Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.7 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹29.6 L+₹1.4 L (4.85%)Rejected-Finance 118 442 E 2 KAUSHALPURI KANPUR 208012 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208012 | 2 | Rejected-Finance Being other than L-1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR AND MAINT OF E/M AND W/S INSTALLATIONS AND OTHER CONNECTED MISC ITEMS AT MIL STN BARABANKI OF AGE E/M UNDER GE (EAST) LUCKNOW
2021_MES_448543_1
GE/E/LKO/T-12 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Barabanki
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE EAST LUCKNOW
₹56,000
Yes
27 Jul 2021
4 Jun 2021
2 Jul 2021
4 Jun 2021
1 Jul 2021
18 Jun 2021
60 days
Amount
M&L for repairs to LT out door feeder panels of size 1.8m x 1.20 m x 0.50 m installed in the station by welding front openable door and replacing hinges & locking arrangements and applying two coat of synthetic enamel paint on entire inner and outer surfaces including a coat of red oxide primer on repaired surfaces complete all as specified and directed.
M&L for repairs to LT out door feeder panels of size 1.5m x1.10m x 0.45m installed in the station by welding front openable door and replacing hinges & locking arrangements and applying two coat of synthetic enamel paint on entire inner and outer surfaces including a coat of red oxide primer on repaired surfaces complete all as specified and directed.
M&L for repair and servicing of AMF panel board including fault finding and replacement of defective parts such as voltmeter, Ammeter, frequency meter, relays with wiring, complete all as specified and directed. Note: Fixture/spares shall be measured and paid seperately under repective items.
M&L for repair and servicing of Automatic power factor controller panel (TAS Powertek Pvt Ltd) board including fault finding and replacement of defective parts such as voltmeter, Ammeter, frequency meter, relays, start/stop push buttons MCB with wiring, complete all as specified and directed. Note: Fixture/spares shall measured and paid seperately under repective items.
S&F single core copper wire having nominal area10 sqmm, PVC insulated, multistranded, FR, for LT panels including necessary lugs and thimble as required on ground complete all as specified and directed.
S&F ammeter 0-200 Amps, square flush digital type as per sample complete all as specified and directed.
S&F ammeter 0-200 Amps, square flush Analouge type as per sample complete all as specified and directed.
S&F voltmeter 0-500 Volts, square flush digital type as per sample complete all as specified and directed.
S&F voltmeter 0-500 Volts, square flush Analouge type as per sample complete all as specified and directed.
S&F LED multifunction meter to measure voltage, current, frequency, power factor of Square flush, digital type as per sample complete all as specified and directed.
S&F current transformer for LT Panel, 100/5A, 2.5VA, CL 1.0, 50/60 Hz as per sample complete all as specified and directed.
Supplyy only KWH meter, 3 Phase, 4 wire, 415 Volts, accuracy class-I as per sample complete all as specified and directed.
Supply only KWH meter, single Phase, electronic energy meter of rating 5-30 Amp, class-1.0, 240V, 50 Hz, counter type display with transparent Hinge Type box as per sample complete all as specified and directed.
Supply only MNX power contactor 415 Volt, 50 Hz, AC of capacity 110 Amps as per sample complete all as specified and directed.
Supply only SMPS battery charger kit mounting in AMF panel as per sample complete all as specified and directed.
S&F AMF controller module in AMF panel as per sample alongwith connected relays and wiring complete all as specified and directed.
S&F in repair automatic generator start/stop relay as per sample complete all as specified and directed.
S&F in repair HRC Fuse unit HN size 00,100 amp 100 KA 415 Volt as per sample complete all as specified and directed.
S&F MCB DP 20 Amp 10 KA C-20 complete all as specified and directed.
S&F MCB DP 25 Amp 10 KA C-20 complete all as specified and directed.
S&F MCB DP 40 Amp 10 KA C curve complete all as specified and directed.
S&F MCB TPN 63 Amp 10 KA 415 V 50 Hz C curve complete all as specified and directed.
S&F MCCB TP 100 Amp 16 KA 415 V, 50 Hz complete all as specified and directed.
S&F MCCB 4 Pole 160 Amp 36 KA 415 V, 50 Hz complete all as specified and directed.
S&F MCCB 250 Amp 4 pole 36 KA 415 V complete all as specified and directed.
Supply only start-stop push button suitable for automatic power factor controller, GREEN and RED coloured complete all as specified and directed.
S&F neon LED indicator lamp prewired as per sample complete all as specified and directed.
S&F OFF LOAD CHANGE OVER SWITCH 100 Amp, 4 pole complete all as specified and directed.
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 10 sqmm, 2 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 16 sqmm, 2 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 25 sqmm, 2 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 16 sqmm, 4 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 25 sqmm, 4 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 35 sqmm, 4 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 50 sqmm, 3.5 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 70 sqmm, 3.5 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 150 sqmm, 3.5 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil, complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete all as specified and directed.
M&L for sand cushioning for protection of cables, complete, all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2, flat of size 300mm x 180mm x 40mm over LT cable laid flat for protection of cable complete all as specified and directed.
Supply, fixing and erecting in position 9.0 Mtr steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) Painting will be measured and paid seperately under relevent item.
M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in base foundation of pole including providing necessary form work complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including necessary form work complete all as specified and directed.
S&F heat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 25 to 50 sqmm complete all as specified and directed.
S&F heat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 70 to 120 sqmm complete all as specified and directed.
Labour only for 'B' check maintenance/servicing of DG set including replacing of defective wornout parts by new spares such as filters, V belt, engine oil, rubber hoses etc for 62.5 KVA DG set complete all as specified and directed. Note: Fixture/spares shall be measured & paid seperately under repective items as suuply only.
Supply only diesel filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only oil filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only air filter element with 'O' ring as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only fan belt as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only alternator belt as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only rubber hose pipe set complete with clamps as per sample suitable for 62.5 KVA DG set complete all as specified and directed.
Supply only engine oil multigrade 20 W 40 complete all as specified and directed.
Supply only inhiibitor corrosion (coolant for radiator) complete all as specified and directed.
S&F in replacement battery lead set PVC insulated multistranded copper conductor 50 Sqmm, 1.25 m long each fixed with brass cladded copper clamps suitable for DG set 62.5 KVA, complete all as specified and directed.
S&F in replacement maintenance free battery suitable for 62.5 KVA DG set, having 105Ah with alteast 24 months warranty complete all as specified and directed. Make: Exide Gen Plus GP115E41L or equivalent in Luminous/Amaron.
Cleaning of fuel tank both internally and externally by removing all the dust/sediments etc, complete all as specified and directed.
Taking down and cleaning the radiator both internally and externally by removing all the dust/sediments and cleaning of capillary tube by pressure and refixing complete all as specified and directed.
S&F in repairs rigid non-metallic PVC conduits of external dia not less than 25 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing with street light pole using suitable fixing accessories complete all as specified and directed.
S&F copper wire three core multistrand FRLS 1.5 sqmm complete all as specified and directed.
S&F MCB, SP 5 to 30 Amps, 240 volts bracking capacity 10 KA, ISI marked complete all as specified and directed.
M&L for Cleaning and preparation of old painted surface of street light steel tubular pole 9mtr long and painting with two coat of aluminum paint including brackets including applying two coats of cement base paint to coping, rewriting Pole No complete all as specified and directed.
S&F time switch astronomical type suitable with rising/setting of the sun with IP 20 protection, AC, 230 volts, one channel, two module and making connections by using suitable copper lugs complete all as specified & directed. Make: Legrand, Cat No : 4126 54 or equivalent in HAGER/SCHNIDER
S&F contactor 63 amp capacity, 3 Pole having coil voltage 220 V, 50 Hz for time switch complete all as specified and directed.
M&L for locating fault in U/G LT cable by using fault detector machine including transportation and by carring out high pressure test complete all as specified and directed.
S&F of street light fitting Pressure die cast aluminium housing (LM6 Alloy), Minimum 9000-10000 Lumens with maximum system wattage 90 W-100 W, proper heat shinks and toughtened glass ensuring IP66 & IK>05 protection,surge protector, electronic driver all including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required necessary wire for fitting light to pole complete all as specified and directed.Make: Philips Cat Part No BRP410 LED 094 CW HE MR FG S2 PSU GR, CG Cat Part No LSTN-100-CDL-A or equivalent in Havells.
S&F bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5 m long including necessary GI clamps, nuts bolts and washers and connecting with thee core flexible wire of 1.5 sq mm copper conductor to the pole junction box complete all as specified & directed.
S&F in replacement of LED security light fitting 40 watt, 3500 lumen, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size all as specified and directed.
Cleaning/clearing of vegitation around the installations and disposing off complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, earth plate connected with GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, earth plate connected with GI wire 4mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm including bore provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
Supply only 10 Sqmm 2 core aluminium unarmoured, flame resistant PVC flat cable, ISI marked complete all as specified and directed.
Trimming of tree branches touching to the HT/LT over head line or near to the HT/LT over head line or near security light poles as per the direction of AGE E/M/ JE incharge complete including removing the tree branches as directed. Note :(i) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job (ii) Any damage cause due to contractor's workers will be rectified by the contractor without any extra payment to Govt. (iii) T & P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor. (iv) Proper shut down in writting will be obtained from AGE E/M before start the trimming of tree branches every day.
S&F in replacement of integrated LED bulk head fitting with 12 Watt LED lamp, 60 lumen, 6500K with IP 66 and IK 09 impact resistance protection comprises of high pressure die cast aluminium housing, polycarbonate cover etc complete all as specified and directed.
S&F LED post top lantern fitting for 360 degree indirect light 40W IP 65 protection complete all as specified and directed.
S&F LED Flood Light 100W equiped with IP 66 protection or above complete all as specified and directed.
M&L in replacement of test point terminal block made out of gun metal of phospharus bronze fixed in 75 x 75 x 25 mm MS/polycarbonate enclouser drilled and screwed including 3 Nos of 8 mm dia 25 mm long screw complete all as specified and directed.
S&F in replacement GI strip of size 32mm x 6mm as earth continuity conductor with adequate size saddles fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F PVC/SMC weather proof, hinged door, junction box, size 300mm x 200mm x 100mm with 30A Aluminium bus bar 04 Nos, 240V, Neutral link and 1No MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc complete all as specified and directed.
S&F 4mm dia GI wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F FRP smart meter box of appropriate size for single phase electric meter complete all as specified and directed.
S&F polycarbonate tampered proof electric meter seal complete all as specified and directed.
S&F GI tubes light grade of size 40mm galvanised complete all as specified and directed.
Horizontal boring of road for laying of pipe not exc 90 cm below ground level all complete as specified and as directed.
Taking up or down old U/S 100mm bore pipe CI water main pipes with fittings complete all as specified and directed.
Supply & laying 100mm bore CI pipe with spigot and socket end or flanged end centrifugally cast class B in any length and laid in trenches.( Note : All CI special special /fittings shall be measured and paid seperately under respective items) complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
S&F of CI fittings / specials like Bend (any rsadius and angle) , Taper any type ( straight , bends,increasing,decreasing,or double socket etc), Tee pieces single byanch 'Y' junction, double branch cross (all socket or socket and spigot), collar caps and plugs etc upto 150 mm dia complete all as specified and directed.
M&L for flange joints with rubber or fiber board gasket 150 mm dia flange joints in the trenches/wall, complete all as specified and directed.
M&L for flange joint 100mm bore by digging out up to depth of existing pipe line and complete the joint by using D-joint including necessary flange of 20 mm thick, 6 mm thick rubber insertion, nuts, bolts, washers including bailing out the accumulated water in the trenches, complete all as specified and directed.
M&L for flange joint 80mm bore by digging out up to depth of existing pipe line and complete the joint by using D-joint including necessary flange of 20 mm thick, 6 mm thick rubber insertion, nuts, bolts, Washers including bailing out the accumulated water in the trenches, complete all as specified and directed.
M&L for joint of DI pipe 100mm bore with rubber or fiber board gasket for the following sizes with necessary bolts and washers etc including dismantling complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 100mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 80mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 50mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 40mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 25mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 20mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Taking out/down of old GI pipe line with fitting of 15mm bore from trenches, floor, wall, ceiling etc. complete all as specified and directed.
Relaying of GI pipe 25mm bore pipe after removal of scalling , cleaning and flushing etc including supply and fixing of new fittings of required grade in trenches and testing complete all as specified and directed. Note: Old serviceable pipes shall be used obtained from taking out/down.
Relaying of GI pipe 20mm bore pipe after removal of scalling , cleaning and flushing etc including supply and fixing of new fittings of required grade in trenches and testing complete all as specified and directed. Note: Old serviceable pipes shall be used obtained from taking out/down.
Relaying of GI pipe 15mm bore pipe after removal of scalling , cleaning and flushing etc including supply and fixing of new fittings of required grade in trenches and testing complete all as specified and directed. Note: Old serviceable pipes shall be used obtained from taking out/down.
Supply & laying 100mm bore GI pipe medium grade with all fittings, laid in trenches or on walls, complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 80mm bore GI pipe medium grade with all fittings, laid in trenches or on walls complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 50mm bore GI pipe medium grade with all fittings, laid in trenches or on walls complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 40mm bore GI pipe medium grade with all fittings, laid in trenches or on walls complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 25mm bore GI pipe medium grade with all fittings, laid in trenches or on walls, complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 20mm bore GI pipe medium grade with all fittings, laid in trenches or on walls, complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
Supply & laying 15mm bore GI pipe medium grade with all fittings, laid in trenches or on walls, complete all as specified and directed . Make: Jindal/Tata/Prakash /Surya
S&F 50mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking out old unviceable gate valve complete all as specified and directed..
S&F 40mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking out old unviceable gate valve complete all as specified and directed..
S&F 25mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking out old unviceable gate valve complete all as specified and directed..
S&F 20mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking out old unviceable gate valve complete all as specified and directed..
S&F 15mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe including taking out old unviceable gate valve complete all as specified and directed..
M&L for identify the leakage in 100mm bore GI pipe line and repair the same to make it 100% leak proof including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 80mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 50mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 40mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 25mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 20mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
M&L for identify the leakage in 15mm bore GI pipe line and repair the same to make it 100% leakage including S&F necessary fitting and other materials for joint including necessary excavation in any type of soil and returing filling with proper compaction complete all as specified and directed.
Supreme Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .