| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.9 L+₹1.4 L (4.14%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹37.7 L+₹3.2 L (9.38%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹37.8 L+₹3.3 L (9.44%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹39.6 L+₹5.1 L (14.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | ROYAL CONSTRUCTION L1 | M/S RAKESH TRADERS L4 | RAJPATI CONSTRUCTION L6 | City buildcom builders & devlopers L2 | CREATIVE CONSTRUCTION L3 | M/S AJAY JAIN L5 | SHIV SHANKAR MISHRA L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | ||||||||||
| 1.10 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m and getting out in any type of soil complete all as specified and directed. | 62.75 | Cum | 120 ₹7,530 | 180 ₹11,295 | 145 ₹9,098.75 | 120 ₹7,530 | 110 ₹6,902.5 | 100 ₹6,275 Lowest | 400 ₹25,100 |
| 2.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and directed. | 57.95 | Cum | 120 ₹6,954 | 200 ₹11,590 | 150 ₹8,692.5 | 120 ₹6,954 | 110 ₹6,374.5 | 100 ₹5,795 Lowest | 400 ₹23,180 |
| 3.00 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in mass concrete as in foundation filling and mass concrete complete all as specifed and directed. | 7.03 | Cum | 2,200 ₹15,466 Lowest | 3,000 ₹21,090 | 2,800 ₹19,684 | 2,500 ₹17,575 | 3,200 ₹22,496 | 2,800 ₹19,684 | 2,500 ₹17,575 |
| 4.00 | Use and waste of formwork to sides of concrete foundation, footing, base of columns, raft, raft beam sides and soffits of foundation and plinth beam for rough finished flat surfaces of concrete complete all as specified and directed. | 118.12 | Sqm | 230 ₹27,167.6 | 150 ₹17,718 Lowest | 280 ₹33,073.6 | 280 ₹33,073.6 | 250 ₹29,530 | 300 ₹35,436 | 400 ₹47,248 |
| 5.00 | Use and waste of formwork for to sides of pillar, post, struts, pier column, beams or wall for rough finished flat surfaces of concrete complete all as specified and directed. | 13.2 | Sqm | 230 ₹3,036 | 150 ₹1,980 Lowest | 350 ₹4,620 | 280 ₹3,696 | 250 ₹3,300 | 300 ₹3,960 | 400 ₹5,280 |
| 6.00 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers for rough finished flat surfaces of concrete complete all as specified and directed. | 24.12 | Sqm | 230 ₹5,547.6 | 200 ₹4,824 Lowest | 350 ₹8,442 | 280 ₹6,753.6 | 250 ₹6,030 | 300 ₹7,236 | 400 ₹9,648 |
| 7.00 | Use and waste of formwork to soffits of suspended slab sucha s roof slab, floor slab, landing and similar work not exc 200 mm thick (horzontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed. | 27 | Sqm | 240 ₹6,480 Lowest | 250 ₹6,750 | 280 ₹7,560 | 280 ₹7,560 | 300 ₹8,100 | 300 ₹8,100 | 400 ₹10,800 |
| 8.00 | M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beam, plinth beams for coloumns and mass concrete etc, complete all as specified and directed. | 14.01 | Cum | 5,000 ₹70,050 | 5,500 ₹77,055 | 5,700 ₹79,857 | 5,500 ₹77,055 | 4,100 ₹57,441 Lowest | 5,000 ₹70,050 | 5,000 ₹70,050 |
| 9.00 | M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed. | 0.97 | Cum | 5,000 ₹4,850 | 6,000 ₹5,820 | 5,700 ₹5,529 | 5,500 ₹5,335 | 4,100 ₹3,977 Lowest | 5,500 ₹5,335 | 5,000 ₹4,850 |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
15 Jul 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
PROVN OF LAND FILLING WITH RESURFACING CHAIN LINK AND OVERHEAD COVER TO STANDS OF JIT SINGH STADIUM 3 EME CENTRE AND PROVN OF 02 TOILET CUM BATHROOM ALONGWITH COMPLETE SANITARY FITTINGS NEAR BLDG NO P 640 FOR SINGLE JCOS ACCN UNDER GE BHOPAL
2025_MES_715628_1
8397/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹94,800
Yes
26 Sept 2025
19 Jun 2025
17 Jul 2025
19 Jun 2025
15 Jul 2025
3 Jul 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in mass concrete as in foundation filling and mass concrete complete all as specifed and directed.
Use and waste of formwork to sides of concrete foundation, footing, base of columns, raft, raft beam sides and soffits of foundation and plinth beam for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork for to sides of pillar, post, struts, pier column, beams or wall for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to soffits of suspended slab sucha s roof slab, floor slab, landing and similar work not exc 200 mm thick (horzontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beam, plinth beams for coloumns and mass concrete etc, complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate ) as in columns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canoies, deck slab or similar work complete all as specified and directed.
M&L for mild steel TMT bars, 10mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars, 6mm to 8mm dia, cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars, 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length bent to shape as required including cranking bending spirally for hopping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F of pre-coated coloured galvalume aluminum zinc coating profile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ:150 as in roof covering/ clading to wall, including crimping sheet at end and fixed with self tapping screws complete all as specified and directed.
S&F of 0.5 mm thick plain precoated coloured galvalume sheet for ridge having tensile strength of 550 Mp, AZ:150 fixing for closing gable truss suitable for profile pattern sheet and fixed with self tapping screws complete all as specified and directed.
S&F of mild steel framed work in roof trusses, trussed, purlin, crane gantries, rails and fastenings and heavy braket framing (beams, tee, angle, channel or flat sections) including distance pices, cleats etc (welded/ reviting) conforming to Fe 410-W (Gde-E250) quality 'A' complete all as specified and directed.
S&F of structural mild steel work as in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St.-240 complete all as specified and directed.
S&F of 5mm thick or over in thickness mild steel plates (plain or chequered) channels, square cut to or notched, forming holes with riveted bolted or welded attachment conforming to Fe-410-W complete all as specified and directed.
S&F of mild steel screw bolts (machine made) with hexagonal / square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, length of bolt exc 5cm and n. exc 10cm, dia of shank 5 to 10 mm for fixing fencing including necessary drilling hole on wall/ floor/ angle iron complete all as specified and directed
S&F of mild steel screw bolts (machine made) with hexagonal / square heads at one end and screwed the other/ screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5 cm and not exc 30 cm long, dia of shank 16 to 20 mm complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of on newly plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs coping and similar work complete all as specified and directed.
Supplying approved earth (from out side MD land) and filling at any other locations including spreading, levelling in layers n exc 25cm, watering and well ramming complete all as specified and directed.
Rolling and consolidating formation surfaces with power roller exc 8 tonne but n. exc 12 tonne complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar (1:4) on brick masonary/ concrete surface, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of premium acrylic smooth exterior paint with silicone additives of required shade @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed.
Excavation in post holes (or similar holes) each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in hard dense soil complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for mild steel work as in hand rails, half round or other steel section, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F of chain link fencing including line wires, any mesh, size and type to any standards, rails straining bolts etc including provn of binding wire complete all as specified and directed.
Removing surplus soil obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting paint complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for Brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 Cum per square metre complete all as specified and directed.
M&L for providing polythene film, 150 micron thick, laid over a coat of bitumen primer @ 0.30 to 0.50 Kg per sqm complete all as specified and directed.
M&L for hardcore of broken stone gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base for floors or similar work, finished even and rough complete all as specified and directed.
M&L for 25 mm thick cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) in levelling course of floors complete all as specified and directed.
M&L for providing non skid ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors over and including 15mm thick screed bed in CM 1:6; set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
M&L for providing glazed ceramic coloured tiles on vertical surface such as dado, riser, skirting etc; of size 350 x 250/ 450 x 300 & 7 mm thick over and including 10mm thick rendering in CM 1:4; set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 using water proofing compound as per manufacturer instructions on fair faces of brick work or concrete suface, finished even and smooth without using extra cement complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately as supply only.
M&L for 10 mm thick rendering in CM (1:6) on fair faces of brick work or conrete surfaces/ stone masonary and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
M&L for preparation of nely plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F of solid PVC door frame of size 50 mm x 47mm made out of 5 mm plain colour PVC sheet reiforced with MS square tube and fixing in opening as per manufacturer instructions complete all as specified and directed.
S&F of aluminium alloy, anodized sliding door bolt of 250mm length with hasp and staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F of 100 mm long butt hinges, medium weight, mild steel and fixed with screws complete all as specified and directed.
S&F aluminum handles cast type, anodized of 150 mm size complete all as specified and directed.
S&F aluminum anodised barrel tower bolt 150 mm extruded section and fixed complete all as specified and directed.
S&F of aluminium powder coated sections (minimum thickness of powder coating 50 micron) fabricated as for doors, windows, ventilators, partitions shutters and frames with or without sash bar including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete all as specified and directed.
S&F of 4 mm thick frosted glass and glazing to aluminium frame work with beading and rubber packing alround complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, finishing the surface even and smooth without using extra cement, laid in bays n exc 2 m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
S&F of vitreous china wash down water closed pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) but including plastic seat cover with aluminium hinging device complete all as specified and directed.
S&F of syphonic action type PVC low level flushing cistern of 10 ltrs capacity including 32mm dia flush pipe fixed to supply pipe and PVC connection 600 mm long 15 mm bore with brass heads & washers complete all as specified and directed.
S&F of 15 mm bore bib taps, brass chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe and fixed complete all as specified and directed.
S&F of 15 mm bore stop cock, brass chromium plated, fancy type with long shank and cup (concealed type), screwed down, screwed for iron pipe or union and fixed complete as specified and directed.
S&F of 15 mm bore angle cock, brass chromium plated with long shank and cup, screwed down, screwed for iron pipe or union and fixed complete as specified and directed.
S&F of vitreous china wash basins (flat back or angle back type) of 630 x 450 mm size including cutting for and pinning in ends of brackets or erecting stand/ supported on wall, fixing & supply of PVC waste pipe, CP waste coupling and 15 mm dia pillar taps, brass chromium plated, fancy type with capstan head, screwed down high pressure, with or without lettered Hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F of PVC connection 15 mm size with PTMT nuts of length 600 mm and fixed complete all as specified and directed.
S&F of brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges and fixed with screws complete all as specified and directed.
S&F of 25 mm bore GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F of 20 mm bore GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F of 15 mm bore GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F of 100mm dia CP grating and fixed complete all as specified and directed.
S&F of stainless steel soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls/ laid in trenches/ floors complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls / laid in trenches/ floors complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal and fixed with solvent cement complete all as specified and directed.
S&F of PVC (SWR) bends any radius 110 mm dia and fixed with solvent cement complete all as specified and directed.
S&F of PVC (SWR) bends any radius 75 mm dia and fixed with solvent cement complete all as specified and directed.
S&F of 75mm dia PVC (SWR) floor/ nahani trap with grating including jointing with solvent cement complete all as specified and directed.
S&F of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement in floor complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) vent cowl and fixed complete all as specified and directed.
S&F for chromium plated shower rose 125 mm size with or without swivel joints, any size including fixing to steel pipe or union complete all as specified and directed.
S&F of 500 Ltrs triple layer rotational moulded polyethylene water stotage tanks (cylinderical verticle with closed top) hoisted & fixed in position with and including 20 mm bore GI tank nipple complete all as specified and directed.
S&F of 20mm dia ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F of 20 mm dia Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F of 25 mm dia Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 10 mm thick rendering in CM 1:3 on concrete ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. notless than 150 gms/sqm) laid on bituminous primer conforming to IS: 3384-1965 @ 0.30 Kg/Sqm and impregnated APP membrane properly by forced application complete all as specified and directed.
S&F of 200 mm bore/ dia (DWCPE pipes) class SN-8 structural wall polyethylene (pipe with online coupler and elastomeric rubber ring) with hollow annular smooth outer surface and a smooth inner surface (double wall plain) for non-pressure underground drainage and sewage application type B nominal size (Dn/ID) made of polyethylene (PE) material confiming to IS: 16098 (Part II :2013) and to be transported, handled, installed and jointed as per Annex A of IS: 16098 (Part II : 2013) complete all as specfied and directed.
M&L for precast cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:4 complete all as specified and directed.
Cutting into existing manholes/ septic tanks for connecting new drains, making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1, smooth finished and reforming benching as required for 150 mm dia of pipe complete all as specified and directed.
M&L for point wiring with multi-stranded copper conductor stranded copper conductor cable of 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc. (ISI marked) with and including modular metal flush box (with earth dolly) and white modular cover plate as per site requirement for fixing of switches, sockets and fan regulators etc; with and including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:-
(a) One light/ fan/ bell point controlled by one, one way switch.
(b) One 3 pin socket outlet, 5 Amps on independent board.
(c) One 3 pin socket outlet, 5 Amps on same board.
All as per item No. 92.00 here-in-before but wiring for 5/15 Amps switch/ socket on independent board with 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade and 2 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly.
S&F of modular switch, one way, 6 Amps, 240 volts, 1 module complete all as specified and directed.
S&F in modular socket, 6 Amps, 2/3 pin combined, 240 volts, 2 module complete all as specified and directed.
S&F in modular switch socket combination, 6/16 Amps, 2/3 pin combined, 240 volts, 3 module complete all as specified and directed.
S&F of ceiling rose surface bakelite, 65 mm dia, three terminals, 230 volt AC complete all as specified and as directed.
M&L for sub main wiring with two single core PVC insulated FRLS cable 1100 Volts unsheathed with stranded copper conductor of 2.5 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. of 20 mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: Three runs of 2.5 sqmm cable PVC conduit pipe shall be measured as one unit length.
S&F of LED tube light fitting, surface mounted lumanaires, 1 x 20 W, 240 V, decorative ultra slim round /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally prewired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of ceiling fan complete with blades, down rods and accessories, 230 volts, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) with and including down rod extended upto 6 feet length complete all as specified and directed.
S&F of integral LED flood light luminaire of 200 Watts, high efficiency as per IS-16107, IP-66 degree of protection with pressure diecast alluminium housing and toughened glass and with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 2 core minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of sheet metal enclosure for MCB DB, TPN, 440 Volts, double door openable, recessed mounting, 4 ways, IP 43, ISI marked with 200 Amps rated bus bar, dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid separately.
S&F of MCB, SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 Amps including making connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of MCB, SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 Amps including making connection with suitable size aluminium / copper lugs complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:-Compacted/punned thickness shall be measured & paid.
Supply and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
Supply, laying, connecting and testing of UG LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 16 sqmm, 4 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc; including aluminium lugs at the termination ends complete all as specified and directed.
Supply, laying, connecting and testing of UG LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 25 sqmm, 3.5 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc; including aluminium lugs at the termination ends complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, cast iron cover with frame, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and directed. Note: The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above ground level.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 32x6 mm galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, cast iron cover with frame, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and directed. Note: The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above ground level.
Supply, fixing, commissioning and testing of CPRI approved factory made outdoor type LT panel board with aluminium bus bar of capacity not less than 1.5 times of incommer, platform mounted, cubical of appropriate size, self supported, front & rear openable, double door, hinged type with locking arrangement & sloping top canopy, suitable ventilation on both side, with wire mesh, IP-66 with dust & vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated of appropriate size, mounted/ fixed on 30 x 30 x 3 mm thick MS angle iron stand / frame 35 cm height from FFL duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, frame shall be grouted in PCC 1:2:4 type B1 using 20 mm graded stone aggregate in foundation, control wiring copper stranded PVC insulated FRLS cable connected from main bus bar, earth bus strip of 32 x 6 mm size for entire length of panel, suitable size of MS gland with gland plates and aluminum lugs/ thimbles for all incoming and outgoing cables complete all as specified and directed with and including comprising of the following for Panel :-
INCOMER: (i) MCCB, 4 pole, 63 A, 415 Volts with thermal magnetic release type & braking capacity of 16 KA - 01 No (ii) Phase indicating lamp, RYB neon type (set of three) - 1 Set (iii) VAF + PF Multifunction digital Meter - 1 No , OUT GOING:- (i) MCCB, 4 pole, 40 A, 415 Volts with thermal magnetic release type & braking capacity of 16 KA - 03 Nos (ii) MCB, SPN, 40 A, 415 volt with thermal magnetic release type & breaking capacity of 16 KA - 2 Nos Notes: 1. The LT Panel shall be brought from OEM/authorized dealer, CPRI approved factory from the attached list of make. The necessary certification shall be furnished by the contractor. The constructional drawing make of switchgear and hardware, size of panel board technical specification shall be submitted by the contractor for approval of Accepting Officer. 2. The minimum clearance of 10 cm between bus bar to bus bar & 20 cm between bus bar to earth/ body shall be maintained. 3. Any civil work involved in installation of panel shall be deemed to be included in the quoted unit rate.
M&L for sub main wiring with two single core PVC insulated FRLS cable 1100 Volts unsheathed with stranded copper conductor of 4 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. of 20 mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: Three runs of 2.5 sqmm cable PVC conduit pipe shall be measured as one unit length.
S&F of sheet metal earth plug & socket, single pole and neutral with and including 1 no. single pole MCB 20 Amps 240 volts complete all as specified and directed.
S&F of storage type steel body with glass line stainless steel inner tank nad heating element upto 2 KW electric water heater of 25 ltrs capacity with BEE 5 star rated, 230 Volts, max power consumption 2 KW, wall mounting type complete with all accessories such as safety valve, thermostat, NRVs, PVC connection pipe of 15 mm bore & 450 mm long- 2 Nos for Hot & Cold water supply and mounted on wall using wall fasteners and testing on completion complete all as specified and directed.
S&F of exhaust fan 300 mm sweep of steel body, AC single phase, 230 Volts, 1400 RPM with blades, frame and louvers with and including all civil work such as cutting circular opening in existing wall and making good disturbed surfaces as per existing including connecting up fan with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
City buildcom builders & devlopers (BID ID -3350984)
CREATIVE CONSTRUCTION (BID ID -3350154)
M/S RAKESH TRADERS (BID ID -3359592)
M/S AJAY JAIN (BID ID -3351152)
RAJPATI CONSTRUCTION (BID ID -3359818)
SHIV SHANKAR MISHRA (BID ID -3359204)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .