Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | Accepted-Technical Admitted |
| 2 | Accepted-Technical | Accepted-Technical Admitted |
| 3 | Accepted-Technical | Accepted-Technical Admitted |
| 4 | Accepted-Technical FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | Accepted-Technical Admitted |
| 5 | Accepted-Technical | Accepted-Technical Admitted |
Tender Value
₹77.7 L
EMD Value
₹1.4 L
Closing Date
20 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
SPECIAL REPAIRS TO CHARIOT WORKUP STATION BUILDING NO P-838 AT INS ABHIMANYU AT NAVAL STATION KARANJA
2025_MES_738401_1
84500-K/E8
Open Tender
Civil Works
Item Rate
270 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.4 L
24 Dec 2025
4 Nov 2025
22 Dec 2025
4 Nov 2025
20 Dec 2025
25 Nov 2025
Material and Labour non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floor over 20 mm thick screed bed in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge
PART I : BLDG WORK Material and Labour for taking out/pumping out contaminated water from water pool of size 25mx10mx3 m and diverting into open drain/area as directed by Engineer-in-Charge complete all as specified and directed by Engr-in-charge. Notes : (i) Dewatering shall be done by suction pump/any mechanical means and disposed by truck mounted trailors to dispose off contaminated water and cost of the same shall deemed to be included in quoted rates. (ii) HIGH PRESSURE CLEANING AND SCRUBBING : Cleaning of walls, ceiling and floor by high pressure water jet mixed with detergent / cleaning agent appropriate for tank cleaning having rotary as well as flat jets for effective cleaning of the nooks, walls and corners and then scrubbing By stain (if required). (iii) VACUUM CLEANING: Wet and dry vacuum cleaning for moping of all dirt particles and residual sludge present in the sumps by industrial vacuum cleaner. (iv) Necessary T & P shall be arranged by the contractor by his own arrangement.
Material and Labour for cleaning the new surfaces concrete with wire brushing and applying water proofing treatment as under:- (i) Apply oil bound bitumen primer @ 0.50 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree Celsius on the prepared dry roof surface. (iii) Laying torch applied APP polymer modified membrane 3mm thick with non-woven polyester mat as reinforcement weighing not less than 3.50 Kg/Sqm with white gravel/mineral finished by thermo fusion process all as described under particular specification (iv) Applying two coats of bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete Notes :- Rates are included for Item No (i) to (iv)
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or micro concrete to bonding old and new cementitious substrates as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C. Make :- TM bond EP of Thermax or Equivalent as approved by GE
Material and Labour for Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
Material and Labour for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush. Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer
Material and Labour for high strength epoxy resin based Injection Grouting, Automatic NRV packers in all surfaces from all access side Distance of injections will be 500 m c/c in matrix pattern until is submerged in dampness of chemical. Injection grouting shall be using two component grouting polymer having low viscosity, high molecular weight, thermosetting to reach very deep pores, voids, cracks and honeycomb in the concrete, specific gravity of which shall be 0.95, pH of 2-4,viscosity of 20-25 sec by B/4 ford cup and having curing time of 30-90 minutes area by suitable gun/pump at required pressure (100 bar to 150 Bar), including cutting of nipples after curing etc and sealing the nozzles with epoxy putty and preparing the surface to match with the existing surfaces complete all as specified and directed. Make :- Carlisle Syntec/Thermax Ltd,/Kryton Build Mat Pvt Ltd/SNI Infratech Pvt. Ltd or equivalent as approved by GE
Material and Labour for welded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material complete all as specified and directed
Material and Labour for providing and fixing welded MS wire mesh with anticorrosive primer applied on inner walls of pool weighing not less than 1 kg/sqm applying and mixing mechanically PP fibre of 12 mm length with Anti-crack strength with 25-30 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair mortar by shotcreting/guniting only complies with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 at the RCC surface mixed with in the ratio of0.33:1:4 with cement and sand mortar and mixed with styrene butadiene polymerized cement mortar modifier or AR for bonding with cementitious mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) @ 2% by weight of cement and as per manufacturer's instructions.)and also applying AR Bonding agent on surface before plastering, make of the Thermax or CIPY Chemicals Ltd/redwop chemicals /IWL Chemicals equivalent of webac chemicals/chemco system .complete all as specified and directed by Engr-in -charge. Notes : (a) Item shall be undertaken by the authorized rep of manufacturer through shotcreting/guniting only. (b) Wire mesh Shall be paid separately under relevant item
Material and Labour for providing fixing welded MS wire mesh weighing not less than 1 kg/sqm and mixing and applying mechanically PP fibre of 24 mm length with Anti-crack strength with Rheoplastic non shrink, corrosion resistant, High strength compound BS66 with integral liquid water proofing admixture 1000L of make Thermax Ltd/ CIPY Chemicals Ltd/redwop chemicals /IWL Chemicals or equivalent of webac chemical/chemco system confirms to IS 2645-2003 having specific gravity 1.1 to 1.2 gm/cc chloride content : Nil as per IS 2645-2003 & resistant, High strength compound on internal floor, shallow bottom of pool and inner walls of pool if required etc, one component cementitious microconcrete thixotropic non shrinkage mucis having compressive strength as Bs 4551-80 thickness of 50mm with 3:1:4 cement mortar and strength (ASTM C 109)-80 Mpa @ 28 days, Tensile strength 2.0N/mm2 @ 28 days (ASTM C 348)- 4 Mpa @ 28 days, Flexural strength 10N/mm2 (ASTM C 348)-11 Mpa @ 28 days, Young's modulus -27 KN/sqmm (ASTM D469), Expansion characteristics (ASTM C 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion -Approx. 0.004 N/sqmm., before pouring micro concrete through shotcreting/guniting only. It is recommended to apply granolithic E-Resin based solvent free concrete bonding agent or AR in accurate proportion with complete homogeneity Mpa at 7 days, Tensile strength (BS 6319 pt.7)- 15 Mpa at 7 days, Bond strength (ASTM C 881)- 11 N/sqmm at 7 days, having an over lay time of 03 hrs at 30 C. complete including all tools and tackles as directed by Engr-in-Charge. Note: - Rate quoted shall include for necessary scaffolding required in the item. Make—thermax/ IWL India LTD/STP Ltd webac chemicals/chemco system. Note :- Item shall be undertaken by the authorized rep of manufacturer through shotcreting/guniting only.
Material and Labour for curing of the surface using wax based concrete curing compound curing efficiency; Make of -MaxCure CC of Thermax/IWL/chemco system/webac chemicals/ CIPY Chemicals Ltd/redwop chemicals /Redwop chemicals etc compound complies with the internationally recognized ASTM C309-90 standards including all tools and tackles. Complete all as specified and directed by Engr-in-charge. Note :- Item shall be undertaken by the authorized rep of manufacturer. .
Material and Labour for applying a waterproofing agent with holding the quality of negative hydrostatic pressure on new plastered surface also meeting the elasticity modules as follows 28 days 14000-16000 N/mm2 adhesion to substrate 1 day 0.6N/mm2 28 days 1.3 N/mm2 compressive strength 1 day 12N/mm2 28 days 36N/mm2 flexural strength 1 day 3.6N/mm2 28 days 8.2 N/mm2, modified with special additives and ready to use. Make : Thermax/chemco systems/webac chemicals/IWL CHEM/CIPY Chemicals Ltd/redwop chemicals. .Mixed with water ,it cures forming a coating , with limited thickness which resists the penetration of water to achieve compressive strength of 36 N/mm2 in 3 days, adhesion bond strength of 8.2 N/mm2. Coating to be applied after proper surface preparation to remove loose dust , dirt etc. Cleaning, mixing using slow speed electric drill and application of 2 coats. Complete as per specification. Note :- Item shall be undertaken by the authorized rep of manufacturer.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of RCC as in slab beam chajja (other than ground floor) beams staircase and similar all as specified and directed by Engr-in-Charge
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MoD land, complete all as specified and as directed by Engr-in-charge. Notes :- 1. Taking down earthing strips incl insulators from roof for treatment and re-fixing of same with existing specification in the same position after laid APP membrane including replacement of broken insulators, PVC rawl plus & screws etc are deemed to be inclusive of rate quoted by the contractor. 2. Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work. 3. APP work shall be carried out on PENT RCC roof at 12 -15 mtr height (non accessible roof).
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Material and Labour Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engr-in-Charge. Note:- Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Material and Labour for Mild Steel TMT bar of 5mm and over upto 10mm dia in or stirrups, spacers and binders of designed diameter in various structural elements like column ,beams and foundations including drilling ,bending, welding and fixing the bars with epoxy putty etc. (Steel provided on the basis of 1% of volume of concrete).
Material and Labour for 40 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in SUB-FLOORS, SUB-BASES, FLOORS AND PAVINGS, ETC including WPC by weight of 3% of total cement content complete all as specified and directed
Material and labour for cement concrete type D-2 1:4:8 using 40mm graded crushed stone aggregate as in foundations, fillings & mass concrete etc all as specified and directed.
Material and Labour RCC (1:2:4) type B-1, using 12.5 mm graded mechanically crushed stone aggregates for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and Chajjas complete all as specified and directed.
All as per item No 81.00 here-in-before but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board, complete all as specified and directed by Engr-in-charge.
Supply and Fix vitrified finger grip tile any size and thickness 8mm of rounding of corner, Junction avoiding sharp edges Standard on in swimming pool approved manufacturer and specified shade like Orient Blue / Dark Blue /new blue etc. laid in approved pattern on 3-6 mm ( 5mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal endura gold star / letecrete / Rock force) in conjunction with polymer modified liquid Bal endura admix Adlor equivalent product of letercrete / Rock force mixed in required proportion as specified by manufacturer including filling / scaling of joints 2-3 mm thick between the tiles with epoxy grout of Bal endura epoxy grout / Letecrete / Rock force with matching colour pigment to make it water tight and finished neat complete all as specified and as directed by Engineer-in-Charge
Material and Labour for factory made Heavy Duty Non skid endura tile ultra strong in digital pattern of size 300mm x 300mm thickness of tiles 08 to 10 mm, set, jointed and pointed in near cement slurry in floors, with grey cement and pigments and laid over & including 15 mm thick screed bedding in CM 1:6 complete all as specified and as directed by Engineer-in-Charge
Material and Labour Hand cut Kota stone slab flooring 20-25mm thick over cement screed base laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & mirror polishing including 20mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed by Engr-in-charge.
Material and Labour Hand cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement including rubbing & mirror polishing including 10mm thick rendering in Cement Mortar 1:4 complete all as specified and directed by Engr-in-charge.
Supply , laying, testing and commissioning of MS ERW pipe class 'B' in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 100 mm bore, complete all as specified and directed by Engr -in- Charge.
Material and Labour non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in skirting/dado over 10 mm thick cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
Supply and Fix green marble 16-18 mm thick machine cut, jointing and pointing with white cement slurry including 20mm thick screed bed or bedding layer of mortar in CM 1:6 including dismantling of old stone slab / tiles complete all as specifie
d and directed.
Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand cushion for maintain camber and slope all as per directed by Engr-In Charge. Note:- Sand Cushion will be paid separately under relevant item of this schedule.
Material and Labour for 60 mm thickness Machine pressed precast concrete inter locking paver block glazed coloured upto 6mm on top in any shape and size , strength not less than M-35 Grade all as directed by Engr-in-charge
Material and Labour Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engr-in-Charge.
Supply and Fix rolling shutter without ball bearing, thickness of laths 1.00mm as specified including top cover, anchoring rod, hasp and staple, gear operated type with chain wheel and hand chain and primer erected in position including taking down of old Shutter as directed.
Supply and Fix in repair to stainless steel 304 grade framed work fancy/ornamental type in Gates/ stair hosing work and other similar works including all or any type of welding, holdfast, locking arrangement, followed by buffering and polishing for smooth finish including taking down of old SS Railing/pillars complete all as specified and as directed by Engr-in-Charge.
Supply and Fix for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles including connected items, with and including making good to the disturbed portion with its original specifications complete all as specified and directed.
Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutter area n. exceeding 0.50 Square Metre each pane complete all as specified and as directed.
Supply and Fix 4 mm thick sheet glass, ordinary quality ,fixed in aluminium Door /window shutter area . exceeding 0.50 Square Metre each pane complete all as specified and as directed.
Supply and Fix for concealed star lock powder coated for aluminium window fixed as per manufacturers instructions complete all as specified & as directed.
Supply and Fix aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Supply and Fix for rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors etc complete all as specified and as directed.
Supply and Fix of aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed. Make- Deco grill or equivalent
Supply & fixing of framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls including dismantling to existing framework as directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Material and Labour for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width in type B1 (1:2:4) (20mm graded stone aggregate )and setting in mortar (1:6) including demolition of old PCC Block complete all as specified and as directed
Material and Labour for ready mix plaster for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.
Material and Labour for ready mix plater for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specified. (Note:- Item rate shall be include any height of Bldgs for scaffolding as all arrangement.)
Material and Labour for ready mix plaster for rendering 5 mm thick on ceilings in cement mortar 1:3 and finishing the surface even and smooth without using extra cement complete all as specified.
Material and Labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed
Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed
Material and Labour applying 3mm thick wall care putty on newly plastered surface and prepare the smooth surface with sand paper and applying two coats of oil bound distemper on walls/Ceiling complete all as specified and as directed by Engineer-in-Charge
Material and Labour for new or old external wall surface by wire brushing/grinding in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with mechanical water nozzle with clean water & allow to dry. Fill visible cracks/ joints by crack seal compound and epoxy base joint filler including resin and hardener in proportion as per manufactures instruction & allow to dry for 24 hours. Apply one coat of water base primer (with mechanically airless paint sprayer machine) and allow to dry for 6 hours appx. Thereafter apply 02 coats of WB high build anti carbonating coating cum waterproofing (with mechanically airless paint sprayer machine) & match with brush at the interval of 08 hours between the coat and allow to dry to match the existing shade in camouflage pattern including or plain paint necessary scaffolding necessary security for the workers for any height, covering etc complete all as per specified and directed. Note:- External water proofing treatment on wall at any height of the building including acrylic paint shall be applied by mechanically Airless paint sprayer machine only.
Material and Labour Formwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular in plan to provide rough finish surface to concrete
Material and Labour Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.with rough finished surface
Material and Labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and directed
Material and Labour for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately.
Supply , laying, testing and commissioning of MS ERW pipe class 'B' in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 80 mm bore, complete all as specified and directed by Engr -in- Charge.
Material and Labour for rendering 10mm thick in cement mortar 1:4 on roof top surface including WPC as per manufacturer instructions complete all as specified and as directed. Note : WPC will be measured separately
Material and Labour for applying chemical compound with dispersing agents Removing (and not damaging the beneath brick or RCC surface) old existing unserviceable concrete, cement plaster, loose / unsound weaken cement of any description and in any position from existing external / internal surfaces of walls, or any surface average depth 5-25mm (Approx height/depth 4.5 m from natural ground level) with concrete removing agent(except for zinc and galvanised metal) and clean the treated surface immediately after removal treatment, and removal up to the approval municipal dumping grounds specified by the local bodies outside the premises including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale/ rust etc from the visible unplastered surface
Each Pair
Material and Labour for cutting 'U' shaped grove carefully by diamond cutter, breaker etc without damaging the structure in RCC members i.e. internal surface, of size approx 37mm (depth) x 25mm (width) along the constructions joints and other surfaces as directed and filling the 'U' grove with Patch N plug of or equivalents in make AQUACREAT and PIDILITE over and including application of crystalline concrete slurry @ 0.04 kg/RM in the grove by brush application and allow to dry for 10 minutes as per manufacturers instructions complete all as specified and directed. Notes :- (a) Cost of providing scaffolding shall deemed to be include
Supply and fix Cable with copper conductor 10sqmm 2 CORE PVC round sheathed (flexible) industrial cable saddle on wall surface including all accessories complete all as specified and directed by Engr-in-charge. ( for security light)
Material and Labour for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.5 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm dia by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Note : The unit rate includes for protection pipe and lead wire from top of earth plate up to 7.5 meter above ground level.
Supply and fix Foot Valve conforming to IS 4038, 80 mm (3”) dia, complete all as specified and directed by Engr -in- Charge.
Supply and fixing sluice valve with flanged ends 100 mm bore cast iron body, flanged and drilled end no
n rising type , bronze spindle with nuts, as per IS 14846, ISI marked including all joints, class PN 1.6, complete all as specified and directed by Engr -in- Charge.
Supply and fixing butterfly valve with matching flanges, gasket, all as specified and directed of 80 mm dia, complete all as specified and directed by Engr -in- Charge.
Supply and fixing in repair Non return valve (reflux valve) with by pass arrangements complete of size 100 mm dia with matching flanges, gasket, complete all as specified and directed by Engr -in- Charge.
Supply and fixing in repair Non return valve (reflux valve) with by pass arrangements complete of size 80 mm dia with matching flanges, gasket, complete all as specified and directed by Engr -in- Charge.
Supply and fix direct cylinder mounted type vacuum chlorinator for pressure feed including all gauges, pump, motor conforming to IS 10553 part - 2 having capacity 1.0 to 1000gm/hr, complete all as specified and directed by Engr -in- Charge.
Material and Labour for PVC Piping and Fittings for the ozonator to Filter to Pool inside the pump room with necessary pipings and control valves. Pipings in PVC 10 Kg Pressure, complete all as specified and directed by Engr -in- Charge.
Supply and fixing of Centrifugal horizontal Monoblock pump set 3 phase 440 Volt star delta starter capacity 7.5 HP flow rate 25 GPM at 5.5 Mtr head complete with chassis (MS) for mounted the pump set and PCC foundation nut bolt etc . also all consumable connected fitting required at site including this quoted rate, complete all as specified and directed by Engr -in- Charge.
d in quoted rates. (b) Structural treatment to be executed through authorised applicator of manufacturer as approved by GE.
Supply and fixing CPVC pipe line size 80 mm dia in center of swimming pool for inlet water with complete fitting such as elbow nipple socket nut bolt etc. all as specified and directed by Engr -in- Charge.
Taking down Exhaust fan and keeping in safe custody for reuse and refixing the same after duly painted and marking of MES number on ceiling fan of size 1200mm sweep complete with connected accessorie
Supply & fixing floor inlet nozzles are installed on the bottom floor of the swimming pool which provides water to the pool, complete all as specified and directed by Engr -in- Charge. These floor inlets allow efficient water flow adjustments to desired level.
Material and Labour for preparation of surface and applying 12.5mm thick fully consolidated rapid setting cementitious material with setting time 10 mins max @ 25kg/1.05 sqm by low pressure spray equipment or with trowel for patching and resurfacing of deteriorated concrete to produce superior bond low shrinkage, chemical durability and high strength mixed with water at site as per manufacture instructions/ specifications, initial setting time 3.25 hrs and final setting time 5.00 hrs with compressive strength 53 MPA in 28 days, as per manufacture instructions complete all as specified and directed by Engr-in-charge. Notes :- (a) Cost of providing scaffolding shall deemed to be included in quoted rates. (b) Structural treatment to be executed through authorised applicator of manufacturer as approved by GE.
Per point
Point
Material and Labour for point wiring with 1.5 sqmm (nominal area) FRLSH PVC insulated and sheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) concealed on wall surface with all accessories including 1.5 sqmm size PVC insulated sheathed copper conductor multistranded cable FRLSH for continuous earth conductor ( using green colour) to common earth and connecting to earth dolly, complete all as specified and directed by Engr-in-charge for the following :- (a) One light / Buzzer point controlled by one switch 5 Amp, SP, one way 240 volts. Note :- Necessary cutting and chasing of wall surface including making good surface deemed to be included in quoted rates.
(b) One fan/exhaust fan point controlled by one switch
s as directed and specified by Engr-in-Charge.
(c) One 5 pin socket outlet 5 Amps on same board
(d) One 5 pin socket outlet 5 Amps on independent board
Supply and fix switch 6 amp one way ISI marked complete all as specified and directed.
Supply and fix switch socket combination 15/16 amp one way complete all as specified and directed.
Supply and fix socket 5/6 amp one way complete all as specified and directed.
Supply and fix step type fan regulator 120 Watt ,220 volt ,50 Hz ISI marked complete all as specified and directed.
Supply and Fix ceiling rose, 3 phase/PVC/polycarbonate, isolated body, three terminals complete all as specified and directed.
Supply and fixing surface and wall mounted LED batten of 20/22 W with polycarbonate housing & integrated electronic driver having THD<20%, complete all as specified and directed by Engr-in-charge.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and Fix in repair/replacement 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
Supply and Fix in repair/replacement SPN 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
Material and Labour for wiring for circuits/sub main wiring with FRLSH PVC insulate sheathed 2 x 6 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into concealed PVC conduit with 6 sqmm FRLSH PVC insulated green copper cable for continues earth with suitable dia of PVC pipe with all accessories complete all as specified and directed by Engr-in-Charge.
Material and Labour for wiring for circuits/sub main wiring with FRLSH PVC insulate sheathed 2 x 4 sqmm stranded copper conductor cable 1100 volts grade heavy duty drawn into concealed PVC conduit with 4 sqmm FRLSH PVC insulated green copper cable for continues earth with suitable dia of PVC pipe with all accessories complete all as specified and directed by Engr-in-Charge.(for geyser point)
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, concealed on wall including taking out old unserviceable MCB DB any size/type.
Taking down of submain of any size, complete all as specified and directed by Engr-in-charge.
Taking down ceiling fan and keeping in safe custody for reuse and refixing the same after duly painted and marking of MES number on ceiling fan of size 1200mm sweep complete with connected accessories as directed and specified by Engr-in-Charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED complete all as specified and directed by Engr-in-charge.
PART III : ELECTRIC SUPPLY WORK Taking down carefully copper /aluminium point wiring ( light, fan, socket or power) complete, with wiring accessories such as bend boards Elbows only, ceiling fittings etc and removing material to store for safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engr-in-charge.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
SOC84500.pdf
Additional Documents • 0.01 MB
BOQ_826797.xls
BOQ • 0.45 MB
Tenderdocuments84500.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .