Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and Reasonable | |
| 2 | L2₹30.7 L+₹3.8 L (13.9%)Rejected-Finance KACHERY ROAD BALASORE 756001 ODISHA | BALESHWAR | ODISHA | 756001 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹30.8 L+₹3.9 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹31.2 L+₹4.2 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹31.6 L+₹4.6 L (17.2%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
24 Sept 2022, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur Post Chandipur PIN 756025
RENOVATION OF LECTURE HALL AT PROOF BHAWAN BLDG AT PXE CHANDIPUR
2022_MES_536730_2
8726/CDP
Open Tender
Civil Works
Item Rate
180 days
Chandipur
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R and D Chandipur
₹49,400
Yes
5 Nov 2022
2 Sept 2022
26 Sept 2022
2 Sept 2022
24 Sept 2022
15 Sept 2022
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (B/R PORTION)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes for non skid ceramic and grinaite tiles complete all as specified and directed.
M & L for Rendering 10 mm thick cement plaster in CM 1:4 on fair faces of brick Work for fixing of wall tiling complete all as specified and directed.
M & L for Vitrified ceramic light shade tiles 10 mm thick area of each tile exc 0.18 sqm not exceeding 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and directed.
M & L for Non Skid coloured ceramic joint free tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm (300 mm x 300 mm) in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
M & L for Glazed ceramic coloured tiles 400 mm x 350 mm x 7 mm / 300 mm x 450 mm x 7 mm / 450 mm x 300 mm x 7 mm thick white or coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
All as per Sl Item No. 1.07 here-in-above but Reinforced Cement Concrete.
M & L for RCC 1:2:4, type B-1 (using 20 mm graded aggregates) as in shelves complete all as specified and directed.
M & L for RCC 1:2:4, type B-1 (using 20 mm graded aggregates) as in chajjas and similar suspended work in any situation complete all as specified and directed.
Form work to chajja, weather shades, cooking platform, shelves incl fair finish flat surfaces of the concrete slab.etc complete all as specified and directed.
M & L for mild steel TMT bar (Fe 500 D) 10 mm dia and over cut to length bent to shape includingbbending & binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed
M & L for mild steel TMT bar (Fe 500 D) 6 mm to 8 mm dia cut to length bent to shape includingbbending & binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed
M & L for running welding for new reinf with old reinf for binding exc 9 mm but not exc 20 mm complete all as specified and directed.
M & L for One coat of Nito bond EP applied on old concrete surface by brushing or spraying before placing new concrete (it is required for bonding new concrete & old concrete) complete all as specified and directed.
M & L for two coats of "Pidifin 2K " of Dr. Fixit or equivalent as approved by GE, applied on external surface of brick wall before plastering as per manufactureres instruction complete all as specified and directed.
Demolition of brick work built in cement mortar incl quoin, arches etc complete all as specified and directed.
M & L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed.
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15 mm bore complete all as specified and directed.
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 20 mm bore complete all as specified and directed.
Cutting chases in walls or concealed water tubing and making good in CM 1:3 exc 10 cm but n.exc 20cm girth complete all as specified and directed.
S & F for 25mm bore PPR polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised & antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floor etc.
S & F for 20mm bore PPR polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised & antimicrobial welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floor etc.
Taking down chowkath or frame exc 1.5 sqm n exc 4 sqm with shutter (without taking of shutters from frames) complete all as specified and directed.
Taking down chowkath or frame n exc 1.5 sqm with shutter (without taking of shutters from frames) complete all as specified and directed.
Supply and Fixing powder coated aluminium frame for doors, windows & ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified.
Supply and Fixing powder coated aluminium three tier window and ventilator shutter , aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber packing, to recieve glass/wiremesh , screws , anodised aluminium fittings such as suitable handle ( 1 no) with locking arrangement in each shutter complete all as specified & as directed.
Supply and Fixing powder coated aluminium door shutter of aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc including necessary fittings and fixes of handles, hinges, tower bolt and aldress complete all as specified & directed.
S & F for 12 mm thick veneered block board interior garde , solid core , general purpose type, with face veneers of type BB fixed with screw to timber frame work complete all as specified & directed.
Supply & Fixed 5.50 mm thick plain sheet glass exc 0.5 sqm in each pane fixed to aluminium door,window & ventilator complete all as specified and directed.
S & F galvanised stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire stapple complete all as specified & directed.
S & F 75 x 75 mm aluminium anodised grill of DG -916 of Make - Deco grill or equivalent as approved by the GE, 10 mm thick to aluminium window complete all as specified & directed.
Taking down cement plaster on wall; ceiling,etc incl racking out joints hacking for keys, scrubbing with etc complete all as specified and directed
M & L for Rendering 15 mm thick cement plaster with WPC @ 3% of wt of cement on external surfaces of brick work in CM 1:4 andn surface to be finished even & smooth without using extra cement. (WPC will be measured and paid separately).
Supply only Integral Water Proofing Cement.
M & L for Rendering 5 mm thick cement plaster in CM 1:3 on fair faces ceiling, Chajja, shelves and surface to be even and fair complete all as specified & directed.
M & L for Rendering 10 mm thick cement plaster on internal surfaces of brick work in CM 1:6 and surface to be finished even & smooth without using extra cement complete all as specified & directed.
M & L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
M & L for Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified & directed.
Complete removal of existing treatment, washing with water and applying two coats of exterior emulsion paint on external wall surface over a coat of primer as directed.
M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed.
S & F for PVC (SWR & RWP) pipes single socketed in any length with rubber ring joints of dia 110mm fixed to wall complete all as specified & directed.
S & F for PVC (SWR & RWP) bends any radius of bore 110 mm incl. with access door fixed in repair complete all as specified & directed.
S & F for PVC (SWR & RWP) junction single (single 'T') equal or un equal of bore 110 mm incl. With access door fixed in repair complete all as specified & directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed.
M & L for roof treatment using APP based polymeric membrane minimum weight 3.5 kg/sqm and 3 mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) over a coat of primed and bonding surface by forced application, including taking down old felt complete all as specified and directed.
M & L for avg 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof paddding complete all as specified
M & L for Rendering 10 mm thick cement plaster in CM 1:4 on roof surface complete all as specified & directed.
S & F vention roller blinds,horizontal type with high strength reinforced plastic including clutch of wrap spring design of high carbon steel to reansmit motion from driving to driven members of clutch mechanicum compressing of idler,head rail,roller tube,bottom rail,operating chain and fixing as per directed.
Dismantling of wall / ceiling boards (fibre, pulp,insulation, etc.) or insulation boards/ slab/blankets, any thickness including cover fillets complete all as specified & directed.
M & L for hanger 6 mm dia GI (upto 1200 mm length) adjustable level fixed to roof slabs by means of ceiling cleat made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fastener 12.5mm dia 40mm long complete all as per manufactirer's instruction.
S & F for aluminium snap grid frame work (size 605 mm x 605 mm) for false ceiling complete all as specified & directed.
S & F for 25 mm thick acoustic board with fabric 60 cm x 60 cm in size fixed as per manufacturer's instuction in false ceiling in frame grid of 605 mm x 605 mm complete all as specified & directed.
S & F for framed work as in wall panneling of angle or other section with gusset plates, rails,braces, etc., of Fe-410 W (Gde-E-250) Quality B complete, also fastening, welding and fixing complete all as specified & directed.
S & F for 10 mm thick acoustic wall panelling coloured inclusive of solvent cement and fixing at site on PVC frame complete all as per manufacturer's instruction.
SCHEDULE 'A' PART-II (E/M PORTION)
Taking down carefully copper /aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L switch piano flush type single pole two way 5 Amp including connections.
M&L switch socket combinatrion 2 in 1,5 Amp flush type including connection
M&L switch socket outlet multipurpose 3 pin,15 Amps and one 5 Amp controlled by one switch
M&L ceiling rose PVC poly carbonate,isolated body with three terminals including connection.
S&F stepped type electronics fan regulator flush type 230/240V complete all as specified
Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement.
Supply and fix in repair circuit/sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit 20 mm bore heavy grade complete all as specified and as directed by the Engr-in-Charge.. Note : (i) Three runs of 4 Sqmm and one run of PVC conduit shall measured as one length.
Supply and fixing in repair single pole and neutral sheet metal enclosure box including metallic two pin Plug and socket with 20 Amps MCB (SPN) 'C' series including connection with two runs of 4.0 sqmm.copper cable with one run 4.0 sqmm copper cable for earth continuity with taking down old U/S existing sheetmetal enclosure.
Supply and fixing of Square recess mounted LED full open 2x2 ft.Tile , Glare free uniform illumination downlight of capacity 36 watt with die-cast aluminium housing finished in premium white powder coating including all fittings.
Supply and fixing 1x16 watt LED indoor box type surface / suspended water proof industrial luminaire with polycarbonate housing and diffuser with LED retrofit T-8 Tube, IP66 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
S&F Polycarbnonate T-8 tube with in built driver with metal heat sink double sided connection of capacity 1 x 20 watts all as spcified and directed.
Taking down serviceable / unserviceable switch fuse unit/MCB DB with MCB etc for necessary repair/replacement and reuse all as directed.
Supply and fixing of MCB DB double door, made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and din rail SPN 8 way with 200 Amps rated bus bar 240 Volts including taking down.
Supply and fix Air Irculator fans AC single phase 230 Volts, oscilating 450 mm sweep suitable for wall mounting all as specified and directed.
Supply and fix fans ceiling complete with blades, down rods, electronic type regulator and accessories 230 V,1200 MM sweep minimum air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) complete including necessary PVC insulated flexible wire 3 core of suitable size for connecting from ceiling rose to connector, etc. complete all as specified and as directed.
Supply and fixing exhaust fans metal body AC single phase 230/240 V of size 300mm sweep with lover shutter, heavy duity 1400 RPM fixed to wall with suitable size bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of size 24/0.2 mm with copper conductor complete all as specified and directed.
Supply and fixing of VTPN DB double door,IK 09,IP43-Metal door, 4 way, made of CRCA sheet steel, RAL 9003,powder coated with bus bar, neutral link, earth bar withprovision for DU125A MCCB,4 pole as incomer and SP/TP MCBs as Outgoings, including taking down old one.
S&F MCCB 4 pole,125 Amps, for Incomer of VTPN with fixed thermal & magnetic release of breaking capacity 25 kA, DU125H (Icu=30kA,Ics=50% Icu), 415 Volts.
S & F MCB 40 Amps SPN `C' series breaking capacity 10KA complete all as specified and as directed.
S & F MCB 06 to 32 Amps SPN `C` series breaking capacity 10KA complete all as specified and as directed.
S & F MCB 06 to 32 Amps SP `C` series breaking capacity 10KA complete all as specified and as directed.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25 mm x 3 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I including taking down old one , and all as directed and specified
M&L for fixing of earth contuninity conductor or main earthing lead aluminium strip 25x4 mm with shaddle,nut,bolts etc on existing roof conductor and down conductor fixed with and including fixing accessories and connecting to ground conductor complete.
R.B.Construction
jlenterprise
ALLIANCE
RANA ENTERPRISES
M/SNeelachal Enterprises
bholanath bera
M/S DK MUKHERJEE CO
M/s R.C REFRIGERATION
Bidder Name
RANA ENTERPRISES
ALLIANCE
FRIENDS CONSTRUCTION
M/s R.C REFRIGERATION
R.B.Construction
M/SNeelachal Enterprises
jlenterprise
M/S DK MUKHERJEE CO
bholanath bera
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .