Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹29.4 L
EMD Value
₹58,740
Closing Date
14 Feb 2022, 6:00 pmClosed
S K Tiwari
TSD, BARC
Annual Maintenance Contract of water supply and distribution system at EHPPL Kalyan BARC facility , village Chinchavali, Kalyan (period - 18 months).
2022_BARC_669910_1
BARC/TSD/69/2021-22
Open Tender
Pipes and Pipe related activities
Works
547 days
EHPPL Kalyan
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹58,740
Yes
TSH
24 Mar 2022
25 Jan 2022
18 Feb 2022
25 Jan 2022
14 Feb 2022
8 Feb 2022
25 Jan 2022 - 8 Feb 2022
7 Feb 2022
Amount
Excavation in all types of soil . As per tender specification .
Complete cleaning of open area,As per tender specification .
Modification/repair of CI/MS pipe : New laid Joint including removing of lead from old joint and refilling of new lead to stop water leakage from 100 & 150mm NB CI pipe line (5kg/sq.cm)
Modification/repair of CI/MS pipe ; Only cocking with lead wool for preventing minor leakage from 100 & 150 mm NB CI pipe line(5kg/sq.cm)
Modification/repair of CI/MS pipe ; 150 mm. dia CI,Coller (1 joint = 2pcs) including joint accessories
Modification/repair of CI/MS pipe ; 80mm dia. MS pipe joint. Including, cutting,cleaning,grinding, welding, finishing & painting
Construction of PCC supports for CI/MS pipes and reconditioning of the road with cement mortar 1:2:4 as directed by EIC.
Only installation, testing and commissioning of CI pipe line including removal of existing deteriorated pipe. : 150 mm NB CI pipe
Only installation, testing and commissioning of CI pipe line including removal of existing deteriorated pipe. ; 100 mm NB CI pipe
SITC of New 50 mm Dia Water Meter (Electromagnatic type)With Suitable S.S Strainer test lab certificate from MIDC including removal of old water meter from exiting site, Preferred make - Siemens , As per Tender Specification .
Dismantling of old defective meter , repairing , calibrated test certificate from approved MIDC Lab. & deposited / installation to EHPPL office.
Re-installation of MS items including dismantling / cutting / shifting / cleaning / refabrication / reinstallation / painting / testing & commissioning at EHPPL complex
SITC of M.S. Item like channel , angel etc . As per tender specification .
Only Servicing of isolation / gate /NRV/ glove /butterflyValves . (as per specification).; 250mm NB
Only Servicing of isolation / gate /NRV/ glove /butterflyValves . (as per specification). ; 200mm NB with chamber cleaning
Only Servicing of isolation / gate /NRV/ glove /butterflyValves . (as per specification). ; 150mm NB
Only Servicing of isolation / gate /NRV/ glove /butterflyValves . (as per specification).; 100mm NB
Complete cleaning of underground /overhead tank by high pressure cleaning system
Painting (MS item) Complete painting of existing MS structure/ piping/ladders at site .As per technical specification .
Dismantling and re-installation of GI pipes with fittings & accessories from existing site and refitted , reinstallation ,As per technical specification ; 25mm NB
Dismantling and re-installation of GI pipes with fittings & accessories from existing site and refitted , reinstallation ,As per technical specification ; 50mm NB
Shifting of scrap (heavy items ) by using of mechanical arrangement (Hydra / JCB/foreclip ) from one place to another place at EHPPL site.As per tender specification .
Removal of Submersible pump from existing well , cleaning, servicing, reassembling , reinstallation , testing and commissioning at existing site .
Repairing of Submersible pump including removal from existing well, reinstallation, testing & commissioning at existing site.
SITC of new SS 304L of dia 125NB spare like Flange and elbow including welding joint/cutting /Fitting/finsing and cleaning.As per tender specification.
Fabrication of SITC S.S. 304 L with Angle / Channels / Strips /Pipes/plate , as per tech specification .
Complete servicing / overhauling Diesel engine ( Cap- 127 HP ) , As per tender specification .
Complete servicing / overhauling of fire pump with automation panel & pressure hold test in fire fighting pipe line.
Complete servicing / overhauling of fire pump with automation panel & pressure hold test in fire fighting pipe line-------- Centrifugal pumps ( D. G. opreated fire pump , 127HP, 165 cu.m/hr ) along with motor as per specification. (Qty-1)
Complete servicing / overhauling of fire pump with automation panel & pressure hold test in fire fighting pipe line.-----Centrifugal pumps (Main fire pump , 100 HP, 165 cu.m/hr ) along with motor as per specification. (Qty-1)
Complete servicing / overhauling of fire pump with automation panel & pressure hold test in fire fighting pipe line.-----Centrifugal pumps ( Jocky pump , 40 HP, 667 lpm ) along with motor as per specification. (Qty-1)
Servicing with replacement of spare for fire hydrent post valve As per tender specification .
SITC of Submersible pump 2.0 HP single phase, make Kirloskar / Crompton Greaves including 15 mtr. Lenght conneting wire& flxival hose (ISI standrad / OEM supplied for each pump)as per enclosed specification
Fabrication/SITC of new Hose Box----- SITC of hose box,made of 16SWG GI CRCA sheet of size 750x250x600mm to accommodate 2 nos. of hose pipe and 1 no. of Branch pipe. The box shall have front glass door with locking arrangement. The box shall be fixed on wall/ open area as required. The box shall be dully coated with RED from outside and WHITE from inside as per specifications. Make:- Vilas or Equivalent
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .