Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.5 LAccepted-AOC 0 GOPAL GANJ CHABUTRA KE SAMNE PRATAPGARH PRATAPGARH PRATAPGARH RAJASTHAN 312605 | PRATAPGARH | RAJASTHAN | 312605 | ₹8.5 L Quoted ₹7.2 L | L-1 | Accepted-AOC Accepted as the bidder attains L-1 status |
| 2 | L-2₹12.2 L+₹5.1 L (70.9%)Rejected-Finance | ₹12.2 L+₹5.1 L (70.9%) | L-2 | Rejected-Finance Rejected as the bidder attains L-2 status |
| 3 | L-3₹13.9 L+₹6.8 L (94.5%)Rejected-Finance 42 11 DIPKA PALI ROAD DIPKA DIPKA KORBA CHHATTISGARH 495452 | KORBA | CHHATTISGARH | 495452 | ₹13.9 L+₹6.8 L (94.5%) | L-3 | Rejected-Finance Rejected as the bidder attains L-3 status |
| Sl No | Description | Qty | Unit | V R ENTERPRISES L1 | SHASHI BHUSHAN SINGH L3 | SHRI LAXMI CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work in surface excavation not exceeding 10cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5m, as directed by Engineer In-charge. Area for excavation = 9220 Sqm. | 9,220 | Sqm | 9 ₹82,980 Lowest | 26 ₹2,39,720 | 12 ₹1,10,640 |
| 2.00 | Refilling of excavated earth wire cleaned stone size about 40mm (aggregate nominal size) in trenches, side of foundation etc in layers not exceeding upto 20 cm in depth, lead upto 50 meters (only clean stone to be refilled (recovered clean stone from excavated mixed soil)) 9220 sqm X 0.10 m = 922 Cum | 922 | Cum | 80 ₹73,760 Lowest | 175 ₹1,61,350 | 100 ₹92,200 |
| 3.00 | Providing and laying of fresh stone / pebbles - aggregate nominal size 40mm (9220sqm X 0.06m = 553.2 Cum) | 553.2 | Cum | 900 ₹4,97,880 Lowest | 1,480 ₹8,18,736 | 1,350 ₹7,46,820 |
| 4.00 | Revival of existing earthpits including excavation around the electrode and filling with charcoal/ coke and salt as required along with replacement of damaged G.I .nuts and through bolts with washer etc. as required for improvement of earthing system of 132 KV Substation | 60 | No. | 950 ₹57,000 Lowest | 2,650 ₹1,59,000 | 4,500 ₹2,70,000 |
| 5.00 | Anti weed treatment | 1 | Lumpsump | 5,000 ₹5,000 Lowest | 15,000 ₹15,000 | 5,000 ₹5,000 Lowest |
| 6.00Note: The estimated cost put to tender is excluding the PF and Pension Component. These statutory payment as applicable shall be reimbursed to the contractor on production of proof of payment limited to the maximum likely number of workmen to be deployed per day is 10 nos. | ||||||
| 7.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - |
Tender Value
₹17.3 L
EMD Value
₹21,700
Closing Date
30 May 2026, 5:00 pmClosed
Staff Officer (EnM)
Office of the General Manager, Dipka Area, Ph. No. 9424141353
Upgradation / revival of earth pits/ earthing system and stone gravel of active yard area of 132/33 KV Substation under Dipka Area.
2026_SECL_359783_1
SECL/GM/DA/SO(EnM)/ e-tender/26-27/19 dtd-16/05/26
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Dipka Area
Please refer to tender documents
5 documents required · 5 mandatory
₹21,700
3 Aug 2026
18 May 2026
1 Jun 2026
18 May 2026
30 May 2026
19 May 2026
18 May 2026 - 25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in surface excavation not exceeding 10cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5m, as directed by Engineer In-charge. Area for excavation = 9220 Sqm. | - | Sqm | - | - |
| 2 | Refilling of excavated earth wire cleaned stone size about 40mm (aggregate nominal size) in trenches, side of foundation etc in layers not exceeding upto 20 cm in depth, lead upto 50 meters (only clean stone to be refilled (recovered clean stone from excavated mixed soil)) 9220 sqm X 0.10 m = 922 Cum | - | Cum | - | - |
| 3 | Providing and laying of fresh stone / pebbles - aggregate nominal size 40mm (9220sqm X 0.06m = 553.2 Cum) | - | Cum | - | - |
| 4 | Revival of existing earthpits including excavation around the electrode and filling with charcoal/ coke and salt as required along with replacement of damaged G.I .nuts and through bolts with washer etc. as required for improvement of earthing system of 132 KV Substation | - | No. | - | - |
| 5 | Anti weed treatment | - | Lumpsump | - | - |
| 7 | Total impact of GST for the purpose of CTC | - | Nos | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tendernotice_2.pdf
PDF • 1.38 MB
Tendernotice_3.pdf
PDF • 0.15 MB
BOQ_372659.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .