Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC | ₹3.9 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.9 Cr+₹1.8 L (0.47%)Rejected-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | ₹3.9 Cr+₹1.8 L (0.47%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹4.1 Cr+₹29.2 L (7.59%)Rejected-AOC | ₹4.1 Cr+₹29.2 L (7.59%) | L3 | Rejected-AOC Not lowest |
| 4 | L4₹4.2 Cr+₹35.0 L (9.08%)Rejected-AOC 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹4.2 Cr+₹35.0 L (9.08%) | L4 | Rejected-AOC Not lowest |
| 5 | L5₹4.4 Cr+₹52.6 L (13.7%)Rejected-AOC | ₹4.4 Cr+₹52.6 L (13.7%) | L5 | Rejected-AOC Not lowest |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
21 Mar 2020, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
PROVN OF 02 X OFFRs MESS AND ALLIED WORKS FOR CERTAIN UNITS AT TIBRI MIL STN UNDER GE GURDASPUR
2018_MES_187081_2
80966/E8
Open Tender
Civil Works
Lump-sum
365 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Gurdaspur
₹4.8 L
Yes
25 Jun 2020
10 Dec 2019
23 Mar 2020
10 Dec 2019
21 Mar 2020
29 Feb 2020
10 Dec 2019 - 14 Mar 2020
Amount
Note: Please refer Schedule 'A' Notes given on serial page No. 27(R) , 28 to 31 of tender documents for all Sch 'A' Part-I to XVII
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 32(R)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 34(R)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS Schedule 'A' Part-III brought forward from serial page No. 35 (R )
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 37(R )
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT & HARDSTANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 39(R)
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 40 (R)
Lump sum price worked out by the contractor for COMPOUND WALL, FENCING & GATE WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 42 (R)
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 43(R)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 47(A)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 49(R)
Lump sum price worked out by the contractor for SOLAR WATER HEATING SYSTEM WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 50 (A)
Lump sum price worked out by the contractor for SUMMER APPLIANCES as listed in Schedule 'A' Part-XII brought forward from serial page No. 51(R)
Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS listed in Schedule 'A' Part-XIII brought forward from serial page No. 53 (R)
Lump sum price worked out by the contractor for ARBORICULTURE WORKS listed in Schedule 'A' Part-XIV brought forward from serial page No. 55(R)
Lump sum price worked out by the contractor for PCC HARD STNDING listed in Schedule 'A' Part-XV brought forward from serial page No. 56(R)
Lump sum price worked out by the contractor for TREE CUTTING listed in Schedule 'A' Part-XVI brought forward from serial page No. 56(A)
SCH 'A' PART-XVII MISC ITEMS Lump sum price worked out by the contractor for Misc Items of Works listed in Schedule 'A' Part-XVII
INTERNAL ELECTRIC SUPPLY WORKS
Material & labour for concealed point wiring complete with 1.5 Sqmm (nominal cross sectional area) FR PVC insulated multi-stranded copper conductor cable in and including medium grade PVC conduit pipe (ISI marked) including 1.5 Sqmm FR PVC copper conductor cable multi-stranded in green colour code as earth wire connected to the common earth dolly as specified for one light point/ fan point/ exhaust point controlled by one switch. Note : Modular Flush boxes and modular white cover with frame shall be measured and paid seprately
All as per srl item No 3.01 here-in-before but one three pin socket outlet 5 Amp on independent board complete all as specified.
All as per srl item No 3.01 here-in-before but one three pin socket outlet 5 Amp on same board complete all as specified.
All as per srl item No 3.01 here-in-before but one light point controlled by two 2 way switches complete all as specified.
All as per srl item No 3.01 here-in-before but with 2.5 Sqmm copper cable and 2.5 Sqm copper conductor cable in green colour code as earth wire for 15 Amp socket outlet complete all as specified and directed.
All as per srl item No 3.01 here-in-before but with 1.5 Sqmm copper cable and 1.5 Sqm copper conductor cable in green colour code as earth wire for four Socket /light controlled by one switch complete all as specified and directed. Note for Item No 3.01 to 3.06 :- Socket , switch, sunk metal boxes, and complete with frame shall be measured and paid for separately
M&L for telephonic connection with modular type piano type telephone socket with concealed conduit and telephone cable GI wire 6/2, 0.50mm dia for one pair telephone upto external wall of bldgs PVC insulated, PVC sheathed unarmoured and annealed tinned conductor with tape threaded complete all as specified
Supply and fixing modular metal flush box of 8 module complete all as specified and directed.
Supply and fix modular dummy plate complete all as specified.
Supply & fixing modular type ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified
Supply & fixing lamp holder metal ring for modular fittings including LED lamp 8W 220-240V 50Hz complete all as specified
Supply & Fixing ceiling fan of 1200 mm sweep BEE 5 star rated and long lasting metallic paint finish complete and provn of cord flexible copper conductor three core from connector to ceiling rose with provn of fan hook etc complete all as specified.
Supply and fix exhaust fan heavy duty with louvers complete of 300mm size corrosion less, double ball bearings with louvers with bolts,nuts and washers ,size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified. Note. : Necessary cost of opening in wall and grouting of mild steel work shall be deemed to be included in the lump sum cost of the building.
Supply and fix PVC exhaust fan with auto close louvers of size 150mm dia complete with all standard fittings and accessories as per manufacturer's instructions complete all as specified and directed. Note : Cost of opening in wall and grouting of mild steel work shall be deemed to be include in the lumpsum cost of building
Supply and fix energy efficient, enviornment frinendly, LED tube light fittings surface/ pendent mounting complete with white powder coated slim box batten of formed CRCA with snap on installers suitable for 1200mm long T8 tubular LED lamp including linear 1X20 Watt LED tubular lamp with extruded PC body and opal diffuser ,inbuilt driver ,220-240 V, 50 Hz, 6000K for white illumination including surge protection device all accessories and connection from ceiling rose to connector complete all as specified and directed.
Supply and fixing energy efficient LED enviornment friendly LED security light B1 class made up of pressure die cast aluminium housing with high power LED as lighting source and lense embedded for area/ path illumination as per National Lighting Code (SP 72:2010) by using security light of 25 watts (total input power), CCT - 5000- 5500K CRI > 67, PF > 0.95, rated output lumens2100 Im, operating performance temp - 10 degree centigrade + 45 degree centigrade LED module life span 50000 burning hrs, with toughened glass, external surge and over voltage protection device up to 440V alongwith connection 3 core copper flexible cable of size 0.75 sqmm to be provided with weather proof connector, LED module & driver IP-66 rated duly ISI marked IS:16103 part (1&2) 2012 : efficency 85% constant current Vtd < 10%, lthd < 15% complete with 40mm dia GI pipe light grade 1.5 mtr long bracket and FI 40 x 6 mm clamp 2 Nos with nut bolts etc including painting of clamps with two coats of aluminium paint over a coat of primer (for bldg security lights) complete all as specified.
Supply and fix energy efficient, enviornment frinendly, linear and compact surface/pendent mounted LED mirror light fitting complete with white powder coated slim box batten of formed CRCA with decorative end caps suitable for 300mm long tubular LED lamp including linear 1X9 Watt LED tubular lamp with extruded PC body and opal diffuser ,inbuilt driver ,220-240 V, 50 Hz, 6000K for white illumination including surge protection device all accessories and connection from ceiling rose to connector complete all as specified and directed.
Supply and fix energy efficient, enviornment frinendly,linear and compact ceiling mounted LED porch light fittingIP 54 complete with white powder coated slim box batten of formed CRCA with decorative end caps suitable for tubular LED T8/T5 lamp including linear 1X14 Watt LED tubular lamp with extruded PC body and opal diffuser ,inbuilt driver ,220-240 V, 50 Hz, 6000K for white illumination including surge protection device all accessories and connection from ceiling rose to connector complete all as specified and directed.
Supply and fixing MCB distribution board TPN 4 way with MCCB 100 Amps as incomer double door 415Volt with bus bar neutral link complete all as specified. Note :- 1. MCCB/MCB's to be measured & paid seperately. 2. DB should be suitable for IP-43 protection including provision for reversible door.
Supply and fixing MCB, SPN 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing MCB, SP 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 4 Sqmm and one run of 4 Sqmm for earth continuous earth wire inlcuidng suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 4 sqmm & one runs of earth wire 4 sqmm will be considered as one unit.
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 6 Sqmm and one run of 6 Sqmm for earth continuous earth wire inlcuidng suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 6 sqmm & one runs of earth wire 6 sqmm will be considered as one unit.
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 15mm bore light grade and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.
INTERNAL WATER SUPPLY WORKS
Supply and fixing 15mm bore chromium plated water jet for approved quality to be fixed with EWC complete all as specified
RAIN WATER HARVESTING WOKS
Supply & Fixing nylon mesh complete all as specified & directed
EXTERNAL ELECTRIFICATION WORKS
Supply & fixing of LED street light fixture ≥ 60 W LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individula LEDs must have secondary lenses for better throw across and along the road, with system luminaire efficiency ≥ 100 lumen/ watt, colour rendering index (CRI) of ≥ 70, corelated clour temperature (CCT) of 5700 K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and TD ≤ 10%, operating temperature range from 140 to 270 V the potted driver used shall be constant voltage based and ISI marked all as per BIS-15885 Part-2, Section 13 with efficiency ≥ 85%, make of driver shall be same as the make of fixture complete all as specified and directed. Note : (i) Contractor shall obtain LM 79 & LM 80 test report (from third party NABL Lab only, in house Lab test report will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department for approval. (ii) The manufacturer's LOGO shall be embossed into the housing of luminaire. (iii) Luminaire shall comply with all the above parameters as mentioned in description.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm with & including GI pipe 40mm bore light grade as protection pipe (upto the distribution board) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate, RCC M-25 cover, angle iron frame and necessary earth work complete all as specified with the following :- (a) Test point GI for size 75mm x 75mm x 25mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode upto MS funnel with bras wire mesh embedded in floor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits. (c) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40 x 40 x 4mm angle iron for 30 x 30mm PCC pit for holding the pit cover. Note :- 1. The unit rate shall include for protection GI pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32 x 6mm from the earth plate and upto metallic body of the quipment/ panel board etc. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. RCC pit cover shall be 80mm thick precast RCC M-25 Design Mix reinforced with XPM weighting not less than 4 Kg/sqm in lieu of CI cover.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI earth wire 4mm dia with & including GI pipe 15mm bore light grade as protection pipe (upto the distribution board/DG Set) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate, RCC M-25 cover, angle iron frame and necessary earth work complete all as specified with the following :- (a) Test point GI for size 75mm x 75mm x 25mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode upto MS funnel with bras wire mesh embedded in floor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits. (c) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40 x 40 x 4mm angle iron for 30 x 30mm PCC pit for holding the pit cover. Note :- 1. The unit rate shall include for protection GI pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32 x 6mm from the earth plate and upto metallic body of the quipment/ panel board etc. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. RCC pit cover shall be 80mm thick precast RCC M-25 Design Mix reinforced with XPM weighting not less than 4 Kg/sqm in lieu of CI cover.
Supply and fixing junction box polycarbonate with glass fibre reinforced, environ friendly recyclable UV resistant, silicon free anti acid and anti corrosive IP-66/67 in accordance with IE rule internally ammbeded gasket and one MCB SP 6A, 10A, 02 Nos aluminium bus bar 25 x 3mm fixed to control the street/ post top lntern including necessary clamps, nuts, bolts to fix the junction box complete all as specified and directed.
M&L for brackets using GI tubing light grade 40mm dia 1.5 Mtr long bent to shape suitable for fixing of street light fixed along the pole with necessary clamps etc complete all as specified and directed.
M&L for twin core PVC copper conductor stranded cable of size 1.5 Sqm complete all as specified and directed.
M&L for road cutting for carrying of protection pipe of underground cable, including excavation returning filling in, spreading leveling, well ramming in layers, soiling with, broken boulders/ stones, WBM 7.5cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25mm thick using ready mate material, rolled & compacted for road patch repair work section/ cross section area of cutting complete all as specified and directed. Note : Average width of road 0.45m & average depth of road1.0m for road cutting will be considered for measurement.
Supply & fixing cable route marker made of MS 150mm dia with supporting angle 25 x 25 x 3mm for HT cable route including PCC (1:3:6) and earth work complete all as specified and directed.
M&L for making platform of outdoor type transformer PCC block platform of size 3 mtr x 3 mtr x 1.5 mtr in PCC (1:3:6) thick foundation bed in PCC (1:4:8) type D-2 (using 40mm graded stone aggregate of 50mm thick coping in PCC (1:2:4) type B-1 (using 20mm graded stone aggregated) over platform and 15mm thick rendering CM (1:6) to exposed surface of PCC and applying three coat of white wash complete all as specified and directed. Note : Quoted unit rate is deemed to be included the necessary cost of excavation, returning, filling, removal and approved earth required for filling in the floor
Supply & fixing of decorative type garden light fittings of 25watt of CCT more than 5000K including light fixing pole of diaa as per bollards dia of height 3.5 mtr approx including excavation making foundation for the fitting electric connection etc complete all as specified and directed. Make : Product code PGR0201007 in Polycab or equivalent in C&S/ L&T/ Philips.
SOLAR WATER HEATING SUPPLY
Supply, fixing connecting and testing energy efficient (BEE 5 Star rated) electric water heater vertical storage type of 25 Ltrs capacity with stainless Steel inner tank, brass assembly, pressure release valve, heating element 1500 W including all other accessories with high quality external finishes single phase with working voltage 240 volts, 50 Hz, ISI marked complete all as specified and directed. Note : The cost of fixing of geysers including stud/ nuts, bolts, washers and making good the disturbed surfaces to match with the existing surface is deemed to be included in the unit rate quoted.
M&L for PVC connection ( Hot )of size 15 mm bore, 600 mm long superior quality for geyser complete with Brass adopter for geyser for any capacity
Supply and Fix NRV suitable for 20 mm bore pipe complete all as specified.
M&L cladding to pipes all around with 20mm thick bonded mineral wool performed 'SNAPON' pipe sections of density 144 Kg/Cum complete all as specified and directed.
Supply and fixing MCB 40 Amps SP, 10 KA,240 Volts, B Series complete all as specified and directed.
Description all as per Srl Item No.7.05 here-in-before but single pole and neutral 40 Amp, B Series complete all as specified and directed
EXTERNAL WATER SUPPLY WORKS
Cutting of existing 150 mm dia C.I pipe line, inserting Tee of size 150 x 150 x 80mm for taking branch connection of 80 mm dia including gasket, bolts, nuts fitting and earth work complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 60cm x 60cm x 60cm (internal size) with mild steel sheet cover 3.15mm thick and frame of angle iron of size 40x40x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work,150mm thick PCC (1:4:8) type D-2 as in foundation,brick work in cement mortar (1:6),locking arrangement, and all inner size of pit shall be plastered 15mm thick in cement mortar (1:4) and coping in PCC (1:2:4) type B-1 over brick wall complete all as shown in Drg No CEJZ/TD-1060/08 Sh 1/3 to 3/3 of dated 01 May 2008.
SUMMER APPLIANCES WORKS
Supply and Fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 2 KVA complete all as specified.
ARBORICULTURE WORKS
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil , seprate the roots/grass and good earth by sieving with suitable seive size , stacking of good earth & mixed with suitable manure of ratio 5:1 including supply of manure, screened through sieve of 1.5 designation 4.75 mm and spreading the mixture of good earth & manure , applying suitable pesticides , watering to a depth of 15cms, including removal of roots/grass out of site complete all as specified and directed by the Garrison Engineer.
Material and Labour for developing Lawn by laying and dibbling of grass Steallars of 'DOOB GRASS' planting , roofing etc complete as aprroved and as directed by the Garrison engineer.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Flcus benjanamina" with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Plumeria alba " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Ficus Panda " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Ficus Kingbush " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Phonenix syvistris " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Cycas cirnals " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved red earth along with and manure (composit) in the proportion (3:1) and including Supply and Planting " Cycas revolute " with proportionate girth , remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Description same all as per serial No. 10.09 here-in-before but the name of the plant Furcaria Watsoniana complete all as specified and directed.
(MAINTENANCE AND UPKEEPING OF NEWLY DEVELOPED PLANTS/ GARDENS UNDER ITEM NO 10.01 to 10.10 FOR 24 MONTHS) Day to Day maintenance of newly developed plants/gardens/Trees plants by deploying minimum 01 gardner (experienced Mali) for guarding / security of the plants/ gardens including triming, suitable support for trees, etc as required as per standard practice all as specified and all as directed by the Garrison Engineer. NOTES :- (i) Periodical deweeding of unwanted vegitation growth around the plants and garden area. (ii) Watering all the Plants/Gardens/Trees as required for the proper growth. (iii) Periodical Lawn Mowing. (iv) Treating the plants and soil with required manure , pesticides and fertilizer including necessary topping of red earth and finally fine dressing, levelling etc (v) During the maintenance of any plant, if it is found dead, not true to the name or size as specified or not in satisfactory growth, plant of approved size & shape shall be replaced by the contractor without any extra cost to the Department. (vi) Supply and application of manure, sweet earth & pesticides, fertilisers, cartage as required etc are included in quoted unit rate during maintenance period. (vii) Commencement of maintenance period of two years will commenced only after certified date of completion of work. (viii) Water will be supplied by MES . (ix) Hose pipe required for watering will be provieded by the contractor and their cost is deemed to be included in the unit rates quoted by the contractor. (x) Cost of maintenance and upkeep will be deemed to be inlcuded in quoted rates. (xi) Necessary T&P required shall be arranged by the contractor
Half brick circular tree guard internal diameter 1.25 m and 1.2m above ground and 0.20m below ground bottom two courses laid dry and top three courses cement mortar (1:4) complete including necessary earth work all as specified and directed.
Supply and fixing mobile sprinkler automatic system of plastic made along with hard flexible pipe 15 mm bore complete all as specified and directed.
siddharthenterprises
ELECTRA ENGINEERS
MAHESH KUMAR SINGLA CONTRACTOR
M/s R.N Construction Co.
Kartik Builders
UNITED SAINI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .