shapes to suit the cross section of the pole including nuts,bolts,washers and welding etc including two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3 1/2 or 4 core XPLE armoured aluminium conductor cable of size 25 to 50 sq mm all as specified and as directed.
All as per item No. 50.00 here-in-before but for cable of size 70 to 95 sq mm all as specified and as directed.
M&L for road cutting, PCC hard standing with width 0.4 & depth 0.6 mtr including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface all as specified and as directed.
Supply,install, commission and testing cubical type LT panel board,outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :-
MCCB 4 pole 630 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu. Make Havells Cat No IHLLNFCF0630# -(incoming)= 01 Nos
MCCB 3 Pole 250 A breaking capacity 50 KA at 415 Volt AC ,50 Hz ,L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu. Make Havells Cat No IHLLNFCT0250# (incoming)= 03 Nos
LED indicating lamp (RYB)
Necessary foundation in PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 Job Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
M&L for removing existing pannel and refixing at said location with repacement of below mentioned items including painting with two coat of synthetic enamel paint and connecting the MCCBs bus bars with suitable size of PVC insulated copper cable,copper Lugs,cable gland,Bolts,Nuts and washers,Phase terminals etc. complete all as specified and directed by Engr-in-charge.
MCCB 4 pole 630 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0630# -(incoming)= 01 Nos
MCCB 3 Pole 250 A breaking capacity 50 KA at 415 Volt AC ,50 Hz ,L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCT0250# (incomming)= 03 Nos
LED indicating lamp (RYB)
Copper wound CT 100/5-03 Nos
Necessary foundation in PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 Job Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation
M&L for removing existing panel and for refixing at said location with repacement of below mentioned items including connecting the MCCBs bus bars with suitable size of PVC insulated copper cable,copper Lugs,cable gland,Bolts,Nuts and washers,Phase terminals etc. complete as specified and directed by Engr-in-charge. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
MCCB 4 pole 630 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0630#
MCCB 4 pole 250 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0250#
MCCB 4 pole 400 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0400#
MCCB 3 pole 250 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCT0250#
MCCB 3 pole 200 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0400#
MCCB 3 pole 160 A breaking capacity 36 KA at 415 Volt AC ,50 Hz (HID Series type Adjustable thermal and fixed Magnetic setting,lcs=100% of lcu Make Havells Cat No IHA13EBT0160#
S&F in replacement unsv indicators LED set of three pieces as per existing size and sample completed all as specified and as directed by Engr-in-Charge.
S&F Copper wound CT 100/5 - 03 Nos complete all as specified and directed by Engr-in-charge.
S&F in replacement Ampere meter digital type 0-200/ 0 to 400, 0 to 600 96 sqmm square type flush panel mounted completed all as directed by Engr-in-Charge.
S&F Volt meter digital type 0-500 Volt 96 sqmm square type flush panel mounted complete all as directed by Engr-in-Charge.
M&L for replacment of old burnt out aluminium bus bar and connected link bar with proper colour coading with insulation tape of current rating 630/400 Amps incl replacement of old rusted nut&bolts, washers complete all as directed by Engr-in-Charge.
Supply,install, commission and testing cubical type LT panel board,outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :-
MCCB 4 pole 250 A breaking capacity 50 KA at 415 Volt AC ,50 Hz (L frame type Adjustable thermal and Adjustable Magnetic setting,lcs=75% of lcu Make Havells Cat No IHLLNFCF0250#
MCB TP 63 Amps breaking capacity 10 KA at 240 Volt AC ,50 Hz (outgoing)= 10 Nos
LED indicating lamp (RYB)
Copper wound CT 100/5-03 Nos
Necessary foundation in PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 Job
PVC connectors for TP as required. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
Supply,install, commission and testing cubical type LT panel board,outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :-
MCCB 100 Amps 4 pole, breaking capacity 36 KA at 415 Volt AC ,50 Hz (HID Series type Adjustable thermal and fixed Magnetic setting,lcs=100% of lcu Make Havells Cat No IHA13EBF0100 # (Incoming)=01 Nos
MCCB 63 Amps 3 pole10 KA (out going)= 01 Nos
MCB Isolator 40 Amps SPN 10 KA (out going)=04 Nos
LED Pilot Lamp RYB 22.5 mm dia= one set of three
Necessary foundation in PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 Job Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dence soil around the plateform of transformer, GOD's and E&M installation and deposites removal materials 50 mtr away from the site all as specified and directed.
M&L for 20 graded stone aggregate 50mm thick as in floor at transformers, main receiving stn all as specified and directed.
M&L cement concrete type B- 1:2:4 (40 mm graded crushedsyone aggregate ) 80 mm thick as in floor including demolition of existing PCC floor and removing vegetation by roots throughly cleaning complete all as specified and directed by Engr -in- charge
M & L for frame work as in door or gate of angle or other section with gaskit plate, rail, bracket etc complete drilled for fixing steel sheeting or other covering, door etc to prepare for hanging or sliding with and including other lock or hinget, welding, cutting all as specified and directed.
M & L for expanded metal wt not less than 4 kg per sq/mtr cut to length, bend to shape, required and hings with and annealed mild steel line not less than 0.96mm dia or with galvanised steel stepless supplied and fixed to steel members all as specified and as directed.
M & L for new surface of steel of any description, over 10 cm in width or girth not other are described complete with preparation of new surface and paint with two coat of aluminium paint over a coat of red oxide primer all as specified and as directed.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing surface internally and externally incl prepration of old rusted surface after taking proper shut down complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking ou joints,hacking for key scrubbing down with water and removing un serviceable materials outside tha cantt area all as specified and directed by Engr-in-charge.
M&L rendering 20 mm thick (average) in CM 1:4 on concrete surface /brick surface and similar including two or more dubbing coat,surface finished even and fair without using extra cement with necessary formwork,scaffolding for external surface all as specified and as directed by Engr-in-charge.
Supply and Fix in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 100 Amp, 415 volts 3 phase , four pole complete all as specified and directed by Engr-in-charge. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically to a depth not less than 3 mtr below ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level,earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers,all around,top and bottom and electrode connection by using galvanised iron earth lead wire 4mm dia by means of bolts,nuts,check nut,and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 15mm bore protection pipe light grade for protection strip upto 3m above ground level fixed with two clamps of size 25mmx3mm flat iron and connected to running earth wire at top of poles for for protection of GI wire.PCC chambeer in cement concrete(1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:-
The unit rate shall include for protection pipe, GI water pipe, funnel,wire mesh excavation,RCC pit cover,test point,4 mm dia galvanised iron wire from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m,no price adjustment shall be made.
PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.
If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account.
Earthing work will be carried out in presence of MES representative.
M&L preparing plastered or unplastered new/ old surfaces of walls/ plinths of transformer and applying three coats of white wash complete all as specified and as directed.
M/S Gh Qadir and Sons
Vishesh Engineers
SUMEET TRADING CORPORATION
Sarbat Construction Co
Jiwan Singh
Bidder Name
M/S Gh Qadir and Sons
Vishesh Engineers
Jiwan Singh
Sarbat Construction Co
SUMEET TRADING CORPORATION
M/S Bali Agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .