Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC PLOT NO 407 HIMSHIKHA PINJORE PANCHKULA HARYANA 134102 | PANCHKULA | HARYANA | 134102 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹9.0 L+₹1.3 L (16.3%)Rejected-AOC H NO 816 NEAR GANDHI CHOWK KALKA 133302 HARYANA | KALKA | PANCHKULA | HARYANA | 133302 | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹10.7 L+₹3.0 L (39.3%)Rejected-AOC | L3 | Rejected-AOC Other than the lowest bidder |
Tender Value
₹10.1 L
EMD Value
₹20,100
Closing Date
5 Oct 2021, 6:00 pmClosed
GE JUTOGH
GE JUTOGH, JUTOGH CANTT SHIMLA (HP) - 171008
PROVN OF 04X PERS NIGHT PICKET ROOM AT MAIN GATE AND 02X LIGHTENING CONDUCTOR ONE FOR BLDG NO. P-69 ONE FOR FOL DUMP/ KSP AT MIL STN KALKA UNDER GE JUTOGH
2021_MES_473398_1
GE/JUT-42 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
KALKA
CLASS E CATEGORY a (i)
6 documents required · 6 mandatory
₹500
GE JUTOGH
₹20,100
Yes
28 Oct 2021
7 Sept 2021
7 Oct 2021
7 Sept 2021
5 Oct 2021
21 Sept 2021
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, comlete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, etc. and getting out complete all as specified and directed.
Excavation over area not not exc 1.5m deep and getting out in hard/dense soil, comlete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed
M&L M-25 Design mix (using 20mm graded stone aggregate) for foundation, includng footings, plinth beams, bases for columns, etc complete all as specified & directed.
M&L M-25 Design mix concrete (using 20mm graded stone aggregate) for column, pillars piers posts and struts etc complete all as specified & directed.
M&L RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressumners, lintels over 1.5m span complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L RCC M-25 (Design mix) (using 20 mm graded crushed stone aggregate) as in chajja/facia complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work rough finished surface complete all as specified and directed.
Form work to sides of pillars posts, struts, piers, columns and stanchion for fair finished surface complete all as specified & directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick (horizontal or sloping in rough finished surfaces of concrete complete all as specified and directed.
Use and waste of form work to side and soffit of beam, cantillevers, shelves troughs and similar items including edges for rough finished surface complete all as specified and directed.
Use and waste of form work to soffit of chajjas, shelves troughs and similar items including edges for rough finished surface complete all as specified and directed.
S&F MS TMT bar 10mm dia & over, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F MS TMT bar 6 to 8mm dia, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L MS TMT bars, 5mm dia and over upto and incl 10mm dia as in stirrups, spacers, binders etc cut to shape requred, incl cranking spirally for hooping for columns, hooking ends binding with and including mild steel wire not less than 0.9mm dia complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan any radius, built in cement mortar 1:4, in half brick thick wall complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surface of walls, mixed with water proofing compound as per manufacturer's instructions, finished even and fair complete all as specified and directed. Note: WPC shall be measured and paid separately as supply only.
M & L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or concrete surface of walls, finished even and smooth without using extra cement complete all as specified and directed.
M & L for 5mm thick rendering in CM 1:3 on ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M&L for broken stone hard core of gauge n. exc. 63mm deposited, spread and levelled in layer n. exc. 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2, using 40mm graded crushed stone aggreate as in plinth protection, the plinth protection shall be laid in alternate bays finishing the surface even & smooth without using extra cement complete all as specified & directed.
M&L100mm thick PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate as in sub base finishing concrete surfaces even and rough to receive top layer complete all as specified and directed.
M&L 20-22 mm thick machine cut kota stone slab, edge cut by machine as in flooring over and including 15mm thick screed bed in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing complete all as specified and directed.
M&L 18-20 mm thick machine cut kota stone slab, edge cut by machine as in skirting/dado fixed over and including 10mm thick rendering in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing complete all as specified and directed.
M&L for prepration of newely plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M & L for preperation of new plastered surface of wall and applying two coats of cement base paint complete all as specified and directed.
M& L for preparing newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
Returning filling in including spreading, levelling watering & well ramming in layers nexc. 25 Cm thick in each layers complete all as specified and directed.
Spreading, levelling in layers n.exc. 25 Cm thick in each layers, well ramming including watering as required of excavated material complete all as specified and directed.
Removing excavated material to a distence n exc 50m and depositing where directed at a level n exc. 1.50 M above the starting point for any type of soil complete all as specified and directed.
S&F pressed steel frames (made of 1.25 mm thick sheet) for doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed.
M&L PCC 1:3:6, type C-1, using 20mm graded crushed stone aggregate as in filling back of pressed steel frame complete all as specified and directed
S & F factory made 2nd class hardwood 35mm thick factory made plain framed panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm venerred particle board with commercial veneering on both faces. The size of rail and style as per IS- 1003 (part -I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F factory made 35 mm thick IInd class hardwood Glazed & skeleton shutters ,open rebated & prepare to receive gauze, divided into squares, with plain, chamfered and rounded,mitred and rebated sash bars ,any numbers size of members of shutter as specidied in SSR Part-I section 8 (clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F 125 mm long extruded aluminium alloy handle, fabricated type, anodised complete all as specified and directed.
S&F 200mm long aluminium anodised,barrel tower bolts of extruded section complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extrunded sections and fixing bolt and sliding bolt of extrunded sections or cast aluminium alloy complete all as specified and directed.
S & F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S& F 4mm thick sheet glass plain ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia or wire and average width or apeture 1.40mm and fixed with stainless steel wire staple in complete all as specified and directed.
M & L for preparation of new or previosuly untreated wooden surfaces of any description not otherwise described over 10cm width or grith and applying two coats of Synthetic enamel paint to wooden surface over and incl one coat of pink primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any descirption not otherwise described over 10cm width or grith and applying two coats of synthetic enamelled paint over and incl one coat of red oxide primer complete all as specified and directed.
S&F mild steel Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Gde E-165 complete all as specified and directed.
M& L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square meter of surfce area for anti termite treatment complete all as directed.
M&Lfor Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface ( Area of the sub structure in contact with backfill to be measured).
M&L treating the top surface of filled earth at the rate of 5 liters of emulsion per square meter of surface complete all as directed.
M&L for treating the soil under plinth protection at the rate 5 litres of emulsion per square metre of surface area complete all as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on concrete surface of roof finished even and smooth without using extra cement mixed with water proofing compound of approved make as per manufacturers instructions on existing surfaces complete all as specified and directed. Note: WPC shall be measured and paid separately as supply only.
Supply only water proofing compound as approved complete all as specified and directed.
M&L for cleaning of old roof slab surfaces including sweeping clean &washing down with water to remove dust & providing water proofing treatment with polymeric standard water proofing membrane complete all as specified and directed as under : (a) M&L preparation of plaster surfaces /RCC roof surfaces and applying one coat of oil bound bituminous primer @0.30 Ltr/sqm (b) M&L applying bitumen @1.20kg/sqm of grade 85/25 (c) Supplying and laying modified polymeric water proofing membrane super thermo lay 3mm thick of weight not less than 3.00kg /sqm reinforced with polyester non woven fabric weight not less than 150gm/sqm center core including coping on the surfaces with torch application of membrane with 10cm over laps as required all complete all as specified and directed (d) Applying one coat of bitumen 85/25 @1.2 kg/sqm complete all as directed. (e) Applying aluminium paint @ 0.20 kg/sqm complete all as specified and directed.
M&L for mooram/ red bajri filling in floor or paving laid in layers not exc 15cm thick including spreading, levelling and watering complete all as specified and directed.
M&L75mm thick PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate as in sub base finishing concrete surfaces even and rough to receive top layer complete all as specified and directed.
M&L for Pre-cast cement concrete solid blocks, with precast cement concrete 1:3:6 type C-1, using 20 mm graded crushed stone aggregate as in kerb stone, set in cement mortar 1:4, edging laid on end vertically including necessary earth work, tamping earth around solid block and removing of surplus soil to a distance n.exc 50m complete all as specified & directed.
M & L for machine pressed precast interlocking paver block of any size any shape conforming to IS -15658 - 2006 of 80mm thick, M-40 Grade, with grey cement and pigment set over sand cushining as per site requirement complete all as specified and directed.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm with concealed Conduit with fixing accessories, to be fixed , for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, colour code of wires as per specification , complete all as specified and directed.
One light /fan/bell point controlled by one, switch complete all as specified and directed.
One 5 pin 5/6 Amp socket on the same board complete all as specified and directed.
One 5 pin 5/6 Amp socket on independent board complete all as specified and directed.
One 3 pin 15 Amp socket independent but with 2.5 sq mm PVC insulated (FRLS) unsheathed copper stranded conductor and earth wire with 2.5 Sqmm
S & F switch piano type 240 V, 6 Amp , Sp one way flush type complete all as specified and directed.
S&F socket 5 pin, 6 Amp, flush type piano (multi purpose) complete all as specified and directed.
S&F Socket 15 Amps flush type 230 Volts , AC complete all as specified and directed.
S&F switch 15 Amps flush type 230 Volts , AC complete all as specified and directed.
M&L Fan regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed.
S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S&F for lamp holder pvc body with back plate complete including with 9/10 Watt LED lamp complete all as specified and directed.
S&F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S&F MCB SPN 32 to 40 Amps 250V incl all termnials, fitting etc. complete all as specified and directed.
S&F MCB SP 6-32 Amp ,240 Volt incl all termnials, fitting etc. complete all as specified and directed.
S&F energy efficient T-8 LED batten integrated type single tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten with extruded aluminium/PC Body and PC diffuser including all accessories pre wire and connecting up with copper three core flexible wire complete all as specified and directed. Make: Cormpton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Philips/Wipro/Havells.
S&F ceiling fan 1200mm sweep, 240 volt complete all as specified and directed.
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core , complete all as specifed and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50 mm dia confirming to IS , approved colour complete with fittings for cable protection complete all as specifed and directed.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts & screws as specified type 410 SP-64 (12 metres long) complete incl painting with two coat of silver paint over red oxide primer etc with following items complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 2.0 Mtr deep and n.exc 1.5 mtr wide for erection of Poleand getting out including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
Removing of excavated surplus soil obtained from excavation to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr of the starting point complete all as specified and as directed .
M&L for PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified.
M&L for PCC 1:3:6, type C-2, using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4, type B-2, using 20 mm graded crushed stone aggregate as in coping and mass concrete, complete all as specified and directed.
S&F Air termination, single pointed, copper rod 12mm dia and 300mm long with necessary fixing arrangement on pole complete all as specified and directed.
S&F PVC Insulated single core Flexible copper conductor cable of 70 sqmm cross section area 1100V conforming to IS:694 complete all as specified and directed.
M&L for earthing complete with copper earth plate 600x600x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to copper strip 20x3 mm as Earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
m/s jupiter builders
M/s Bhisham Raj and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .