Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.8 L+₹3.0 L (7.64%)Rejected-Finance 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹43.7 L+₹3.9 L (9.87%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹44.6 L+₹4.8 L (12.1%)Rejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹45.4 L+₹5.7 L (14.2%)Rejected-Finance C O AMBU HOTEL NEAR GOVT POLYTECHNIC DOLLY GUNJ PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹42.9 L
EMD Value
₹85,800
Closing Date
1 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Vivekanand Pathak, Garrison Engineer
GE (South) Diglipur RK Gram Diglipur North Andaman 744202
PROVN OF PORTA CABIN AT BERKLEY POINT UNDER GE (SOUTH) DIGLIPUR
2024_MES_645286_2
8968/E8
Open Tender
Civil Works
Item Rate
270 days
DIGLIPUR
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (South) Diglipur
₹85,800
Yes
16 Jul 2024
10 Apr 2024
3 May 2024
10 Apr 2024
1 May 2024
24 Apr 2024
Amount
Surface excavation not exc.30cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed..
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Excavating in trenches exc 1.5 m wide and not exc 3.0 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for hard core broken stone of guage not exc. 63mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rolled / rammed to a true surface complete all as specified and as directed.
M & L for plain cement concrete 1:4:8 type D2 (using 40mm granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M & L for rough finished formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed.
M&L for rough finished formwork of Square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface complete all as specified and directed.
M & L for RCC M-30 grade Design Mix (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for RCC M-30 grade Design Mix (using 20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed
M & L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
-ditto- all as per Item no. 12 above but 5 mm dia and over upto and including 10 mm dia as in stirrups , spacers and binders complete all as specified and directed.
M&L for pre-cast cement concrete solid block masonry exc 10cm in width with minimum compressive strength of 50Kg/sqcm using PCC 1:3:6 type C-1 (using 20mm graded aggregate) set in cement mortar 1:6 all as specified and directed.
M&L for damp proof course in cement concrete 1:2:4 type B-0, 40 mm thick including necessary form work with WPC as per manufacture instruction by weight of cement complete all as specified and directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and directed.
M&L for 50mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in floor finished even smooth using extra cement complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C2 (using 40mm garade aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6, including finishing even and smooth without using extra cement complete all as specified and directed.
M & L for 15mm thick rendering on brick work or concrete surface in two coats 10mm thick in CM(1:6) as under coat 5mm thick CM (1:4) as finishing coat mixed with integral water proofing compound only with integral waterproofing compound @ 3% by weight of cement finished even and smooth without using extra cement complete all as specified and as directed. (Note: Water proofing compund shall be measured and paid seperately)
Supply only integral water poofing compound complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410-W(Gde-E-250) quality B complete all as specified and directed.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161- 1979 grade St.-240 complete all as specified and directed.
S&F for MS plates (plain or chequered) channels, square cut or notched with fabrication and erection of Fe 410-W (Gde E-250) quality A (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F for mild steel bolt length exc. 5cm but not exc. 10cm and dia of neck 11 to 15 mm dia screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for mild steel flat iron 40 x 3 mm size as in valley gutter, wind tie and similar work including securing bolt and necessary driling work conforming to fe 290 Gde - 165 complete all as specified and directed.
S & F for aluminium alloy wire cloth 0.45mm nominal dia of wire and average with of aperture 1.40mm and fixed with aluminium wire stples and wooden beading complete all as specified and directed.
M&L for PCC 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in kerb complete all as specified and directed.
M&L for chequered cement concrete tiles with grey cement and pigment of size 200 x 200 x 25mm, set jointed and pointed in neat cement slurry over & including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 100 mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for PCC type B1 1:2:4 (using 20mm graded granite stone aggregate) 150mm thick as in floor finished even smooth using extra cement complete all as specified and directed.
M & L for forming 12 mm thick & 150 mm deep expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed compound,Grade 'B' complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone agregate) as in foundation etc complete all as specified and directed.
M&L for pre-cast cement concrete solid block masonry exc 10cm in width with minimum compressive strength of 50Kg/sqcm using PCC 1:3:6 type C-1 (using 20mm graded aggregate) set in cement mortar 1:4 complete all as specified and directed.
M & L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping suface channels, benching etc of manholes finished fair and even complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:4 for finishing the surface even and smooth without using extra cement complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armored, electric cables (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes cross-sectional area 3.50 core 25 Sqmm complete all as specified and directed.
S & F for 40mm dia GI pipe light grade with necessary fittings in trenches / floor / pillar / fixed on pole etc for cable protection complete all as specified and directed.
S & F for LED steet light fitting 60 Watts 230 Volts , AC outdoor type with high pressure die cast aluminium hosing and heat resistant completee with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F for GI bracket bent of shape drilled welded made out of suitable size of angle iron for fixing of street light fitting of any type and discription including clamps, nuts, bolts and washers complete all as specified and directed by Engineer-In-Charge.
M&L for sub main wiring with FRLSH Copper cable in surface type 2 X 2.5 sqmm and 1 X 2.5 sqmm for earth wire drawn in 15mm dia light grade pipes complete all as specified and directed.
S & F for LT junction box for LED street light, sheet moulding compound (SMC) type with hinged type door and locking arrangment , off with colour oof size 140 X 140 X 105mm (internal) comprising 6 Amps MCB-01 No backlite base neutral link and 01 no earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs including fixing arrangement complete all as specified and directed.
S & F for steel tubular swaged poles complete with cast iron base plate , final taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 meters long) complete with CI base plate all as specified and directed.
S & F for MCCBs 415 volts , 16KA, 4 pole 63 Amps fixed with suitable panel box with locking arangement , incoming and out going are fix by proper lugs complete all as specified and directed.
M&L for cement concrete 1:2:4 Type B2 (using 40mm graded aggregate) as in foundation all as specified and directed.
M&L for cement concrete 1:2:4 Type B1 (using 20mm graded aggregate) as in foundation/coping all as specified and directed.
S & F for DWC (Double wall corrugated) HDPE pipes , ISI marked IS 14390 Part-II of outer dia 55mm and inner dia 38mm with smooth internal and profied external surface for non pressure under ground cable including all connted accessories like 'O' ring etc for protection of cable complete all as specified and as directed.
M&L for Point wiring with casing and capping controlled by one switch with 1.50 Sqmm (nominal area) FRLSH, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable and FRLSH, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, with all fittings, ISI marked and complete all as specified and directed.
S&F for ceiling rose, bakelite, surface type, 220/ 240 Volts, three terminals complete all as specified and directed.
S&F for MCB, SPN 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed.
S&F for MCB, SPN 6 to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed.
S&F sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed.
Description all as per item No. 61.00 herein before, but for One socket out let 5/ 6 Amps point on the same board
S & F for ceiling fan complete with electronic regulator and three blades, down rod, accessories 230V, 1200mm sweep BEE 5 star rated complete all as specified and as directed.
S&F for LED light fitting 1x20 Watts 240 volts AC decorative box type with driver, holder including LED tube light connecting of with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M&L for sub main wiring with 2 run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. Note : (i) Two run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
Kakolil Trade Agencies
M/s S A Traders
ASHOK BISWAS
City Constructie Pvt Ltd
Sree Tirumala Enterprises
SUMAN
Binod Hawlader
GAYATRI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .