| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.6 L+₹18,714 (1.30%)Rejected-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹18.4 L+₹4.0 L (27.4%)Rejected-AOC 62 KRISHNA CHAMBERS PHASE III AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L3 | Rejected-AOC L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bhisiana
HQ CWE Bhisiana-151201
MAINTENANCE OF CENTRAL/ PACKAGE TYPE AC PLANTS INCLUDING ALLIED WORKS AT AF STATION SIRSA
2022_MES_508825_2
CWE(BHI)/SIR-59/2021-22
Open Tender
Civil Works
Item Rate
270 days
AF Sirsa
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Sirsa
₹40,000
Yes
25 Apr 2022
21 Mar 2022
13 Apr 2022
21 Mar 2022
11 Apr 2022
29 Mar 2022
21 Mar 2022 - 28 Mar 2022
60 days
Amount
M&L complete over hauling of compressor model. 5H40/ 5H46 Make - Voltas, including dismantling/opening of the compressor, segregation of serviceable parts, including grinding of crank shaft, replacement of shaft-seal assembly, grinding of valve plates, replacement of all bearings, replacement of piston pin piston ring and gasket set complete, replacement of oil filter, draining old compressor oil and filling new compressor and assemble all parts after serving and refitting compressor in posiotion and testing after errection to achieve specified inside tempreture complete all as specified and as directed. NOTE:- . 1. Transporation charges are deemed to be included in the quoted rates. 2. Compressor oil shall be measured seperately. 3. Any minor work/part replacement required during servicing for seccessful operation of compressor that is not mentioned in description has to to be done by contractor at no extra cost to the department.
Material and Labour for removing old existing unserviceable scroll compressor and supply, erection, commissioning of scroll compressor of cap 11.5/12.5/13 TR, Make- Danfoss.
Material and Labour for removing of unserviceable thermostatic expansion valve, supply and fixing thermostatic expansion valve, complete all as specified and as directed.
Supply and fixing in repair water flow switch for chilled water circuit suitable for 30/40/45/52 TR capacity AC Plant.
Supply and fixing in repair HP switches in position complete all as specified and as directed.
Supply and fixing in repair LP switches in position complete all as specified and directed.
Supply and fixing in repair Antifreeze switches in position complete all as specified and as directed.
Supply and fixing in repair Drier core in position complete all as specified and as directed. Make - Danfoss
Supply and fixing in repair Immersion type temperature sensor in position, complete all as specified and as directed.
Supply and filling refrigerant gas R-22 for 11/30/40/52 TR AC Plant, complete all as specified and as directed. Note: Refrigerant Gas brought by the contactor at site from authorised dealer/manufacturer and shall be in company's sealed cylinder and empty cylinder shall be returned to the contractor.
Supply and filling refrigerant gas R-407 for 45/50/75 TR AC Plant, complete all as specified and as directed. Note: Refrigerant Gas brought by the contactor at site from authorised dealer/manufacturer shall be in company's sealed cylinder and empty cylinder shall be returned to the contractor.
Checking of leakage in condensor of capacity 11/30/40/45/52/75 TR AC Plant, copper piping with the help of full pressure of Nitrogen gas to check the leakage pipe and repairing/blocking of leakage condensor pipe with the help of copper brazing or block the leakage pipe and testing of complete condensor system after completion to the satisfaction of Engr-in-charge complete all as specified and directed. Note: (a) Tools & Plant and tripod etc. required for the above work will be arranged by the contractor at no any extra cost. Rate quoted by the contractor is deemed to be included in the above item. (b) The unit rate quoted are inclusive of the cost of Nitrogen/ CO2 gas used for leakages test and pressure test prior to filling/ charging of gas.
Supply and filling only compressor POE oil including draining out complete existing oil, vaccum testing and labour for filling oil (non freezing) in AC plant complete all as specified and directed. Note: Compressor oil shall be brought by the contractor in sealed cans procured from the authorised dealer.
Supply and fixing in repairs water pressure gauge with 'S' type stainless steel with 15mm gun metal ball valve, complete all as specified and as directed.
Supply and fixing in repair water temperature gauge in position, complete all as sapecified and as directed.
Supply and fixing in repair relief valve in position, complete all as specified and as directed.
Supply and fixing thermal insulation 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously, complete all as specified and as directed.
Opening & dismantling of microproccesor unit of compressor control panel and repairing and re-wiring of the complete control panel with copper cable and lugs as per existing size and gauge of cable, complete all as specified and as directed. Note: 1. The wiring of panal should be done by OEM or authorised dealer of OEM
Supply and fixing in repair contactor model No. 3TF46 with NO+NC of Make Seimens complete all as specified and as directed.
Supply and fixing in repair contactor model No. 3TF34 with NO+NC of make Semens complete all as specified and as directed.
Supply and fixing in repair 3 pole power contactor with (NO+NC) type MNX-70, complete all as specified and directed.
Supply and fixing in repair 3 pole power contactor with (NO+NC) type MNX-50, complete all as specified and directed.
Supply and fixing in repair 3 pole power contactor with (NO+NC) type MNX-32, complete all as specified and directed.
Supply and fixing in repair 3 pole power contactor with (1NO+1NC) type CHNT NC-4011, complete all as specified and directed.
Supply and fixing front mounted add on contact block(1NO + 1NC) for contactors MNX9-80, complete all as specified and directed
Supply and fixing in repair over load protector relay for 3-phase motor max range upto 63 Amp for motor as per existing.
M&L for descaling of condenser header and condenser with the help of pump by rotating the mixture of water and descaling chemical in correct proportions continous till scales are removed, including cleaning of condenser coils with nylon wire brush complete as directed by Engr-in-charge for following capacity of AC plants 11 TR to 180 TR complete plant.
M&L for cleaning and descaling of AHU cooling and heating coil by removing air filters, first with air blower, then with mixture of water and descalin chemical in correct proportion finally washing with plane water complete all as specified and as directed by E-in-Charge.
M&L for cleaning air filiters every month by taking out/down from AHU, first with high speed air blower (to be arranged by contracor ) and then washing the filters with running water till all dust and dirt is removed and refixing after all filters are dried up complete all as specified and as directed.
Dismantling the existing short electric motor including three phase connection from LT panel/motor, cutting the burnt winding and Rewinding of squirrel cage induction electric motor with super enameled copper winding wire using high class insulating materials of the following capacities. :-
M&L for serving by dismantling the existing U/S centrifugal pumps from electric motor including three phase connection from LT panel /motor, Material and Labour for repair of pumps including replacement of bearing, bushes, machining and welding of impellers and casing for repairing erroded portion, repairing of bearing housing, glands etc, including transportation charges, re-fixing and testing after repair for satisfactory performances of the pumps for the following capacities:-
M&L for Repair and servicing of cooling tower draft forced type model No 11 TR to 104 TR capacity AC Plant two times in a season by dismantling of cooling tower for removing of top cover and PVC fills, adjustment of fills with proper way, replacement of rusted nuts, bolts with washers etc and clearing bottom tank to remove mud and dust and painting inner side of the cooling tower with bituminous paint complete all as directed by Engineer-in-charge.
Supply and fixing in repairs fan belt for AHU blowers/Cooling tower motor etc. as per existing make and size complete all as specified and as directed.
Supply and fixing in replacement MCB 32 Amp, 3 Pole, 415 Volt, 50 Hz, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider
Supply and fixing in replacement MCB 50 Amp, 3 Pole, 415 Volt, 50 Hz, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider
Supply and fixing in replacement MCB 63 Amp, 3 Pole, 415 Volt, 50 Hz, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider
Supply and fixing in replacement MCCB 100 Amp, 3 Pole, 415 Volt, 50 Hz, 25 kA, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider Note : MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 125 Amp, 3 Pole, 415 Volt, 50 Hz, 25 kA, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider Note : MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 100 Amp, 3 Pole, 415 Volt, 50 Hz, 25 kA, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider Note : MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 160 Amp, 3 Pole, 415 Volt, 50 Hz, 25 kA, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider Note : MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 160 Amp, 4 Pole, 415 Volt, 50 Hz, 25 kA, with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider Note : MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 200 Amp, 3 Pole, 415 Volt, 50 Hz, 25kA with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider NOTE: MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 250 Amp, 3 Pole, 415 Volt, 50 Hz, 25kA with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider NOTE: MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement MCCB 400 Amp, 4 Pole, 415 Volt, 50 Hz, 25kA with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCCB, complete all as specified and as directed. Make : Havells/L&T/Legrand/HPL/Schnider NOTE: MCCB shall be thermal and magnetic adjustable.
Supply and fixing in replacement electronic timer suitable for star-delta starter by taking out/down unserviceable timer and fixing in position with proper electrical connection all as specified and directed.
Supply and fixing in replacement single phase preventor suitable for star-delta starter by taking out/down unserviceable timer and fixing in position with proper electrical connection all as specified and directed.
Supply and fixing, testing and comissioning in repari/replacement of soloneid coil suitable for micropeocessor of 30/40 TR compressor complete all as specified and directed.
Supply and fixing in repairs coupling for pump motor for 10 to 30 HP complete all as specified and directed.
Supply and fixing in repairs of condensor safety valve for 30/40 TR cap AC plant complete all as specified and directed.
Material and Labour in Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete including dismantling of concrete in ground floors and paving n exc 15 cm thickness (below or above ground level)complete all as specified and directed.
Material and Labour for comprehensive checking, inspection and servicing of chiller unit installed at WSA including checking and rectification of all safety features, microprocessor control setting and HP/LP safety of compressor. Note: 1. Checking, inspection and servicing of chiller unit shall be done by skilled technicians.
Material and Labour for comprehensive checking, inspection and servicing of chiller unit installed at New ATC including checking and rectification of all safety features, microprocessor control setting and HP/LP safety of compressor. Note: 1. Checking, inspection and servicing of chiller unit shall be done by skilled technicians.
Material and Labour for comprehensive checking, inspection and servicing of chiller unit installed at New ATC including checking and rectification of all safety features, microprocessor control setting and HP/LP safety of compressor. Note: 1. Checking, inspection and servicing of chiller unit shall be done by skilled technicians.
Material and Labour for comprehensive checking, inspection and servicing of chiller unit installed at New FMS including checking and rectification of all safety features, microprocessor control setting and HP/LP safety of compressor. Note: 1. Checking, inspection and servicing of chiller unit shall be done by skilled technicians.
Supply and fixing crank case heater for scroll compressor of capacity 11 TR to 13 TR by taking down/out old unserviceable crankcase heater and fitting new crank case heater by doing proper electrical connection from control panel complete all as specified and as directed.
Opening & dismantling of star-delta/DOL starter of electric motor from LT panel and repairing and re-wiring of the complete star-delta/DOL starter with copper cable and lugs as per existing size and gauge of cable complete all as specified and as directed.
Dismantling the existing electric motor including three phase connection from LT panel/motor servicing by cleaning the rotor, varnishing, greasing of bearing and replacement of bearing if damaged of squirrel cage induction electric motor and refixing in position and doing electrical connection of the following capacities. :-
Supply and fixing float valve with flexible rod, rubber seat and ball in position of size 25 mm to 50 mm for cooling tower by removing old unserviceable float valve and fitting new one in position complete all as specified and as directed.
Supply and fixing strip heaters of capacity 3KW by taking out/down existing unserviceable heaters and fitting new ones properly in position including wiring of heaters and testing on completion all as specified and as directed.
Supply and fixing aluminium sprinkler of cooling tower of capacity 50/75/100TR properly in position by taking out/down unserviceable sprinkler and fixing new one and testing on completion all as specified and as directed
Supply and fixing in replacement butterfly valve 80 mm by taking out/down unserviceable one and fitting new on in position complete all as specified and as directed.
Supply and fixing in replacement butterfly valve 100 mm by taking out/down unserviceable one and fitting new on in position complete all as specified and as directed.
Supply and fixing in replacement y-strainer mesh of any size by dismantling y-strainer and removing old mesh and fitting new one complete all as specifeid and as directed.
Supply and fixing motor protection device of make softhard suitable for microprocessor panal of watercooled chiller having capacity 22 TR by taking out/down unserviceable part and reflixing new one with proper electrical connection complete all as specified and as directed.
S&F in replacement PCB card of water cooled scroll chiller of capacity 22TR /37.5TR/52 TR by taking out/diwn unserciceable card and fitting new one by doing proper electrical connection and testing on completion all as specified and as directed by Engr-iniCharge.
Supply and fixing pvc fills suitable for cooling tower of capacity 50/75/104 TR in position by removing old unserviceable fills and fitting new fills properly and testing on completion all as specified and as directed.
Material and Labour for cleaning water tank of cooling tower of capacity 500/1000/1500/2000 Ltr by removing mud deposited at bottom of the tank and cleaning with fresh water complete all as specified and as directed.
M&L for Repirs, Servicing and checking all sefety features including, thermostat, relays safety valve and replace whicher part is defective of hot water Generator 90 KW complete all as specified and as directed.
M&L for Repirs, Servicing and checking all sefety features including, thermostat, relays safety valve and replace whicher part is defective of hot water Generator 48 KW complete all as specified and as directed.
Material and Labour for servicing cooling tower gear box by taking out/down from cooling tower of capacity 50TR and replacing bearing, bush and belt and greasing properly and refixing in position complete all as specified and as directed.
Material and Labour for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
M/s Luxmi Constructions
NATIONAL CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .