| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance 158 RAKSA SHIVPURI ROAD JHANSI RAKSA JHANSI JHANSI JHANSI UTTAR PRADESH 284419 | JHANSI | UTTAR PRADESH | 284419 | ₹2.8 L | L1 | Accepted-Finance Selected |
| 2 | L2₹3.6 LAccepted-Finance 50 3 S F ARJUN NAGAR NEW DELHI 110029 | SOUTH | DELHI | 110029 | ₹3.6 L | L2 | Accepted-Finance Selected |
| 3 | L3₹3.9 LAccepted-Finance 30 74 BLOCK NO EXTRA 30 TRILOK PURI DELHI EAST DELHI 110091 | EAST | DELHI | 110091 | ₹3.9 L | L3 | Accepted-Finance Selected |
| 4 | L4₹4.4 LAccepted-Finance | ₹4.4 L | L4 | Accepted-Finance Selected |
| 5 | L5₹4.6 LAccepted-Finance NONE | ₹4.6 L | L5 | Accepted-Finance Selected |
Tender Value
₹4.9 L
EMD Value
₹9,872
Closing Date
30 Jun 2026, 3:00 pmClosed
Assistant Engineer (E),
Assistant Engineer(E), PWD, South East, EMSD-I, Thyagraj Sports Complex, New Delhi-110003
Maintenance of various E and M Services at Thyagraj Sports Complex, New Delhi. (SH- SITC of various type LED Fittings, fans and Painting work and other Misc. Elect. Work).
2026_PWD_294313_1
65/EE (E)/AE (E)-I/EMD South East/PWD/2026-27
Open Tender
Miscellaneous Works
30 days
As per Site
Please refer the tender documents
13 documents required · 13 mandatory
₹0
₹9,872
Yes
1 Jul 2026
25 Jun 2026
30 Jun 2026
25 Jun 2026
30 Jun 2026
25 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | 1 | Nos. | - | - |
| 1.1 | Group C | 30 | Nos. | - | - |
| 2 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 1 | Nos. | - | - |
| 2.1 | 12 way , Double door | 5 | Nos. | - | - |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Nos. | - | - |
| 3.1 | Single pole | 50 | Nos. | - | - |
| 3.2 | Double pole | 10 | Nos. | - | - |
| 4 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV
with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical
circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 1 | Nos. | - | - |
| 4.1 | 18- 22 Watt | 35 | Nos. | - | - |
| 5 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm | 1 | Nos. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
BOQ_391273.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid