Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Accepted being lowest on 08 Jul 2020 | |
| 2 | L2₹4.8 L+₹71,975 (17.9%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-Finance Rejected |
Tender Value
₹5.0 L
EMD Value
₹9,900
Closing Date
1 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
GE Faridkot-151203 Punjab
Balance work of Provn of 10XSecurity lights in wksp coy (Arty) area and certain other (E/M) Revenue and Minor works under Risk and Cost at Faridkot Mil Stn
2020_MES_349586_1
GE FRD-76/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Faridkot Mil Stn
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹9,900
Yes
14 Aug 2020
3 Jun 2020
3 Jul 2020
3 Jun 2020
1 Jul 2020
17 Jun 2020
60 days
Amount
Supplying, laying, jointing and testing and commissioning of cross sectional area 16 sqmm, 2 core XLPE insulated screened PVC bedded galvanised steel strip wire, armoured electric cable heavy duty multi stranded aluminium conductor PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
Supply and fixing GI pipe 15 mm bore light grade ISI marked for protection of cable laid under the road / laid under the floor / fixed to wall/pole or in trenches with suitable GI clamps complete all as specified and directred by Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing cross arms, bracings, stiffeners, supports, clamps and back plates clamps fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
S&F of air termination rod 12 mm dia single pointed 300 mm long along with base plate welded at bottom of termination rod,of size 10 cm long fabricated out 25x3 mm thick aluminium strip along with making 9 mm dia for fixing in fastners (wooden block) complete all as specified and directed by Engineer -in-Charge.
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M&L for test points as per IS specifications of shape and size as approved by GE and Engineer-in-Charge, made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
M&L for aluminium strip 25mmx3.15mm complete with seddles and fixing screws etc for roof condutors and down conductors above ground complete all as specified and directed by Engineer -in-Charge.
M & L for PCC Block of size 25 cm x 25cmx30cm height in PCC (1:2:4) type B-1 using 20mm graded stone aggregate providing 02 Nos. MS fastner at the top of the block by using 8/9mm dia 20cm long bolts with T junction of 10cm & embeded in the PCC block, keep 7 cm portion of the bolt above the upper surface of PCC block alongwith 02 Nos washers and nuts etc complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position.
S&F wooden block of locally available hard wood of size 25 x 10 x 5cm for mounted on top of PCC block for errection of air termination alongwith bolts and nuts and run the roof conductor complete all as specified and directed by Engineer in Charge.
Supply and fix porcelain insulator of size 15cm x 7.5cmx5.7cm for isolation of conductor from the building wall by provviding 15cm long fastner at every 16cm distance in the wall complete all as specified and directed by Engineer-in-Charge.
Supply and fix GI pipe 40 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core drawing through concealed conduit terminated with steel pressed sunken terminal boxes and 1.5 sqmm PVC stranded copper conductor insulated unseathed stranded (Green colour) connected to common earth point dolly for One fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core drawing through concealed conduit terminated with steel pressed sunken terminal boxes and 1.5 sqmm PVC stranded copper conductor insulated unseathed stranded (Green colour) connected to common earth point dolly for One fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
S&F in replacement switch piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement Ceiling rose, two to three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer in Charge.
S&F 15mm dia stop valve cast copper alloy chromium plated, with long shank & cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for cold water application complete all as specified & directed by Engineer-in-charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for Hot water application complete all as specified & directed by Engineer-in-charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted TP & N 4 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in-Charge.
Supply and laying mild steel water tubing medium grade galvanised of size 25mm bore with all fittings and laid in trenches under floor/ road or on wall complete all as specified and directed by Engineer-in-charge
S&F MCB single Pole 240 Volts 6 to 32 Amp complete all as specified and directed by Engineer in Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated multistranded unsheathed copper conductor cable drawn in and including PVC casing caping with all accessories such as bend galvanised steel terminal boxes and making good the disturbed surface with all jointing accessories including provision of pressed steel sunken terminal boxes 60mm deep, suitable length and 1.2mm thick painted with red oxide primer for mounting switches, sockets, covered with including 2.8mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated solid copper conductor wire as earth continuity to common earth and connecting to earth dolly for one switch socket combination 5 Pin 5 Amps 230 volts point controlled by one switch and wiring with 1.5sqmm PVC unsheathed copper conductor cable 1.5sqmm PVC insulated earth wire on independent board complete all as specified and directed by Engineer-in-Charge.
S&F socket two in one ,3 Pin 5 Amps 230 VAC supply complete all as specified and directed by Engineer in Charge.
Supply and laying mild steel water tubing medium grade galvanised of size 15mm bore with all fittings and laid in trenches under floor/ road or on wall complete all as specified and directed by Engineer-in-charge
S&F 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipes complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLS stranded copper conductor drawn into PVC concealed conduit, including one run 4 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 4 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge.
Supplying and fixing mild steel framed work for desert cooler stand made with angle iron of size 40x40x5mm cross bracings, stiffeners, supports, clamps and back plates clamps fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge.
Supply & fix of gun metal globe or gate valve 15mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 4 sqmm twin core , 1100 volts grade heavy duty cable, PVC insulated aluminium multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connections of street light fittings with overhead lines/UG Cablecomplete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
DEEPAK ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .