Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹64.5 LAccepted-AOC 303 GHS 88 SECTOR 20 PANCHKULA 134113 HARYANA | PANCHKULA | HARYANA | 134113 | ₹64.5 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹86.0 LRejected-AOC SANTOKH VILA 81 1ST FLOOR PHASE XI MOHALI PUNJAB 160082 | 160082 | ₹86.0 L | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹99.5 LRejected-AOC | ₹99.5 L | L-3 | Rejected-AOC Other than L-1 |
| 4 | L-4₹1.0 CrRejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.0 Cr | L-4 | Rejected-AOC Other than L-1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical As per documents uploaded, firm has already secured two works in MES, hence as per Para 8 (b) (v) of NIT at Srl page No. 9 firm is not eligible for participation in further tender. |
| Sl No | Description | Qty | Unit | M/S BALWINDER SINGH L3 | M/s Anil Kumar L4 | chahalbuilders L2 | R D Bansal L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old exhaust fan of any size/ make from existing location, sealing cable end, and removing fan and deposited to MES store yard with and including arrangment of suitable transportation complete all as specified and as directed by Engineer-in-Charge.
Note:- (i) Exhaust fan to be deposited in good condition i.e. without any external damage.
(ii) Penalty @ Rs. 500 per fan shall be imposed if external damage found on exhaust fan. | 105 | EACH | 100 ₹10,500 | 150 ₹15,750 | 700 ₹73,500 | 100 ₹10,500 |
| 2.00 | Supply and fixing anti-bacterial type modular Switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed. | 225 | EACH | 205 ₹46,125 | 100 ₹22,500 | 155 ₹34,875 | 49 ₹11,025 |
| 3.00 | Supply and fixing anti-bacterial modular Socket outlet, 2 in 1, 2/3 pin, 6 Amps, two module, 230 volts complete all as specified and as directed. | 225 | EACH | 305 ₹68,625 | 250 ₹56,250 | 205 ₹46,125 | 120 ₹27,000 |
| 4.00 | Material & labour for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 1.50 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 1.50 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. | 5,625 | RUNNING METRE | 150 ₹8.4 L | 180 ₹10.1 L | 285 ₹16.0 L | 148 ₹8.3 L |
| 5.00 | M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 10.0 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. | 875 | RUNNING METRE | 305 ₹2.7 L | 1,300 ₹11.4 L | 799 ₹7.0 L | 580 ₹5.1 L |
| 5.01Note for Srl item No. 4.00 & 5.00 (a) Two runs of cable, one run of earth wire and one run of PVC non-metallic conduit shall be measured as one unit length. (b) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. (c) Earth wire shall run inside the conduit pipe complete all as specified. (d) Cutting chases and making good surfaces to match with existing to be measured paid and separately in relevant item of this schedule. | |||||||
| 6.00 | S&F powder coated sheet metal encloser for MCB distribution board, SPN, 8 Way, Double door, phosphatised with rated bus-bar 200 Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified and as directed by Engineer-in-Charge. | 35 | EACH | 1,510 ₹52,850 | 2,500 ₹87,500 | 1,650 ₹57,750 | 1,255 ₹43,925 |
| 7.00 | Supply & fixing MCB, 32 Amps, SPN, 'C' series, breaking capacity 10 kA, 240V complete all as specified and as directed by Engineer-in-Charge. | 70 | EACH | 490 ₹34,300 | 850 ₹59,500 | 450 ₹31,500 | 445 ₹31,150 |
| 8.00 | Supply & fixing MCB, 6 to 32 Amps, SP, 'B' series, breaking capacity 10 kA complete all as specified and as directed by Engineer-in-Charge. | 225 | EACH | 215 ₹48,375 | 200 ₹45,000 | 250 ₹56,250 | 120 ₹27,000 |
| 9.00 | Supply & fixing In line duct fan made of ABS plastic body connected to the duct and installing the fan unit, fan size 100 mm, rated voltage 230V, frequency 50 Hz, air flow 450 m3/h, 2450 RPM complete all as specified and as directed by Engineer-in-Charge. | 30 | EACH | 10,000 ₹3 L | 16,000 ₹4.8 L | 8,700 ₹2.6 L | 7,600 ₹2.3 L |
Updated dates
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
31 Jan 2026, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM(U)-119/2025-26 PROVN OF MULTI INLET EXHAUST SYSTEM IN COMMON TOILETS AND BATHROOMS AT COMMAND HOSPITAL (WESTERN COMMAND) CHANDIMANDIR UNDER PARA 35 OF DWP 2020
2025_MES_742436_1
CWE/CHM(U)-119/2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE (U) Chandimandir
Class B, Cate b(i)
9 documents required · 9 mandatory
₹1,000
GE (U) Chandimandir
₹2.0 L
24 Mar 2026
2 Dec 2025
2 Feb 2026
2 Dec 2025
31 Jan 2026
23 Dec 2025
2 Dec 2025 - 9 Dec 2025
Taking down old exhaust fan of any size/ make from existing location, sealing cable end, and removing fan and deposited to MES store yard with and including arrangment of suitable transportation complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Exhaust fan to be deposited in good condition i.e. without any external damage. (ii) Penalty @ Rs. 500 per fan shall be imposed if external damage found on exhaust fan.
Supply and fixing anti-bacterial type modular Switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed.
Supply and fixing anti-bacterial modular Socket outlet, 2 in 1, 2/3 pin, 6 Amps, two module, 230 volts complete all as specified and as directed.
Material & labour for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 1.50 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 1.50 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 10.0 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Note for Srl item No. 4.00 & 5.00 (a) Two runs of cable, one run of earth wire and one run of PVC non-metallic conduit shall be measured as one unit length. (b) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. (c) Earth wire shall run inside the conduit pipe complete all as specified. (d) Cutting chases and making good surfaces to match with existing to be measured paid and separately in relevant item of this schedule.
Supply & fixing MCB, 32 Amps, SPN, 'C' series, breaking capacity 10 kA, 240V complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing MCB, 6 to 32 Amps, SP, 'B' series, breaking capacity 10 kA complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing In line duct fan made of ABS plastic body connected to the duct and installing the fan unit, fan size 100 mm, rated voltage 230V, frequency 50 Hz, air flow 450 m3/h, 2450 RPM complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing In line duct fan made of ABS plastic body connected to the duct and installing the fan unit, fan size 150 mm, rated voltage 230V, frequency 50 Hz, air flow 500 m3/h, 2600 RPM complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Disc Diffuser with protection grill of size 150 mm complete with necessary fittings/ fixtures complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing of in line PVC duct pipe of size 100 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing of in line PVC duct pipe of size 150 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing of in line PVC duct pipe of size 200 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Cutting hole for air ducting of exhaust system in circle/ square shape as per site requirement, into or through bricks/ concrete walls built in cement mortar of superficial area suitable for 100 to 200 mm vent exhaust fan including making good of disturbed surface area in cement mortar 1:3 or cement concrete 1:2:4, type B-l and cover hole as required complete all as specified and as directed by Engineer-in-Charge.
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; for concealed conduit wiring etc., and making good, cutting not exceeding 10 cm girth etc., complete all as specified and as directed by Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tenderdocuments119.pdf
Tender Documents • 0.51 MB
Additional119.pdf
Additional Documents • 0.45 MB
BOQ_831387.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid