Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
30 Nov 2020, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
SPL REPAIRS TO Servant Qtrs OF P21 P22 ADDITION ALTERATION TO ANNEXE AT AIR HANGER AT MILIT GIRINAGAR PUNE
2020_MES_391758_1
GE I R AND D TOKEN 08 2020 21
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE I R AND D GIRINAGAR PUNE 411025
₹94,000
Yes
1 Dec 2020
2 Nov 2020
1 Dec 2020
2 Nov 2020
30 Nov 2020
15 Nov 2020
2 Nov 2020 - 9 Nov 2020
60 days
Amount
PART-I B/R PORTION (SPL REPARIS TO QTR NO P-21 & P-22) Dismantling of single layer manglore tiles roofing including ridges complete all as specified and directed by Engr-in-Charge.
Dismantling the battens of any size incl tiling, Fillets spaced exc. 15cm centre to centre complete.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness including Nainital or Similar pattern roof coverings complete.
S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guide rails, sliding doors, fixed with angle cleats or others connecting plates all as specified and as directed by Engr-in-Charge.
M&L Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, roof fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F Pre-painted coloured galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of an colour having tensile strength of 550Mpa as in roof covering/ridges fixed with self tapping screws all as specified and directed.
M&L for Two Coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10Cm width or girth.
M&L for Preparation of Old painted steel surfaces and applying two coats of synthetic enamel paint complete.
Dismantling wall and ceiling boards of any thickness or any size including cover fillets and frame work complete.
M&L for Powder Coated GI snap grid frame work with size of grid 605x605mm for false ceiling including hangers 6mm dia G.I. (upto 1200mm length) adjusting level fixed to roof slabs,truss and Purlins by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified complete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement builing boards fixed or laid/inserted to timber/GI/aluminium framework with screw in ceiling complete all as specified and directed.
M&L for applying three coats of white wash on ceiling board including preparation of surfaces complete.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including floor finishes complete all as specified and directed.
Roughning surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc. incl removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00Kg/Sqm complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in padding (level course) on roof 40mm thick average.
M&L for Screeding 10mm thick in CM (1:4) using water proofing compound as per manufacturer's instructions over roof and chajjas finished smooth complete all as specified and directed by Engr-in-Charge. Note:- Water proofing compound will be measured and paid separately.
M&L for APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non-oven fabric (weight not less than 150Gms/Sqm) laid over primed surface with bituminous primer confirming to IS-3384 @ 0.3Lit/Sqm as per IS-3384 and finishing with preventive coat with aluminium paint complete.
M&L for rendering 15mm thick in CM 1:4 on floor finished even and smooth without using extra cement with using water proofing compound @ 3% by weight fo cement and priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2 and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2Kg/Sqm including cleaning surfaces as in sunken floor portion complete.
M&L for cement concrete in floor filling 1:5:10 E-2 using 40mm graded stone aggregate for filling in sunken floors including removal of existing treatment complete.
M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in sub base and similar works complete all as specified and directed.
M&L for Non Skid Ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
ditto - as per above but in skirting and over 10mm cement backing in CM 1:4 complete.
M&L for glazed ceramic coloured tiles of size 300x200x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate finished even and smooth without using extra cement as in floors complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40mm graded aggregate as in plinth protection of 75mm thick finishing cement concrete surfaces even and smooth without using extra cement complete.
Demolition of Roofs, floors (other than ground floors), beams, stairceses, landing, chajjas and similar suspended work cement concrete in reinforced (reinforcemnet cut as required to facilitate demotion).
M&L for Precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles including necessary form work complete.
M&L for MS TMT bars 8mm dia cut to length bent to shape required including crancking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia.
M&L for machine cut cudappah stone slab 20-25mm thick over 20mm cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade fo the slab including rubbing and polishing complete.
Roughing to edges of stone slabs one edge.
Demolition of brick work or stone masonary built in cement mortar complete.
M&L for precast cement concrete block masonary with solid blocks of PCC 1:3:6 tyep C1 using 20mm graded stone aggregate, exc. 10cm in width and setting in CM 1:6 complete.
Taking down plastering in cement mortar on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc.
M&L for rendering 15mm thick on stone masonary internal wall surface in CM 1:6 finished even and smooth without using extra cement complete.
M&L for rendering 15mm thick in two layers, 5mm thick using WPC @3% by weight of cement over 10mm thick stone masonary work. Note:- WPC will be measured and paid separately.
M&L for rendering 5mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement.
Supply only integral water proofing compound.
M&L for applying two coats of cement base paint over a coat of primer on wall surfaces inlcuding preparation of new plaster surfaces on walls.
M&L for complete removal of existing treatment and applying two coats of cement base paint over a coat of primer on wall surfaces complete.
M&L for two coats of OBD over a coat of primer including preparation of new surfaces on walls.
M&L for complete removal of existing wall treatment and applying two coats of OBD over a coat of primer including preparing the surcaces.
M&L for preparation of new plaster surface and applying three coasts of white wash to walls all as specified and directed.
M&L for complete removal of existing treatment and applying three coats of white wash on wall surfaces.
M&L for applying three coats of white wash on ceiling including preparation of new plaster surfaces complete.
M&L for complete removal of existing treatment and applying three coats of white wash on ceiling complete.
Demolition of cement concrete in floors and pavings n. exc. 15cm thickness (below or above ground level).
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base.
M&L for Sand cushion for laying of inter locking paver blocks.
M&L for Machine pressed precast concrete interlocking paver block of approved shape and size conforming to IS15658-2006 of 60mm thickness with grey cement and no pigment, M-35 Grade of approved colour and design complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exc. 1.5Sqm each.
M&L for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per manufactureres instructions all as directed by Engr-in-Charge.
M&L for Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S. tube for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the solvent cement, supplying and fixing in the frame at site as per specifications and drawings.
S&F for 75mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin.
S&F 150mm long aluminium anodised handles, cast type.
S&F 150mm long aluminium anodised barrel tower bolt of extruded section.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5Sqm each but n. exc. 4Sqm each.
S&F Pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified.
S&F Pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified.
S&F PCC 1:3:6 type C1 (using 20mm graded aggregate) as in bed blocks etc. incl necessary form work incl weathering, slightly rounded or chamfered angles and throating all as directed.
M&L for PCC 1:3:6 type C-0 (using 12.5mm graded aggregate) as in filling steel frames etc. incl necessary form work complete.
S&F Mild steel flat iron as in hold fast/window grills.
S&F 35mm thick 2nd class hard wood grazed and skelton shutters divided into squares with pain, chamfered or rounded, mitred and rebated sash bars prepared to receive glass, gauge sizes of members of shutters as specified in SSR Pt-I, Section8, clause 8.20 (A).
M&L for 35mm thick Flush shutters with lipping all around of solid core construction with block board core and ply wood face panels commercial type on both side complete.
M&L for galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature width of aperature 1.18mm.
M&L for aluminium alloy anodised sliding door bolt with hasp staple (bolt type) length 300mm fixed.
S&F 75mm long aluminium alloy Hasp & Staple with mild steel hinge pin incl bolt & hinge plate as in CB shutters.
M&L for helical door spring 300mm long mild steel.
S&F 30mm width flap, electrogalvanised continous piano hinges, mild steel, bright finish for CB shutters.
M&L for floor door stopper of aluminium alloy body 150mm overall length of cover plate complete.
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces exceeding 10cm girth or width.
M&L for preparation of old painted wooden surfaces and applying two coats of synthetic enamel paint complete.
M&L for 2nd class hard wood plain fillets, square, rectangular in section wrought screwed with nails area not exceeding 3SqCm.
S&F Steel windwos with side hung shutters on both sides to receive glass on one side and to receive gauge on other side including projecting type hinges with steel handle on both shutters and steel peg stay, complete with glazing bars, dovetailed or welded all as directed by Engr-in-Charge.
M&L for Steel ventilator with top hung shutter including hinges, steel peg stay complete.
M&L for sheet glass ordinary quality 4mm thick fitted with bedding/oil putty n. exc. 0.5Sqm each all as directed by Engr-in-Charge.
M&L for sheet glass ordinary quality 4mm thick fitted with beeding/oil putty n.exc. 0.5Sqm each sheet glass is ground or obscured or frosted, on one side and fixed all as directed by Engr-in-Charge.
M&L for Mild steel frame work such as grills, gramed bars conforming to Fe410-0 or Fe310-0.
S&F in repair vitreous china orrisa pan squatting pattern 580x440mm with integral foot rests including P or S trap, PVC low level flushing cistern 10 ltr capacity complete all as directed by Engr-in-Charge.
S&F 15mm dia 45cm long PVC water connection with PTMT nuts and washers all as directed by Engr-in-Charge.
S&F 15mm dia GI pipe medium grade with all fittings laid in floor or fixed to walls including tacking down old GI tubes.
S&F 20mm dia GI pipe medium grade with all fittings laid in floor or fixed to walls including tacking down old GI tubes.
Taking up or down steel tubing of 20mm dia connections including cleaning for re-fixing and cutting/screwing steel tubing and re-fixing old steel tubing and connections in new or old position (walls, ceiling or floors etc.) all as directed by Engr-in-Charge.
Taking up or down steel tubing of 15mm dia connections including cleaning for re-fixing and cutting/screwing steel tubing and re-fixing old steel tubing and connections in new or old position (walls, ceiling or floors etc.) all as directed by Engr-in-Charge.
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement outlet dia 75mm in repair.
S&F in repair rotational moulded polyethylene water storage tanks 1000ltrs (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and dismantling of existing cement water tanks.
S&F in repair 20mm dia gunmetal globe or gate valves with iron wheel head screwed both ends for iron pipe.
S&F ball brass valves 20mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule.
S&F in repair angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15mm dia complete.
S&F in repair angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15mm dia with long shank and cup (cocealed type) all as specified and directed by Engr-in-charge.
S&F in repair CP Bib taps 15mm dia with crutch or butterfly handle fancy type.
S&F Brass Chromium plated shower rose 100mm size with or without swivel joints, any size with shower arm including fixing to steel pipe or union complete.
Demolition and breaking up drain AC/PVC pipes set in cement mortar 100mm up and below ground level.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 110mm.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 75mm.
S&F PVC (SWR) Pipes single socketed, in any length with rubber ring joints, fixed to wall, bore of the pipe 110mm.
S&F PVC (SWR) Pipes single socketed, in any length with rubber ring joints, fixed to wall, bore of the pipe 75mm.
S&F PVC (SWR) bends any radius 110mm dia with access door.
S&F PVC (SWR) bends any radius 75mm dia with access door.
S&F PVC (SWR) Single 'T' Junction equal or unequal with oval access door bore of the pipe 110mm.
S&F PVC (SWR) Single 'T' Junction equal or unequal with oval access door bore of the pipe 75mm.
S&F PVC (SWR) Vent Cowl of 110 mm dia .
S&F PVC (SWR) Vent Cowl of 75mm dia .
M&L for 18mm thick prelaminated particle board, interior grade, prelaminated one side decorative face & other side white.
S&F 2nd class hard wood, plain, solid, straight chowkhats frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc. complete all as specified & directed.
Wash hand basin, vitrous china, coloured flat back of size 550 x 400mm encluding cutting for and pining in ends of brackets or erecting stand including 32mm dia PTMTwaste coupling, waste pipe, 15mm dia bore pillar taps, cast copper alloy chromium plated fancy type fixed complete.
Raking out joints/pointing to random rubble or polygonal rubble uncoursed or brought upto couses stone work built in cement or cement lime mortar including necessary scaffolding complete all as directed by Engr-in-Charge.
Flush pointing in CM 1:4 to random rubble or polygonal rubble uncoused stone masonary wall including preparation of surface including necessary scaffolding arrangement complete all as directed by Engr-in-Charge.
PART - II B/R PORTION (ADDN/ALTN TO ANNEXE AT AIR HANGER) Excavation in trenches not exc.1.5 mtr in depth,1.5 mtr in width for foundation of walls,manholes,etc. And getting out in hard/dense soil.
M&L for PCC 1:4:8 ,type D-2 with using 40 mm graded stone aggregate as in foundation,mass filling,etc.complete.
M&L for 100 mm thick PCC 1:4:8 ,type D-2 with using 40 mm graded stone aggregate as in sub base to floor over hard core surface,etc. Complete.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and runing rails and guide rails, sliding doors; fixed with angle cleats or other connecting plates.all as specified and directed.
M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as of roof covering/ridges fixed with self tapping screws as specified and as directed.
M&L for 2 coats of synthetic enamel paint over a coat of red oxied primer including preparation of new steel surface of any description over 10 cm width and girth.
M&L for 150 mm thick hard core of gauge not exc 63 mm,,deposited,spread and levelled in layers n. Exc.15 cm thick,waterd and rammed to a true surface.
Taking down wall/floor tiles incl cement mortar bedding,etc .complete.
M&L f0r 150 mm dia RCC hume pipes,class NP-2,laid and jointed complete with collars,laid over 150 mm thick Pcc 1:4:8,type D-2 ,bed concrete to pipe foundation.
M&L for Precast reinforced cement concrete tyoe B-1,1:2:4 with using 20 mm graded stone aggregate as in manhole cover slab,etc. Complete.
S&F soap dish vitreous china,approximate size,160*160*90 mm
S&F 600 mm long and 20 mm dia CP towel rail fixed with cp screws.
S&F 4.8 mm thick sheet glass ordinary quality and fixed to door frame with rubber beading exc.0.5 sqm each,etc.complete.
S&F Aluminium die cast door closer hydraulically regulated designation No.3 universal type,suitable to door shutters of 851 to 1000 mm in width and of wight 610to 80 kg,etc. Complete.
Taking town chowkhats with shutters exc 1.50 sqm but not exc.4.00 sqm each,etc. Complete.
Demlition of brick or concrete masonry work built in cement mortar.
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in sub base and similar works complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, infloors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as directed by Engr-in-Charge.
M&L for glazed ceramic coloured tiles 300x200x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as directed by Engr-in-Charge.
M&L for Precast cement concrete type B1 1:2:4 (20 mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, and similar articles including necessary form work.
M&L for MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire not less than 0.9 mm dia
S&F Vitreous china WHB of size 600*480 mm,flat back,waste pipes,plugs,brackets,fency type pillar tap,CP waste copline ,etc.complete.
Supply only integral water proofing compound.
M&L Applying two coats of cement base paint over a coat of primer on wall surfaces including perpartion of new plaster surfaces on walls
M&L for two coats of OBD over a coat of primer including prepartion of new surfaces on walls
M&L Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying and fixing in opening as per manufacturers instructions all as directed by Engineer-in-Charge.
Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing.
S&F 75 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin.
S/F 150mm size aluminium anodised handles, cast type.
S/F 150mm long aluminium anodised barrel tower bolt of extruded section.
S&F Vitreous china EWC with P or S trap,white fixing bolts,plastic seat cover closed pattern with flat backbottom, flush pipe ,low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge.
S&F 15 mm dia 45 cm long PVC water connection with PTMT nuts and washers all as directed by Engr-in-Charge.
S&F GI pipe medium grade 15 mm dia with all fitting laid in floor or fixed in walls.
S&F GI pipe medium grade 20 mm dia with all fitting laid in floor or fixed in walls/in floors.
M&L for PVC (SWR) floor trap, plain with grating including jointing with solvent cement outlet dia 75mm in repair.
S&F rotational moulded polyethylene water storage tanks 500 lts (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR part 1 and dismantaling of existing cement water tanks.
S&F 20mm dia gunmetal globe or gate valves with iron wheel head screwed both ends for iron pipe in repair
S&F ball brass valves 20mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule
S&F angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15 mm dia
S&F angle/stop valves cast copper alloy, screwed down high pressure fancy type chromium plated 15 mm dia with long shank and cup (concealed type) all as directed by Engr-in-Charge
S&F CP Bib taps 15 mm dia with crutch or butter fly handle fancy type
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 110 mm.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore of the pipe 75 mm.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall, bore of the pipe 110 mm.
S&F PVC (SWR) bends any radius 110 mm dia with access door.
S&F PVC (SWR) bends any radius 75 mm dia with access door.
S&F PVC (SWR) junction single,(Single T) equal or unequal with oval access door bore of pipe 110 mm)
S&F PVC (SWR) junction single,(Single T) equal or unequal with oval access door bore of pipe 75 mm)
S&F PVC (SWR) vent cowl of 110 mm dia.
S&F Framed work such as grill,gratings,gates etc.with ends of bars shouldered or riveted,forged into spikes,framed guard bars,gates railings,ladders,etc.confirming to Fe-290,Gde E-165 incl portions framed and hung as ornamental and intricate design gates with pintal hinges,stops,hand made sliding bolts etc .complete.
M & L for RCC Nominal Mix,type B-1 with using 20 mm graded stone aggregate as in footing concrete foundation etc , complete.
M & L for RCC Nominal Mix,type B-1 with using 20 mm graded stone aggregate as in columns,pillars, etc , complete.
All as per item no131 above,but 5 mm and upto 10 mm dia TMT bars as in stirrups,spacers and binders,etc.
M & L for form work to sides of concrete in foundations,footing bases of columns,etc complete.
M & L for form work to sides of columns,pillars,posts,etc complete.
M & L for Precast concrete block masonry with PCC 1:3:6,type C-1 with using 20 mm graded stone aggregate,exc.10 cm width &setting and jointing in cm 1:6,etc.complete.
M & L for 15 mm thick plastering on concrete or brick masonry surface finished surface even and smooth without using extra cement in CM 1:6,etc.complete.
M & L for preparation of new plastered surface and provide two coats of cement base paint over a coat of primer,etc. Complete.
Returning & filling in including spreading,levelling,watering & well ramming in layers not exc.25 cm ,etc complete.
Removal of surplus excavated material exc 250 mtr and not exc.500 mtr depositing where directed at alevel n. Exc. 1.50 m above the starting point,etc complete.
Surface excavation not exc.30cm in deep and avg 15 cm n depth and getting out in soft/loose soil
M&L for 100 mm thick, PCC 1:4:8 ,Type D-2 with using 40 mm graded stone aggregate as in sub base to paver block.
M&L for 60 mm thick,Glossy finish, Machine pressed precast cement concrete Interlocking paver block of any shape and size confirming to IS-15658-2006, with grey cement and pigment,etc complete.
M&L for 40 mm thick sand cusion for paver block.
S&F Anodised Aluuminium powder coated section,weighing 0.55 kg/Rm for doors section,partion walls,etc.incl necessay glazing clips,rubber packing ,handles,hinges and screws etc.complete
M&L for18 mm thick fire resistance fibre insulation board ,flame proof type fIxed as in partion of verandah.
S&F Anodised Aluuminium powder coated section for doors frame,partion walls,etc.incl necessay jointing cleats,etc .complete all as specified . etc.complete
Preparation of new steel surfaces over 10 cm in width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer .
PART - I E/M PORTION (SPL REPAIRS TO QTR NO P-21 & P-22) Taking down carefully aluminium / copper point wiring complete (light, fan socket & power) including unserviceable fixtures and fittings such as switches ceilimg roses pendents regulators sockets light fittings etc complete removing material to store for keeping in safe custody for taking credit & making good disturbed wall / floor etc complete all as directed by Engineer-in-Charge
Taking down sub main wiring with UG Cable complete including fitting and fixtures, removing materials and making good the disturbed surfaces of walls, floors, roof etc, all as specified and as dirfected.
Taking down carefully unserviceable VTPN/DBs with MCB/MCCBs any type/size disconnecting and making good disturbed surfaces complete all as directed
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through and including rigid PVC cassing and caping fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor cable as earth dolly, including Concealed MS box with 3 mm thick laminated sheet cover fixed with brass screws and cup washers for mounting of plate mounting for housing the switches, socket outlets, fan regulators etc and including of cutting chasses making good disturebed surfaces all as specified and as directed . (a) One light point controlled by one way switch
(b) One light point controlled by Two way switch
(c) One fan point controlled by one switch and one regulator.
(d) One socket point 6 Amps on same board
(e) One socket point 6 Amps on independent board
S & Fix piano flush type switch 1 way 5A
S & Fix piano flush type switch 2 way 5A
S & Fix socket out let 5A 2 in 1,5pin
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix fan regulator electronic type volts AC 50 HZ ,4 step, 100 v complete all as directed.
S & Fix lamp holder PVC type with back plate suitable for lamp holder fitting.
S & Fix Baton for LED tube light 18 Watts with all Fixing arrengenment all as specified and directed by Engr-in- charge. Make: - Bajaj, Cat part no-BCLSB 18 WH or eqvt wipro/crompton/Jaquar.
S & Fix Baton for LED tube light 10 W withall Fixing arrengenment all as specified and directed by Engr-in- charge.Make:- Bajaj, Cat part no-BCLSB 10 WH or eqvt in wipro / Havell/Jaquar.
S & Fix DB VTPN 4 ways,with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going,VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to legrand for fixing on surface of wall all as directed by Engr-in charge. Make:- Legrand, Cat part no-507750 or eqvt in Standerd/ C & S/L&T/ABB.
S & Fix sheet metal enclosure distribution board SPN, 4 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete.
S & Fix sheet metal enclosure distribution board SPN, 2 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed including taking down old MCB DB complete.
S & Fix MCCB , 4 pole, 415 volts,16 KA, 63 Amps, all as specified and as directed.
S & Fix of MCB single pole and neutral, 240 volts, 5 to 63 Ampere, rupturing capacity 10 KA complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA complete all as specified and directed.
S & Fix LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 66 and complete accessories all as specified and directed by Engr-in-charge. Make: Wipro Cat No-LR02-331-XXX-57-XX or Eqvt in Havells/Bajaj/Jaquar.
M&L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC casing and capping with its accessories all as specified and directed by Engr-in -charge for the following (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire
(b) 2x4 sq mm and 1x4 sq mm as earth wire
Taking down the existing electric meter of any capacity and make after disconnecting electrically and examine carry out the servicing and refixing including applying one coat of paint(outer box), testing in all respect for smooth running complete.
M & L for Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less that 1.5M below normal ground level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
PART - I E/M PORTION (EXTERNAL ELECTRIFICATION) Supply and Laying and testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 4 core cable connecting lugs, glands,jointing materials etc, laid on wall, floors, roof, ducts and fixing using clamps, saddle complete all as directed by Eng-in-charge of following.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 30 cm wide and not exceeding 60 cm deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 50 mm dia
PART - II E/M PORTION (ADDN/ALTN TO ANNEXE AIR HANGER) Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials for taking credit and making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed.
Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates with frame and modular flush boxes for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and directed . (a) One light point controlled by one switch.
(b) One Exhaust fan point controlled by one switch.
S & Fix modular switch single pole,one way 6 Amps capacity
S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix Baton for integrated LED Chanel fitting 18 W with complete accessories and fixing on wall / floor/roof etc all as specified and directed by Engr-in- charge. Make: - Bajaj, Cat part No- BCLSB 18 WH or eqvt wipro/crompton/Jaquar.
S & Fix Baton for integrated LED Chanel fitting 10 W with complete accessories and fixing on wall / floor/roof etc all as specified and directed by Engr-in- charge. Make: - Bajaj, Cat part No- BCLSB 10 WH or eqvt wipro/crompton/Jaquar.
S & Fix sheet metal enclosure distribution board SPN 2 ways 240 volts with IP 43 protection and single door, suitable for mounting MCBs all as specified and as directed.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
S & Fix MCB single pole & neutral, 240 volts, 6 to 40 Amps, all as specified and as directed.
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC conduit fixed to walls / roofs / floors / ceiling/Chenel etc with its accessories all as specified and directed by Engr-in -charge for the following. (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire
S & Fix PVC Exhaust fan AC single phase 240 volts of size 250 mm sweep, 240 RPM with fixing arrangement complete all as specified & directed Make - Bajaj/Havells/Usha.
PART - II E/M PORTION (EXTERNAL ELECTRICAL) Supply and Laying in trenches LT underground cable ISI marked XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, making hole in wall as per requirement at site complete all as directed by Eng-in-charge of following:- (a) 2 core 6 Sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Supply & Laying 40 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
M &L for GI pipe medium grade, for road crossing / on wall / on pole for cable protection of following size. Make:- TATA/JINDAL/ PRAKASH SURYA a) 40 mm dia
S & Fix outdoor type FRP junction box suitable for pole/wall mounting inclduing MCB SP 6 Amps single pole and necessary connectors for loop in loop out cable connection and suitable size IP 55, size 370 x 270 x 210mm all as specified and directed. Make :- Syntex/ Anchor
S & Fix LED RUBY (clear) 25 W LED Post top fitting, IP - 65 new genration, post top,energy saving, environmental friendly, long life aesthetically designed with symmentrical light distribution spun aluminium landscape luminaire with high powder LEDs as light source compartable for all gate piller and including GI pipe required to sizes to fixed at site by growting in wall/roof /piller/boundary wall and PCC foundation as persite requirement. Make :- Havells cat part no - RUBYPT25WLED757PSYMTOPC or eqvt in Bajaj/crompton /wipro
S & Fix LED bollard garden light fitting 9 W IP - 65 with opal acrylic diffuser and including nut, bolts, all fixing arrangement and PCC foundation as persite requirement . Make :- Bajaj cat part no -BGBOM650 9W LED or eqvt in / Crompton /wipro/Havells
Mehta and Co.
M/S SUGAM CONSTRUCTION
DAKSH ENGINEERS AND BUILDERS
M/S OMSAI ENTERPRISES
G V HAGAWANE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .