Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC | ₹1.6 Cr | 1 | Accepted-AOC LOWEST |
| 2 | 2₹1.8 Cr+₹20.2 L (13.0%)Rejected-Finance 422 MAIN BRANCH MASTER TARA SINGH NAGAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | ₹1.8 Cr+₹20.2 L (13.0%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹1.8 Cr+₹21.3 L (13.7%)Rejected-Finance | ₹1.8 Cr+₹21.3 L (13.7%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹1.9 Cr+₹29.5 L (19.0%)Rejected-Finance DH 101 DEEN DAYAL NAGAR MAHARAJPUR GWALIOR 474020 MP | GWALIOR | MADHYA PRADESH | 474020 | ₹1.9 Cr+₹29.5 L (19.0%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹1.9 Cr+₹32.2 L (20.7%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | ₹1.9 Cr+₹32.2 L (20.7%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
8 Apr 2023, 6:00 pmClosed
CWE AF GWALIOR
CWE AF GWALIOR
PROVISION OF INFRASTRUCTURE FOR SOFTWARE SUPPORT LAB (SSL) FOR D-29 SYSTEM AT EWR AT AF STN GWALIOR
2022_MES_533906_4
85015/E8
Open Tender
Civil Works
Lump-sum
365 days
Gwalior
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) TECH AREA GWALIOR
₹2.1 L
Yes
19 May 2023
11 Mar 2023
11 Apr 2023
11 Mar 2023
8 Apr 2023
25 Mar 2023
Amount
SCHEDULE A PART -I (BUILDING WORKS)
Construction of Soft Ware Suuport Lab( SSL) Bldg in Single storey complete all as specified and shown in drawings.
Sch A Part- II (GHE/GSE SHED)
Lump sum price worked out by the contractor for "GHE/GSE Shed" as listed in Sch ‘A’ Part II.
Sch A Part- III (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for "Internal Water Supply" as listed in Sch ‘A’ Part III.
Sch A Part -IV (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in SCHEDULE ‘A’ PART- IV .
Sch A Part -V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Sch ‘A’ Part- V .
Sch A Part- VI(ROAD,PATH &CULVERT)
Lump sum price worked out by the contractor for "ROAD,PATH & CULVERT", as listed in Sch ‘A’ Part-VI.
Sch A Part -VII (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL",as listed in Sch ‘A’ Part- VII.
Sch A Part -VIII (AREA DRAINAGE)
Lump sum price worked out by the contractor for "AREA DRAINAGE,as listed in Sch ‘A’ Part- VIII.
Sch A Part -IX (SECURITY WALL,FENCING & GATE)
Lump sum price worked out by the contractor for "SECURITY WALL,FENCING & GATE",as listed in Sch ‘A’ Part- IX.
Sch A Part -X (EXTERNAL WATER SUPPLY),
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY",as listed in Sch ‘A’ Part- X.
Sch A Part -XI (CABLE DUCT))
Lump sum price worked out by the contractor for "CABLE DUCT)",as listed in Sch ‘A’ Part- XI.
Sch A Part- XII (LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for "LIGHTENING PROTECTION" as listed in Sch ‘A’ Part -XII
Sch A Part -XIII ( CHILLER UNIT)
Lump sum price worked out by the contractor for " CHILLER UNITS",as listed in Sch ‘A’ Part- XIII .
Sch A Part -XIV ( SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for "SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK",as listed in Sch ‘A’ Part- XIV .
Sch A Part - XV (Miscellaneous Items of B & R and E & M)
S & F powder coated anodised aluminium partition frame of size 101.6mmX44.5mmx3mm on top and bottom and middle rail, vertical rail 101.6mmx44.5mm x 3mm thick, standard channel at bottom 40mmx20mmx3mm and clip for fixing glass etc and partly/fully fixed with 12mm thick prelaminated particle board & 5.5 mm thick glass fixed with aluminium snap beading over and including all necessary fittings of approved make all as specified and as directed by GE.
M&L for Construction of Septic Tank for 50 users including necessary earth work in excavation in soft/loose soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brickwork with using sub class "A" class bricks cement mortar 1:4 , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast manhole cover slab having 8 mm dia TMT bar reinforcement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab, 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber, formwork to sides and soffits, 150 mm dia SGSW inlet & outlet pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawing No.TD-217 sheet1/2 & 2/2 and as specified.
M&L for Construction of Soakage well for 1.80 m dia (internal dia) & 3.0 m effective depth including necessary excavation in earth work in soft/loose soil, plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate ) as in foundation , brickwork using sub class "A" bricks in cement mortar 1:4 in walls & honeycombed brick wall, reinforced cement concrete M-25 (design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced , plain cement concrete band and dwarf wall, formwork to sides and soffits of RCC slab & filling with brick bats loose filling & PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) including intercepting chamber & screen chamber with brickwork in cement mortar 1:4 complete all as specified and shown in drawing No.TD-576 sheet1/2&2/2 and as specified.
M&L for construction of PCC solid block masonary wall valve pit of size 900mm x 900mm x 900mm (inner dimension) of necessary earth work excavation, 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, PCC block wall build in cement mortar 1:6, rendering 15 mm thick with cement mortar 1:6 externally up to 15 cm below ground level and cement mortar 1:4 internally and providing MS sheet cover 3.0 mm thick and angle iron (size 40 mm x 40 mm 5 mm) frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and welded with hinges including necessary locking arrangement & 50mm lock (pad lock brass 6 levers with key in duplicate) and complete all as specified and directed. Note: 1. Necessary earthwork shall be meausred and paid separately. 2. The top edge/level of valve chamber shall be 15 cm above ground level.
M&L for construction of PCC solid block masonary wall valve pit of size 600mm x 600mm x 600mm (inner dimension) of necessary earth work excavation, 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, PCC block wall build in cement mortar 1:6, rendering 15 mm thick with cement mortar 1:6 externally up to 15 cm below ground level and cement mortar 1:4 internally and providing MS sheet cover 3.0 mm thick and angle iron (size 40 mm x 40 mm 5 mm) frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and welded with hings including necessary locking arrangement & 50mm lock (pad lock brass 6 levers with key in duplicate) and complete all as specified and directed. Note: 1. Necessary earth work shall be meausred and paid separately. 2. The top edge/level of valve chamber shall be 15 cm above ground level.
Supply and fix double wall corrugated (DWC) HDPE pipe 50mm OD for protection of LT/HT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
Supply and fix double wall corrugated (DWC) HDPE pipe 90mm OD for protection of LT/HT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
M&L for cutting CI/DI pipe 80 mm dia and fixing fittings complete all as directed. Note: The CI/DI fittings like tee/bend etc if any shall be measured and paid as supply and fix under relevant item of this schedule.
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with & including provision of HDPE pipe of 150 mm bore sutable for 0.4 Mpa working pressure complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/taxi track / apron /floors etc.
Supply, install, test and commissioning of UPS, 5 KVA, single phase, AC input voltage range 160 V to 260 V and output 230V +/- 1% with suitable capacity battery bank unit for 60 min back-up including all connecting accessories of copper connectors/thimbles etc all as directed and specified by Eng-in-Charge.
Supply and fix SFC (Static frequency converter) with input 3 pahse, 415V, 10 KVA, 50 hz and output voltage 3 phase, 115 Volts (P-N) & 200 Volts (P-P), 400 Hz with output at 1% tolerance for 3 phase four wire system, programmable controller for output voltage and frequency adjustment with password protection and in-built overload protection with battery bank suitable for 60 min back-up along with necessary copper connectors for batteries complete installation and testing on completion all as directed and specified by Eng-in-Charge. NOTE: PERFORMANCE FEATURE:- (i) DSP controlled IGBT based PWM technology. (ii) Inbuilt isolation Transformer at line input. (iii) On line battery testing facility (iv) Operating temperature 0 to 45 degree C (v) Relative humidity 95% RH Non condensing (vi) Enclosure protection IP 20 (IP 21 Tto IP 54 optional)
Supply, Install, Testing & commissioning Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled, outdoor type & designed for input variation between 170 V to 280 V (each phase)/300V-480V (3 phase) with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 volts / sec, efficiency-95% for ambient working temperature 0 - 50 degree celcius max/relative humidity 90%, of capacity 75 kVA complete all as speicified and directed alongwith the following features. (i) Regulator for sensing circuit to maintain constant output voltage even on DG (ii) Output voltage protection, Adjustable output under and over volt. (iii) Controls : Auto- Manual switch & lower/rise switch (iv) Servo Motor Protection : Voltage cut-off servo motor at input and over voltage std upto 20 kVA (v) Surge protection device 8/20 micro sec as per IEC-61000-4-4/61000-4-5 (vi) change over/stabilizer Bypass switch
Supply, install, commissioning and testing of split type, air conditioner of capacity 2.0 TR (6000 K Cal/hr), dual mode (Hot & Cool), single phase, (Non CFC/HCHC) suitable for 230 Volt +/- 10% , 50 Hz, AC supply complete with cordless remote control unit with in-built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Outdoor unit comprising of one No. Compressor of 2.0 TR capacity with compressor motor, condenser fan motor of appropriate capacity 01 No. air cooled condenser of 2.0 TR capacity -01 No. shall be installed at outside of the building (c) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacturer's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2.0 TR AC complete all as specified and directed.
Item no. 15.14 contdd.. (f) Electrical cable required to connect outdoor unit and indoor unit to voltage stablizer inclusive in above rate. Note :- (i) Cutting of holes in walls/window of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by the contractor shall be deemed to be inclusive of this aspect. (ii) All other connected civil works & other miscellaneous works required for installation of split AC & proper functioning as directed by Engr-in-Charge shall be inclusive in quoted rate. (iii) Additional length of copper tubes for compressor inlet/outlet with insulating material, casing/capping shall be inclusive in unit rate.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 3 star rating complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Outdoor unit comprising of one No. Compressor of 1.5 TR capacity with compressor motor, condenser fan motor of appropriate capacity 01 No. air cooled condenser of 1.5 TR capacity -01 No. shall be installed at outside of the building. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed.
Item no. 15.16 contdd.. (f) Electrical cable required to connect outdoor unit and indoor unit to voltage stablizer inclusive in above rate. Note :- (i) Cutting of holes in walls/window of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by the contractor shall be deemed to be inclusive of this aspect. (ii) All other connected civil works & other miscellaneous works required for installation of split AC & proper functioning as directed by Engr-in-Charge shall be inclusive in quoted rate. (iii) Additional length of copper tubes for compressor inlet/outlet with insulating material, casing/capping shall be inclusive in unit rate.
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed.
Supply and fixing PVC nylon braided industrial quality drain pipe of 20mm inner bore including fixing accessories on wall/roof etc all as directed
Supply,install, testing and commissioning of descicant type dehumidifier of 1200 CFM and electric regenerating, portable type, continuous operating with proper mounting arrangement including wall mounting/ ceiling suspended/ table mounted with necessary fitting and fixtures complete with standard controls with saftey controls and DIGITAL display unit all as directed. Ducting work with PVC/ Flexible hose for process and regeneration air inlet and outlets etc. The dehumidifier includes following features:- (i) Dehumidifier MOC with GI sheet PP powder coated (anti corrosive paint) both inside & outside with single skin construction. (ii) Air circulation type ; 100% (iii) Process air filters: mesh filters. (iv) Reactivation filters : mesh filters
Design, fabricate, supply, install, testing and commissioning refrigerant based cooling air supply system for effective cooling of labaratory tesing equipments for Rack -1 and Rack -2 as sepcified below. (a) Rack -1 : chilled air flow @ 50 kg/hr at 5 deg.Centigrade (b) Rack -1 : chilled air flow @ 225 kg/hr at 5 deg.Centigrade. Note: 1. The contractor/vendor shall submitt detailed design specifications/layout plan & drawings of chilled air system for approval of Accepting Officer before commencement of work. 2. The item rate is inclusive of any modifications suggested in design of blower/ducting system as techincally necessary for functional requirement.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 4mm as earthing lead by means of GI bolts nuts check nuts and washers of galvanised iron or steel all as shown in electric plate No 5 SSR Part-I, connected to earthing etc all as specified including testing on completion with all necessary excavation in any kind of strata, earth work, PCC earth Pit in 1:3:6 CI RCC cover, CI funnel, GI watering Pipe 20 mm complete. Note :- The length of the galvanised strip beyond 7.5m will be measured and paid seperately. (ii) All joints of galvanised strips shall be of brass only. (iii) Test rresult of earthing to be submitted by the contractor for all earthing. (iv) Earth result of the pit shall be less than 1 Ohms, during the maintenance period also to be maitained earth resistance less than 1 Ohms falling which new earthing to be provided by the contractor with out any extra cost. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) using 20mm grade stone masonery of size 200mmX200mmX250mm including necessary earth work. (vi) the rate quoted by the contractor shall also be deemed to be including (a) Testing submission of earth result as desired. (b) Excavation upto 5 mtrs depth and returning filling in any type of soil complete all as specified and directed by Engr-in-Charge.
Material & Labour for sub main wiring, concealed, using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of 1100 Volts grade drawn in and including PVC rigid conduit medium grade of size not less than 25 mm dia with standard accessories fixed on walls / ceiling surface etc along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete. Note:- Two runs of submain wire 4.0 Sqmm + one run earth wire 4.0 sqmm + one run PVC conduit shall be measure as one unit.
Material & Labour for sub main wiring, concealed, using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of 1100 Volts grade drawn in and including PVC rigid conduit medium grade of size not less than 25 mm dia with standard accessories fixed on walls / ceiling surface etc along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor complete. Note:- Two runs of submain wire 6.0 Sqmm + one run earth wire 6.0 sqmm + one run PVC conduit shall be measure as one unit.
S&F MCB SPN 10-40 amp, rupturing capacity 10 kA, series 'C' complete all as specified and directed by Engr-in-Charge.
S&F MCB SP 40 amp, rupturing capacity 10 kA, series 'C' complete all as specified and directed by Engr-in-Charge.
S&F MCB MCB TPN, 4 pole, 415 volt, 63 amp, rupturing capacity 10 kA,, series 'C' complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below ground level connected to and including galvanised earth lead wire 4mm dia as earthing lead by means of GI bolts nuts check nuts and washers of galvanised iron or steel all as shown in electric plate No 5 SSR Part-I, connected to earthing etc all as specified including testing on completion with all necessary excavation in any kind of strata, earth work, PCC earth Pit in 1:3:6 CI RCC cover, CI funnel, GI watering Pipe 20 mm complete. Note :- The length of the galvanised strip beyond 7.5m will be measured and paid seperately. (ii) All joints of galvanised strips shall be of brass only. (iii) Test rresult of earthing to be submitted by the contractor for all earthing. (iv) Earth result of the pit shall be less than 1 Ohms, during the maintenance period also to be maitained earth resistance less than 1 Ohms falling which new earthing to be provided by the contractor with out any extra cost. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) using 20mm grade stone masonery of size 200mmX200mmX250mm including necessary earth work. (vi) the rate quoted by the contractor shall also be deemed to be including (a) Testing submission of earth result as desired. (b) Excavation upto 5 mtrs depth and returning filling in any type of soil complete all as specified and directed by Engr-in-Charge.
Supplying and fixing stout plus LED batten 40 W including all accessories prewired and connecting the same to ceiling rose with and including 3 core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement to wall/ceiling complete all as specified and directed.
Supplying and fixing intregal LED street light fitting, 30 W with pressure diacast alluminum housing IP-66 with mounting bracket including all accessories prewired and connecting the same to electric source with and including 3 core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement to wall/elctric pole complete all as specified and directed.
S&F sheet metal enclosure for DB’s when MCBs to be used Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of 20 Amps 230 Volts ,1 0 KA "C" series complete all as specified and directed
Supply and installation of waterless and maintenance free Earthing (grounding) elctrode of size Dia 100 mm x Length 3000 mm with 17 mm u bounded MS Conductor in Pre cast in high purity electrically conductive granular (Marconite), having ultra low resistivity of 0.001 Ohm - m. (Provide the resitivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre cast or backfill the voids surrounding the metal conductor in anugured bore hole of 100 mm dia x 3000 mm depth, resulting in increase of effective surface area of the earth electrode and in case of high soil resistivity agrid or multiple elctrodes to be installed to lower the desired earth resistance value, permanently with no further maintenance or periodic watering or recharge during it's life f over 50 years in all type of soil invluding dry or rocky soils. Earth enhancing material should not leach into the adjacent soil or surrounding water channels and it's Ph should be in natural range. Earth enhancing material should permanently protect the encased metal conducto or corrosion. Electrodes's top terminal should be sealed permanently with the conductive concrete and extension strip taken out be terminated at earth bus bar.Other hardware like nuts, bolts and washers should be of stainless steel. Electrode should withstand fault current up to 30 kA for 1 sencod. (Bidder provide the certificate for the same). Supplier of the Marconite Earthing Material should provide authorization letter from the Manufacturer for the Genuine material and also furish certifications as per IEC 62516-7 & resistivity certificate conforming 0.001 ohm.
HARI CONSTRUCTION CO.
M/s Kohli Builders
M/s Bijender Singh
RAVINDRA SALES
JEE JEE BUILDERS
M/s Raghav Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .