Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAdmitted-Finance | ₹3.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.1 Cr+₹79.3 L (23.7%)Admitted-Finance | ₹4.1 Cr+₹79.3 L (23.7%) | L2 | Admitted-Finance |
| 3 | L3₹4.8 Cr+₹1.4 Cr (42.8%)Admitted-Finance OFFICE NO 208 B WING 2ND FLOOR GROMA HOUSE PLOT 14C SECTOR 19 VASHI NAVI MUMBAI VASHI NAVI MUMBAI MAHARASHTRA 400705 UDYAM MH 19 0041442 | THANE | MAHARASHTRA | 400705 | ₹4.8 Cr+₹1.4 Cr (42.8%) | L3 | Admitted-Finance |
| 4 | L4₹4.8 Cr+₹1.5 Cr (44.4%)Admitted-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹4.8 Cr+₹1.5 Cr (44.4%) | L4 | Admitted-Finance |
| 5 | L5₹4.9 Cr+₹1.5 Cr (45.3%)Admitted-Finance 5TH FLOOR NEHERU NAGAR WAGLE INDUSTRIAL ESTATE THANE WEST THANE MAHARASHTRA 400604 | THANE | MAHARASHTRA | 400604 | ₹4.9 Cr+₹1.5 Cr (45.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ADISHWARAM CORPORATION L6 | Yogiraj Powertech Pvt Ltd. L3 | Konstelec Engineers Pvt. Ltd. L2 | EVERCREST PROJECTS PVT LTD. L4 | Miraj Instrumentation Services I Pvt. Ltd. L5 | NEWADARSH INFRAWORKS PVT LTD L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.0022KV Switchgear Panel | |||||||||
| 1.10 | Supply, Transportation to site, Installation, Testing and Commissioning of 22 kV Switchgear panel set as per Clause No. 1 of Specification | 1 | SET | 2,09,84,195 ₹2,09,84,195 | 1,78,01,712 ₹1,78,01,712 | 1,53,18,760 ₹1,53,18,760 | 1,61,08,919 ₹1,61,08,919 | 1,79,52,924 ₹1,79,52,924 | 1,35,07,166 ₹1,35,07,166 Lowest |
| 2.0011KV Switchgear Panel | |||||||||
| 2.10 | Supply, Transportation to site, Installation, Testing and Commissioning of 11 kV Switchgear panel set as per Clause No. 2 of Specification | 1 | SET | 84,06,320 ₹84,06,320 | 56,19,483 ₹56,19,483 | 51,49,520 ₹51,49,520 | 54,83,871 ₹54,83,871 | 77,74,371 ₹77,74,371 | 44,08,976 ₹44,08,976 Lowest |
| 3.00LT Switchgear Panel | |||||||||
| 3.10 | Supply, Transportation to site, Installation, Testing and Commissioning of LT Switchgear panel set as per Clause No. 3 of Specification | 1 | SET | 3,15,21,993 ₹3,15,21,993 | 1,85,42,958 ₹1,85,42,958 | 1,58,48,796 ₹1,58,48,796 | 2,17,76,862 ₹2,17,76,862 | 1,41,57,904 ₹1,41,57,904 | 1,19,05,900 ₹1,19,05,900 Lowest |
| 4.0022 kV End termination of cable | |||||||||
| 4.10 | Supply, installation, testing and commissioning of end termination of following 22 kV 3C x 300 sq.mm XLPE cable (Indoor) using heat shrinkable termination kits as per Clause no. 4 of specification. | 16 | Nos. | 30,806 ₹4,92,896 | 30,963 ₹4,95,408 | 23,890 ₹3,82,240 | 17,105 ₹2,73,680 | 22,735 ₹3,63,760 | 12,660 ₹2,02,560 Lowest |
| 5.0011 kV End termination of cable | |||||||||
| 5.10 | Supply, installation, testing and commissioning of end termination of following 11 kV 3C x 400 sq.mm XLPE cable (Indoor) using heat shrinkable termination kits as per Clause no. 5 of specification. | 9 | Nos. | 26,032 ₹2,34,288 | 28,427 ₹2,55,843 | 13,353 ₹1,20,177 | 12,182 ₹1,09,638 | 20,580 ₹1,85,220 | 9,960 ₹89,640 Lowest |
Tender Value
₹3.5 Cr
EMD Value
₹7 L
Closing Date
28 Sept 2022, 6:00 pmClosed
Chief Engineer and Head, TSD
Chief Engineer and Head, Technical Services Division, BARC, Trombay, Mumbai 400085
Power Supply up gradation of 11KV system and other associated electrical works at RCnD and IRE Sub Stations in BARC, Trombay, Mumbai 400085
2022_BARC_705361_1
BARC/TSD/47/2022-23
Open Tender
Electrical Works
Item Rate
550 days
BARC, Trombay, Mumbai
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹7 L
TSD, BARC, Trombay mumbai
17 Nov 2022
10 Aug 2022
30 Sept 2022
10 Aug 2022
28 Sept 2022
10 Aug 2022
10 Aug 2022 - 26 Aug 2022
24 Aug 2022
Amount
22KV Switchgear Panel
Supply, Transportation to site, Installation, Testing and Commissioning of 22 kV Switchgear panel set as per Clause No. 1 of Specification
11KV Switchgear Panel
Supply, Transportation to site, Installation, Testing and Commissioning of 11 kV Switchgear panel set as per Clause No. 2 of Specification
LT Switchgear Panel
Supply, Transportation to site, Installation, Testing and Commissioning of LT Switchgear panel set as per Clause No. 3 of Specification
22 kV End termination of cable
Supply, installation, testing and commissioning of end termination of following 22 kV 3C x 300 sq.mm XLPE cable (Indoor) using heat shrinkable termination kits as per Clause no. 4 of specification.
11 kV End termination of cable
Supply, installation, testing and commissioning of end termination of following 11 kV 3C x 400 sq.mm XLPE cable (Indoor) using heat shrinkable termination kits as per Clause no. 5 of specification.
Straight Through joint of 11KV
Supply, installation, testing and commissioning of end termination of Straight Through joint of 11KV 3C x 400sq.mm XLPE Cable as per Clause 6 of specification
Only Installation of LT Control Cable
Only installation of Control cable (upto 35mm dia) as per Clause No.7 of specification.
End termination of LT control cable: Supply, installation, testing and commissioning of end termination of following 1.1KV XLPE cable as per Clause No. 8 of specification
10 core x 2.5 Sq.mm Cu. Conductor control cable
4 core x 2.5 Sq.mm Cu. Conductor control cable
10 core x 4 sq mm cu conductor control cable
4 core x 4 Sq.mm Cu. Conductor control cable
Earth station
Supply, installation, testing and commissioning of copper plate earth station as per Clause no 9 of specification.
Copper Earthing conductor: Supply, installation, testing and commissioning of copper conductor of the following sizes on wall / ceiling / RCC trench / cable support as per Clause no. 10 of specification.
50 mm X 6mm Cu strip
32 mm X 6mm Cu strip
25 mm X 6mm Cu strip
22KV XLPE Cable
Only Installation, testing and commissioning of 22 kV 3C x 300 sq.mm XLPE cable as per Clause no. 11 of specification.
HT Cable handling and rerouting of Cable
Cable handling and rerouting of 22 kV Cable as per Clause no 12.1 of Specification
Installation/Re-routing of 11KV 400sq.mm XLPE Cable as per Clause No 12.2 of technical specification
Supply & Installation of IRDD (Automatic Rack-in & Rack-out trolley) as per Clause No 13 of specification
MS Items
Fabrication, Supply and installation of cable/panel supports using MS angles /MS channels/ flat for cable support/base frame etc. as per Clause No. 14 of specification.
Fabrication, Supply and installation of MS trench covers as per Clause No. 14 of specification.
Excavation of the following type of soil as per Clause No.15 of specification.
Hard rock: Cutting of RCC wall/RCC floor/Core cutting shall be measured against this item.
Soft: Cutting of Soft soil/Road/Murram shall be measured against this item
Supply and installation of 1:2:4 PCC work as per Clause No.16 of specificaiton
Insulating Floor Mat: Supply & installation of insulating mates as per Clause No. 17 of specification
Class C, 33 kV
Class B, 11 kV
Battery Bank
Supply, installation testing and commissioning of 110V, 100AHr Battery Bank (VRLA type) as per Clause No. 18 of Technical Specification
Battery Charger.
Supply,installation testing and commissioning of 110V, 40A Float & Float cum Boost mode Battery Charger suitable for 110V, 100AHr Battery Bank as per Clause No. 19 of Technical Specification
LT End termination of cable: Supply, installation, testing and commissioning of end termination of following sizes of cable (Indoor) using heat shrinkable termination kits as per Clause no. 20 of specification.
3.5C x 400 sq.mm LT XLPE Cable
3.5C x 300 sq.mm LT XLPE Cable
3.5C x 240 sq.mm LT XLPE Cable
3.5C x 185 sq.mm LT XLPE Cable
1C x 630 sq.mm LT XLPE Cable
Dismantling, Removal & Shifting of following existing panel/Battery cells/Battery charger as per Clause No 21 of specification
Removal of 22 kV Panel from IRE substation of size approximately 13000X2300X2300 mm (WXHXD)
Removal of exisitng 11KV Switchgear Panel from RCnD Sub-Station of size approximately 9000X2400X2400 mm (WXHXD)
Removal of exisitng LT Switchgear Panel from RCnD Sub-Station of size approximately 8700X1400X2400 mm (WXHXD)
Removal of existing Battery Bank (15 cells of 2V, 100AHr of YKP-9 of EXIDE make) from RCnD Sub-Station
Removal of existing Battery Charger and DC to DC converter from RCnD Sub-Station
Removal of existing RTCC panel from RCnD Sub-Station
Konstelec Engineers Pvt. Ltd.
Yogiraj Powertech Pvt Ltd.
EVERCREST PROJECTS PVT LTD.
Miraj Instrumentation Services I Pvt. Ltd.
ADISHWARAM CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 12.23 MB
Proforma_of_schedules_BARC_TSD_47_2022_23.pdf
Tender Documents • 0.65 MB
SCHEDULE_A_BARC_TSD_47_2022_23.pdf
Tender Documents • 0.62 MB
Approvalletternit47.pdf
Tender Documents • 0.40 MB
BOQ_742111.xls
BOQ • 0.23 MB
Tender_document.pdf
Tender Documents • 2.10 MB
TECHNICAL_BID_BARC_TSD_47_2022_23.xls
Tender Documents • 0.29 MB
TSD47_Tender_Specs.pdf
Tender Documents • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .