Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1Accepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹2+₹1 (100.0%)Rejected-Finance 210 211 2ND FLOOR NEW UDYOG MANDIR NO 2 PT SATAVALEKAR MARG MOGHUL LANE MAHIM WEST MUMBAI MAHARASHTRA 400016 | MUMBAI | MAHARASHTRA | 400016 | L2 | Rejected-Finance L2 | |
| 3 | L3₹3+₹2 (200.0%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹4+₹3 (300.0%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
Closing Date
11 Jan 2021, 5:30 pmClosed
Executive Engineer, P.W. Division Thane No. 1
Executive Engineer, PW Division, Thane no 1 , PWD Compound, Station Road, Thane (West)- 400601
Construction of 574 beded Civil Superspeciality Hospital and Nurses Quarters at Civil Hospital Complex Thane
2021_PWR_633357_1
NIT_NO_OW_6247_FOR_2020_21
Open Tender
Civil Works
Item Rate
15 days
Thane
As Per Tender Documents
3 documents required · 3 mandatory
₹0
Exempted
8 May 2024
4 Jan 2021
14 Jan 2021
4 Jan 2021
11 Jan 2021
4 Jan 2021
Amount
Sub Work No-1
Supplying, erecting & terminating XLPE unarmoured cable 1 core 185 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE unarmoured cable 1 core 300 sq. mm. aluminium conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE unarmoured cable 1 core 120 sq. mm. aluminium conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE unarmoured cable 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CB-LT/CU
Providing & erecting Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 600 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. (NDSR)
Providing & erecting Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 750 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. (NDSR)
Providing & erecting Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 1000 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. (NDSR)
Providing & erecting Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm thick) GI sheet of 600 mm width & 100 mm height comprising all required standard Acessories. (NDSR)
Providing & erecting Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm thick) GI sheet of 750 mm width & 100 mm height comprising all required standard acessories. (NDSR)
Providing & erecting Hot deeped Galvanised Ladder Type Cable Tray manufactured from 16 swg (1.6 mm thick) GI sheet of 1000 mm width & 100 mm height comprising all required standard acessories. (NDSR)
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (NDSR)
Providing & erecting 4 Pole MCCB upto 125A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (NDSR)
Providing & erecting 4 Pole MCCB upto 160A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (NDSR)
Installation & commissioning of UPS, 3 x 3, 200 kVA @ 25°C, 3 Phase, 415 V, IP-20, including Transformer with Parallel Connection Cable (8M) for 200 kVA with Inbuilt Output Transformer with UPS, Battery Circuit Breaker -External , Approved make SMF 12V battery 40 blocks,1 set of 200Ah with 10min Backup, Battery Rack,Battery IRIT, Nyvin Cable Size 2x00 (Idc=417Amps,UPS to battery standard distance 10 mtr) & Uninyvin cable size 0000 for (6W+3SB) UPS system (O/P current:278Amps)
Installation & commissioning of UPS, 3 x 3, 120 kVA @ 25°C, 3 Phase, 415 V, IP-20, with Transformer including Parallel Connection Cable (8M) for SX 66-220 kVA , Inbuilt Output Transformer with UPS ,Battery Circuit Breaker -External, make SMF 12V battery 40 blocks,1 set of 120Ah with 10min, Backup Battery Rack ,Battery IRIT, Nyvin Cable Size 0000(Idc=333Amps,UPS to battery standard distance 10 mtr) & Uninyvin cable size 2 for (2W+1SB) UPS system (O/P current:166Amps)
Supply, Installation, Testing and commissioning of UL Certified / CPRI Tested Maintenance Free Earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron Molecular Copper Bonded Earthing Rod of Length 3m along with 25 kg Carbon Based environment friendly back fill Ground Enhancing compound required to fill up the excavated earth with required quantity as per specification no EA-MOBI
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 55 )
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Outdoor ( IP 65 with canopy )
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Flange End – Provision
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Copper Flexible (RYBN)
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Adaptor Box
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Expansion Joint - Provision
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 3200A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 55 )
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Outdoor ( IP 65 with canopy )
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Flange End – Provision
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Copper Flexible (RYBN)
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Adaptor Box
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Expansion Joint - Provision
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 2500A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 2000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 1600A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 1250A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 1000A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 800A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthingStraight Length – Indoor ( IP 55 )
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Outdoor ( IP 65 with canopy )
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Flange End – Provision
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Copper Flexible (RYBN)
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Adaptor Box
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthingPhase crossover - Provision ( If Reqd.)
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Expansion Joint - Provision
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 630A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Straight Length – Indoor ( IP 54 ) with plug in point provision
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing 90 Deg Bend – Provision
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Tee Bend – Provision
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Spring/rigid hangers
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Supports/Brackets
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Phase crossover - Provision ( If Reqd.)
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing Reducer - Provision (Direct type)
SITC of 400A, 4P, 415V Sandwich Aluminium Bustrunking with 2 Runs Of 50x6mm Aluminium earthing End Cover
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs630A, 35KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs500A, 35KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs400A, 35KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 315A, 35KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 250A, 25KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 200A, 25KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 160A, 25KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 125A, 25KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 100A, 25KA, FP MCCB
SITC of C&S make Tap off boxes with C&S/Schneider/L&T make Thermal magnetic based O/C, S/C release MCCBs 40A, 25KA, FP MCCB
SITC of 2000 KW / 2500 KVA standard Diesel Generating Sets comprising of : "Cummins" Model KTA-38-G5 Radiator Cooled, Diesel engine developing 1180 BHP at 1500 RPM, complete with standard accessories. coupled to Alternator rated at 2000 KW / 2500 KVA at 415 Volts,mounted on : Channel Iron Base Frame complete with : Fuel Tank of 990 Ltrs. Capacity with 2 Nos. 12 V Batteries and manual control panel.
SITC of DG Acoustic Enclosure made up of Mild Steel capable of reduction of 70 to 75dB using Rockwool as acoustic insulation of 64/96 Kg m3 density mininum 100 mm thick panels of suitable colour coated on the surface.
S.I.T.C. of 10 KVA Isolation Panel for Operation theatre Isolated Power Distribution Panel Panel with 12 Nos 20 A, DP MCBs Ammeter, Voltmeter & Lamps with 63 A I/P, O/P, MCB’s, channels, wiring material etc.Size Approx: 1800 X 650 X 400 SIEMENS Grey Powder coated 14 SWG with 3 Doors andTransparent Sheet. consisting following & Work contract for Provision of Ungrounded supply as per BIS SP30 2011 India Part 3,Section 4: Medical Establishment with the following scope:a) Supervision for Installation & Commissioning at Siteb) Testing of the panel at Sited) Training to your personnel at Site. scope of work consist of.1.Insulation Monitor#1 Nos ,2.Load CT #1 Nos ,3.Isolation Transformer 10 KVA #1 Nos.,4.12 Channel Scanner# 1Nos.,5.CTs # 12 Nos.,6.Remote Indicator#1 Nos.7.AN450 #1Nos. with Charges towards CMC of Medical Isolation panel for 3 years from the date of issue of Work Order (The contract period for the CMC of Medical Isolation panel shall be of 3 years from the date of issue of Work Order to the contractor and after completion of warranty period of 1 year)
SITC of Oxygen Outlet-1 +Vaccum Outlet-1+ Medicle Air Outlet-1+15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Vaccum Outlet-2 +Oxygen Outlet-1+Medicle Air Outlet-1+15 Amp Switch Socket 2 Nos.+5 Amp Switch For Inspection Lamp. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Oxygen Outlet-2+ Vaccum Outlet-2+ Medicle Air Outlet-3+15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Oxygen Outlet-2+Vaccum Outlet-3+Medicle Air Outlet-1+15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Oxygen Outlet-2+ Vaccum Outlet-3+ Medicle Air Outlet-1+Nitron Oxide Outlet-1+Medicle Air 7 Bar-1+15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Oxygen Outlet-1+ Vaccum Outlet-1 + 15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Oxygen Outlet-1+ Vaccum Outlet-1+ Medicle Air Outlet-1+ Nitron Oxide Outlet-1+ 15 Amp Switch Socket 2 Nos. Medical Terminal Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.
Design, manufacture, supply,including supervision during installation, testing and commissioning of the following extensible cubicle type indoor mounting, dead front, fully compartmentalised with hinged lockable detachable front & back openable, dust and verminproof, floor mounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 433 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of suitable KA at 433 volts. Panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition. All incomer breaker shall be interlocked electrically as shown in SLD and specifications. The following provisions shall be required to be made in the switchboard as detailed below:The Switchboards shall have provision to accommodate all cables from the bottom /top as required.All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards.Suitable Aluminium earth bus to be provided throughout the length of Switchboards.ll indication lamps / illuminated push buttons shall be LED type.
SITC of Automatic OHT Level Control system (Solenoid Valve PGV Model - 2Yrs Warranty + Level Float Switch + Controller) - Automatic OHT Level Control system Consists of following items. 1.1) Solenoid Valve, MOC: Plastic, Pilot Operated Diaphragm Type Screwed end (PGV Model -2 Year Warranty) with IP65 Coil and Manual Override. 1.2) 10 Mtr level Float Switch, 1.3) 24V Control Box with indicator.
SITC of Air Admittance valves with Aluminium cover, Polystyrene cover cap, ABS body, Synthetic rubber memberane & rubber connector suitable for Airflow capacity upto 32 l/s operating temperature (-20Deg Celcius to +60 Deg Celcius) complete on Drainage stack to avoid vent piping with all necessary fittings and supports.
SITC of Air Admittance valves with Aluminium cover, Polystyrene cover cap, ABS body, Synthetic rubber memberane & rubber connector suitable for Airflow capacity upto 7.5 l/s operating temperature (-20Deg Celcius to +60 Deg Celcius) complete on Drainage branch with all necessary fittings and supports.
SITC of 2 Way Actived carbon filter 100 / 110 mm dia for Inddor and Outdoor application, made up of ABS body, rubber connector & Replacable Activated Carbon Cartridge suitable for Airflow capacity upto 2 to 8 l/s at 100 to 500 pa operating pressure,operating temperature (-20Deg Celcius to +60 Deg Celcius) complete with all necessary fittings and supports.
SITC of (250 KLD STP+ ETP ) Only Mechanical System for MBBR + ETP Technology with Tertiary Treatment comprising of Media & Carbon Filter System.Consisting of Synthetic Media For GREWA-B (MBBR ) , Synthetic Media For Tube Settler, Sludge recycle pump, Filter press feed pump, Filter press, Hypo Dosing Pump With Tank, Alum Dosing Pump With Tank & Electrical Control Panel.
SITC of SS 316 Automatic Centralized Ultra Voilate Water Filter cf 18 m3/hr Capacity suitable for maximum pressure of 20 bar,240 Grit (0.42 Ra Micron (µm)) Internal Surface Finish with low pressure amalgam (LPAM) lamp technology for maximum power density & efficiency, with all neceaasry control indication and Alarm.
SITC of SS 316 Automatic Centralized Ultra Voilate Water Filter cf 25 m3/hr Capacity suitable for maximum pressure of 20 bar,240 Grit (0.42 Ra Micron (µm)) Internal Surface Finish with low pressure amalgam (LPAM) lamp technology for maximum power density & efficiency, with all neceaasry control indication and Alarm.
Sub Work No-2
Supply & commissioning of microprocessor based 10 loop UL Listed depending upon the loop capacity, networkable Analogue Addressable Fire Alarm Control Panel with Minimum 200 W to 900 watts digital audio amplifier(s), 8 zone speaker circuits and necessary provision / card to connect 2-way talk back fire fighter's riser. The FACP shall have minimum 80-960 character display with fully functional QWERTY keypad. Each loop shall have aminimum 99 detectors and 99 devices or maximum 159 detectors and 159 devices in one loop. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. The FACP shall be UL 9th edition Listed including network communication module with true peer to peer connectivity. The amplifiers shall be digital audio amplifiers. Power / Analog amplifiers shall not be permitted. The speaker circuits (Zones) shall originate directly from the amplifier terminals.Use of control modules for zoning shall not be permitted. There shall be provision to connect the 2-way Talk Back system riser. Failure of fire alarm panel CPU shall not result in failure of operation of Amplifier. Hence if the digital audio amplifiers are CPU rail mounted, consider 1 no. CPU dedicated for every 400 Watts digital audio amplifier bank. FACP shall be inclusive of all necessary cards, modules, enclosure, CPU and associated accessories to complete the system design. All components including enclosure shall be UL Listed.
Supply & commissioning of microprocessor based 6 loop UL Listed depending upon the loop capacity, networkable Analogue Addressable Fire Alarm Control Panel with Minimum 400 W to 900 watts digital audio amplifier(s), 8 zone speaker circuits and necessary provision / card to connect 2-way talk back fire fighter's riser. The FACP shall have minimum 80-960 character display with fully functional QWERTY keypad. Each loop shall have aminimum 99 detectors and 99 devices or maximum 159 detectors and 159 devices in one loop. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. The FACP shall be UL 9th edition Listed including network communication module with true peer to peer connectivity. The amplifiers shall be digital audio amplifiers. Power / Analog amplifiers shall not be permitted. The speaker circuits (Zones) shall originate directly from the amplifier terminals.Use of control modules for zoning shall not be permitted. There shall be provision to connect the 2-way Talk Back system riser. Failure of fire alarm panel CPU shall not result in failure of operation of Amplifier. Hence if the digital audio amplifiers are CPU rail mounted, consider 1 no. CPU dedicated for every 400 Watts digital audio amplifier bank. FACP shall be inclusive of all necessary cards, modules, enclosure, CPU and associated accessories to complete the system design. All components including enclosure shall be UL Listed.
Supply & commissioning of microprocessor based 4 loop UL Listed depending upon the loop capacity, networkable Analogue Addressable Fire Alarm Control Panel with Minimum 200 W to 900 watts digital audio amplifier(s), 8 zone speaker circuits and necessary provision / card to connect 2-way talk back fire fighter's riser. The FACP shall have minimum 80-960 character display with fully functional QWERTY keypad. Each loop shall have aminimum 99 detectors and 99 devices or maximum 159 detectors and 159 devices in one loop. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. The FACP shall be UL 9th edition Listed including network communication module with true peer to peer connectivity. The amplifiers shall be digital audio amplifiers. Power / Analog amplifiers shall not be permitted. The speaker circuits (Zones) shall originate directly from the amplifier terminals.Use of control modules for zoning shall not be permitted. There shall be provision to connect the 2-way Talk Back system riser. Failure of fire alarm panel CPU shall not result in failure of operation of Amplifier. Hence if the digital audio amplifiers are CPU rail mounted, consider 1 no. CPU dedicated for every 400 Watts digital audio amplifier bank. FACP shall be inclusive of all necessary cards, modules, enclosure, CPU and associated accessories to complete the system design. All components including enclosure shall be UL Listed.
Supply & commissioning of UL Listed serial outlaying Annunciator (Repeater Panel) with 640 Character Display and fixed function keys and soft keys. The serial Annunciater shall repeat the signals from the entire FACP network complete etc. as required.
Supply & Commissioning of Fire Command Station including Graphical User Interface (GUI) Software. The GUI based main network software shall be capable of graphically representing each node being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room and shall monitor all the blocks panel connected with each other. The software shall provide the facility to Monitor, Control all the Digital Voice Evacuation as well as 2 way communication from main control room using voice signals over peer to peer Network along with the Fire detection signal.The Software item should include the price of PC operator worstatikon intel - I5 processor + 4 GB ram + 500 GB hard disk + DVD writer + 21" LCD Monitor + Latest window version + USB Keypad + USB Mouse + A4 color Laser Printer suitable configuration for software. The Graphic workstation shall act as an independent node communicating on the peer to peer true peer to peer network and shall not be dependent on the Fire Panel CPU for operation (failure of any CPU shall not result in failure of Graphic Workstation).
Supplying, installation, testing and commissioning of Optical type Addressable smoke Detector with twist lockable removal base with connector for loop in and loop out, insect resistant screen and rotary/binary decimal switch, built - in tamper resistant features including connections etc. as per specifications complete as required.
Supply & commissioning of Analog Addressable type Self Acclimatising Multi Sensing (Photo + Heat) detector with standard mounting base, LED, address switch, complete with MS Powder coated Junction Box for mounting on Surface / on False Ceiling / Below False Floor, Cable lugs at end, cable compression glands, cable tags and ferruling and as per attached specification etc. as required.
Supply & commissioning of Analog addressable rate of rise cum fixed temperature heat detector with standard mounting base, LED, address switch, complete with MS powder coated Junction box for mouting on surface / on false ceiling / below false floor, cable lugs at Ends, cable compression glands, cable tags and ferruling and as per attached specification etc. as required.
Supply & commissioning of Laser Ultra-High Sensitivity Smoke Detector - Very early warning fire detectors with required accessories.
Supply & commissioning of LED Type Response Indicator (RI) having two nos red colour LED lamp with matching screws complete with GI Junction box, Cable lugs at cable end and ferruling etc. as required.
Providing, installing, testing and commissioning of UL Listed addressable beam detector with 4 manual & 2 automatic senstivity settings with addressable relay to programme the detectors complete as per specification.
Supplying Installation Testing & Commissioning of Analog Addressable Duct Mounted Photo Electric Smoke Detector with Duct Housing,Sampling tube,mounting base, Addressable switch and all other accessories ,complete with cable lugs,glands etc as required
Supply & commissioning of UL Listed Analogue Addressable Dual Action Manual Pull Stations with address switch and all mounting accessories complete and as per attached specifications complete etc. as required.
Supply & Commissioning of 2 way communication Fire Fighter's Telephone Jack fitted on wall including the cast of breaking and making good the wall wherever required, complete in all respects as per specifications. (UL 9th Edition Approved and NFPA compliant) complete as required.
Supply & commissioning of UL listed Addressable Monitor Module with address switch in suitable enclosure as per attached specifications complete etc. as required.
Supply & commissioning of UL listed Addressable Control Module with address switch for Hooters cum Strobes and for other devices as may be required, in suitable enclosure as per attached specifications complete etc. as required.
Supply, installation of fault Isolator Module as per attached specifications complete etc. as required. Description Isolator Module - factory set hardware type code Address Requirements Uses One Detector Address Circuit Resistance Six ohms maximum between isolators Operating Current Standby = 45µA; Activated = 45µA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction & Finish High Impact Engineering Polymer 2-gang front plate - White Finish Storage Environment Temperature: -4°F to 140°F (-20°C to 60°C)
Supplying & commissioning of Directional Sounders with 20 Hz to 20 kHz operating frequency with minimum 8 distinct sound patterns to indicate corridors, Exit doors, Move upward, move downward etc. to direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2010 edition with control modules as per attached specification complete as required.
Supply & commissioning of Ceiling / Wall Mounted Muli-Candela Strobe with all required accessories for mounting complete as required.
Supply & commissioning of Ceiling / Wall Mounted Voice Evacuation Speaker having power taps upto 2W and frequency response of 400 to 4000Hz for Voice Evacuation and as per attached specifications complete etc. as required
Supply & commissioning of Horn Type 30Watt Loud Outdoor Speaker with all required accessories for mounting complete as required.
Supply & commissioning of DVD Player with 5 DVD Changer. HDMI one cable connection 1080p upscale ; Record to USB and USB content playback Multi disc and format playback PhotoTV HD ; Power Requirements 110-240V, 50 / 60Hz and Power Consumption (Standby) less than 0.5 W Fast and slow playback with sound ; Speaker Surround Sound Channel Configuration is 5.1
Supply & commissioning of Volume Control Device for Cabins. u 12 W, 36 W and 100 W versions u Available in power-save or failsafe versions u Built-in 24 VDC override relay u Continuous rotating system u Suitable for 3-wire and 4-wire systems
Supplying and laying cables for signal initiating devices, control, monitor & fault isolator consisting of of 2 C x 1.5 Sq.mm FRLS CU armoured CABLES shielded (Signal, supervised power, voice, strobes,telephonic & spare) from fire panel to the all devices in loops.
SITC of 2 MP IR Dome 4MM, 2 MP (1980 x 1080) high resolution, Full HD1080p real-time video, Up to 30m IR visibility, IP66 rating, Vandal-proof housing
SITC of 32CH NVR DS-7732NI-E4 Third-party network cameras supported, Up to 5 Megapixels resolution recording, HDMI and VGA output at up to 1920×1080P resolution, Up to 4 SATA interfaces
SITC of Netgear 24-port PoE Smart Switch with Gigabit Ports Network Switch Manage all ProSafe Smart Switches from an easy-to-use Web console that can be used to configure all features, as well as monitor and trouble-shoot. These switches also have SNMP (v1, 2 and 3) to collect and track data to monitor the network health, as well as manage devices, and more easily enforce critical IT controls and policies. SNMP v2c is most commonly deployed, as it provides better reporting capabilities than SNMP v1.
SITC of Western Digital AV-GP 4TB Hard Disk Surveillance Video Hard Disk (Rec. 1.3MP 10Days) ( Rec. 3MP 6Days) Improve performance with All Frame for up to 32 HD cameras Surveillance storage for peace-of-mind 4TB capacity 3.5-inch internal hard drive 64MB buffer size
SITC of CAT6 cabling with conduit & Laying Charges • 4 Pairs Unshielded Twisted Pair (UTP) Cable • Conductor Metal: Solid Bare Copper • Color Code: Gray • Conductor Diameter: 0.560mm Nominal, 23 AWG • Insulation Diameter: 0.970mm Nominal, Insulation Material: HD-PE • Jacket Material: PVC UL94V-0/LSZH • Cable Diameter: 6mm Nominal • PE Central Cross separator
SITC of Accessories & Brackets for Mounting Cameras (BNC pin, DC pin, PVC BOX )
SITC of 9U Wall Mounted Rack, 600W - 600D Rack Mounting Hardware Packet { Containg 1 Nos Each Of 3 } - 10 Set Fan Metal Cable Manager - 01U 06 Socket - 5 Amp PDU
SITC of SPEED DOME CAMERA 1920 x 1080 Resolution at Up to 30 fps IR Range Up to 66' 2.8-12mm Varifocal Lens 100-25° Field of View PTZ Functionality Two-Way Audio with Built-In Microphone RJ45 Ethernet with PoE Technology microSD Slot Supports Up to 128GB ONVIF-Compliant, Profiles S & G
SITC of SPEED DOME JOYSTICK NETWORK CONTROLLER 128 x 64 screen l 4-axis joystick l Connectable to the Multi-functional Video Center (MVC), Matrix Access Gateway (VAG), Video Wall Controller, Decoder, etc.; and shortcut operation of camera/camera groups switch on video wall l Connectable to dome and realize PTZ control and picture capture by joystick operation l Connectable to DVR via network or serial port, and operation of front panel buttons l 16 user accounts management: 1 admin and 15 operators l System upgrade and import / export of configuration files by USB-flash disk l Captured pictures(FAT32) can be stored in U-flash disk l Network access and configuration by Web browser support; and up to 1000 devices can be managed in the keyboard operation mode
SITC of polycob 3 core fixible power cable conduit & Laying Charges.( Use to PTZ Power Supply)
SITC of 24 port patch panel (molex) loaded & termination 24 Ports 1U EIA 568A/B wired ETL verified Standard 19" rack mount IDC contacts that flex not fatigue when terminated Pointed IDC towers to speed termination and enhance cable retention Integral cable management shelf ensures bend radius compliance Individually removable patch panel ports
SITC of Rj45 connector & termination (camera end side)
SITC of 6 core molex Armoured indoor 50/125m, Multimode Fiber optic cable om3 & HDPE PIPE. (Laying Charges)
SITC of 12 Port rack mount LIU loaded with SC Coupler Panel & Splice Holder (Molex)
SITC of Fiber core spliceing with OTDR
SITC of MOLEX Cat6 1 mtr patch cord 4 pair 24 AWG stranded copper wire n Pre-terminated with WE8W plugs n Slim clear anti-snag slip on boots n Suitable for EIA 568A or 568B wiring n LS0H sheath n RoHS Compliant
MOLEX Cat6 2 mtr patch cord 4 pair 24 AWG stranded copper wire n Pre-terminated with WE8W plugs n Slim clear anti-snag slip on boots n Suitable for EIA 568A or 568B wiring n LS0H sheath n RoHS Compliant
SITC of sc-sc Duplex fiber patch cord MM OM3, 2 Mtrs optical Multimode 3 (OM3) fiber supporting 2000 MHz.km EMB at 850 nm
SITC of TP-Link MC 200m Gigabit Multi-Mode Media Converter
SITC of 42U Rack 800w x 1000D with Accessories Front Glass Door- 800w, Rear Door-800w, Side Panel- 1000D(2), Fan-AC-90Cfm, Power Dist ribution Unit 06/16 Amp with Socket Single Pole 16 Amp MCB
SITC of 24 Port rack mount LIU loaded with SC Coupler Panel & Splice Holder (Molex)
SITC of 1U CABLE MANAGER - Hinged light weight aluminium cover matches horizontal cable manager look and helps to maintain clean quiet front of rack appearance, Facilitate neat patch cord through style routing between racks, Deep and wideplastic fingers support bend radius and enable dense fill rate between patch panels
SITC of HDMI Cab;e (TV to NVR) Audio/video interface for transmitting uncompressed video data and compressed or uncompressed digital audio data from an HDMI-compliant source device, such as a display controller, to a compatible computer monitor, video projector, digital television, or digital audio device.
SITC of Access point Nano-Station Loco M5: Compact and cost-effective AirMax 5GHz CPE, Atheros MIPS 24KC, 400MHz, FCC Part 15.247, IC RS210, CE, RoHS Compliance
SITC of Molex CAT6 cabling with PVC conduit & Laying Charges
SITC of Supply installation Molex Cat6 I/O & Termination. Jack connector, Plastic Housing Polycarbonate, UL94V-0 rated or equivakent,Operasting Life Minium 750 ijsertion cycles, Contact Material Copper Alloy, Contact Plating: 50µ” Gold/100µ” Nickel, Contat Force 100 g mminimum, Plug Retention Force 15 lb.
SITC of Supply installation Molex singal face plate & PVC BOX.
Supply Installation Molex Cat6 1 Mtr patch cord (Rack & AP End)4 pair 24 AWG stranded copper wire n Pre-terminated with WE8W plugs n Slim clear anti-snag slip on boots n Suitable for EIA 568A or 568B wiring n LS0H sheath n RoHS Compliant
Supplying, erecting & Commissioning Main Distribution Frame (MDF) Box 2000 Pairs as per specification no WG_TW.
SITC for 3 ay Splitter for Cable TV: Type: 3 way shower diverter Material: ABS HIGH DURABLE Finish: chrome finished Size approx 55x70x20mm ABS universal shower Components Adjustable Shower Arm Mounted Adjustablke shower arm mounted easy to install
SITC for 4 way Splitter for Cable TV: Type: 3 way shower diverter Material: ABS HIGH DURABLE Finish: chrome finished Size approx 55x70x20mm ABS universal shower Components Adjustable Shower Arm Mounted Adjustablke shower arm mounted easy to install
1.Panasonic Digital pabxsystem ,Model:NS1000, Configuration 16co lines expandable ,8 digita Extension expandable ,600 analogextensions expandable to 1000 extentions,Pri line competible,Voicemail and host of unmatch feachers with accessories. .Co line expantion card , Digital line expantion card ,Analog extension card with allied accessories. 2.PBX set up ,Installation,testing and commissioning charges 3.Panasonic key phone phoneDigital PT w 6Line LCD/24 FF Key (for operator) complete PanasonicOperator DSS Console with extension display complete
SITC of For connection module at patient side with countersunk double switchbox.
SITC of patient handset module with cradle for holding the module.
SITC of Pull Cord Module - Toilet call module with countersunk double switchbox and required accessories.
SITC of Code Blue button with countersunk double switchbox and required accessories
SITC of Call/Cancel button - Shower module with countersunk double switch and accessories.
SITC of Nurse Station comprises of: - A colour graphic Touchscreen display, a smash proof glass panel,Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl volume control), automatic changeover between hands-free and discrete speaking, Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, (VoIP, IP Telephone), 2.8m connection cable with an RJ45 connection plug, which is protected from disconnection, for connecting to a connection module.
Supply and laying of specified make UTP CAT6 cable in prelaid PVC conduits / pipes / raceway, but without the cost of raceway or pipe.
Supply & laying of 25 mm dia. Open/conceal manner heavy guage rigid PVC pipe with GI pulling wire.
SITC of Flyable 8", high power, high sensitivity, 2-way loudspeaker. The speaker cabinet must have frequency range of 48Hz-18kHz, sensitivity (1W/1m) 93 dB SPL or more, delivering Max SPL of 122 dB or more with power handling pk 800W or more. The speaker should have a nominal impedance of 8 ohm .The speaker cabinet should have a horizontal coverage angle of 90 degree, OEM Wall mounting bracket to be included or better.
SITC of 18", high power subwoofer. The speaker cabinet must have frequency range of 35Hz-200Hz, sensitivity (1W/1m) 96 dB SPL or more, delivering Max SPL of 133 dB or more with power handling pk 1600W or more. The speaker should have a nominal impedance of 8 ohm or better.
SITC of Class AB/D/H/I Dual channel power amplifier with specification as below or BETTER to suit the power requirement of proposed speakers; Max Midband Output Power:450W @ 4 ohms,600W @ 2 ohms,Max Bridged Output Power:1300W @ 4 ohms,Frequency Response:20Hz - 20 KHz,THD:<0.03%,Max input level:+21dBu,Crosstalk<80dB,input impedence:20kohm,signal to noise ratio : >110dB ,with built in protection such as Audio Limiters, Temperature, DC, HF Short Circuit, Peak Current protections
SITC of Class AB/D/H/I Dual channel power amplifier with specification as below or BETTER to suit the power requirement of proposed speakers; Max Midband Output Power: 900W @ 4 ohms,1250W @ 2 ohms,Max Bridged Output Power: 2800W @ 4 ohms,Frequency Response:20Hz - 20 KHz,THD:<0.03%,Max input level:+21dBu,Crosstalk<80dB,input impedence:20kohm,signal to noise ratio : >110dB ,with built in protection such as Audio Limiters, Temperature, DC, HF Short Circuit, Peak Current protections
SITC of 8" two way powered stage monitor Loudspeaker : 48Hz - 20kHz, SPL Nominal - Max SPL 123 dB SPL Wideband.Coverage(H X V) 90 X 50 degree.The loudspeaker should have inbuilt amplfier of class D delivering a power of 800W or more.It should have integrated monitor angle on the enclosure for use floor monitor
SITC of Digital Signal Processor with 2 x XLR IN, electronically balanced audio input,6 x XLR OUT, electronically balanced audio output with 2 x XLR Thru out ,and 1x XLR AES/EBU IN digital input,with Nominal Input Voltage:1.23V / +4 dBu, maximum input voltage:8.7V / +21 dBu,input impedence :10k Ohm,CMR:-80dB@1kHz,A/D &D/A coversion :24 bit sigma delta,THD+N <0.01% Approved makes :Electro-Voice, D&B Audio Technik,Martin Audio, Meyer Sound
SITC of 16 channel Mixer with Digital Audio interface with 4 input channel & 4 output channels with AD/DA conversion 24-bit and; USB 2.0 PC Interface, MIDI interface, OLED display;100 Digital effects presets with at least 20 user preset available. 12 mono & 4 stereo channels, 6 auxillary outputs,11 band stereo equalizer;THD(at 1kHz)<0.005%,frequency response(-3dB) :20Hz to 65kHz;crosstalk>85dB,CMRR(at 1kHz)>80dB,Equivalent input noise:-130dBu A, maximum level mic inputs:+21dBu
SITC of Freestanding Gooseneck Mic with base for podium having back electret condensor microphone element ,Hyper Cardioid polar pattern,LED status display and with programmable button for Push to Talk or Push to Mute functions having ,frequency response 50Hz-20kHz ,sensitivity 5.5mV/Pa,clipping level >130dB SPL ,output impendence 200 ohm
SITC of Handheld Wireless Mic with Cardiod polar pattern,Dynamic microphone ,frequency response 80Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 30 or more channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body
SITC of Wireless Mic Lapel with condensor,frequency response 100Hz-15kHz,Cardiod polar pattern,,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 32 channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body
1/2.86-Type 3MOS sensor Full-HD video via 3G-SDI & IP streaming, DRS, POE+ & night mode
Remote Camera Controller Large touchscreen for easy usability, New joystick for one-handed operation Simplified PTZ camera presets and tracing memory Intuitive design elements based on direct feedback from everyday robotic camera operators • 3G-SDI Active Through Output, 5 x RS-422, LAN PoE+, 2 x GPIOs
Half rack size digital video switcher , 5 INPUT : 4 SDI, 1 DVI-D , 3 OUTPUT : 2 SDI, 1 DVI-D , Built-in multiviewer
Handheld HD Recorder with HD-SDI Input / Output, Featuring Versatile Operation and Full-HD Images Use Memory cardsSDHC/SDXC class10 optional not quoted
65 " LED professional display Resolution 3840 x 2160 pixels, 2 x USB, 3x HDMI, Speaker Ouitput 2 x 20 Watts, UHD Engine, Auto Motion Plus, Contrast Enhancer, AC 100 - 240 V, 50/60 Hz Set Size with Stand (WxHxD) 1457.5 x 917.3 x 312.8 mm
36 U Rack - Moducab Front Glass Door, Moducab Rear Door, Monitor Tray - 700D, Mounting Hardware Packet ( Pack Of 20), Metal Cable Manager - 01U, AC Axial Fan - 230V AC - 90 CFM -Assembly ( Set Of 4), Power Distribution Unit - 06/16 Amp Indian-Standard - 10 Socket , Castor - 3 Inch Hight - With Brake - Assembly / Castor - 3 Inch Hight - With , Out Brake - Assembly
SITC of complete cabling as per the manufacturer's speicifcation for the Prosound system and the Camera display system with all required connectros, switchers and accessories
Sub Work No-3
Supply, Installation, Testing & Commisioning of standard response standard coverage sprinkler head with quartz bulb and set to operate at 68°C. wherever required and all accessories, supports and painting etc. (Side wall Type)
Supply & Fixing of rossetteplate for pendant type Sprinkler
Providing, fixing, testing and commissioning of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required.
Providing, fixing, testing & commissioning of 150 mm dia deluge valve with wet pilot trim (Hydraulic Release), electric release trim test and alarm trim complete with all accessories viz fittings, pressure gauge, valves, actuator, manifold etc. alarm gong including up stream & down stream main header valve (Water Curtain for Facade Cooling).
Providing & fixing water curtain nozzle in Brass (ASTM B'16) suitable for 20 to 100 psi effective working pressure, with 1/2" BSPT inlet, K-33 and coverage of 2.5 meter either side at 1.4 Bar
Fabrication,supplying,installation,testing & commissioning of electrical control panel of cubicle construction, floor mounted type,fabricated out of 2 mm,thick CRCA sheet,compartalised with hinged lokable doors,dust and vermin proof,powder coated of approved shades after 7 tank treatment process,cable alley,inter connection,having switchgear and accessories mounting and internal wiring,earth terminals,numbering etc.Complete in all respect,suitable for operation on 415 V,3phase, 50 Hz AC supply with enclosure protection class IP42 as required.Fabricating & Supply, installing, testing and commissioning of compartmentalised common control panel for Electrical motor driven pumps and Diesel engine driven pumps.Star delta starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons.1 Set of RYB indicating lamps with individual HRC control fuses. As per SLD Approved.Main Fire Panel
Fabrication,supplying,installation,testing & commissioning of electrical control panel of cubicle construction, floor mounted type,fabricated out of 2 mm,thick CRCA sheet,compartalised with hinged lokable doors,dust and vermin proof,powder coated of approved shades after 7 tank treatment process,cable alley,inter connection,having switchgear and accessories mounting and internal wiring,earth terminals,numbering etc.Complete in all respect,suitable for operation on 415 V,3phase, 50 Hz AC supply with enclosure protection class IP42 as required.Fabricating & Supply, installing, testing and commissioning of compartmentalised common control panel for Electrical motor driven pumps and Diesel engine driven pumps.Star delta starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons.1 Set of RYB indicating lamps with individual HRC control fuses. As per SLD Approved.Boster Pump Panel
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Manual Call Point (MCP)- 9" x 9"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Exit -12"x 6"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Assembly point -38"x38"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Extinguisher-9" x 9"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Pump Room-38"x38"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Directional Arrow-12"x 6"
Supplying and erecting GI strip of required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed onwall painted with bituminous paint in an approved manner with jointsrequired. As per specification no EA-EP.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC1 6000MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC2 7250MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC3 6800MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC4 12000MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC5 7500MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC6 7800MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC7 7250MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC8 4000MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC9 7700MM X 2800MM
Supply installation testing and commissioning of Fire Curtains with Galvanised MS powder coated head top box Powder coated side guides (size 100mm x 50 mm) and bottom L bars with DC motors one per roller for curtain up operation with standard battery back-up fixed into 76 mm steel rollers with VWG 690 fabric with its control panel and all installation assemblies & accessories required to complete the installation. The operation shall be suitable for dedicated 230 volts UPS, 50 Hz AC supply. Complete system tested in accordance with UL(Tested,Certified & Labelled) (for 120 minutes integrity ) The emergency retract switch shall be provided on both sided of curtain. The Fire curtain retracts automatically when fire alarm is reset.FC10 6000MM X 2800MM
Sub Work No-5
SITC of Blower Unit Complete with Accessories and attachments. Complete with silencer, filters, dampers & installation accessories and air switch device. Automatic activation through centralized control system
SITC ofAir diverter:The Sir Diverter Controls the Airflow Direction (Pressure/ Vacuum) in the Pneumatic Tube Network as per need for the Individual Carrier Travel.
SITC of PTS Control Software :Powerful features to manage and miantain the Pneumatic Tube System with flexibility and efficiency.:
SITC of Supervision Software: Real time monitoring; Priority settings; Network viewing; System access and controls for each device on the network etc.
SITC of Switching Device Module for Frequency control. It provides interfacing between PC and our Pneumatic Tube System's devices. It gives communication throuout all the devices to operate from the PC.
SITC of PC Desktop with original Windows 10 for PTS control room, 64 bit, 8GB RAM ,500 GB HDD, CPU 13 inlet , Ethernet 10/100/1000, with colcored printer & Peripherals like mouse, keyboard, flat screen monitor with UPS for PC Complete.
SITC of Active Connect Box / LAN Converter is an intelligent component to create automated connections in a hospital pneumatic Tube System.
SITC of Propritory Software License Dongle for communication. It is license for our TranspoNet Software and other supporting softwares. Without this License the software can not run.
SITC of Power packs:The Power Pack is designed to supply all components in a hospital Pneumatic Tube System with a controlled voltage .And it is also used to boost up the power in long wire connections
SITC ofStation Devices: The receiving and sending stations for automatic receiving and sending of materials in the carriers. The Stations may be Top Loading, Bottom Loading accordin to the design of the system and as per requirements.
SITC ofLab Receiving Station:The Station Device for installation in laboratories with much reduced space capacity and always taking in consideration the ergonomically aspect.
SITC ofReceiving platform for Lab receiving station: receiving platform is used for soft receiving of carriers
SITC of Auto Receiving Station:The Auto Receiving Station allows continuous receiving of carriers enabling high throuhput especially in high traffic areas, such as pharmacy etc.
SITC ofRFID Readers for station (in built):RFID technology is for tracking and tracing the transport goods, eliminating the risk of loss with each station having RFID readers and each transport carrier/capsule with RFID transponders.
SITC ofForwarding Tubes including Installation Accessories including Clips, Thread rods: PVC-U Grey Forwarding tube with installation accessories including Clips, Thread rods etc.
SITC ofForwarding Bends including Installation Accessories including Clips, Thread rods:PVC-U Grey Forwarding bend with installation accessories including Clips, Thread rods etc.
SITC of Hangers, Basket and Upholstery: Hanger:Wall mounted carrier hanger used for holding Carrier Basket: Wall mounted carrier basket used for receinving carrier on arrival. Upholstery: used for carrier receiving basket used for reducing impact upon exit from station
SITC ofSleeves for joining tube lengths: PVC-U Sleeves 15 cm length OD:16.6 cm Approx & 16 cm ID Approx. for joining tube line.
SITC of Control Cable for communication & power to devices:The high speed RS485 protocol based system control composite cable for LVDC. low voltage supply and high speed communications to/with various system devices.
SITC of Capsules for transportation with RFID:Capsules with caps for secure use; fully integrated rubber seal; payload up to 3 kg; Impact resistant and crystal clear polycarbonate middle body; With Loading Dimensions of 330mmH x 120mm
SITC of Foam Inserts for sample holding:Foam Inserts made of soft sponge like material to hold vaccutainors.
SITC of Transparent Tube :PVC-U Forwarding Tube-Milky Transparent PVC U Milky Transparent Tube is used to connect zones in PTS blower Room. Pipe is of 3.2 mm wall thickness and 160mm outer dia. It is connected with the help of steel clamp.
SITC of Transparent Bend: PVC-U Forwarding Bend-Milky Transparent PVC U Milky Transparent Bend is used to connect zones in PTS blower Room. Bend is of 3.2 mm wall thickness and 160mm outer dia, 1.5 mtr in length with 800mmR. It is connected with the tube with the help of steel clamp.
SITC ofAutomatic Compact Linear Zone Transfer system (06 Zones + 6 Power lines): The Linear compact zone Transfer unit has been designed to connect various standard zones & Powerline for quick and high speed interchange of lines/zones, thereby reducing wait time.
SITC of Carrier Separator device (for zone) Carrier Seperator Device is used to trafer the carrier from one Zone to another zone line in a trasfer zone linear movement. It is a part of Autmatic Compact Linear Zone Transfer Unit
SITC ofPower line bottom (Bend with Motor Slide Gate): PowerLine are used for multi-carrier transports and transports over long distances for optimisation of transport frequency and efficiency
SITC ofBranching Device ( Diverters):The diverter units are used for branching/switching between lines and are manufactured using high quality steel with minimized electrostatic interference.
SITC ofOptical switch (Inbuilt):The Optical tube Switch has been designed to track and detect a carrier Transport contactless
CMC after Warrenty Period of 1 year.2.5% with an escalation of 10% per annum. (For 3 Years)
Sub Work No-6
SITC of Air Cooled Ducted Split Air conditioner Pure poleyster powder coated GI steel external housing with 380/420 V, 3 Phase at 50 Hz . Indoor consisting of Double inlet Double width centrifugal forward curve fan with Non woven polyster media enclosed by HDPE mesh & Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length(50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 3TR @ 1200 CFM.
SITC of Air Cooled Ducted Split Air conditioner Pure poleyster powder coated GI steel external housing with 380/420 V, 3 Phase at 50 Hz . Indoor consisting of Double inlet Double width centrifugal forward curve fan with Non woven polyster media enclosed by HDPE mesh & Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length(50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 5.5TR @ 2200 CFM.
SITC of Air Cooled Ducted Split Air conditioner Pure poleyster powder coated GI steel external housing with 380/420 V, 3 Phase at 50 Hz . Indoor consisting of Double inlet Double width centrifugal forward curve fan with Non woven polyster media enclosed by HDPE mesh & Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 8.5TR @ 3400 CFM.
SITC of Air Cooled Ducted Split Air conditioner Pure poleyster powder coated GI steel external housing with 380/420 V, 3 Phase at 50 Hz . Indoor consisting of Double inlet Double width centrifugal forward curve fan with Non woven polyster media enclosed by HDPE mesh & Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 11TR @ 4400 CFM.
SITC of Air Cooled Ducted Split Air conditioner Pure poleyster powder coated GI steel external housing with 380/420 V, 3 Phase at 50 Hz . Indoor consisting of Double inlet Double width centrifugal forward curve fan with Non woven polyster media enclosed by HDPE mesh & Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length(50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 17TR @ 6800 CFM.
SITC of Double skin air handling units of EUROVENT Certified. AHU's shall be of Double skinned panels of 40+/-2 mm thick. Double Skin Panels shall be made of 0.6mm Pre-coated GSS on outside and 0.6mm Galvanized sheet inside with CFC – FREE P.U. insulation of 40 (+/- 5%) kg/Cu M injected in between with an internal gasket between the skins to interrupt the thermal bridge of the panel.Single decker type suit at Site,Mixing Chamber,Fresh & Return Air Dampers,Prefilter section with 10 micron (EU 4) Pre filters,Filter section with 3 micron (EU 9) Fine Filters.Cooling coil section with 6 rows deep DX cooling coil for AHU,space required in AHU for UV lamps.Fan section with backward curved Plug fan with Aerofoil design blades with IE2 Motors with VFD's.AHU 1 / 4400 CFM / 125 MM S.P / 11.0 TR
SITC of Double skin air handling units of EUROVENT Certified. AHU's shall be of Double skinned panels of 40+/-2 mm thick. Double Skin Panels shall be made of 0.6mm Pre-coated GSS on outside and 0.6mm Galvanized sheet inside with CFC – FREE P.U. insulation of 40 (+/- 5%) kg/Cu M injected in between with an internal gasket between the skins to interrupt the thermal bridge of the panel.Single decker type suit at Site,Mixing Chamber,Fresh & Return Air Dampers,Prefilter section with 10 micron (EU 4) Pre filters,Filter section with 3 micron (EU 9) Fine Filters.Cooling coil section with 6 rows deep DX cooling coil for AHU,space required in AHU for UV lamps.Fan section with backward curved Plug fan with Aerofoil design blades with IE2 Motors with VFD's.AHU 2 / 3400 CFM / 125 MM S.P / 8.5 TR
SITC of Double skin air handling units of EUROVENT Certified. AHU's shall be of Double skinned panels of 40+/-2 mm thick. Double Skin Panels shall be made of 0.6mm Pre-coated GSS on outside and 0.6mm Galvanized sheet inside with CFC – FREE P.U. insulation of 40 (+/- 5%) kg/Cu M injected in between with an internal gasket between the skins to interrupt the thermal bridge of the panel.Single decker type suit at Site,Mixing Chamber,Fresh & Return Air Dampers,Prefilter section with 10 micron (EU 4) Pre filters,Filter section with 3 micron (EU 9) Fine Filters.Cooling coil section with 6 rows deep DX cooling coil for AHU,space required in AHU for UV lamps.Fan section with backward curved Plug fan with Aerofoil design blades with IE2 Motors with VFD's.AHU 3 / 1200 CFM / 125 MM S.P / 3 TR
SITC of Air Cooled Condensing Unit with 380/420 V, 3 Phase at 50 Hz . Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 11TR @ 4400 CFM.
SITC of Air Cooled Condensing Unit with 380/420 V, 3 Phase at 50 Hz . Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 8.5TR @ 3400 CFM.
SITC of Air Cooled Condensing Unit with 380/420 V, 3 Phase at 50 Hz . Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 3TR @ 1200 CFM.
SITC of Double skin air handling units of EUROVENT Certified. AHU's shall be of Double skinned panels of 40+/-2 mm thick. Double Skin Panels shall be made of 0.6mm Pre-coated GSS on outside and 0.6mm Galvanized sheet inside with CFC – FREE P.U. insulation of 40 (+/- 5%) kg/Cu M injected in between with an internal gasket between the skins to interrupt the thermal bridge of the panel.Single decker type suit at Site,Mixing Chamber,Fresh & Return Air Dampers,Prefilter section with 10 micron (EU 4) Pre filters,Filter section with 3 micron (EU 9) Fine Filters & Terminal HEPA.Cooling coil section with 8 rows deep DX cooling coil for AHU,space required in AHU for UV lamps.Fan section with backward curved Plug fan with Aerofoil design blades with IE2 Motors with VFD's.AHU 1 / 1450 CFM / 125 MM S.P / 11.0 TR
SITC of Air Cooled Condensing Unit with 380/420 V, 3 Phase at 50 Hz . Microprocessor based LCD display controller.With single or Multiple Air cooled ODU consisting of Reciprocating Compressor for small capacity up to 3TR and scroll compressor above 3 TR, compressor should be hermatically sealed type with propellor type fan for fins type air cooled condensor.The connection from Indoor to Outdoor with refrigerant piping and required control / communication cabeling for communication with the controller. Maximum Length of the Indoor to Outdoor for refrigerant piping should not exceed the standard length( 50 meters) given by the vendor. The unit should be mounted on the suitable MS Stand with Anti corrosive paint applied on it.The System to be charged with Green Refrigerant (R407). The cost should be inclusive of Vacuumizing, Nitrogen testing, Gas charging. 11TR.
SITC of Communication cabling between outdoor units / indoor units, in 25mm FRLS PVC Conduits, UV stabilised.
SITC of PVC Agri High Pressure pipe for Drain piping for the units With Insulation of Nitrile Rubber pipe section thickness of 6mm as per specification and suitable for following pipe size of DIA 50MM.
SITC of PVC Agri High Pressure pipe for Drain piping for the units With Insulation of Nitrile Rubber pipe section thickness of 6mm as per specification and suitable for following pipe size of DIA 32MM.
SITC of PVC Agri High Pressure pipe for Drain piping for the units With Insulation of Nitrile Rubber pipe section thickness of 6mm as per specification and suitable for following pipe size of DIA 40MM.
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.200 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.400 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.500 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.800 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.1000 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.1450 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.1600 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.5000 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.5500 CFM @ 50 mmWG .
SITC of Centrifugal Epoxy coated cabinet type fan with Class F insulation motor & mild steel mounting frame & vibration mounts, fire retardant flex connection with Isolator panel (IP-56) with Starters (DOL / Star Delta) as required & 10rmt of electrical cabling (armoured) between panel and Fan with terminations and required earthing on hot dipped galvanised perforated trays. DOL starter till 3.73 KW & Star delta for motors above 3.73 KW.6000 CFM @ 50 mmWG .
Supply, fabrication and erection of galvanised sheet metal ducting generally as specified and comple- tely factory fabricated withHot dip Galvanised companion flanges girth angles,Turning vanes.Hot dip Galvanised structural support systems & Closed cell neoprene gasket.0.63mm (24 SWG) galvanised sheet steel
Supply, fabrication and erection of galvanised sheet metal ducting generally as specified and comple- tely factory fabricated withHot dip Galvanised companion flanges girth angles,Turning vanes.Hot dip Galvanised structural support systems & Closed cell neoprene gasket.0.90mm (22 SWG) galvanised sheet steel
Supply, fabrication and erection of galvanised sheet metal ducting generally as specified and comple- tely factory fabricated withHot dip Galvanised companion flanges girth angles,Turning vanes.Hot dip Galvanised structural support systems & Closed cell neoprene gasket.1.00mm (20 SWG) galvanised sheet steel
Supply, fabrication and erection of galvanised sheet metal ducting generally as specified and comple- tely factory fabricated withHot dip Galvanised companion flanges girth angles,Turning vanes.Hot dip Galvanised structural support systems & Closed cell neoprene gasket.1.25mm (18 SWG) galvanised sheet steel
Supply, fabrication and erection of galvanised sheet metal ducting generally as specified and comple- tely factory fabricated withHot dip Galvanised companion flanges girth angles,Turning vanes.Hot dip Galvanised structural support systems & Closed cell neoprene gasket.1.6mm (16 SWG) galvanised sheet steel
Supply, installation, commissioning & testing of Smoke Spill (Dual Speed) Axial fans in acoordance with and meeting the intents of the speci-fications, drawings and data sheet:CFS complete with:Axial fan with variable speed without silencer.suitable "Class - H" Smoke venting Imported Motor rated 250 deg C for 2 Hours smoke evacuation. Direct driven Axial Fans.complete with Casing made of Z-22 Grade GSS, 220gsm zinc coating.Die cast aluminium impeller (hub and blades)Suitable rpm suitable for 415V / 3ph / 50Hz. A. C. Operation.Sound Level 80 db(A) / 70 db(A) @ 3mt Emergency / Pollution Mode Steel Structure for Installation along with Hilti Anchor Fastners.30,000 CFM (Fire Mode) /15000 CFM (Normal Mode) @40 mmwg
Supply, installation, commissioning & testing of Smoke Spill (Dual Speed) Axial fans in acoordance with and meeting the intents of the speci-fications, drawings and data sheet:CFS complete with:Axial fan with variable speed without silencer.suitable "Class - H" Smoke venting Imported Motor rated 250 deg C for 2 Hours smoke evacuation. Direct driven Axial Fans.complete with Casing made of Z-22 Grade GSS, 220gsm zinc coating.Die cast aluminium impeller (hub and blades)Suitable rpm suitable for 415V / 3ph / 50Hz. A. C. Operation.Sound Level 80 db(A) / 70 db(A) @ 3mt Emergency / Pollution Mode Steel Structure for Installation along with Hilti Anchor Fastners.15,000 CFM (Fire Mode) /7500 CFM (Normal Mode) @40 mmwg
Supply, installation, commissioning & testing of Axial fans in acoordance with and meeting the intents of the speci-fications, drawings and data sheet:CFS complete with:Axial fan with variable speed without silencer. driven Axial Fans.complete with Casing made of Z-22 Grade GSS, 220gsm zinc coating.Die cast aluminium impeller (hub and blades)Suitable rpm suitable for 415V / 3ph / 50Hz. A. C. Operation.Sound Level 80 db(A) / 70 db(A) @ 3mt Emergency / Pollution Mode Steel Structure for Installation along with Hilti Anchor Fastners. 13000 CFM (Normal Mode) @40 mmwg
SITC of Floor Mounted Energy Efficient DX Precision Air Cooled Units with R-410 A Refrigerant and Digital Scroll Compressor With Precise Temperature control & Ultrasonic Humidifier & Electronic Expansion valve along with smart control and Heat load Monitoring for 24 x 7 Working and Monitoring Delivering 106.5 KW net Gross cooling Capacity with Net sensible Cooling Capacity of 91.7 KW delivering air @ 27000 m3/hr.
SITC of Bearing free hardened steel shaft with rotation on single point steady and consistent RPM even after significant passage of time unlike ventilators using ball bearings having 30 Inches Body Dia with 39 No of Blades having exhaust capacity 184000 CFH . Vanes to be Anodized Alu 100/1000 0.4mm thickness (0.8 mm Outer side) with Shaft anfd tube Zinc Coated steel and galvanised support with suitable size rivets.
Supply, installation,testing and commissioning of Induction type jet fans with centrifugal impellars with motors, and all other accessories whether specifically mentioned or not. Note: Low Profile Type Jet Fans 275 mm Dia. Air Qty : 1.40 CMS (HIGH) Air Qty : 0.7 CMS (LOW) Mounting : Ceiling Suspended Installation along with Anchor Fashioners with all the required accessories & fittings.
Supply of BMS compatible PLC power and control panel with starter panel with all necessary control logics and software, for each basement.
SITC of CO SENSORS (CO sensors along with Installation)
SITC of Flexible power & control cabling with Condut for CO sensors with Saddles Earthing copper wire & Installation in pvc conduits. 4C x 1.5 Sq.mm For Co Sensors
SITC of Flexible power & control cabling with Condut for CO sensors with Saddles Earthing copper wire & Installation in pvc conduits.6C x 2.5 Sq.mm For Jet fans
SITC of Armoured FR (XLPE) power Cable for fans with Saddles Earthing copper wire & Installation. 4C x 6 Sq.mm
SITC of cable termination for Armoured FR (XLPE) power Cable for fans 4C x 6 Sq.mm
SITC of Turbo Fans Aluminum, Anti-corrosive construction, Stainless steel shaf, Double shielded Ball Bearing Well Balanced Silent operation. Tested for Gusty & Strong winds. No electrical power required. Reduces Heat & Removes foul odour, smoke etc. Fit & forget. Totally maintenance free No electricity, 1) Turbo Ventilators:- a) Vortex Blades :- Industrial grade Aluminum; 42 vens of 0.5 mm thick. b) Turbine Shaft :- S.S. 304. c) Vertical & Horizontal bracings :- S.S. 304. d) Ball Bearings :- Double Shielded Deep Groove ( maintenance free ) e) Bearing Housing :- S.S. 304. 2) Size :- 24” dia. ( i.e. 600 mm) 3) Output of Ventilators :- 2300 m3 / hr. ± 10 % Note :- The above mentioned output is guaranteed in ideal condition i.e. 1) wind velocity :- 6 Km / Hr. 2) Temperature difference :- 3º -4º C. ( in ideal condition)
Sub Work No-7
SITC of fully automatic control panel for MGPS Shaft - 1 with minimum flow rate of 2000LPM with following System should comply to ISO7396-1/HTM02-01/ NFPA.
With 2X40 cylinder manifold complete as per ISO 7396-1 / SPM0201 /NFPA. Manifold System has been designed to provide reliable uninterrupted supply of medical gases to pipeline network care units.
With tail pipes for above,as per ISO 7396-1 / SPM0201 /NFPA.: Used to connect Manifold to Cylinder
With NRV for above with fixing chain etc.as per ISO 7396-1 / SPM0201 /NFPA. NRV is non Return valve used in manifold.
SITC of fully automatic control panel for MGPS Shaft - 2 with minimum flow rate of 2000LPM with following, System should comply to ISO7396-1/HTM02-01/ NFPA.
With 2X30 cylinder manifold complete as per ISO 7396-1 / SPM0201 /NFPA.Manifold System has been designed to provide reliable uninterrupted supply of medical gases to pipeline network care units.
With tail pipes for above,as per ISO 7396-1 / SPM0201 /NFPA. Used to connect Manifold to Cylinder
With NRV for above with fixing chain etc.as per ISO 7396-1 / SPM0201 /NFPA. NRV is non Return valve used in manifold.
SITC of fully automatic control panel with minimum flow rate of 500 LPM with following, System should comply to ISO7396-1/HTM02-01/ NFPA.
With 2X6 cylinder manifold complete as per ISO 7396-1 / SPM0201 /NFPA.Manifold System has been designed to provide reliable uninterrupted supply of medical gases to pipeline network care units.
With tail pipes for above,as per ISO 7396-1 / SPM0201 /NFPA. Used to connect Manifold to Cylinder
With NRV for above with fixing chain etc.as per ISO 7396-1 / SPM0201 /NFPA. NRV is non Return valve used in manifold.
SITC of emergency regulator with minimum flow rate of 500LPM with 1x 3 cylinder manifold complete with tail pipes, NRV, fixing chain etc. Please check technical specifications for complete details. (Imp)as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Screw Compressor oil Lubricated (3 compressors running, 1 compressors standby) with the following
SITC of Receiving tank 3000 ltrs each (MS Construction, pre painted) as per ISO 7396-1 / SPM0201 /NFPA. It used to store Compressed air.The tank is equipped with a pressure gauge, safety relief valve and automatic drain valve with manual override.
SITC of Dryer (medical air as per european pharmacopoeia ):Moist air from the compressor is sent through the coalescing filter. Here water & oil coalesces and purges through the auto drain valve. The relatively clean air with water vapour passing through the aluminum drying tower filled with desiccant gets completely dried and then passes through a built in after filter . The desiccant fines from the towers are completely removed and clean dry air is let out through the outlet port for use.
SITC of Filteration Unit - 5 stage filteration (medical air as per european pharmacopoeia ):This filter removes aerosol and solid particles.The first stage is a prime efficiently coalesce with particle removal down 0.5 micron
SITC of Pressure reducing stationas per ISO 7396-1 / SPM0201 /NFPA.: Use to adjust the pressure of the pipeline to a certain pressure range.
SITC of Absorbtion dryer as per ISO 7396-1 / SPM0201 /NFPA. The exchange of water vapor from the moist compressed air into the hygroscopic material or desiccant causes the desiccant to gradually become saturated with adsorbed water.
SITC of Auto Drainas per ISO 7396-1 / SPM0201 /NFPA.:Due to cooling of compressed air, condensation of oil & water vapour takes place in Moisture Separators, Air Receivers, Filters, etc. Regular draining of these equipment is an essential maintenance function.Due to cooling of compressed air, condensation of oil & water vapour takes place in Moisture Separators, Air Receivers, Filters, etc. Regular draining of these equipment is an essential maintenance function. it ensure that all equipment of the Compressed Air System get drained regularly without manual dependence, except for periodic checks.
SITC of Rotary vane type vacuum pumps (2 running, 1 standby)as per ISO 7396-1 / SPM0201 /NFPA.: Vacuum pumps used to produce medical vacuum.
SITC of Receiving tank 3000 ltrs each (MS Construction, pre painted)as per ISO 7396-1 / SPM0201 /NFPA.The tank equipped with drain valve and vacuum gauge the inside of the tank coated for rust protection with a double component coating which provide a hard, durable lining.
SITC of Bacterial Filter as per ISO 7396-1 / SPM0201 /NFPA.:The bacteria filters is designed for critical applications involving the removal of liquid, solid and bacterial contamination from the suction side of vacuum pump systems, preventing damage to the pump and the potential biological infection of the surrounding environment
SITC of Auto Drain as per ISO 7396-1 / SPM0201 /NFPA.: it ensure that all equipment of the Medical Vacuum get drained regularly without manual dependence, except for periodic checks.
SITC of Area alarm + Area valves - Area alarm and shut-off unit for medical gases. Area alarm and area valves should be in a single unit.as per ISO 7396-1 / SPM0201 /NFPA.1 Gas (O2) and 1 Vac
SITC of Area alarm + Area valves - Area alarm and shut-off unit for medical gases. Area alarm and area valves should be in a single unit.as per ISO 7396-1 / SPM0201 /NFPA.2 Gases (O2, Air) and 1 Vac
SITC of Area alarm + Area valves - Area alarm and shut-off unit for medical gases. Area alarm and area valves should be in a single unit.as per ISO 7396-1 / SPM0201 /NFPA.3 Gases (O2, Air, N2O) and 1 Vac
SITC of Area alarm + Area valves - Area alarm and shut-off unit for medical gases. Area alarm and area valves should be in a single unit.as per ISO 7396-1 / SPM0201 /NFPA.4 Gases (O2, Air, Air 7, N2O) and 1 Vac
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 15x1mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 22x1mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 28x1,5mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 35x1,5mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 42x1,5mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 54x2mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 76x2mm
SITC of Isolation valves - Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position. Please check technical specifications for complete details. - (Imp/Ind) as per ISO 7396-1 / SPM0201 /NFPA. 108x2mm
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA. Terminal Unit O2
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA. Terminal Unit N2O
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.Terminal Unit Air
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA.Terminal Unit Air 8 bar
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA. Terminal Unit Vac
SITC of Terminal units Wall mounted - Meets the requirements,as per ISO 7396-1 / SPM0201 /NFPA. Probes
SITC of AGSS - AGSS-Terminal unit with probe for the purpose of conveying scavenged anesthetic gases to an appropriate place of discharge . Please check technical specifications for complete details. - Imported as per ISO 7396-1 / SPM0201 /NFPA.
SITC of Master plant alarm - To display all alarm messages from plant equipment at one place. - Imported, System should comply to ISO7396-1/HTM02-01/ NFPA.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 12mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 15mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 22mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 28mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 35mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 42mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 54mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 76mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
SITC of Copper Piping As per standards.EN13348@ LLYOD Certified. 108mm: Its used for the distribution of gasses such as oxygen, nitrous oxide, nitrogen, compressed air, vacuum air and for waste gas disposal.
Sub Work No-8
SITC of 2.5 LB capacity Novec 1230 /FK-5-1-12 (ref NFPA 2001 edition 2018) , DLP Assembly with automatic valve, push in connector for tube, 2.5 LB Novec 1230 /FK-5-1-12 (ref NFPA 2001 edition 2018) gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
SITC of 5 LB capacity Novec 1230 /FK-5-1-12 (ref NFPA 2001 edition 2018) , DLP Assembly with automatic valve, push in connector for tube, 5 LB Novec 1230 /FK-5-1-12 (ref NFPA 2001 edition 2018) gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
SITC of Linear pneumatic heat Detection Tube CE marked and detection system operating between 95oC-120oC with all necessary fittings & supports, fixing in the electrical panel compartment as required. The linear heat detection tube shall be of red colour with internal diameter 4mm (± 0.02) & external diameter 6mm (± 0.02).
SITC of Master Control Unit for controlling each system, complete with pressure switches, buzzers and electronic hooters, including all necessary accessories + electrical wiring to make each entire system functional.
Sub Work No-10
Providing and fixing on walls/ ceiling/ floor 65 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing on walls/ ceiling/ floor 80 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing on walls/ ceiling/ floor 100 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing on walls/ ceiling/ floor 150 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Supplying & erecting gun metal gate valve of size 32 mm dia complete as per specification no. FF-VL/GV
Supplying & erecting gun metal gate valve of size 40 mm dia complete as per specification no. FF-VL/GV
Supply, Installation, Testing & Commisioning of Pressure Reducing Valve with Bypass Arrangement complete for modulating pressure as per required for 25 Dia Pipe.
Supply, Installation, Testing & Commisioning of Pressure Reducing Valve with Bypass Arrangement complete for modulating pressure as per required for 32 Dia Pipe.
Supply, Installation, Testing & Commisioning of Pressure Reducing Valve with Bypass Arrangement complete for modulating pressure as per required for 40 Dia Pipe.
Supply, Installation, Testing & Commisioning of Pressure Reducing Valve with Bypass Arrangement complete for modulating pressure as per required for 50 Dia Pipe.
Providing and fixing white european type Indian Orisa Pan, of with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.
Providing and fixing of surgeons SCRUB sinks antimicrobial copper touch surfaces 18 GA. - EPA registered copper alloy with 16 GA. stainless steel body- wall hung - two station with foot pedal faucet and mising valve pre-piped - healthcare fixtures with all the required accessories.
Providing & Fixing in position Bed Pan Washer In DU Area of approved make comprising wall hung type fixture in pastel shade with CI brackets and chair & pan connector 32 mm dia Connection with flushing arrangment of approved make from Angular cock ,solid backelite cover & seat with CP hinges and rubber buffers . Fixing EWC to wall as directed.
75 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Sup[ply & installation of 600mm Wide heavy duty FRP covers with required accessories & fittings.
Construction of trench 450mm wide X 450 depth in masonry for Rain water line with 150mm thick wall resting on 1:4:8 concrete foundation with 6" PCC M15 benching with desired channel alignment. The inside face to be smooth plastered with 15mm thick plaster of cement mortar 1:2. with with required FRP cover.
ANCHOR OFFSHORE SERVICES LIMITED
ACME MEP Services (I) Pvt. Ltd.
ASMACS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .