Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.1 L+₹15,810 (0.48%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹33.5 L+₹53,772 (1.63%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹33.6 L+₹66,037 (2.01%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹33.9 L+₹95,164.50 (2.89%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
29 Sept 2023, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN-913867
REPAIR / MAINT OF INTERNAL WIRING, SUBMAIN WIRING, FITTINGS, FIXTURES ETC., AND LT SUPPLY SYSTEM, EXTERNAL ELECTRIFICATION AND CONNECTED MISC ITEM OF WORK AT RHENOCK AND RONGLI UNDER GE 867 EWS
2023_MES_617644_1
GE / 867 / TOKEN /38 OF 2023-24
Open Tender
Civil Works
Item Wise
270 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹61,000
2 Dec 2023
7 Sept 2023
2 Oct 2023
7 Sept 2023
29 Sept 2023
21 Sept 2023
7 Sept 2023 - 18 Sept 2023
Amount
M/L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly for One light/fan/bell point controlled by one switch 6 Amp one way complete all as specified and directed.
All as per item No. 01 here – in – before but one 3 pin socket outlet on same board with other switches complete all as specified and directed.
All as per item No. 01 here – in – before but one 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed.
All as per item No. 01 here – in – before but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed.
S & F in replacement under repair switch piano flush type single pole, one way 6A complete all as specified and directed. make: Anchor/SSK/Cona
S & F in replacement under repair switch socket combination 5 pin 6 A complete all as specified and directed. make: Anchor/SSK/Cona
S & F in replacement under repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
S & F in replacement under repair ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 230 volts ISI marked.
S & F in replacement under repair lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed.
S & F in replacement under repair flush type bell push 6 amp duly marked for bell complete all as specified and directed. Make : Anchor/ SSK / CONA
S & F in replacement under repair Electronic ding dong bell AC 230V single pole complete all as specified and directed. Make : Anchor/ Bajaj
S & F in replacement under repair fan regulator electronic type 100Watt 20V-50Hz as directed by Engr-in-charge. Make: Anchor cat No 38660 or equivalent
S & F in replacement under repair ceiling fan capacitor 2.5 mfd complete all as specified and directed.
S & F in repair Energy efficient LED tube light fitting 4", 1x18/20 watt, with bipin holders, connector block, CCT - 6500K, system output lumen not less than 1800lm, aluminium housing, surge protection range 3KV including connecting up with PVC insulated 3 core sheathed 0.5 sqmm copper conductor two numbers PVC mounting blocks for fixing of fitting complete all as specified and as directed by Engineer-in-charge. Make : Make : Batten : Cat part No- DMLN1LT8-16 and Tube Rod of Make Crompton Cat Part No : LTT8-20 or equivalent in Havells/Philips
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Crompton Cat part No "LDL-10-CDL" or equivalent in Philips/Havells.
S&F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Crompton Cat part No "LBH-10-CDL" or equivalent in Philips/Havells.
S&F in repair LED Building Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Crompton cat Part No "LST-25-CDL-M" or equivalent in Philips/Havells.
S & F in repair 9W LED Bulb suitable for B22 holder . System Efficacy should be > 85 lm/ W. PF > 0.9, The Lamp Should have Cool Daylight Color temp of 6500K, lumen output >800 lm. Make: Philips/Wipro/Crompton
Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Dismantling and taking out submain wiring 2/3/4/6 wire of any size, segregating for material for reuse, making good disturbed surface of walls/floors to match with existing surface and taking out from site all as directed by Engineer-in-Charge.
Dismantling damaged wooden boards of Electric meter by disconnecting all electric connection and S&F rectangular teak wood board of size 30cm x 25cm x 5cm deep with smooth hylem sheet top 5mm thick for mounting Electric Meter.MCB DB including making holes for incomming and outgoing wires and making necessary electrical connections incl painting of boards complete all as specified and directed.
S & F in repair MCB DB SPN 12 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed. Make : Legrand/Schneider/L&T
S & F in repair MCB DB SPN 8 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed. Make : Legrand/Schneider/L&T
S & F in repair MCB DB SPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed. Make : Legrand/Schneider/L&T
S&F in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. Make : Legrand/Seimen/Schneider
All as per item No.25 here – in – before but SPN 40 to 63 Amps 'C' curve. Make : Legrand/Seimen/Schneider
M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Supply and fixed on surface Rigid non metallic PVC casing caping of size 25mm including of all tee, bends, elbows and fixing accessories such as couplers, lock nuts,saddles, pipe hooks including taking down old broken PVC casing caping and making good surface complete all as specified and directed by Engr-in-Charge.
Supply and fixed on surface Rigid non metallic PVC casing caping of size 20mm including of all tee, bends, elbows and fixing accessories such as couplers, lock nuts,saddles, pipe hooks including taking down old broken PVC casing caping and making good surface complete all as specified and directed by Engr-in-Charge.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC(1:3:6) type C1 chamber, CI Cover with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe15mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc incl taking down old u/s earthing all as specified and as directed.
Refixing of old serviceable light fitting of any description including clamps etc as required complete all specified and directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mm. Make : Crompton Greaves, Model : BRISK AIR , or equivalent in USHA/Bajaj. Note: Old unserviceble ceiling fans will be deposited to MES Store at Rhenock.
S&F in repair sheet Metal Enclosure with socket plug top and MCBs double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V, 20 Amps incl taking down old u/s metal socket, make : ABB / L&T / C&S
S&F in repair decorative, wall mounting fixture in durable plastic body & designer mesh in gold finish suitable for 9 W retrofit CFL including necessary connection with 0.5 sqmm PVC sheathed 3 core copper cable and 14W LED lamp incl taking down old u/s light fitting. model "Glaze" of make : Havells or equivalent in Philips / Bajaj
Taking down existing unserviceable service cable of any size and S&F 1100 volts grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 10 Sqmm size (one twin core cable flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion complete all as specified and as directed by the Engineer-in-Charge. MAKE : FINOLEX/PLAZA/ HAVELLS/ POLYCAB/KEI.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete Including back plate heating element inner copper tank etc. De-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately)in relevent item including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulator tape required in work deem to be included in the rate.
All as per item No 37.00 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stop including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed. Note :- Any damage if occured during the process of cleaning the geysers will be made good by contractor at no extra cost.
M&L for 1.5 KW capacity Heating Element, triangular type including making electrical connection incl taking down old u/s heating element complete all as directed by the Engineer-in-Charge.
M&L for 2.0 KW capacity Heating Element, triangular type including making electrical connection incl taking down old u/s heating element complete all as directed by the Engineer-in-Charge.
Supply & fixing PVC connection heavy duty with brass/PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water incl taking down old u/s connection complete all as specified and directed.
Supply & fixing hot water outlet connection made of brass chromium plated with Union rubber washer suitable for 15 mm bore GI pipefor hot water incl taking down old u/s item complete all as specified and directed.
Supply & fix in replacement of thermostat (automatic cut of) of existing type & make, 15 Amps, 230/250 volts AC ISI marked complete all as specified and directed.
Supply & fix in replacement of indicator lamp assembly LED type RED/GREEN for geyser complete all as specified and directed.
S&F in replacement plug top 15 Amps240 Volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete. make Crompton cat part No "LCTLRNE-36-FO-CDL" or equivalent make in Philips/Havells.
Supply & fixing LED PL Lamp to the existing light frame or as per site including necessary connection and dismantling of existing defective fitting complete. similar to Make Philips, cat part No. LED PL-L 18W, 6500K 2G11 or equivalent make in Crompton/Havells.
S&F LED Driver for existing ceiling lights up to 36 W all as specified and directed. Make : Crompton/Havells/Philips
M&L in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed by Engr-in-charge.
All as per item No.49 here-in-before but of size 175 x 100 x 50 mm complete all as specified and directed.
All as per item No.49 here-in-before but of size 250 x 200 x 50 mm complete all as specified and directed.
M&L in repairs Hylam Sheet including suitable size of 04 Nos brass screws and cutting of hylam sheet for mounting, switches, sockets, fan regulator etc. of size 100 mm x 100 mm and 3 mm thickness complete all as specified and as directed by Engr-in-charge.
All as per item No 52 here-in-before but of size 175 x 100 x 50 mm complete all as specified and directed.
All as per item No 52 here-in-before but of size 250 x 200 x 50 mm complete all as specified and directed.
M&L for sheet metal enclosure double door TPN DB 4 Way all as specified and directed by Engr-in-Charge.Make - Havells/Legrand/Seimen
Taking down of exhaust fan upto 450/300mm sweep, opening, replacement of unserviceable accessories, servicing, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing / hanging in position from ceiling rose to fan complete as directed. (Note : gun metal bush, bearing will be measured and paid under relavant item here-in-after).
Supply only gun metal bush of sizes suitable for exhaust fan upto 450 mm sweep complete all as specified and directed.
Supply only ball bearing No 6203 suitable for fan of existing make type & sweep complete all as specified and directed. Make:- NBC/SKF/TATA
Checking of exhaust fan (of any sweep) by replacing unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed by Engr-in-Charge. (Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after)
M & L for painting of exhaust fan carefully with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as directed.
M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300mm dia all as specified and directed.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers in trenches complete all as specified and directed.Note :- Only Puned layers shall be measured for payment
M&L for well burnt bricks, sub class 'B' bricks of size 250mmx125mmx75mm, best quality locally available laid flat dry in trenches for cable protection complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size 50 sqmm to 120 sqmm from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of cable size of 95 Sqmm 3.5 core as required at site, Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of cable size of 70 Sqmm 3.5 core as required at site, Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of cable size of 35 Sqmm 3.5 core as required at site, Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of cable size of 25 Sqmm 3.5/4 core as required at site Make : MESCAB /HAVELLS /POLYCAB /KEI /GLOSTER or equivalent as approved by GE.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall/in trench with the help of shadel of cable size of 16 Sqmm 4 core as required at site Make : MESCAB/HAVELLS/POLYCAB/KEI/GLOSTER or equivalent as approved by GE.
Dismantling / Taking out Unserviceable GI pipe of any size removing material from site complete all as specified and directed by Engineer-in-Charge.
M & L GI tube light grade for passing through cables under the floor, along the wall or along the pole of 40 mm bore bore dia and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified.
M & L GI tube light grade for passing through cables under the floor, along the wall or along the pole of 25 mm bore dia and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified.
Dismantiling/taking out old unserviceable LT insulator any size, any type from poles.
S & F for pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade complete all as specified and directed.
S & F for Sackle type insulator porcelain vitreous white/ brown or green including one galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade complete all as specified and directed.
S&F in repair cable route marker of size 100 mm x 100 mm x 5mm thick with GI plate with inspection threon bolted / welded to 35 mm x 35mm x6 mm angle iron 60 cm long and fixing the same in ground as required for LT cable all as specified and directed by Engineer-in-charge.
S&F in repairs Busbar Chambers 8 way 100 Amps outdoor type (IP 65/66) pole mounted including provision of fixing on pole by means of suitable size of clamps with nut and bolts OR provision of fixing on 50 x 50 x 6mm thick angle iron frame work upto height of 0.9mtr above ground level including necessary connection completed all as specified and as directed. Make Havells cat part No IHBC010004 or equivalent make of SMC/Hencel.
Trimming of tree branches which touches the LT OH lines and 2.5 Mtr away from centre line of LT OH lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site. Note -Any number of tree branches cut in one span will be measured as one lenght of payment.
M & L for Plain Cement Concrete (1:3:6) mix type C2 (using 40 mm graded stone aggregate) in foundation, filling and mass-concrete etc for pole, stay etc all as specified and directed by Engr-in-charge.
M & L for Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregae) as in copping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-incharge.
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried on ground or drawn in conduit pipe or fixed to poles in repairs or any other indicated situation for the loop earthing etc. as required of size 32 x 6 mm galvanized iron strip complete all as directed.
Dismantiling and taking down unserviceable ACSR having more than two joints of any size and removing from site of work all as directed by engr in charge.
M&L for aluminium conductor steel reinforced ( ACSR ) including binding wires of suitable sizes and suitable conductors / parallel groove clamp Etc. other jointing materials for over head lines complete all as specified and directed by Engineer-in charge.
M&L earthing complete with galvanized steel earth plate electrode 600mmX600mmX6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and connected to and including using 32 x 6 mm galvanized MS strip wire upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES schedule Part-I, and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe 40 mm dia, light grade 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (a) Length of earthig connection incl GI strip and protection pipe more than 7.5 Mtr will be measured separately. (b) Contractor should conduct necessary test such as Earth continuity, earth resistance test in presence of JE (E/M)/Engr-incharge.
Dismantling / Taking down of cross arms of channel or sections etc complete setting aside for reuse (serviceable one) or removing from site of work all as directed and as specified.
M & L cross arms, bracings, supports clamps, stay clamps etc fabricated from structural steel sections including nuts, bolts, washers welding bending cold or hot drilling holes for bolts any size of shape and including hooks & clamps for aerial bunch cable as indicated and directed and inclusive of 2 coats of aluminium painting over a coat of red oxide primer all as specified and as directed.
Dismantling / Taking down old unsv stay assembly complete all as specified and as directed by engineer in charge.
M & L stay assembly with accessories as shown in Elect plate No- 01 of MES schedule Part-I complete with diameter of rod 16 mm . Note - Loop type insulator , stay clamps , excavation and concrete will be measured and paid separately .
S & F in repair loop type insulator vitreous porcelain white, brown, or green of size 65 X 90 mm clearance of hole 16 mm complete all as specified and directed.
M&L for painting of steel tubular pole of any size , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ) complete all as directed.
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as directed by Engr -in-charge. Note - (a) Any run of conductor in between two span in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor will be measured and paid separately.
M&L for Repairing of LT panel by means of replace the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs, replacement of suitable indicator with colour all as specified and as directed by Engr-in-charge.
S & F in repairs MCCB 4 pole 160 Amps, with thermal release range 70-100% and magnetic setting adjustable, breaking capacity 36 KA completed all as specified and as directed by Engr-in-charge.
S & F in replacement of existing type MCCBs of 100 Amps, 415Volt, breaking capacity 25KA, 4 Pole, completed all as specified and as directed by Engr-in-charge. Make : Legrand/L&T/Schneider
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand with synthetic enamel paint after cleaning the surface thouroughly with scrapper including protecting/cleaning of cables, wiring and other non painted parts complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from panel/trench by excavation) for outdoor termination Straight through tubular sleeve version type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 Sqmm complete all as specified and directed.
M & L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, including taking out old unserviceable rusted out danger plate.
M & L for DK Thermoplastic cable junction boxes in repairs of make Sintex, product code GSJB-3126, IP 65 of size 270x225x135mm of metric knockouts for cable entry, weather proof for indoor/outdoor installation with and including glands/insulators and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to wall/Steel Poles by means of suitable size of clamps with nut and bolts complete including taking down existing existing junction box all as specified and directed by Engineer-in-Charge. NOTE: Make of Junction box shall be Sintex/Hensel or equivalent as approved by GE.
Supplied and spreding graded coarse aggregae 40 mm nominal size all around the structure yard area all as directed by Engrs-in charge.
Taking out old unserviceable / faulty cable of any size /serviceable connecting cable of any size/grade cross sectional area up to 10 sqmm to 50 sqmm 3.5 core including brick protection for repairs/replacement etc and removing materials from site of work complete all as specifed and as directed.
All item No 105 here in above but 70 sqmm to 120 sqmm 3.5 core or 4 Core LT UG cable Note :- For Item No 105 & 106 (a) Relaying of cable after rectifying the fault, earth work shall be measured and paid separately under respective items. (b) Excavation and necessary earthwork shall ve measured and paid separtely under relevent item.
DEDUCTED AMOUNT OF SCHEDULE OF CREDIT
SANJAY SAW MILL
DEEP CHANDRA JOSHI
MANOJ JINDAL
SANJAY MITTAL
HEM RAJ GURUNG
M/S JAYSHREE CONCERN
RAMESH GURUNG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .