| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance OPP INDUSTRIAL ESTATE DIGIANA JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | Admitted-Finance |
| 2 | Admitted-Finance INDUSTRIAL ESTATE DIGIANA JAMMU | Admitted-Finance |
| 3 | Admitted-Finance BHAGWATI NAGAR JAMMU | Admitted-Finance |
| 4 | Rejected-Technical NOT AVAILABLE | Rejected-Technical CDR and treasury receipt not attached |
Tender Value
₹3.8 L
EMD Value
₹7,600
Closing Date
22 Oct 2022, 2:00 pmClosed
Executive Engineer Tube Well Irrigation Divi Jammu
Executive Engineer Tube Well Irrigation Divi Jammu
Providing Fitting Replacement of Existing machinery with allied works at Tube Well G.S Pura A1
2022_IFC_188876_1
eNit No. 15 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹300
Executive Engineer Tube Well Irrigation Divi Jammu
₹7,600
9 Mar 2023
19 Sept 2022
25 Oct 2022
19 Sept 2022
22 Oct 2022
19 Sept 2022
Amount
Providing, Lowering, Installation, Testing & Commissioning of Submersible Pump set at tube well mentioned above having capacity of (15,000 GPH) x (40m Head) coupled with 3 phase 380 volts+10%, 50 HZ+3% AC supply, copper wound squirrel cage induction submersible motor 20HP along with 2 No 100 mm flanged column pipes for further lowering the existing flanged column pipes assembly and other allied materials/equipments required during lowering of submersible pump set. The job also includes painting of existing column pipes with black paint of required quantity The job also includes P/L of 25 mtr-35 mm sq. 3.5 core aluminum cable armored cable for connection of control panel to electric transformer and 80 mtr-10 mm sq 3 core submersible cable for connection of panel to the submersible pump set. The job also includes providing and fitting of 200 Amp, main switch with HRC Fuse of reputed make. The job includes cost of material, labour, carriage, tools and tackles ( complete job in all respects) Electro-mechanical accessories used should be of genuine/reputed make conforming to latest IS code.
Design, fabrication, installation, testing and commissioning of Automatic control panel with built in fault analyzer suitable for running 20 HP submersible pump set. The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet and provision for fixing it on the wall or the ground with the help of anchoring bolts should be made. The Panel should be sturdy enough for vibration free operation and should be equipped with suitable locking / sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel is to be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: - 1. The panel should be fitted with 100 Amps MCCB and a set of RYB indicators at incoming side. 2. Star delta starter: - The panel should be fitted with 01 No star delta starter comprising of 1 No. 50 Amps contactor for main and 1 no. contactor 50 Amps. for delta supply and 1 No. Air break contactor 50 Amps. for star operation, 1 no. timer for changing over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor. 1 No. MCB 2 Amps. for the protection of internal control wiring. A neat and clean internal control wiring should be made with flexible, copper cables to complete the star delta circuit of outgoing supply. 3. Protection device: - The panel is fitted with protection devices like relay, CT/PT, timer, fault analyzer with capacity to protect motor by isolating the power supply of motor de-energizing the starter/ panel from electro-mechanical faults which may otherwise damage the motor windings like phasing, under voltage, over voltage, unbalanced voltage, reverse phasing, over current / load, dry running, unbalanced current / load, earth leakage, short circuiting, locked motor, broken shaft. It should also display current of RYB phase and also line voltage of RY an YB phase and record trip counts and indicate trip status for over load, under load, single phase, unbalanced phase, earth fault, over voltage, under voltage, under voltage / reverse phasing respectively. i) Voltage related faults: - Single phasing, under voltage, over-voltage, unbalanced voltage. ii) Current Related faults: - Over current / load, dry running, unbalanced current / load, earth leakage, short circuiting. The panel shall also be provided with ammeter and voltmeter of appropriate capacity. All the equipments used i.e. contactors, relays, MCCB etc. used should be of standard make.
M/S V.N ENGG WORKS
AJAY ELECTRIC AND MECH WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .