Tender Value
₹60.2 L
EMD Value
₹1.2 L
Closing Date
5 Oct 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverof [V/N or 'V' whichever is less; where V = Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer must havesuccessfully completed any of the following during last 07(seven) years,ending last day of month previous to the one in which tender is invited:Three similar nature of works each costing not less than the amountequal to 30% of the advertised value of the tender, or Two similar natureof works each costing not less than the amount equal to 40% of theadvertised value of the tender, or One similar nature of work eachcosting not less than the amount equal to 60% of the advertised value ofthe tender. (b) (i) In case of tenders for composite works (e.g. worksinvolving more than one distinct component, such as Civil Engineeringworks, S&T works, Electrical works, OHE works etc. And in the case ofmajor bridges - substructure, superstructure etc.), the tenderer musthave successfully completed any of the following during last 07 (seven)years, ending the last day of the month previous to the one in whichtender is invited: Three similar nature of works each costing not lessthan the an amount equal to 30% of the advertised value of eachcomponent of the tender, or Two similar nature of works each costing notless than the amount equal to 40% of the advertised value of eachcomponent of tender, or One similar nature of work each costing not lessthan the amount equal to 60 % of the advertised value of eachcomponent of the tender. Note for b(i): Separate completed works ofminimum required values for each component shall also be consideredfor fulfillment of technical eligibility criteria. (b) (ii) In such cases, whatconstitutes a component in a composite work shall be clearly predefinedwith estimated tender cost of it, as part of the tender documents withoutany ambiguity. (b) (iii) To evaluate the technical eligibility of thetenderer, only components of work as stipulated in tender documents forevaluation of technical eligibility shall be considered. The scope of workcovered in other remaining components shall be either executed by thetenderer himself if he has work experience as mentioned in clause 7 (a)(ii) of Part-II of GCC or through subcontractor fulfilling the requirementsas per clause 7 of Part-II of GCC or jointly i.e., partly himself andremaining through subcontractor, with prior approval of Chief Engineerin writing. However, if required in tender documents by way of SpecialConditions, a formal agreement duly notarised, legally enforceable in thecourt of law, shall be executed by the main contractor with thesubcontractor for the component(s) of work proposed to be executed bythe subcontractor(s), and shall be submitted along with the offer forconsidering subletting of that scope of work towards fulfillment oftechnical eligibility. In case after the award of the contract or during theexecution of work it becomes necessary for the contractor to changesubcontractor, the same shall be done with subcontractor(s) fulfilling therequirements as per clause 7 of Part-II of GCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor licenseas per Indian Electricity Rules for the respective category ofworks issued by Government Electrical License Board on orbefore the closing date of tender. Copy of the electricalcontractor license should be submitted along with the tenderoffer, otherwise, the tender will be summarily rejected.
54 conditions · 6 needing a document upload
Whether the cost of earnest money deposited
Whether cost of tender document deposited.
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE AND SUPERVISOR LICENCE SUBMITTED
Payment of Earnest Money deposit (EMD) & Tender Document Cost (TDC), in respect of e-tendering,should be accepted through net banking or online payment gateway only
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Silchar- Augmentation of Rolling Stock facilities at Silchar Coaching Depot.(Electric Portion) and At PNO: Provision of Rest room for track machine staff at ZTMD/PNO(Electric portion).
EL-LM-26-27-07~NFR
EL-LM-26-27-07
Open
Works - General
180 Days
Hojai, Assam
₹0
₹1.2 L
10 Sept 2026
10 Sept 2026
21 Sept 2026
116 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 50,29,652.62 | ||
| — | 70.00 | — | — | ||
| Supply, installation, testing and commissioning of integral industrial type LED Flood Light, 150 W, pressure die-cast aluminium housing with toughened glass diffuser, minimum IP65 protection, system efficacy not less than 130 lm/W, LED driver efficiency 85%, power factor 0.95, THD 10%, input supply voltage 140-277 V AC, 50 Hz, complete with constant current driver, surge protection, mounting bracket, hardware, internal wiring and all accessories required for satisfactory operation. The luminaire shall be complete in all respects and conform to the latest applicable IS/IEC standards. | — | — | — | 7,70,000 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of constant voltage Battery Charger, input 415 V AC, 3 Phase, 50 Hz and output 110-155 V DC, 1 x 200 A (single circuit), complete with input/output isolating switches, input MCCB, AC/DC protection fuses, voltmeter, ammeter, fine and coarse voltage selection switches, constant voltage/current charging arrangement, short-circuit, overload, over-voltage, over-current and thermal protection, charge/trip indications, reset switch, LED indications for protections and R-Y-B phase healthy status, enclosed in floor-mounted powder- coated sheet steel cubicle with lockable doors and heavy-duty wheels for easy movement, complete with all internal wiring, terminals, accessories and hardware required for satisfactory operation. The battery charger shall conform to relevant IS/IEC standards. Any item not specifically mentioned but essential for safe, reliable and efficient operation shall be deemed included in the scope without any extra cost. The equipment shall be approved by the Engineer-in-Charge before supply. Complete installation, testing and commissioning shall be carried out as per the directions of the Engineer-in- Charge at site. | — | — | — | 4,53,282.78 | |
| — | 300.00 | — | — | ||
| Supply, installation, testing and commissioning of 30 W LED Flood Light Luminaire suitable for 110 V DC supply for pit lighting, complete with pressure die-cast aluminium housing, toughened glass cover with Teflon gasket ensuring minimum IP66 protection, system wattage not exceeding 30 W, minimum system lumen output of 3000 lumens, high-efficiency SMD LEDs (Cree/Nichia/Osram/Seoul or equivalent), integral driver of the same make as the luminaire, complete with mounting bracket, internal wiring, fixing hardware and all accessories required for satisfactory operation. The luminaire shall conform to the latest applicable IS/IEC standards and shall carry a minimum 5-year comprehensive warranty from the date of commissioning. | — | — | — | 10,08,432 | |
| — | 1500.00 | — | — | ||
| Supply of ISI marked 2 Core x 4 sq.mm, 1100 V grade, XLPE insulated, PVC sheathed, unarmoured aluminium conductor cable conforming to IS 7098 (Part 1): 1988 with latest amendments/revisions, suitable for power distribution, complete in all respects. | — | — | — | 1,06,560 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing and commissioning (SITC) of IP65 rated Loop-In Loop-Out Junction Box, made of UV-stabilized polycarbonate/thermoplastic enclosure, minimum size 205 x 255 x 112 mm, provided with metric knockouts for cable entry, suitable for termination of cables up to 25 sq.mm, complete with terminal blocks, gland plate, cable glands, mounting hardware, sealing gaskets, fixing accessories and all other materials required for satisfactory installation and operation, conforming to the latest applicable IS/IEC standards. | — | — | — | 1,08,356.7 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing and commissioning of 32 A, Double Pole (DP) MCB complete with 32 A, 3-pin (2P+E) industrial plug and socket, housed in a weatherproof IP65 enclosure, suitable for 230 V AC, 50 Hz supply, complete with mounting accessories, internal wiring, cable glands, terminals, hardware and all other accessories required for safe and satisfactory operation, conforming to the latest applicable IS/IEC standards. The work shall be carried out as per the directions of the Engineer-in-Charge at site. | — | — | — | 60,460.8 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 32 A, Four Pole (4P) MCB complete with 32 A, 5-pin (3P+N+E) industrial plug and socket, housed in a weatherproof IP65 enclosure, suitable for 415 V AC, 3 Phase, 50 Hz supply, complete with mounting accessories, internal wiring, cable glands, terminals, hardware and all other accessories required for safe and satisfactory operation, conforming to the latest applicable IS/IEC standards. The work shall be carried out as per the directions of the Engineer-in-Charge at site. | — | — | — | 36,619.4 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing and commissioning of 60 W LED Flood Light Luminaire suitable for 230 V AC, 50 Hz supply, with minimum system efficacy of 130 lm/W, pressure die-cast aluminium housing, toughened glass diffuser, integral constant-current LED driver, minimum IP66 protection, power factor 0.95, THD 10%, surge protection, corrosion-resistant mounting bracket, complete with fixing hardware, internal wiring and all accessories required for satisfactory operation. | — | — | — | 1,93,000 | |
| — | 500.00 | — | — | ||
| Supply, installation, testing and commissioning of heavy-duty rigid PVC conduit, 25 mm dia, ISI marked, suitable for surface or recessed wiring, complete with all accessories such as bends, couplers, junction boxes, inspection boxes, saddles, spacers, bushes and solvent cement, including cutting chases in walls, fixing the conduit, making good the damaged surface with cement mortar and finishing to match the existing surface in case of recessed installation, complete in all respects as required and conforming to IS 9537 (Part 3) and the latest applicable IS standards. | — | — | — | 10,970 | |
| — | 500.00 | — | — | ||
| Supply, laying, fixing and testing of 40 mm dia HDPE pipe, PN-6 (working pressure 6 kgf/cm²), ISI marked, suitable for protection of underground cable, laid partly underground and partly above ground, including excavation and backfilling wherever required, fixing on walls/poles/structures with suitable heavy-duty MS clamps, saddles, nuts, bolts and washers, providing necessary HDPE fittings, bends, couplers and accessories, complete in all respects as per the directions of the Engineer-in-Charge and conforming to the latest applicable IS standards. | — | — | — | 23,700 | |
| — | 1500.00 | — | — | ||
| Supply of ISI marked size 4 core 6 sq.mm XLPE insulated, PVC outerseathed unarmoured cable with aluminium conductor, suitable for 1100 Volt grade IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005. | — | — | — | 1,79,655 | |
| — | 250.00 | — | — | ||
| Supply, laying, fixing and testing of 6 SWG hot-dip galvanised iron (GI) wire conforming to IS 280, complete with necessary clamps, saddles, fasteners and accessories for fixing on walls, structures or equipment as required, including all labour and materials, complete in all respects as per the directions of the Engineer-in-Charge. | — | — | — | 10,500 | |
| — | 1200.00 | — | — | ||
| Supply, laying, jointing, fixing and testing of 25 mm x 5 mm hot-dip galvanised iron (GI) strip for earth continuity/strip earth electrode, laid at a depth of 0.5 m below ground level, including excavation, backfilling and making good the surface, complete with GI nuts, bolts, spring washers and other accessories for termination. Jointing shall be carried out by overlapping the strips and fastening with two sets of GI nuts, bolts and spring washers spaced 50 mm apart, complete in all respects as per the directions of the Engineer-in-Charge and conforming to the latest applicable IS standards. | — | — | — | 1,72,800 | |
| — | 15.00 | — | — | ||
| Supply and erection of earthing by made of B class GI pipe of 4000 mm length, 50 mm diameter &3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with at apered casing at the lowerend in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil.Where soil restivity is high,earth restivity enhancing material may be used,Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg.No. DRG NO: PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | — | — | — | 20,219.1 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of TPN Junction Box, 200 A, suitable for 415 V AC, 3 Phase, 4 Wire, 50 Hz system, fabricated from CRCA sheet steel with powder-coated finish and minimum IP65 protection, complete with 200 A high-conductivity electrolytic copper busbars (Phase, Neutral and Earth), suitable incoming and outgoing cable termination arrangement, shrouded busbars, insulated supports, removable gland plates, cable glands, terminals, earthing studs, danger notice, mounting hardware and all accessories required for safe and satisfactory operation, complete in all respects and conforming to the latest applicable IS/IEC standards. | — | — | — | 2,54,100 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of TPN Junction Box, 100 A, suitable for 415 V AC, 3 Phase, 4 Wire, 50 Hz system, fabricated from CRCA sheet steel with powder-coated finish and minimum IP65 protection, complete with 100 A high-conductivity electrolytic copper busbars (Phase, Neutral and Earth), suitable incoming and outgoing cable termination arrangement, shrouded busbars, insulated supports, removable gland plates, cable glands, terminals, earthing studs, danger notice, mounting hardware and all accessories required for safe and satisfactory operation, complete in all respects and conforming to the latest applicable IS/IEC standards. | — | — | — | 2,03,025 | |
| — | 700.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. | — | — | — | 28,651 | |
| — | 25.00 | — | — | ||
| Supply, spreading, dressing and filling of approved quality stone dust in switchyard to the required thickness, including levelling, compaction, dressing and finishing the surface, complete with all labour, loading, unloading, transportation and incidental materials required for proper completion of the work, as directed by the Engineer-in-Charge at site. | — | — | — | 32,707.5 | |
| — | 30.00 | — | — | ||
| Supply, spreading and dressing of clean, hard, washed 40 mm graded pebbles/crushed stone in the switchyard to the required thickness, including loading, unloading, transportation, levelling, proper dressing and finishing, complete with all labour, tools, tackles and incidental materials required for satisfactory completion of the work, as directed by the Engineer-in- Charge at site. | — | — | — | 36,338.4 | |
| — | 250.00 | — | — | ||
| Supply, laying, fixing and testing of 50 mm (OD) Double Wall Corrugated (DWC) HDPE pipe, PN-6.0 (working pressure 6 kgf/cm²), ISI marked, suitable for protection of underground/overground power cables, laid partly above ground and partly underground, including excavation, backfilling and restoration wherever required, fixing on walls, poles or structures with suitable heavy-duty MS clamps, saddles, nuts, bolts and washers, providing necessary sockets, couplers, bends and other fittings, complete with all accessories, labour and incidental materials required for satisfactory installation, as directed by the Engineer-in-Charge and conforming to the latest applicable IS standards. | — | — | — | 15,357.5 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, installation, testing and commissioning of LT control panel outdoor type of double door construction, FORM-3b as per IEC 60439-1 standards with IP 54/55 and 415 V 3phase &4 wire system, rear access type. The panel colour shall be RAL 7035 structured finish. cable entry incoming=bottom,outgoing=bottom.Horizontal 400 a copper busbar will be running at the top throughout the panel Enclosure shall be of CRCA steel sheet type. load bearing parts shall have 2mm thickness & non-loading parts shall have 1.6mm thickness. Gland plate shall be 3mm of GI type. the busbar system shall have heat shrinkable colored PVC sleeve. main busbar (power bus) is TPN electrolytic copper busbar size (50x6)mm. Doors and covers shall be gasketed by Neoprene gaskets. Control wires shall be 1.1KV grade Copper Flexible conductors. Panel should have short circuit strength at 100KA for 1 seconds as per IS:8623 part-I and temperature rise test at 6300 A as per IS:8623 part-1.The panel shall also consist of multifunction meter, CT, LED indicating lamps, auxiliary contractors, selector switches, cam switches etc as per manufacturer specification /recommendation & Cable alley also. the panel shall be provided with 3nos bus bar for phases made of electrolytic grade of copper bar of each (50x6) mm. the incoming switches shall beconnected with bus bar by crimping sockets on bus bar of panel side. the bar shall be connected by on either side by porcelain insulator and sufficient clearance shall be maintained inside the bus bar doe easy maintenance. Drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. The panel shall be fabricated from 2 mm thick consisting of . (i) MCCB 400 Amps 4pole 50 KA = 2 nos. (v) MCCB 250 Amps 4pole 36 KA = 2 nos.,(vi) MCCB 100 Amps 4pole 25 KA = 2 nos. (vii) MCCB 63 Amp 4 pole, 25 ka=2 nos. Ics=100%Icu with adjustable thermal magnetic release setting confirming to IEC 60947- 2.The contractor shall submit GA, SLD and fabrication drawings for approval before manufacture. The panel shall be manufactured by an ISO 9001 certified, CPRI-tested and BIS/ISI compliant manufacturer. Routine and acceptance tests shall be carried out at the manufacturer's works, and pre-dispatch inspection shall be conducted in the presence of the Railway's authorised representative before dispatch. | — | — | — | 3,94,700 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, installation, testing and commissioning of LT control panel outdoor type of double door construction, FORM-3b as per IEC 60439-1 standards with IP 54/55 and 415 V 3phase &4 wire system, rear access type. The panel colour shall be RAL 7035 structured finish. cable entry incoming=bottom,outgoing=bottom.Horizontal 400 Amp busbar,12 way will be running at the top throughout the panel Enclosure shall be of CRCA steel sheet type. load bearing parts shall have 2mm thickness & non-loading parts shall have 1.6mm thickness. Gland plate shall be 3mm of GI type. the busbar system shall have heat shrinkable colored PVC sleeve. main busbar (power bus) is TPN electrolytic copper busbar size (50x6)mm. Doors and covers shall be gasketed by Neoprene gaskets. Control wires shall be 1.1KV grade Copper Flexible conductors. Panel should have short circuit strength at 100KA for 1 seconds as per IS:8623 part-I and temperature rise test at 6300 A as per IS:8623 part-1.The panel shall also consist of multifunction meter, CT, LED indicating lamps, auxiliary contractors, selector switches, cam switches etc as per manufacturer specification /recommendation & Cable alley also. the panel shall be provided with 3nos bus bar for phases made of electrolytic grade of copper bar of each (50x6) mm. the incoming switches shall beconnected with bus bar by crimping sockets on bus bar of panel side. the bar shall be connected by on either side by porcelain insulator and sufficient clearance shall be maintained inside the bus bar doe easy maintenance. Drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. The panel shall be fabricated from 2 mm thick consisting of . (i) MCCB 160 Amps 4pole 36 KA = 2 nos. (ii) MCCB 63 Amps 4pole 25 KA = 4 nos, Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2. The contractor shall submit GA, SLD and fabrication drawings for approval before manufacture. The panel shall be manufactured by an ISO 9001 certified, CPRI-tested and BIS/ISI compliant manufacturer. Routine and acceptance tests shall be carried out at the manufacturer's works, and pre-dispatch inspection shall be conducted in the presence of the Railway's authorised representative before dispatch. | — | — | — | 2,41,295 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of outdoor weatherproof Feeder Pillar Box of suitable size, fabricated from 14 SWG CRCA/MS sheet with powder-coated finish, complete with structural angle/flat supports, double-door construction with lockable arrangement, neoprene/rubber gasket for dust and water protection, minimum IP55 degree of protection, suitable cable entry with removable gland plate and PVC/nylon cable glands, mounted on four legs grouted in PCC foundation (1:3:6), complete with copper busbars, earthing arrangement, internal wiring, terminals, danger notice, hardware and all accessories. The Feeder Pillar Box shall be provided with the specified MCCBs as per the schedule of quantities/drawings and shall be complete in all respects, conforming to the latest applicable IS/IEC standards and as directed by the Engineer-in-Charge. | — | — | — | 38,073.1 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 63 A, 4 Pole MCCB, 25 kA breaking capacity, Ics = 100% Icu, with adjustable thermal-magnetic trip unit, conforming to IEC 60947-2, complete with busbar connections, interconnections, mounting on the feeder pillar, terminals, hardware and all accessories, for installation inside the outdoor feeder pillar box (Item No. 23), complete in all respects as directed by the Engineer-in-Charge. | — | — | — | 1,47,000 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 16 A, Double Pole (DP), C-Curve MCB, 10 kA breaking capacity, suitable for 230 V AC, 50 Hz supply, conforming to IS/IEC 60898-1, complete with mounting on the feeder pillar, interconnections, terminals, hardware and all accessories required for satisfactory operation, as directed by the Engineer-in-Charge. | — | — | — | 10,000 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing and commissioning of 6 A, Single Pole (SP), C-Curve MCB, 10 kA breaking capacity, suitable for 230 V AC, 50 Hz supply, conforming to IS/IEC 60898-1, complete with mounting on the feeder pillar, interconnections, terminals, hardware and all accessories required for satisfactory operation, as directed by the Engineer-in-Charge. | — | — | — | 8,820 | |
| — | 10.00 | — | — | ||
| Supply, fabrication, installation, testing and commissioning of 100 A TPN busbar system comprising 4 Nos. (3 Phase + Neutral) electrolytic grade aluminium busbars of suitable size, mounted on high-strength insulated busbar supports, complete with heat-shrink/PVC insulated busbar shrouds (insulation cover), busbar clamps, connectors, hardware, interconnections and all accessories required for installation inside the feeder pillar box, suitable for 415 V AC, 3 Phase, 4 Wire, 50 Hz system, complete in all respects and conforming to the latest applicable IS/IEC standards. | — | — | — | 6,720.7 | |
| — | 3.50 | — | — | ||
| Supply, fabrication, galvanizing , erection, alignment, testing and commissioning of GI Portal Structure fabricated from hot-dip galvanised steel angles of size 65 x 65 x 6 mm conforming to relevant IS standards, complete with 16 mm dia GI rod bracings/lacings welded to the main members to form a lattice structure of approximately 450 mm x 300 mm cross-section with vertical lacing spacing of 300 mm. The portal shall comprise Booms: 2 Nos. x 6.0 m and 1 No. x 4.5 m (total boom length 16.5 m), Corner Members: 2 Nos., Pillars/Uprights: 2 Nos., each 9.5 m high, complete with all GI nuts, bolts, spring washers, cleats, gusset plates, base plates, templates, fixing accessories and all incidental materials required for complete erection. The work shall include assembly, alignment, fastening, tightening, touch-up galvanizing/zinc-rich paint at damaged portions, and all labour, tools and tackles required for satisfactory completion, as directed by the Engineer-in-Charge and conforming to the latest applicable IS standards. | — | — | — | 3,36,421.08 | |
| — | 4.00 | — | — | ||
| Supply & erection of PCC/RCC/Shallow foundation of size & depth as per reccommmendation and drawing of the manufacturer of portal structures in proportion 1:2:4 with chips of maximum aggregate size 20mm and less including cement, sand with excavation of earth for foundation of all depth and all places, nature & condition of soil includind de-watering, shoring, shuttering, batching, mixing, placing, levelling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractors own arrangement for portals. The contractor shall submit detailed foundation drawings, design calculations, loading details, sectional drawings, reinforcement details and bar bending schedule (BBS) for approval by the competent Railway authority before commencement of the work. The work shall be completed in all respects as directed by the Engineer-in-Charge and conforming to the latest applicable IS codes and standards. | — | — | — | 15,747.16 | |
| — | 2.50 | — | — | ||
| Supply, fabrication and construction of RCC foundation/slab of size 1.5 m x 1.5 m x 0.5 m using M15 grade reinforced cement concrete with 20 mm nominal size graded coarse aggregate, Ordinary Portland Cement conforming to the latest IS 269/IS 8112/IS 12269, fine aggregate and TMT steel reinforcement of 8 mm to 12 mm dia as per approved reinforcement details, including centering, shuttering, cutting, bending and binding of reinforcement, batching, mixing, laying, vibration, curing, finishing, excavation, backfilling, disposal of surplus earth and all labour, materials, tools, tackles and incidental works required for complete execution, as directed by the Engineer-in-Charge and conforming to the latest applicable IS standards. | — | — | — | 7,394.9 | |
| — | 12.00 | — | — | ||
| Supply, cutting, bending, binding and erection of 8 mm/10 mm dia MS Tor Steel reinforcement for RCC foundation of the portal structure, including binding with 18 SWG GI binding wire, chairs, spacers, cover blocks, laps, hooks and all accessories, complete as per approved drawings, including all labour, tools and tackles required for satisfactory completion of the work, as directed by the Engineer-in-Charge. | — | — | — | 451.68 | |
| — | 7.00 | — | — | ||
| Excavation for foundation in all types of soil and at all depths, including shoring, strutting, shuttering, dewatering wherever required, dressing and levelling of foundation bed, backfilling with excavated or approved borrowed earth after completion of foundation work, compaction in layers, disposal of surplus excavated earth within a lead of 100 m from the foundation location, and all labour, tools, tackles and incidental works required for complete execution, as directed by the Engineer-in-Charge. | — | — | — | 496.02 | |
| — | 20.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-07-final_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .