| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAdmitted-Finance 0 NEAR MARKHAM COLLEGE JAIPRABHA NAGAR HAZARIBAG JAIPRABHA NAGAR HAZARIBAG JHARKHAND 825301 | HAZARIBAGH | JHARKHAND | 825301 | ₹3.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.5 Cr+₹2,794.10 (<0.01%)Admitted-Finance GRAM SIKRI BADHKAGOAN HAZARIBAG | HAZARIBAGH | JHARKHAND | 825301 | ₹3.5 Cr+₹2,794.10 (<0.01%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical N A | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S S. K. B. R. A. CIVIL AND MECHANICAL CONSTRUCTION L2 | dikshit shreya construction private limited L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 72.16 | M3 | 955.89 ₹68,979.89 Lowest | 955.89 ₹68,979.89 Lowest |
| 2.00 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 700.87 | M2 | 40.75 ₹28,560.33 Lowest | 40.75 ₹28,560.33 Lowest |
| 3.00 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 2,237.09 | M2 | 21.46 ₹48,007.99 Lowest | 21.46 ₹48,007.99 Lowest |
| 4.00 | Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l. | 419.52 | M3 | 5,244.08 ₹21,99,985.95 Lowest | 5,244.08 ₹21,99,985.95 Lowest |
| 5.00 | Providiag 125mm thick reinforced designation 75A brick work in Cement Mortar (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 including providing 10mm thick mortar joint, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l. | 121.62 | M2 | 713.49 ₹86,776.08 Lowest | 713.49 ₹86,776.08 Lowest |
| 6.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) | 64.94 | M3 | 6,082.45 ₹3,94,982.14 Lowest | 6,082.45 ₹3,94,982.14 Lowest |
| 7.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 16.9 | M3 | 6,308.87 ₹1,06,619.9 Lowest | 6,308.87 ₹1,06,619.9 Lowest |
| 8.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 72.67 | M3 | 6,308.87 ₹4,58,497.13 Lowest | 6,308.87 ₹4,58,497.13 Lowest |
| 9.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 160.8 | M3 | 6,308.87 ₹10,14,491.53 Lowest | 6,308.87 ₹10,14,491.53 Lowest |
| 10.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 112.59 | M3 | 6,308.87 ₹7,10,315.67 Lowest | 6,308.87 ₹7,10,315.67 Lowest |
Tender Value
₹3.5 Cr
EMD Value
₹6.9 L
Closing Date
13 Apr 2023, 5:00 pmClosed
District Engineer Zila Parishad Hazaribag
Zila Parishad Hazaribag
Miscellaneous Works for Upgradation of Ashram Recidencial Vidyalay Bhelwara Block Sadar District Hazaribag
2023_ZPHZB_68625_1
61/2022-23
Open Tender
Civil Works - Buildings
Percentage
540 days
Sadar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
Secretary, Zila Parishad Hazaribagh
₹6.9 L
Yes
15 May 2023
6 Apr 2023
17 Apr 2023
6 Apr 2023
13 Apr 2023
6 Apr 2023
Amount
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.
Providiag 125mm thick reinforced designation 75A brick work in Cement Mortar (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 including providing 10mm thick mortar joint, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases.
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges.
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing Tor steel reinforcement as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 8mm dia bar
Providing Tor steel reinforcement as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 12mm dia & above bar
Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I.
Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 20 guage G.C.I. sheet gate fitted on M.S. angle frame of size 60x60x6mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20 x 6 mm M.S flats or 16mm M.S square bars fitted on 25 x 5 x 6mm M.S angle frame of size 60 x 60 x 6mm including cost of fabrication providing necessary locking arrangement with haskal end dommy duly fixed in P.C.C. (1:2:4) block of required size, applying a priming red lead paint over steel work including cost of fabrication, carriage to site taxes all complete as per drawing specification and direction of E/I.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and joined with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete job as per building specification and direcition of E/l.
Providing and laying doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l.
Providing 6mm cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
Providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Extra for providing and fixing expanded metal mesh of size 20x60 mm and strands 3.25 mm wide 1.6 mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages, excluding cost of hangers.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Water proofing for Old and New Roof Slab :- Providng and laying water proofing treatment on roof slab by applying tow component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofing coating as per manufacturer specification-With following steps :- (a) Suface preparation:- Providing and cleaning of concrete surface to remove dust, iol, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools, complete. Ponding test to be done after pugging all outlets and to be cheded from soffit to identify seepage, ladkage. On indentification of seepage, cement grouting to be done with non shirnk expanding admixture of Sika India Pvt. Ltd. / MYK Schombeg/Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints usch as those between the parapet wall and the roof slab etc. Shall be chamfered with '150mmX'150mm fillet lf mortar (Cement sand- 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or requivalent Before chamfering a prime coat shall be give with the slurry of acrylic polymer Reparing surface irregularities, damaged concretein base slab, dead cracks if any, with and acrylic polymer modified reqpair mortar including a coat of bonding agent of the same with cement slurry including all materials labour, tools, complete. (b) 1st Coat :- Apply 1st coat of two component acrylic modidied, ready to use, flexible cementitious material on surface saturated dry roof and inisde wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm oil Fibre glass cloth to lay when the fist layer is still greeb. 1st ciat sgiykd ve aookued @1.50/kg/sqmt/coat for the purpose of measurement the entire treated surface will be measured. (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use flexible cementitious materials right angle to the "1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7kg/sqmt/coat. For the purpose lf measurment the entire treated surface will be measured." alter three days of drying the 2nd coat, the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, teakage from soffit and if found necessary rectification to e be done as per satisfation of E/I. The Watqrproofing Brand: *Sika Topseal 109hi/Fosroc Brushbond RFX/ Dr Fixit Pidiffine 2KI MYK Aqraiin TG Product Performance- Chemical Base Part A.Acrylic copol,mer, Part 13 Specially graded cementitious powder-Density 1.6 kg/l (mixed density) at +270 Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.) 4624) Slant-shear Bond Strength-4 N/mm2 (According to FIP 5.15) Flongation at Break- 35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTMD 2370) D Protection of treated with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in altematepanels lf 2mtx2mt keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS2645@ of 100 ml perbag of cement to be added in the screed concrete (paid separately for this items) all corners shal be charfered with 150mmx150mm fillet. The rain water outlets shal be just leveled with the scree concrete to ensure smooth descharge of water- the perpheral gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensisive epoxy putty of Sika India Pvt.Ltd./IVIYK Schomberg/Dr Fixit / Fosroc. For the purpose of measurement the entire treated surface will be meaured. (e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc (e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc.
Covering of treated surface with PCC :- Providing 25mm thick Cement Concrete M-20 (1:1.5:3) raintaining slope in alternate 2 mix 2mt. Panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing erite nt concrete in mixe with admixture of integral water proofing and placing, position, striking royalty all complete as per building specification and direction of E/I.
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST) brand:- Sika- Polysulphide Fosroc-l-hloflex 600 Dr Flxit Pidiseal PS(42P), MYK seal PS or equivalent.
Providing and fixing on wall face unplasticised rigid P.V.C. rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS:5382 leaving a gap of 10mm for thermal expansion.
Providing and fixing on wall face unplasticised rigid moulded fittings/accesories for unplasticised P.V.C. rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS:5382 leaving a gap of 10mm for thermal expansion. Coupler - 110mm
Providing and fixing on wall face unplasticised rigid moulded fittings/accesories for unplasticised P.V.C. rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS:5382 leaving a gap of 10mm for thermal expansion. Bend - 110mm
Providing and fixing on wall face unplasticised rigid moulded fittings/accesories for unplasticised P.V.C. rain water pipes confirming to IS:13592 Type-A including jointing with seal ring confirming to IS:5382 leaving a gap of 10mm for thermal expansion. Shoe (plain) 110mm
Providing and fixing unplasticised P.V.C. clips of approved design to unplasticised P.V.C. rain water pipes by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including brick work and fixing in cement mortar (1:4) (1 cement : 4 coarse sand) and making good the wall etc. all complete. 110mm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved mak+B50e conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed Portion : Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.0 mm thickness
Providing and laying water proofing treatment to vertical and horozontal surfaces of depressed portions of W.C., kitchen and the like consisting of (i) Ist coarse of applying cement slurry @4.4 kg/sqm. mixed with water proofing compound 'Impermo' of Sowcem or equivalent confirming to IS:2645 in recommended proportions. (ii) IInd coarse of 20mm cement plaster (1:3) (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) IIIrd coat of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. (iv) IVth coarse of 400 micron thick PVC sheet overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen at 1.7 kg per sqm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Carriage of materials by diesel truck including loading at source, unloading at work site and stacking properly, labour etc. all complete as per direction of E/I. Cement
Stone Chips
Steel
Bricks
Sanitary Work Providing and fixing male ended 15mm dia brass bib cock of approved quality (weight not less than 350 gms.) with extra socket all complete as per specification and direction of E/l.
Providing and fixing N.P./C.P. brass/P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l. Shower Rose-125 mm
Providing and fixing 15mm size C.P. brass pillar cock (wt. not less than 350 grams) C.I. body brass spindle pillar cock of approved quality all complete as per specification and direction of E/I.
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/l. (A) BRASS STOP COCK - 15mm dia
Providing and fixing G.M. non-return valve horizontal/vertical type of approved quality as per specification and direction of E/I. Horizontal-25 mm Dia
Providing and fixing G.M. non-return valve horizontal/vertical type of approved quality as per specification and direction of E/I. Horizontal-32 mm Dia
Making holes in walls for G.I. pipe and restoring the same all complete as per specification and direction of E/I. 125 mm thick wall
Making holes in walls for G.I. pipe and restoring the same all complete as per specification and direction of E/I. 250 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. Mirrors of 4mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings, 3mm plywood board and C.P. hinges to fix with mirrors. Mirror (300 x 450mm)
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. C.P. brass towel rail 20mm x 600mm with bracket container
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. C.P. brass shop dish container medium quality with screw and hinges etc.
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. "p" trap 15 liters C.I. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 gms. 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved apint over a coat of red oxide primer etc. all completeas per specification and direction of E/l. With 10 ltr. low level P.V.C. cistern
Supplying, fitting and fixing 40mm high viterous white glazed earthen E.W.C. with "p" trap of approved ISS make including supplying ans fixing 15 P.V.C. flushing cistern of approved make with complete fittings, C.I. brackets with telescopic flush pipe with brass coupling and plumbers joints spindle with stop cock of approved quality weight not less than 450 gms. 15mm P.V.C. alkathene pipe pipe 45cm long with brass coupling at both ends and white black plastic solid state seal and lead of ISS make with hinges or screw etc. painting pipe and cistern etc. with two coats of approved paint over a coat of red oxide primer all complete as per specification and direction of E/l. With 10 ltr. low level P.V.C. cistern
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin with C.I. or M.S. brackets 15mm C.P. brass pillar tap Kingston/Gem/Techno/Ponco 2mm C.P. brass waste of standard pattern including painting and fitting of brackets, cutting and making good the wall wherever required - Flat back wash basin size 550 x 400mm with single 15mm C.P. brass pillar tap
Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive off all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges - Special typr of C.P. Bathroom fitting for V.I.P. building (JAL, Jaguar, Marc or equivalent mark) Angular stop cock / 2 way bib cock
Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive off all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges - Special typr of C.P. Bathroom fitting for V.I.P. building (JAL, Jaguar, Marc or equivalent mark) Angular stop cock / 2 way bib cock Telephonic Shower flexible pipes
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door-75 x 75 x 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door-110 x 110 x 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 75 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer pipe
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked , with cover and suitable lackingarrangement and making necessary holes for inlet , outlet and overflowpipes but without fitting and the base support for tank.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group C
Wiring for twin control point with 1.5 sq. mm PVC insulated aluminium conductor cable in surface conduit including painting etc. as required.
Wiring for 3 pin 15 amp. plug point with 1.5 sq. mm PVC insulated aluminium conductor cable in surface conduit including providing and fixing 3 pin 5 amp socketed outlet on switch board earthing the 3rd pin, painting etc. as required.
Wiring for sub main with following size PVC insulated aluminium conductor cable of surface conduit including painting etc. as required. 2x1.5 sq mm + 1x1.5 sq mm earth wire
Wiring for sub main with following size PVC insulated aluminium conductor cable of surface conduit including painting etc. as required. 2x2.5 sq mm + 1x2.5 sq mm earth wire
Wiring for sub main with following size PVC insulated aluminium conductor cable of surface conduit including painting etc. as required. 4x6 sq mm + 2x6 sq mm earth wire
S/F Piano type switch socket Supplying and fixing following piano type switch /socket on the existing switch box/ cover including connections etc. as required. 5/6 amps, one way switch
S/F Piano type switch socket Supplying and fixing following piano type switch /socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp, socket
Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as required. 100 Amps
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, "B" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
S/L 8 SWG G.I. wire in ground :- Supplying and Laying 8 SWG G.I. wire at 0.50 meter below ground level for conductor earth elecrode , including soldering etc. as required
P/F 25 x 5mm Copper earth strip in pipe :- Providing and fixing 25mm x 5mm copper earth strip in 40mm & 4.5 Mtr long G.I. pipe for earth elecrode etc. as required
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Providing and fixing of XLPE, Aluminium Armoured PVC cable confirming to IS IS7908 (Part-1) 1988 of grade 1.1KV. Make :- Havells /Finolex/ polycab 1 R for each floor separately,3.5 core 50 sq. mm 1.1 KV XPLE AI. Ar cable from main LT panel to VTPN L.D.B Panel.
Supply of 9/10 watt LED Bulb
Supply of LED Batten (20/22W)
Supply fitting fixing of recess Mounting LED Round Down light (12W)
Supply fitting fixing of Bulk head fitting with 9/10 watt CFL/LED
Supply of LED Street light (45/48W)
Supply and installations of celling fan 48'' (1200mm)
Supply fitting fixing and testing of 12'' (300mm) metal exhaust Fan
Supply and installations of wall mounted fan 16'' (400mm)
GST 12% will be added on Total amount quoted by Contractor
Labour Cess 1% will be added on amount quoted by contractor including 12% GST.
M/S S. K. B. R. A. CIVIL AND MECHANICAL CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Termscondition.pdf
Tender Documents • 0.06 MB
BOQ_92358.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .