Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹6.3 L+₹40,023 (6.77%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹7.5 L+₹1.6 L (26.7%)Rejected-Finance 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | L3 | Rejected-Finance Not being lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical WLR No Remark |
Tender Value
₹8.0 L
EMD Value
₹16,060
Closing Date
26 Sept 2023, 6:00 pmClosed
GE PANAJI
GARRISON ENGINEER OPPOSITE KALA ACADEMY ST INEZ ROAD PANAJI GOA 403001
REPAIRS REPLACEMENT OF STREET LIGHTS AREA LIGHTINING PCC POLES UG CABLES AND CONNECTED WORKS AT MARGAO AND PONDA UNDER GE PANAJI GOA
2023_MES_616177_1
8997/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PANAJI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER PANAJI
₹16,060
Yes
29 Dec 2023
29 Aug 2023
28 Sept 2023
29 Aug 2023
26 Sept 2023
12 Sept 2023
29 Aug 2023 - 5 Sept 2023
Amount
Attending of street/ security lights complaints received through telephone or in person and rectification of defects in street lights like , LED street light, post top lamp, Flood light fittings etc of any make, installed on street light poles 9/ 11 metres long, buildings, walls, roof by bringing down the fittings on ground or in position by replacing unserviceable items including cleaning of glass etc, further replacement of old unserviceable street light fittings with new fittings complete all as specified and as directed. (Contractor will provide ladder, tools required at site): - Note: -(i)LED light fittings replaced shall be measured and paid separately under respective items (ii) Complaints shall be attended and rectified within 24 hrs of receipt of complaint. (iii) Lights on one pole repaired shall be treated as one complaint.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation laying of pipe line etc and getting out in hard/dense soil complete all as specified and as directed.
Returning filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed
Removing excavated surplus hard/dense soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
Supply and laying DWC HDPE pipe of outer dia of 50 mm and inner dia of polyethylene (PE) with smooth internal and profiled external surfaces for non pressure for underground cable including bends complete all as specified and as directed. Make :REX POLYEXTRUSION LTD/ ASTRAL /FINOLEX /SUPREME /PRINCE
Fixing only XLPE insulated heavy duty electric cable of size 6 sq mm 2 core with aluminium conductor, 1100 volts grade for necessary connection with suitable lugs & fixing arrangement with necessary clamps & cable glands etc complete all as directed & specified after removing the old/damaged cable.
All as in Item No. 6 above but for cable of size 10 sq mm 2 core
Supply and connecting armed service wire 2.5 sqmm 3 core complete all as specified and as directed.
Supply & Installation of SMC terminal/junction box of size 200mm x 140mm x 95mm of polycarbonate thermoplastic housing, weather, water proof fire retardant including 02 Nos terminal complete all as specified and as directed. Make : Sintex/National
Supply and fixing 25 mm dia galvanized iron mild steel tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc complete all as specified and as directed.
Supply and fixing 40 mm dia galvanized iron mild steel tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc complete all as specified and as directed.
Supply only post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with implact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply only new generation, energy saving, garden light environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape lumanire for diffused lighting with high power LED as light source complete all as specified and as directed. Make: Havell's Cat No BAMBOOBLS8WLED830PSYMTOPC (0.6 M)
Supply only LED flood light 70 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make: BAJAJ/ HAVELLS/ PHILLIPS/TATA/CROMPTON
Supply only LED street light fitting 60 watt 230 V AC outdoor type with hight pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed. Make: BAJAJ/ HAVELLS/ PHILLIPS/WIPRO/CROMPTON
Material and labour for bracket made out of GI pipe 40/32 mm dia medium grade, 1.2 meter long bent to shape fixed with MS flat iron clamps made out of 40mm x 6 mm thick, nuts bolts complete all as specified and directed.
Material and Labour for cement concrete as in foundation 1:4:8 type D2 using 40 mm graded stone aggregate filling and mass concrete complete all as specified and directed.
Material and Labour for cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including woathoring, slightly rounded or chamfered angles and threating, complete all as specified and directed.
Supply & Fixing of automatic Street Light using Nature switch for automatic switching of street lights based on LUX level of nature light. The infrared sensor based nature switch along with lighting load of 5 KW, single phase with suitable power contactor (AC 1) and MCBs of suitable rating should be enclosed in pole/wall mountable enclosure made of rust proof, termite proof and FR grade SMC junction box conforming to IP 54 fixed to pole by MS clamps fabricated out of 25mm x 3 mm thickness suitable to PCC /steel tubular poles, bolts and nuts as required at sight and connected to street light over head/ under ground feeder by using suitable twin core aluminium conductor and complete all as specified and as directed. Make : Swadeep- 02 EC of Kakatiya Energy System or equivalent in CG
PREETI ENTERPRISES
elite enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .