MZ-137, Main Building, IIT Delhi 110016
Construction of temporary Lab for Textile Department in open area at Backside of Central workshop at IIT Delhi.
2022_IIT_699072_1
IITD/ WORKS(SP- 3918)/2022
Open Tender
Miscellaneous Works
Works
75 days
Indian Institute of Technology Delhi
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,000
Registrar IIT Delhi
₹1.1 L
22 Jul 2022
7 Jul 2022
15 Jul 2022
7 Jul 2022
14 Jul 2022
7 Jul 2022
Amount
1) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
1.1) All kinds of soil.
2) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
5) Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
6) Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended roportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the ollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
7.1) All works upto plinth level:
7.1.1) M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
8) Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
8.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
8.2) Centering and shuttering including strutting, propping etc. and removal of form for
8.2.1) Foundations, footings, bases of columns, etc. for mass concrete
9) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
9.1) Thermo-Mechanically Treated bars of grade Fe-500D or more
10) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
11) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
11.1) Cement mortar 1:4 (1 cement : 4 coarse sand)
12) Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
13) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
14) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
15) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
16) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
16.1) Twin rubber stopper
17) Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
17.1) Hot finished welded type tubes
18) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
19) 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
20) Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
20.1) Size of Tile 600x600 mm
21) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
22) 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats ofmprimer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :.
22.1) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
23) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
24) Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
24.1) Ridges plain (500 - 600mm)
24.2) Gutter (600 mm over all girth)
25) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
25.1) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing
26) Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer-inCharge.
27) 12 mm cement plaster of mix :
27.1) 1:4 (1 cement: 4 coarse sand)
28) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
29) Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
29.1) Two or more coats on new work
30) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
31) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
32) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
32.1) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
33) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
34) Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
35) Providing and fixing soil, waste and vent pipes : 75 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
36) Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989
37) Providing and fixing plain bend of required degree. 75 mm dia, Sand cast iron S&S as per IS - 3989
38) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
39) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :75 mm
40) Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet : Sand cast iron S&S as per IS - 3989
41) Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
41.1) 20 mm dia nominal bore
42) Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
42.1) 15 mm dia nominal bore
43) Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
43.1) 25 to 40 mm nominal bore
44) Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
44.1) 20 mm nominal bore
45) Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
45.1) 20 mm diameter pipe
46) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
46.1) 20 mm nominal bore
47) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
48) Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
48.1) 150 mm diameter
48.2) 200 mm diameter
49) Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
49.1) 150 mm diameter S.W. pipe
49.2) 200 mm diameter S.W. pipe
50) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
50.1) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
50.1.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
51) Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
51.1) For pipes 100 to 250 mm diameter
52) Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
52.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
53) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
53.1) For fixed portion
53.1.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
54) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
54.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
55) Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.
55.1) Pre-laminated particle board with decorative lamination on both sides
56) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
56.1) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
57) Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete
57.1) Upto 5mm depth and 5 mm width
58) Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
59) Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
60) Providing and fixing roller blinds, the febric should be screen openness of 5% and composition of 75% PVC 25% polyster with fabric weight of 465 GSM with fire resistance grade of NSPA 701, BS 586 part- II with anodized aluminium channel weight, bracket and hangers etc. the fabric will be approved colour and shed of approved manufacturer complete. Make (VISTA/MAC/Marvel)
61) Providing and fixing GI tank Nipple of approved make in PVC tanks as per directions of Engineer-In-Charge.(20 mm nominal bore)
62) Providing and Fixing of gun metal gate valve with C.I. wheel of approved quality complete as per directions of Engineer-In-Charge. (Make: Zoloto/Leader/Sant) 20mm nominal bore
63) Providing and fixing 10 mm thick non - asbestos multipurpose cement board rainforced with cellulose fiber manufactured through autoclaving process ( high pressure steam cured ) as per IS:14862 of Everest industries Ltd or equivalent make , over the exidting MS frame work ( to be paid in basic items ) with 25 mm counter sunk ribbed hard screws @200m center to center.
64) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
64.1) Group C
65) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
65.1) Group C
66) Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
67) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
68) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
68.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
68.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
68.3) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
68.4) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
69) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
69.1) 3 x 4 sq. mm
69.2) 6 x 4 sq. mm
69.3) 6 x 6 sq. mm
70) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(Make Delton / Polycab / Finolex)
71) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
72) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
72.1) 5/6 A switch
72.2) 15/16 A switch
72.3) 3 pin 5/6 A socket outlet
72.4) 6 pin 15/16 A socket outlet
72.5) Telephone socket outlet
73) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
74) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
74.1) 1 or 2 Module (75mmX75mm)
74.2) 3 Module (100mmX75mm)
74.3) 12 Module (200mmX150mm)
75) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
76) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Havells/ Beldon/ D-Link/ Polycab)
76.1) 1 run of Cable
76.2) 2 run of Cable
76.3) 3 run of cable
77) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Legrand (DX MCB,s) / Schneider / L&T / ABB)
77.1) 125 A, 16 kA,TPMCCB
77.2) 150 A, 16 kA,TPMCCB
78) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make Legrand (DX MCB,s) / Schneider / L&T / ABB)
78.1) 8 way , Double door
79) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (MCCB as a incomer) (Make Legrand (DX MCB,s) / Schneider / L&T / ABB)
79.1) 4 way (4 + 12), Double door
79.2) 8 way (4 + 24), Double door
79.3) 12 way (4 + 36), Double door
80) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make Legrand (DX MCB,s) / Schneider / L&T / ABB)
80.1) Single pole (10A-6 No & 32 A - 36 No)
80.2) Triple pole (32 A-12 No)
81) Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make Legrand (DX MCB,s) / Schneider / L&T / ABB)
82) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.(Make Schneider / L&T/ ABB / Legrand)
83) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (Make Schneider / L&T/ ABB / Legrand)
84) Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
85) Supplying and Fixing DLP U-PVC turnking of 105mm x 50mm on surface etc as required.(Make Legrand / Schneider)
86) Supplying and Fixing Full Flexible cover of width 85mm on existing DLP U-PVC turnking etc as required.(Make Legrand / Schneider)
87) Providing and fixing of 90° Flat angle for 105 mm x 50 mm trunking (Make: Legrand)
88) Supplying and fixing following modular information socket on the existing modular plate & G.I box including connections but excluding modular plate etc. as required.
88.1) Information socket - category 6-UTP - 1 module (Make: Legrand)
MAINTENANCE FREE ADVANCE CHEMICAL GEL EARTHING SYSTEM.
89) Supply, Making, Testing & Commissioning of advance maintenance free Chemical Gel Earthing of Single solid Pipe Technology (Copper) of 3mtr long 50mm dia filled with highly conducting metallic compounds (Make Earth Plus Ultra IEC 62561-7,IS-3043) with the permenant sealings at the both the ends with the lead terminal 32x10mm at the top along with 50 Kgs of chemicals Gel for (mixture of Sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Potassium Oxide, Chloride, Nickel Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide, etc) Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound RESLOW shall be less than 20%. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization.
89.1) The testing laboratory should be ISO 9001 & ISO 14001 certified. The JK CHEMRODE shall be be duly tested & certified by CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 30 KA rms. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization.
89.1.1) Supply & Installation of Heavy duty polyplastic weather proof earth pit / chamber.
90) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
91) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
92) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
93) Providing and fixing 160A,25kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in SS enclosure suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system complete with powder coating in approved shade including drilling holes in cubicle panel, making connections, etc. as required. Make l&T/Schneider/Legrand/ABB
94) Providing and fixing 250A,36kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in SS enclosure suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system complete with powder coating in approved shade including drilling holes in cubicle panel, making connections, etc. as required. Make l&T/Schneider/Legrand/ABB
95) Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on wall surface as required.
95.1) Upto 35 sq. mm (clamped with 1mm thick saddle) (3C x 16 Sq.mm)
95.2) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 120 Sq.mm)
96) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
96.1) 3 X 16 sq. mm (25mm)
96.2) 3½ X 120 sq. mm (45mm)
97) S/I/T/C of recess mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage not more then 36 watts, Output lumens not less then 33001m; CCT not less then 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; power factor not less then 0.9; Minimum IP protection 20. with chain & hook etc as required. (Make : Philips/ Wipro/ Havells)
98) S/I/T/C of recess mounting round/square LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage not more then 12 watts, Output lumens not less then 6501m; CCT not less then 5700K; slim profile surface mounted down light square/ round type; Normal surge protection 2.5kV; power factor not less then 0.9; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells)
99) Supplying, Installation, testing & commissioning of energy efficient LED compound light equipped with power coated PDC alluminium body & secondry optical lens for superior light distribution with energy efficient electronic driver with following features:- 130-300 Vac, 50Hz, wattage not more then 30 Watts, efficancy not less then 110 Lm/W, CCT 5700K, Nominal surge protection 2.5 kV, Power factor not less then 0.9, Minimum IP protection 66 etc. in suitable size GI pipe with reducer, GI saddle, bracket for proper fixing as required. (Make: Panasonic/Philips/Havells/ Wipro)
100) Supplying and fixing of 40 mm dia medium G.I. pipe of 1.5 meter long L type on surface of wall fitted with GI/MS bracket with reducer etc. complete as required.
101) S/I/T/C of surface mounting LED batten luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage not more then 20 watts, Output lumens not less then 1800lm; CCT not less then 6500K; Length 4 feet; normal surge protection 2.5kV; power factor not less then 0.9; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells)
102) S/I/T/C of high speed wall mounting fan 400 mm sweep, copper winding, capacitor start, suitable for operation on 230V, 50 Hz, AC supply with inbuilt speed regulator etc. complete with all standard accessories such as motor, blades clamp etc as required. (Make : Havells/ Crompton/ USHA/ Orient) Colour of fan shall be finallized by Engineer-in-charge)
103) Supplying, Installation, Testing and Commissioning of 1200 mm sweep, 32 Watt BEE 5 star rated, ceiling fan with brush less Direct current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts; washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Havells/ Crompton/ Orient/ )
104) S/I/T/C of 10"(250mm) size,copper wound, ventiling fresh air fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Ventil Air-DX White.
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)
105) Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
106) Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
107) Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
108) Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
109) Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
110) Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Air Conditioning
111) Supplying, Installation, Testing and Commissioning of Split type Air Conditioner unit for cooling comprising factory built evaporator and condenser unit with other kits (remote controller with battery, suction & discharge copper pipe of length not less than 3 m each, copper cable for power connection, etc.) for installation as per following specification: Rated cooling capacity: 1.5 TR (not less than 5250 watts); Star Rating 5 star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Ecofriendly; Material of evaporator & Condenser refrigerant pipe : Copper; Suitable for operation on 230 volt, 50 Hz, AC supply Make ( Hitachi / Blue Star/ LG/ Voltas/ LLOYD/ Haier/ Daikin/ Mitsubishi/ O General)
112) Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for split AC unit, complete with fittings, with suitable adjustable ring type hanger supports (wherever required), jointing / brazing including accessories, insulated with nitrile rubber tube sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro]; [Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam]
112.1) NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The thickness of fittings used shall be same as that of the pipe
113) 15.86 mm (5/8 inch) dia (OD) (Soft drawn) with tube thickness 1.2 mm with class - 1 nitrile rubber tube (foam) insulation of not less than 9 mm thick.
114) 9.5 mm (3/8 inch) dia (OD) (Hard drawn) with tube thickness 1.2 mm with class - 1 nitrile rubber tube (foam) insulation of not less than 9 mm thick.
115) Supplying and laying ISI marked 25 mm dia pvc pipe (flexible & braided type) for drain line, including providing insulation wherever necessary, proper saddling, etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
116) Supplying and laying of ISI marked hard CPVC pipe of 25 mm dia for draining of sweated water from AC evaporator unit including all accessories providing tee, joints, elbows, insulation wherever necessary etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
117) Supplying and laying of ISI marked FRLS 4 core x 2.5 sqmm PVC insulated industrial flexible copper conductor cable of 1.1 kV grade conforming to IS 694:2010 including making connections etc. as required. (Acceptable make: Havells / Finolex / Polycab / RR Kabel / KEI / Sterlite / Shilpi / Anchor / Universal)
118) Supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface(Floor mounted) or on wall [as per site requirement - either floor mounted or wall mounted], duly prepainted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, etc. complete as required.
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .