Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.8 LAccepted-AOC | 1 | Accepted-AOC OK |
Tender Value
₹14.0 L
EMD Value
₹29,450
Closing Date
31 Jan 2022, 2:00 pmClosed
Ex. Engineer Electrical Najafgarh Zone
SOUTH DELHI MUNICIPAL CORPORAIONOFFICE OF THE EXECUTIVE ENGINEER (ELECT) NGZ ROOM NO -219, II ND FLOOR, ZONAL OFFICE BUILDING, DHANSA STAND , NAJAFGARH, NEW DELHI-110043
Beautification and Fcelifting of water body/park adjoining Rajkiya Pratibha School and near DDA Pocket-2 ,sec-19 Dwarka, New Delhi by providing brick work, steel work, M.S. Grill, interlocking CC paver Block, kerb stone, red sand stone work painting
2022_SDMC_102805_1
EE/Elect/Najafgarh Zone/2021-22/34
Open Tender
Electrical Works
Item Rate
120 days
Najafgarh Zone SDMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹29,450
6 Jan 2023
24 Jan 2022
1 Feb 2022
24 Jan 2022
31 Jan 2022
24 Jan 2022
Amount
Fabrication, supplying, installation and commissioning of LED Bollard Light of MS Sheet i/c Laser cutting, making designe as approved by Engineer Incharge and welding the same and making suitable arrangement for mounting of 6-8 Watt LED Down lighter Lighter i/c PU painted, foundation nut bolt but excluding foundation complet etc. as required
P&F of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to I.S.649/1990 etc as required (a) 3 X 2.5 sq.mm.
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes a) 2X10 SQmm
Supply & erection of 3.5 Meter length (above the ground level) M.S.decorative street light pole having two sections of M.S.Pipe. The inner dia. ,outer dia. & length of bottom section should be 132mmX139mmX1000mm (NS) respectively and of . upper section should be 69mmX76mmX2490mm (NS). The pole should have a circular base plate of dia 268mm and thickness 9.75mm and also an inbuilt junction box having opening & closing door i/c one no. 10 Amp. MCB & neutral link at the bottom section The pole should be PU painted i/c 4 No. 10mm J typefoundation bolt and .25cuM cement concrete (1:3:6) - foundation etc as reqd.
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
SITC of 25 watt LED IP65 post top fitting made of die cast aluminium spigot spun aluminium powder coated Lite top cover and clear acrylic diffuser with high voltage protection low power LED's connected in series and parallel combination with better heat sink arrangement input voltage 160-260 volts AC, 50 Hz AC Supply power factor >0.95, luminious efficacy >100 lumens/watt, CCT 5700°K ±300'K, Surge protection not less than lOKV complete etc as requred
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Providing and laying of HDPE PIPE 40mm outer dia with PN rating 4 by hand/manual method conforming toIS 4984.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eleethoypic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. with rain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shode proof SMC sheet of 3mm as required
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm and ID-51 mm nominal)
SITC of 12 watt LED high efficient Recess mounted Downlighter with pressure die cast alluminium heat sink & PC diffuser in white powder coated finish design as req.A-LUMEN EFFACY >90 lm/watt.,B-PF>.95,C-Rated Voltage =220-240VAC,50Hz.
SITC of 9/12 watt LED bush/spike light(with mounting pipe) with die cast aluminium housing with toughoned glass cover in frame ,mounting bracket provided for aiming the object ,high ingress protection against dust & moisture, corrosion resistant coated and IP-65/66 protection as req.A-LUMEN EFFACY >90 lm/watt.,B-PF>.95,C-Rated Voltage =220-240VAC,50Hz.
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25 mmx75 mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
Supplying and laying of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. confirming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 25 mm dia
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .