Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.8 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹12.8 L | L-1 | Accepted-AOC DUE TO BEING LOWEST AND REASONABLE |
| 2 | L-2₹12.9 LRejected-Finance 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | ₹12.9 L | L-2 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 3 | L-3₹13.4 LRejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹13.4 L | L-3 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 4 | L-4₹13.8 LRejected-Finance | ₹13.8 L | L-4 | Rejected-Finance FOUND OTHER THAN LOWEST |
| 5 | L-5₹15.3 LRejected-Finance R O BHARDA KALAN P O TEH AKHNOOR PIN 181201 DISTT JAMMU J K | JAMMU | JAMMU AND KASHMIR | 181201 | ₹15.3 L | L-5 | Rejected-Finance FOUND OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | M/S JIWAN SINGH L9 | UNITED ENGINEERING CORPORATION L3 | MAMTA ENTERPRISES L1 | M/S JEEVAN LAL SHARMA L5 | SHSS ASSOCIATES L4 | A K JAIN AND SONS L2 | M/S MARSHAL TRADERS L8 | VEDA INFRASTRUCTURE L7 | SHRI HARI CONSTRUCTION L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes/cable/pipe line/sewage line etc not exceeding 10 Sqm on plan not exceeding 1.5 m in depth and getting out in any type of soil, complete all as specified and directed. | 118 | Cum | 95 ₹11,210 | 160 ₹18,880 | 100 ₹11,800 | 145 ₹17,110 | 140 ₹16,520 | 250 ₹29,500 | 350 ₹41,300 | 130 ₹15,340 | 200 ₹23,600 |
| 2.00 | Returning filling in including spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick , complete all as specified and directed. | 81 | Cum | 10 ₹810 | 60 ₹4,860 | 10 ₹810 | 90 ₹7,290 | 20 ₹1,620 | 100 ₹8,100 | 230 ₹18,630 | 20 ₹1,620 | 60 ₹4,860 |
| 3.00 | Removing surplus soil to a distance not exe 50 mtr and depositing where directed at a level not exe 1.5 m above the starting point , complete all as specified and directed. | 37 | Cum | 10 ₹370 | 60 ₹2,220 | 10 ₹370 | 80 ₹2,960 | 20 ₹740 | 100 ₹3,700 | 250 ₹9,250 | 30 ₹1,110 | 55 ₹2,035 |
| 4.00 | M&L for Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.
Note: Punned thickness shall be measured. | 28 | Cum | 350 ₹9,800 | 553 ₹15,484 | 400 ₹11,200 | 700 ₹19,600 | 300 ₹8,400 | 500 ₹14,000 | 2,000 ₹56,000 | 900 ₹25,200 | 900 ₹25,200 |
| 5.00 | M&L for sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed . | 3.05 | 1000 Nos | 6,500 ₹19,825 | 5,199 ₹15,856.95 | 5,000 ₹15,250 | 5,000 ₹15,250 | 7,000 ₹21,350 | 5,000 ₹15,250 | 13,000 ₹39,650 | 6,000 ₹18,300 | 7,000 ₹21,350 |
| 6.00 | S&F tubes light grade, galvanised 40mm bore for cable protection with all fittings and fixed complete to walls and ceilings or laid in floors/road crossing, complete all as specified and directed. | 12 | RM | 200 ₹2,400 | 500 ₹6,000 | 450 ₹5,400 | 450 ₹5,400 | 300 ₹3,600 | 250 ₹3,000 | 320 ₹3,840 | 250 ₹3,000 | 350 ₹4,200 |
| 7.00 | Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. | 27 | Each | 8,500 ₹2.3 L | 7,400 ₹2.0 L | 8,400 ₹2.3 L | 12,750 ₹3.4 L | 7,800 ₹2.1 L | 6,000 ₹1.6 L | 6,500 ₹1.8 L | 7,500 ₹2.0 L | 5,500 ₹1.5 L |
| 8.00 | M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 core, complete all as specified and directed. | 390 | RM | 230 ₹89,700 | 280 ₹1.1 L | 220 ₹85,800 | 195 ₹76,050 | 230 ₹89,700 | 240 ₹93,600 | 320 ₹1.2 L | 260 ₹1.0 L | 300 ₹1.2 L |
| 9.00 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. | 12 | Each Set | 4,000 ₹48,000 | 5,400 ₹64,800 | 4,500 ₹54,000 | 5,500 ₹66,000 | 4,500 ₹54,000 | 5,000 ₹60,000 | 6,000 ₹72,000 | 6,600 ₹79,200 | 4,000 ₹48,000 |
| 10.00 | Design, Supply, Installation, Testing and Commissioning of High Mast Light System of 15 Metre height continuously tapered, complete with its accessories shall be in two section with material as BS-EV10 025,S355 with cross section as 20 sided polygon, single dipping, hot dipped galvanised and suitable for wind velocity as per IS 875( Part 3) 1987 and only longitudinal weld confirming to BS 5153/AWS. The High mast shall be comprising of the following technical specifications :
(a) High Mast shall have open raft shallow footing as foundation as per manufacturers design as per IS-456 and with 8 nos foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates according to drawings.
(b) An adequate door opening such that permit clear acces to equipments like winch, cable, wire rope, plug and socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal locking alongwith provision for external locking arrengements .
Cont... | 3 | Each | 5,22,552 ₹15.7 L | 3,00,000 ₹9 L | 2,91,000 ₹8.7 L | 3,25,000 ₹9.8 L | 3,25,000 ₹9.8 L | 3,00,000 ₹9 L | 3,80,000 ₹11.4 L | 4,10,000 ₹12.3 L | 4,00,000 ₹12 L |
Tender Value
₹18.2 L
EMD Value
₹36,500
Closing Date
15 Dec 2025, 6:00 pmClosed
GE, GE (SOUTH) AKHNOOR
Military Engineer Services Garrison Engineer (South) Akhnoor Pin- 900234 C/o 56 APO
PROVN OF HIGH MAST LIGHTS WITH ALLIED INFRA AT RAKHMUTHI MIL STN UNDER GE SOUTH AKHNOOR
2025_MES_741158_1
GES/AKH-61/2025-26
Open Tender
Electrical and Maintenance Works
180 days
RAKHMUTHI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹36,500
28 Jan 2026
24 Nov 2025
22 Dec 2025
24 Nov 2025
15 Dec 2025
8 Dec 2025
Amount
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes/cable/pipe line/sewage line etc not exceeding 10 Sqm on plan not exceeding 1.5 m in depth and getting out in any type of soil, complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick , complete all as specified and directed.
Removing surplus soil to a distance not exe 50 mtr and depositing where directed at a level not exe 1.5 m above the starting point , complete all as specified and directed.
M&L for Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed. Note: Punned thickness shall be measured.
M&L for sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed .
S&F tubes light grade, galvanised 40mm bore for cable protection with all fittings and fixed complete to walls and ceilings or laid in floors/road crossing, complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 core, complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Design, Supply, Installation, Testing and Commissioning of High Mast Light System of 15 Metre height continuously tapered, complete with its accessories shall be in two section with material as BS-EV10 025,S355 with cross section as 20 sided polygon, single dipping, hot dipped galvanised and suitable for wind velocity as per IS 875( Part 3) 1987 and only longitudinal weld confirming to BS 5153/AWS. The High mast shall be comprising of the following technical specifications : (a) High Mast shall have open raft shallow footing as foundation as per manufacturers design as per IS-456 and with 8 nos foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates and templates according to drawings. (b) An adequate door opening such that permit clear acces to equipments like winch, cable, wire rope, plug and socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal locking alongwith provision for external locking arrengements . Cont...
item 10 cont... (c) The structure of high Mast shall be designed to sustain an assumed maximum reaction of wind speed at the height of 10 Mtr above ground level (i.e. 180km/hr). (d) It shall also include accessories for high mast includes R&L system with double drum winch self lubricating & sustaining type having lifting capacity of SWL 750 kg, head frame, steel wire rope 6mm dia (7/19 construction) galvanised Lantern Carrige suitable for fixing of 9 lantern LED flood light fittings, symmetrically fixed. (e) Integral power tool having input supply 3phase 415 volts, single speed, 1.5 KW REVERSABLE type and average operating speed of 2 mtr per minute. (f ) Fabricate, supply, install, testing and commissioning of LT out door panel total enclosed LT panel board of suitable size as per OEM instructions totally enclosed made out of CRCA sheet not less than 3.15 mm thick , dust and vermin proof with front opening 440V 3 Phase 4 wire having 200 Amps capacity aluminium bus bar insulated wth sleeves, Incoming MCCB TPN 100 Amps 415 Volts 25 KA - 01 No, Outgoing MCCB TPN 63 Amps 415 Volts adjustable type with breaking capacity 25 KA - 01 No, MCB SPN 20 Amps 415 Volts adjustable type with breaking capacity 10KA - 01 No, cont....
item 12 cont...... (h) Provn of single pointed air termination rod and necessary fitment required for protection against lightning protection. (j) LED AVIATION lights TWIN type with polycarbonate diffuser & cast aluminium housing IP 65 (k) Weather proof hinged opening with locking arrangement at bottom of the mast for installation of winch and electric panel as per manufacturer recommendations. (l) Foundation RCC including design as per instructions and drawings of manufacturers recommendations suitable for 15 mtr high mast with accessories as detailed in respective items.
A K JAIN AND SONS (BID ID -3497769)
UNITED ENGINEERING CORPORATION (BID ID -3498386)
SHSS ASSOCIATES (BID ID -3498250)
M/S JEEVAN LAL SHARMA (BID ID -3498733)
SHRI HARI CONSTRUCTION (BID ID -3494740)
VEDA INFRASTRUCTURE (BID ID -3498594)
M/S MARSHAL TRADERS (BID ID -3498415)
M/S JIWAN SINGH (BID ID -3498205)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_829915.xls
BOQ • 0.33 MB
td612526.pdf
Tender Documents • 0.56 MB
Download all tender documents and submit your bid