Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance MUZAFFARNAGAR MEERUT ROAD GEHRA BAGH OPP PWD WARE HOUSE MUZAFFARNAGAR UTTAR PRADESH 251002 | MUZAFFARNAGAR | UTTAR PRADESH | 251002 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
Tender Value
₹14.1 L
EMD Value
₹14,000
Closing Date
3 Mar 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MUZAFFARNAGAR
NEAR 132 KV SUB STATION BHOPA ROAD MUZAFFARNAGAR
WORK TENDER
2023_UPTCL_769793_1
ETC MU T 114 2022 23
Open Tender
Electrical Works
Item Rate
60 days
SHAMLI
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD MUZAFFARNAGAR
₹14,000
17 Apr 2023
28 Jan 2023
4 Mar 2023
28 Jan 2023
3 Mar 2023
28 Jan 2023
Amount
SCHEDULE Q-1 MATERIAL (SUPPLY)
SUPPLY OF THREE BOLTED TYPE PG CLAMP MADE OF ALU ALLOY LM-6 SUITABLE FOR PANTHER TO PANTHER CONDUCTOR
SUPPLY OF FOUR BOLTED TYPE PG CLAMP MADE OF ALU ALLOY LM-6 HAVING 04 NOS BOLTS SUITABLE FOR MOOSE TO PANTHER CONDUCTOR
SUPPLY OF FOUR BOLTED TYPE PG CLAMP MADE OF ALU ALLOY LM-6 HAVING 04 NOS BOLTS SUITABLE FOR MOOSE TO MOOSE CONDUCTOR
SUPPLY OF FOUR BOLTED TYPE PG CLAMP MADE OF ALU ALLOY LM-6 HAVING 04 NOS BOLTS SUITABLE FOR ZEBRA TO PANTHER CONDUCTOR
SUPPLY OF SINGLE TENSION FITTINGS SUITABLE FOR ACSR PANTHER CONDUCTOR ALONG WITH ALL ASSOCIATED ACCESSORIES
SUPPLY OF DOUBLE TENSION FITTINGS SUITABLE FOR ACSR PANTHER CONDUCTOR ALONG WITH ALL ASSOCIATED ACCESSORIES
SUPPLY OF JUNCTION BOX SUITABLE FOR 145 KV CT HAVING TERIMINAL CONNECTORS AND COMPLETE IN ALL RESPECT AS PER STD TECHNICAL SPECIFICATIONS.
SUPPLY OF JUNCTION BOX SUITABLE FOR 145 KV PT HAVING TERIMINAL CONNECTORS AND COMPLETE IN ALL RESPECT AS PER STD TECHNICAL SPECIFICATIONS.
SUPPLY OF JUNCTION BOX SUITABLE FOR 36 KV CT HAVING TERIMINAL CONNECTORS AND COMPLETE IN ALL RESPECT AS PER STD TECHNICAL SPECIFICATIONS.
SUPPLY OF 33 KV ISOLATOR CLAMP MADE OF ALU LM-6 ALLOY SUITABLE FOR TWIN MOOSE CONDUCTOR
SUPPLY OF 33 KV CIRCUIT BREAKER CLAMP MADE OF ALU LM-6 ALLOY SUITABLE FOR TWIN MOOSE CONDUCTOR AS PER SAMPLE.
SUPPLY OF 33 KV CT CLAMP MADE OF ALU LM-6 ALLOY SUITABLE FOR TWIN MOOSE CONDUCTOR
SUPPLY OF BUS POST CLAMP SUITABLE FOR ACSR PANTHER
SUPPLY OF 33 KV LA CLAMP SUITABLE FOR ACSR TWIN MOOSE AS PER SAMPLE.
SUPPLY OF CLAMP SUITABLE FOR LV BUSHING OF 63 MVA 132/33 KV TRANSFORMER FOR TWIN MOOSE AS PER SAMPLE.
SUPPLY OF BOLTED TYPE TENSION FITTING FOR ACSR TWIN MOOSE CONDUCTOR WITHOUT TURN BUCKLE FOR 33 KV MAIN BUS SUITABLE FOR EACH DISC STRING 10 NOS DISC INSULATORS WITH HARDWARE FITTING D-SHACKLE, SOCKET BALL HOOK, YOLK PLATE ETC. AS PER STDNDRAD TECHNICAL SPECIFICATIONS.
SUPPLY OF BOLTED TYPE TENSION FITTING FOR ACSR TWIN MOOSE CONDUCTOR WITH TURN BUCKLE FOR 33 KV MAIN BUS SUITABLE FOR EACH DISC STRING 10 NOS DISC INSULATORS WITH HARDWARE FITTING D-SHACKLE, SOCKET BALL HOOK, YOLK PLATE ETC. AS PER STDNDRAD TECHNICAL SPECIFICATIONS.
SUPPLY OF SPACERS SUITABLE FOR MOOSE TO MOOSE CONDUCTOR FOR 33 KV MAIN BUS AS PER SAMPLE
SUPPLY OF 05 BOLTED TYPE SINGLE TENSION FITTING SUITABLE FOR ACSR PANTHER FOR 132 KV MAIN BUS WITH HARDWARE FITTING, D-SHACKLE, SOCKET, BALL HOOK, YORK PLATE ETC. AS PER SAMPLE.
SUPPLY OF 02 BOLTED TYPE SINGLE SUSPENSION FITTING WITH HARDWARE FITTING, D-SHACKLE, EYE SOCKET, YORK PLATE ETC SUITABLE FOR ACSR PANTHER FOR 132 KV JACK BUS AS PER STD TECHNICAL SPECIFICATIONS.
SUPPLY OF 145 KV ISOLATOR CLAMP MADE OF ALU LM-6 ALLOY SUITABLE FOR ACSR PANTHER AS PER SAMPLE
SUPPLY OF PERFORATED CABLE TRAYS WIDTH 75 MM
SUPPLY OF PERFORATED CABLE TRAYS WIDTH 150 MM
SCHEDULE Q-2 (WORK )
ERECTION OF MAIN STRUCTURE INCLUDING ALL ALLIED WORKS COMPLETE IN ALL RESPECT. DEPARTMENT SHALL PROVIDE EACH AND EVERY NUTS AND BOLTS OF THE STRUCTURE. THE WORK SHALL BE STRICTLY CARRIED OUT AS PER DRAWING AND TECHNICAL SPECIFICATION.
ERECTION OF AUX STRUCTURE INCLUDING ALL ALLIED WORKS COMPLETE IN ALL RESPECT. DEPARTMENT SHALL PROVIDE EACH AND EVERY NUTS AND BOLTS OF THE STRUCTURE. THE WORK SHALL BE STRICTLY CARRIED OUT AS PER DRAWING AND TECHNICAL SPECIFICATION.
ERECTION OF EQUIPMENTS AS PER INSTRUCTION MANUAL OF VARIOUS EQUIPMENTS AND TECHNICAL SPECIFICATION INCLUDING SHIFTING OF MATERIAL EQUIPMENT FROM STORE TO ERECTION SITE INCLUDING ALL OTHER ASSOCIATED WORK WITH THE HELP OF CRANE WHICH WILL BE PROVIDED BY CONTRACTOR AT HIS OWN COST FOR COMPLETION OF THE JOB SATISFACTORILY:-
145 KV CB WITH STRUCTURE
145 KV BUS ISOLATOR
145 KV LINE ISOLATOR
145 KV T/F C&R PANEL
33 KV TRIPLE FEEDER CONTROL AND RELAY PANEL
132 KV DOUBLE FEEDER CONTROL PANEL
132 KV DISTANCE PROTECTION PANEL
132 KV BUS COUPLER PANEL
145 KV CTs
145 KV PTs
120 KV LAs
145 KV BUS POST INSULATORS
APEX ENERGY METER PANEL COMPLETE IN ALL RESPECT
36 KV VCB WITH STRUCTURE
36 KV BUS ISOLATOR
36 KV LINE ISOLATOR
33 KV CT JUNCTION BOX
132 KV CT JUNCTION BOX
132 KV PT JUNCTION BOX
Destringing of three phase conductor of following 132 KV transmission lines having ACSR panther conductor from dead end tower to substation gantry. Work includes carriage of old conductor from site to UPPTCL store if necessary. All T&P, labour required to do the work satisfactorily shall be arranged by the contractor: 1. 132 kv Shamli(400)-budhana line. 2. 132 Kv shamli(220)-budhana line. (Note- a.Existing Shamli(400) bay will be shifted to existing bus coupler bay. b. Existing Shamli(220) bay will be shifted to existing shamli(400) bay. c. Existing shamli(220) bay will be converted to new 63 MVA T/F bay. d. New 132 kv bus coupler bay is to be constructed.)
Stringing of three phase conductor of following 132 KV transmission lines having ACSR panther conductor from dead end tower to substation gantry. Work includes carriage of new conductor from UPPTCL store to site if necessary. All T&P, labour required to do the work satisfactorily shall be arranged by the contractor: 1. 132 kv Shamli(400)-budhana line. 2. 132 Kv shamli(220)-budhana line. (Note- a.Existing Shamli(400) bay will be shifted to existing bus coupler bay. b. Existing Shamli(220) bay will be shifted to existing shamli(400) bay. c. Existing shamli(220) bay will be converted to new 63 MVA T/F bay. d. New 132 kv bus coupler bay is to be constructed.)
Interconnection of equipments with specified conductor with 132 KV main and transfer bus including cutting, bending of conductor and jumpering, clamping as per drawing and technical specification to complete the following 132 KV bays in all respect: 1. 132 KV Shamli(400) bay 2. 132 KV Shamli (220) bay 3. 132 KV new 63 MVA T/F bay. 4. 132 KV new bus coupler bay. (Note- a.Existing Shamli(400) bay will be shifted to existing bus coupler bay. b. Existing Shamli(220) bay will be shifted to existing shamli(400) bay. c. Existing shamli(220) bay will be converted to new 63 MVA T/F bay. d. New 132 kv bus coupler bay is to be constructed.)
Stringing and proper sagging of new overhead 132 kv jack bus of 63 MVA 132/33 KV T/F of three phases with ACSR panther conductor for approx 60 mtr span. The work involves cutting of conductor, making of busbar of suitable length, fitting of tension fittings, hoisting of 70/120 KN disc insulator etc and stringing. All material shall be supplied bybthe department free of cost and work also include shifting all material from store to site in switchyard and all other associated works to complete the job satisfactorily.
Earthing of substation structure and various equipments and cable racks with etc. with already laid earthmat laid 800 mm below ground by various size MS flat including excavation and backfilling of earth after completion of work, straightening, bending, cutting, welding and drilling holes including painting of MS flat with one coat of red oxide and two coat of bus green paint above ground and in trenches and one coat of red oxide and two coat of black bituminous paint of best quality on all underground joints for proper completion of work.
Laying and dressing of control cable in trenches after removal of trench covers as per cable schedule including clamping with 25x3 mm Al strip and GI nut and bolts including cutting, peeling of the control cable.
2x2.5 sqmm
4x2.5 sqmm
6x2.5 sqmm
Termination of cables as laid above as per cable schedule (provided by contractor) including making necessary holes in panel base plate or junction box as per site requirement including fixing of cable gland of appropriate size. Supply and fixing ferrules on each core of cable and its termination and other associated work to complete the job satisfactorily. (Glands will be provided by department free of cost.)
Laying of 40 mm size MS round bar below 800 mm from ground level including cutting, straightening, welding, painting of joints, excavation of trench, its backfilling and all other associated work to complete the job satisfactorily.
Fabrication of 3 meter long electrodes with MS rod having 150 mm long conical shape and then its piercing vertically inside the ground from 800 mm below ground level and its welding with main earthmat including cost of consumble materials, men and T&P excluding the cost of 40mm MS round.
Earthing of 132 KV LAs with 75x10 mm MS flat after making rectangular configuration along with six nos (03 meter length) 40 mm dia MS electrodes as per drawing and technical specifications. Work includes fabrication of 3 meter long electrodes with MS rod having 150 mm long conical shape.
Earthing of 33 KV LAs with 50X6 mm MS flat after making rectangular configuration along with four nos (03 meter length) 40 mm dia MS electrodes as per drawing and technical specifications. Work includes fabrication of 3 meter long electrodes with MS rod having 150 mm long conical shape.
Stringing and extension of 33 KV main bus section (R,Y,B phases) with ACSR twin moose conductor 15 mtr span. The work involves cutting of conductor, making of busbar of suitable length, fitting of tension fittings, hoisting of 120 KN disc insulator etc. and stringing. All material shall be supplied by the department free of cost. Work also include shifting all material from store to site in switchyard and all other associated works to complete the job satisfactorily.
Connecting of U-shape jumper R,Y,B phase of 33 KV main bus of ACSR twin moose, work includes jointing of ACSR moose conductor below the gantries with the help of suitable PG clamps and spacer and cutting of conductor as required and all other associated work to complete the job satisfactorily.
Uninstallation of 36 KV CTs and their shifting from switchyard to store.
Uninstallation of 36 KV BI and its shifting from switchyard to store.
Uninstallation of 36 KV BI with structure and its shifting from switchyard to store.
Uninstallation of 36 KV LI and its shifting from switchyard to store.
Uninstallation of 36 KV LI with structure and its shifting from switchyard to store.
Uninstallation of 36 KV PIs with structure and its shifting from switchyard to store.
Uninstallation of 36 KV VCB with structure and its shifting from switchyard to store.
Interconnection of equipments with specified conductor with 33 KV main bus including cutting, bending of conductor and jumpering, clamping as per drawing and technical specification to complete the 33 KV bay in all respect. Work also includes removal of existing conductor if necessary.
ANSH ELECTRICAL AND ENGINEERING WORKS
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
P&H Engineering
KARAN SINGH
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .