Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹67.2 L+₹7.2 L (11.9%)Rejected-AOC SAINI NIWAS ZOO ROAD TUTIKANDI SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹80.4 L+₹20.3 L (33.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹80.6 L+₹20.6 L (34.3%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹77.1 L
EMD Value
₹1.5 L
Closing Date
29 Dec 2021, 5:00 pmClosed
E. E. SHIMLA DIVISION NO. III, HPPWD, Shimla-3
E. E. SHIMLA DIVISION NO. III, HPPWD, Shimla-3
C/O conference hall and smart class room building at Rajiv Gandhi Govt. Degree College at Kotshera Shimla.
2021_PWD_54931_1
SD-III-CB-tender/ 21-22-21048-65 dated 18-12-21
Open Tender
Civil Works
Item Rate
120 days
Chaura Maidan
As per Bidding Documents
11 documents required · 11 mandatory
₹2,000
₹1.5 L
16 Mar 2022
23 Dec 2021
30 Dec 2021
23 Dec 2021
29 Dec 2021
23 Dec 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.50m in width as well as 10sqm on plan) including getting out and disposal of excavated earth complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge:- Ordinary rock.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge:- Ordinary rock.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Suspended floors, roofs, landings, balconies and access platform and Shelves (Cast in situ) complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Lintels, beams, plinth beams, girders, bressumers and cantilevers complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Columns, Pillars, Piers, Abutments, Posts and Struts complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Edges of slabs and breaks in floors and walls Under 20 cm wide complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Cornices and mouldings complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1cement : 1.5coarse sand): 3 graded stone aggregate 20mm nominal size) complete including carriage of materials within all leads and lifts as per direction of Engineer-in- charge
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor all level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20mm nominal size) complete including carriage of materials within all leads and lifts as per direction of Engineer-in- charge.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). upto floor all level complete including carriage of materials within all leads and lifts as per direction of Engineer-in- charge.
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand): 3 graded stone aggregate 20mm nominal size). upto floor all level complete including carriage of materials within all leads and lifts as per direction of Engineer-in- charge.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and Medium Tensile steel bars complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20mm nominal size) complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 cement : 3 coarse sand) : 6graded stone aggregate 20mm nominal size) complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)complete including carriage of materials within all leads and lifts as per direction of Engineer - in - charge.
Providing and fixing 19mm thick commercial Board shutters for cup boards including fixing with nickel plated piano hinges with screws etc complete including carriage of materials within all leads and lifts.
Providing and fixing 19mm thick commercial board in shelves/box for cup board with butt joints and fixing with nails and screws etc complete including carriage of materials within all leads and lifts
Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality:- 1.00mm thick complete including carriage of materials within all leads and lifts.
Providing and fixing 2nd class hard wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge.
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete including carriage of materials within all leads and lifts:- Double strip (horizontal type).
Providing and fixing 100mm bright finished brass handles with screws etc. complete including carriage of materials within all leads and lifts.
Providing and fixing ply wood lining with butt jointing and nails (frame work and cove fillets to be measured and paid for separately) 6mm thick ply inclding carriage of materials within all leads and lifts.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) complete including carriage of materials in all leads and lifts.
For shutters of doors windows and ventilators including providing and fixing hinges/ pivots and making provisions for fixing of fittings where ever required including the cost of PVC/neoprene gaskets as required (fittings and glazing/ panelling shall be paid for separately) including carriage of materials within all leads and lifts.
Providing and fixing 12mm thick preleminated partical board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge. Pre-laminated particle board with decorative lamination on both sides complete including carriage of materials in all leads and lifts.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50kg/ sqm) complete including carriage of materials in all leads and lifts.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. (Only weight of grill to be measured for payment) complete including carriage of materials in all leads and lifts.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer- in-charge complete including carriage of materials in all leads and lifts:- 255mm X 19mm.
Providing and fixing 250mm x16mm size aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete as per architectural drawings and directions of Engineer- in-charge including carriage of materials within all leads and lifts.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts:- (i) 250mm x10mm size.
150mm x10mm size
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete including carriage of materials within all leads and lifts:- (i) 125mm size.
100mm size.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete including carriage of materials within all leads and lifts:- Twin rubber stopper.
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. complete including carriage of materials within all leads and lifts:- Sal wood.
Providing and fixing 12mm thick plain lining/ paneling with tongued and groved jointing and screws (frame work and cover fillets to be measured and paid for separately with 1st class indian teak wood complete including carriage of materials within all leads and lifts.
Providing and fixing 50mm X 50mm wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete including carriage of materials within all leads and lifts. 2nd class teak wood
Providing and fixing galvanised M.S. wire gauge of I.S. gauge designation No. 140g to doors, window and clerestory windows with wire of dia 0.71mm instead of I.S. gauge designation No. 85g with wire of dia 0.56mm including carriage of materials within all leads and lifts.
Precast terrazzo tiles hydraulic compressed 20 mm thick with marble chips of specified sizes laid in floors, treads of steps and landings on a bed of 25mm average thickness of cement mortar 1:6 (1 cement :6 sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles (wherever required) incliding rubbing and polishing complete with tiles of following shades:-WHITE.
Providing and laying vitrified floor tiles of 600mm X 600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. including carriage of materials within all leads and lifts.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) complete including carriage of materials within all leads and lifts:- 25 mm thick.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cement.
Providing and laying heavy duty pre-polished precast cement conrete inter locking paver blocks of NTC make or equivalent of approved design and shade vibro compacted of approved design, shade and size border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks including curing rubbing and polishing complete (Sub base concrete floor to be paid for sepretarly) 40mm thick block including carriage of materials within all leads and lifts.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22mm to 25 mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer Using rough kota stone complete within carriage of material in all leads and lifts.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete within carriage of material in all leads and lifts.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5mm x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete within carriage of material in all leads and lifts.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete including carriage of materials within all leads and lifts:- Ridges plain (500 - 600mm).
Flashings/ Aprons.( Upto 600mm).
Gutter (600 mm over all girth).
Providing and fixing M.S. tube hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer including carriage of materials upto all leads and lifts by mechanical means and manual labour and as directed by the Engineer in Charge.
Providing and fixing M.S. BP Sheet 2mm thick in eaves board/ facia/ soffits/ ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in charge (Base members of steel work shall be measured and paid separtely) including carriage of materials within all leads and lifts.
Providing and fixing on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.50 kg/sqm including filling the joints with approved adhesive and inclunding require No. of coller and clamps etc. complete including carriage of materials within all leads and lifts:- (i) 110mm nominal size.
Providing and fixing PVC Finolex plain bend ISI marked including fixing with approved adhesive etc. complete including carriage of materials within all leads and lifts (i) 110mm nominal size.
Providing and fixing in position collapsible steel shutters with vertical channels 20mm x10mm x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer complete including carriage of materials within all leads and lifts.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre complete including carriage of materials within all leads and lifts.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture including carriage of materials within all leads and lifts.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture ncluding carriage of materials within all leads and lifts.
Polishing two or more coats on new work with french polish on previously polished wood and wood based surface to give an even surface including cleaning the surface of all dirt,dust and sand papered smooth and including a coat of wood filler including carriage of material in all leads and lifts.
6mm cement plaster of mix in Cement Mortar 1:3 (1 cement:3 fine sand) including carriage of materials within all leads and lifts.
15mm cement plaster on riugh side of single or half brick wall finished with a floating coat of neat cement of mix 1:6 (1 cement: 6 fine sand) including carriage of materials upto all leads and lifts and as directed by the Engineer in Charge.
15mm cement plaster on fair side of single or half brick wall finished with a floating coat of neat cement of mix 1:6 (1 cement: 6 fine sand) including carriage of materials upto all leads and lifts and as directed by the Engineer in Charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of materials within all leads and lifts.
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including carriage of materials upto all leads and lifts and as directed by the Engineer in Charge.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work including carriage of materials upto all leads and lifts and as directed by the Engineer in Charge.
Stone soling properly hand-packed filling interstices with Kharanja stone including spreading watering of binding materials moorum or earth etc. complete as per HP.PWD specification 150mm spread thickness (finished work including materials and labour) including carriage of materials within all leads and lifts.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete including carriage of materials within all leads and lifts.
Akash Saini
Kailash Chand
Manishsharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .