Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING THE L1 BIDDER | |
| 2 | L2₹54.5 L+₹18.5 L (51.3%)Rejected-AOC | L2 | Rejected-AOC REJECTED FOR NOT BEING THE L1 BIDDER |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
21 Dec 2023, 6:00 pmClosed
GE
GE (I) CAMPBELL BAY, ARMY LAND, CAMPBELL BAY, GREAT NICOBAR-744302
PROVN OF WORKSHOP SHED AND ALLIED WORKS AT CG LAND NEAR JETTY, KAMORTA UNDER GE(I) CAMPBELL BAY
2023_MES_626549_1
8095/E8
Open Tender
Civil Works
Item Rate
180 days
CAMPBELL BAY
PLEASE REFER TENDER DOCUMENT AND NIT
8 documents required · 8 mandatory
₹500
GE (I) CAMPBELL BAY
₹74,000
Yes
23 Feb 2024
3 Nov 2023
23 Dec 2023
3 Nov 2023
21 Dec 2023
27 Nov 2023
Amount
B/R PORTION Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in any kind of soil depth complete all as specified and as directed.
Removing excavated material (soil) to a distance exc 250 mtr but n.exc 500 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed
M & L for providing cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in CM (1:4) complete all as specified and as directed.
M & L for 15 mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and as directed.
M & L for preparing new plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed.
M & L for rendering 10mm thick in CM (1:6) on fair faces of solid block or concrete surfaces and finishing fair and even without using extra cement complete all as specified and as directed.
M & L for preparing new plastered surfaces of wall and applying two coats of dry distemper on decorated wall surfaces of any description complete all as specified and as directed.
M & L for preparing new plastered surfaces of wall and applying two coats of anti fungal interior surface of column, acrylic emulsion on wall surfaces of any description complete all as specified and as directed.
S & F pre-painted corrugated galvalume (55% aluminium + 43.5% Zinc + 1.5% Silicon) steel sheets as in roofing/ wall cladding, 0.50mm thick (total coated thickness) confirming to AS 1397/ ASTM A-792 and having yield strength minimum 550 Mpa fixed with self drilling metal coated screw of appropriate size, self taping bolts complete all as fixed as per manufacturer's instruction and as directed. Note : The sheet shall be laid with one corrugation side lap and one end lap minimum 150mm all as per manufacturer's instructions alongwith wind ties.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as fixed as per manufacturer's instruction and as directed.
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n.exc 30cm long with dia of neck 16 to 20 mm complete all as specified and as directed.
S & F for roof trusses (framed), trussed, purlins, crane grantries, rail and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including bracket etc confirming to Fe 410-W (Gde-E-250) quality complete all as specified and as directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (any shade) over a coat of red oxide zinc chrome primer all as specified and directed.
M & L for painting on new steel surfaces n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M & L for hardcore of guage n.exc 63mm, deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface all as specified and as directed.
M & L for providing 100mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in flooring complete all as specified and as directed.
M & L for coloured chequered cement concrete tiles of size 300mm x 300mm x 25mm thick, set in floors etc, laid over and including 20mm thick screed bed in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M & L for providing cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in flooring and rounded or chamfered on edges complete all as specified and as directed.
M & L for glass dividing strips 22mm width of strip plastic dividing strip 1.5mm thick for flooring complete all as specified and as directed.
S & F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing hinges, tower bolts, handle etc complete all as specified and as directed.
S & F for anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and as directed.
S & F for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No). hinges type B-21 100mm long (2 Nos) suitable handle (1 No) complete all as specified and as directed.
S & F for 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S & F for stainless steel butt hinges 100mm long, medium weight cold rolled fixed to timber frame work for doors complete all as specified and as directed.
S & F for stainless steel butt hinges 75mm long, medium weight cold rolled fixed to timber frame work for doors complete all as specified and as directed.
S & F for extruded aluminium alloy handles 150mm size, fabricated type anodised complete all as specified and as directed.
S & F for aluminium anodized barrel tower bolt of extruded section length of bolt 150mm complete all as specified and as directed.
S & F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and as directed.
M & L for use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for rough finished surfaces of concrete flat all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia confirming complete all as specified and as directed.
Description all as per Item No 32 above but 6 to 8mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
M & L for RCC (Design Mix M-30) as in beams, cantilevers, bressummers, lintels over 1.5m span etc., complete all as specified and as directed.
S & F for letter writing sign board (capital letter writing more than 10'') for stainless steel using marking places complete all as specified and as directed.
E/M PORTION M & L for Point wiring with 1.5 Sqmm single core copper conductor FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid FRLS PVC casing capping/PVC conduit and its accessories of suitable size, heavy grade ISI marked surface on walls /roof and MS pressed pvc terminal boxes of 1.6 mm thick of suitable size including fixing provision of cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sqmm multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for One light point controlled by one, one way switch 5 Amps complete all as specified and as directed.
Description all as per Item No 36 above but One fan/exhaust point controlled by one switch and regulator complete all as specified and as directed.
Description all as per Item No 36 above but One socket 5 Amps on same board complete all as specified and as directed.
Description all as per Item No 36 above but One socket 5 Amps on independent board complete all as specified and as directed.
Description all as per Item No 36 above but with 4 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S & F switch piano single pole flush type 5 Amps, 230 volts complete all as specified and as directed.
S & F Switch Socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed.
S & F Switch Socket combination 2 in 1, 3 pin, 15 Amp flush type universal complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
S & F surface mounting 20 W LED tube light box type fitting nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70, a colour temperature of 6500K and CRI>83, pre wired connection up to tube light fitting with connecting up with copper 2 core flexible cord of minimum size 1.0 Sqmm and white in colour and shall meet IP20 rating with THD < 10% and PF > 0.95, total power consumption should not exceed 20W (including driver) including round block complete all as specified and as directed. Make : Philips/ Jaquar/ Havells
S & F energy saving ceiling fan 1200 mm sweep with double ball bearing in opal white color and BEE 5 star rated (BLDC) complete including provision of 2 core copper wire connected from ceiling rose to fan and marking MES No in black paint complete all as specified and as directed.
S & F Exhaust fans including louvers AC single phase 240 volts of size 300 mm sweep (Metal body) and minimum 1350 RPM including flexible wire 3 core 1.5 Sqmm from exhaust fan to ceiling rose all as specified and as directed. Note :- (i) The cost of making hole in walls /other surfaces & making good the disturbed surfaces incl any framework /cement work /wood work /welding work etc., required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.
S & F Sheet metal enclosure for DB’s TPN 415V, 4 way with 200 Amps rated bus bar CRCA Sheet steel, RAL 9003, power coated IP 43 metal door complete all as specified and as directed. Make : L&T/ Legrand/ Havells
S & F sheet metal enclosure for SPN DB’s double door 240V, 8 way with 200 Amps rated bus bar CRCA Sheet steel, RAL 9003, power coated IP 43 metal door complete all as specified and as directed. Make : L&T/Legrand/ Havells
S & F MCB SP 6 to 32 Amps with breaking capacity 10 KA "C" Series complete all as specified and as directed. Make : L&T/ Legrand/ Havells
S & F MCB SPN 32 Amps with breaking capacity 10 KA "C" Series complete all as specified and as directed. Make: L&T/Legrand/ Havells
S & F MCB SPN 40-63 Amps with breaking capacity 10 KA "C" Series complete all as specified and as directed. Make : L&T/ Legrand/ Havells
S & F MCB TPN 40 to 100 Amps with breaking capacity 10 KA "C" Series complete all as specified and as directed. Make: L&T/ Legrand/ Havells
M & L for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire complete all as specified and as directed. Note : (i) 3 Runs of 6 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
S & F energy saving new generation 10 watts LED bulk head fitting IP 66 luminaire with opal diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.
M & L for Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth of not less than 2.25mtr below ground level than 1.5mtr below ground level connected to GI earth wire 4mm dia by means of bolts washers etc made out of GI earth wire will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type C1 (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as shown in electric plate No.3 of MES Sch Part-I., and as directed by Engineer-in-Charge. Note : (i) Earth work & PCC are deemed to be included in the quoted rate. (ii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost
Supply and laying XLPE, insulated, armoured, heavy duty, electric cable with stranded aluminium conductors, 1100 volts grade of cross sectional area 3.5 Core x 35 Sqmm, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed. Make : Havells/ Polycab/ Finolex
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed. Make : Gemini / Telerex/ Prince
M/S Sudhir Kumar Gupta
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .