Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.2 L+₹2.5 L (7.14%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹39.9 L+₹4.2 L (11.8%)Rejected-Finance 6 SAI KRUPA SONAWANE PARK BEHIND TILAK NAGAR BUS STOP OZAR MIG NASHIK 422206 | NASHIK | NASHIK | MAHARASHTRA | 422206 | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
PROVISION OF WORKS SERVICE
2021_MES_496781_1
8838/E8
Open Tender
Civil Works
Item Rate
240 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹70,000
Yes
12 Feb 2022
23 Dec 2021
26 Jan 2022
24 Dec 2021
24 Jan 2022
12 Jan 2022
60 days
Amount
Taking down door shutter with chowakat and remove exc 1.5 sqm, but n. 4sqm
Taking down door/window/ventilator with frame but and shutters (without taking off shutters from the frames) and remove from site n.exc 1.5 sqm each complete all as specified.
Demolition of brickwork or stone boulder masonary built in cement mortor including all quions , arches pillars etc but excludingashlar facing derssed stone work and precast conrete articles
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces and finished surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for (10+5) 15 mm thick rendering in cement mortar 1:4 finished even and smooth on other than fair faces of brick work etc and using water proofing compound even and smooth without using extra cement. (WPC will be measured and paid separetely) complete all as specified and as directed.
M&L for Complete removal of existing treatment from the wall surfaces.
M&L for preparation of old plasterd surfaces of wall any description over 10CM girth or width not oterwise described and applying two coats of plastic emulsion paint over a coat of primer including 02 coats of wall care white putty not less than 1.50mm thick complete all as specified and as directed.
M&L for Cutting in to old masonarry to form toothing for and bonding in new brick or stone work in cement mortor including making good etc complete.
M&L for Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises in cement mortar.
M&L for Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete in CM 1:4 etc,complete all as specified and as directed.
M&L for Making good under cills (or over arches, lintels and bressummers) including all pinning as necessary in CM 1:4.complete all as specified and as directed
M&L for RCC 1:2:4 Type B-1, (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as directed & as specified.
M & L for Formwork to sides & soffits of floor or roof beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc.complete all as specified
M & L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified
All as per item no 15, but 6mm to 8mm dia, as in stirrups
Taking down cement plaster any description, on brick or stone walls or ceiling , etc. including raking out joints, hacking for key, scrubbing down with water, etc
M&L for Rendering 5mm thick on ceiling in cement mortar 1:6 on fair faces of brick/concrete surfaces and finished surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of plastered or unplastered new surface on ceiling and applying three coats of white wash over chalk whitening primer all as specified and directed.
M&L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level).
M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40 mm graded stone aggregate).
M&L for 40 mm thick Cement concrete type B- 0, 1:2:4 (12.5 mm graded stone aggregate).
M&L for 38mm width,glass dividing strips, 3mm thick, inserted in position, conform to design all as specified and as directed
Material and Labour for preparing concrete floor surface and providing 5mm thick antistatic EPU flooring including prime coat, 3mm thick epoxy mortar screed bed, copper tapes, conductive coat, 2mm thick self levelling top coat and including removing old sealant cleaning and filling existing joints all as specified and application of Epoxy polyurethane paint of width or girth 10 to 15 cm marking all as per manufacturerinstructon complete all as specified and as directed. Make: FOSROC/CIPY / PIDILITE
Material and Labour for preparing of concrete floor surface and providing 2-3 mm thick ESD flooring of size 600 x600 mm including necessary adeshive/chemical coat, mortar screed bed, copper tapes, conductive coat, 2mm thick self levelling top coat and including removing sealant cleaning and filling existing joints as per manufaucturer instruction complete all as per directed.
M&L for GI lay in panel metal ceiling consistng of 600 x 600 mm lay in tiles of pre coated galvanised steel in 0.5 mm thick in global white colour or any other colour as approved to be laid on grid systems with colour and white/blackreveal white having rotary stitching on the main runner, 1200 mm & 600 mm cross tees complete all as manufacturer instrcuction and all as directed. Note: Tiles with fire performance of class A2-s1.d0 as per EN 13501 standard in module size of 600 x600 mm, suitable for green building application, with recycled content of 25% main runners & cross tees to have mitred ends and birds mouth, notches to provide mitred cruciform junctions. The Tee sections shall be of galvanizing at 90 gms per sqm with pullout strength of 100 kgs all as specified and directed. Make: Armstrong or equivalent as approved
S&F 12mm Toughned glass door double leaf making holes to glass for fixing door hanle / locking arrangement, fixed pavit shower seal silicon in glass door eadges poloshing /moulding including cutting to shape drilling holes, etc, hatching design / pttern as approved by User complete all as directed . Make: Saint Gobain/Modi guard or equilent . The following fttings rates shall be deemed in this items. Notes: (i) S& F 02 nos of each leaf style door pull 600mm long handle of grade 304 SS "H" type 32mm dia heavy wall tubing for 12 to 18mm thick toughened galss complete all as specified and as directed by Engr-in-Charge. (ii) S&F SS lockfor toughned glass for single/double leaf shutter with tripple key etc complete complete all as directed Make: Godrej or equivelent
S&F for Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty ISI Mark complete all as specified and as directed. Make : Dorma/Shivalik/Royal
S&F for 12mm toughned glass partion with hatching design / pttern as approved by user and fitted Stainless steel at top & bottom rail/channel to floor and ceiling with necessary fitting arrangement and gaps are field with silicon sealant including degine/pattern as approved complete all as specified and directed by Engr-in-Charge Make : Saint Gobain or equivalent Note (i) :- :- The rate quoted shall be inclusive of hatching design / pattern as approved (ii) Contactor to note all minor detail deemed to be included and discussed with Engr-in-Charge before quoting the rate.
S&F Aluminium composit panel (ACP) 4-6 mm thick for outdoor fixed to wall/cladding, coloum projection, chajja, roof projection facia, in elevation etc or any other postion & shape in any ornamental /Geometric shape as approved colour and manufacturer brand including all fitting & fixtures materials such as MS hollow rectangular/tublar sction, 2-3 mm thick and 50mm x50mm section fixing to 600x600mm of grid for base framing including fixing of MS Frame work/ all necessary fitting clamps, clits, riviting, bolting, welding, washers, wheather sealents, gasket forms fastening, strips etc as per site/technical requirements to complete all as specified and as per manufacturer instructions. Make : Greenlam/Arrowbond/Viva Note : (i) Necessary Scaffolding work up to 5.0 meter height is be included in Quated rates.
S/F second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,etc complete
S/F 35 mm thick Plain, framed, panelled shutters (any number of panels), with panels of veneered particle board medium density of thickness 35mm in second class hard wood complete
S/F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified
S/F 300 mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.
S/F M S Butt hinges, cold rolled, medium weight and fixed, of size 125mm complete
S/F 150 mm aluminium handles, cast type, anodised etc complete
S/F Mild steel works as in hold fasts and similar small articles etc complete
Plain cement concrete, type C1, 1:3:6,using 20mm graded granite stone aggregate in hold fast the like including weathering, slightly rounded or chamfered angles and throating, etc complete
M&L Preparation wooden surface of new or previously untreated surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a cotat of pink primer.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings including provision of glass, wiremesh etc complete all as directed. Note : The glass, wire mesh shall be measured and paid separately vide releavent item) .
Supply & fixing tinted sheet glass of 5 mm thick to door/windows/partions including necessary EDPM beading complete all as specified
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L Preparation wooden surface of new or previously untreated surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a cotat of zinc chrome primer complete all as specified.
M&L Screed bed or bedding layer of mortar 15mm thick of CM 1:6 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M&L for 20mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding/nosing/rounding of edges etc complete all as specified and as directed.
Demolation of cement Concrete of any description and in any position not otherwise specifically provided for including PCC for existing roof as a padding concrete, PCC tiles with screed bed and removing the demolised materials from out side MD Land complete all as specified.
M&L for brushing with neat cement slurry @ 3 Kg per sqm all as directed
M&L Plain cement concrete 1:2:4, type B0 (using 12.5mm graded aggregate) using WPC @2% by weight of cement as per manufacturer instruction as in padding/covering at junctions on roof complete all as specified and as directed.( Note - WPC shall be included in this item)
M&L for 5mm thick in Screed bed or bedding layer of CM 1:3 mixed with water proofing compound @ 2% by weight of cement to have a smooth surface finish for laying of water profing membrane. ( Note -Cost of WPC Shall be included in this item)
M&L for applying evenly a tack coat of hot blown bitumen 85/25 grade @1.2kg/sqm over a coat of primer @ 0.40 kg/ sqm including cleaning surfaces of plstered surface of roof througly all as specified
M&L for polymeric water proofing membrane, 3 mm thick reinforce with polyster non wooven fabric (wt 3.5 Kg per square metre membrane) laid over roof surface with 100 mm over lap and including vertical surface upto required height and tucking into grooves and sealing complete with thermofusion laid by torch application method including Applying two coat of bituminous aluminium paint @ 100 gms per square metre over membrane all as directed. Make: M/S STP Ltd, M/S TEXSA Ltd, M/S TIKI ASPHALT HYDROSTOP
M&L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level).
M & L for cement concrete type C2 (1:3:6) (40 mm graded broken stone aggregate) 75 mm thick as in plinth protection including necessary form work complete all as specified.
M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound of Grade A
Excavation over areas, n.exc 1.5 m deep and getting out in Soft / loose soil .
Excavation in post holes(or simila holes) each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm in soft loose soil.
M&L for Plain cement concrete1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete
M&L for RCC 1:2:4 type B1 (using 20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams bases for columns, etc.; basement slabs under-reamed piles and mass concrete including form work copmlete all as specified.
M&L for moorum/red bajri filling in floors or pavings laid in layers n. exc. 15cm thick, spread, leveled and rammed including watering.
M&L for Hardcore of guage n. exc 63mm, broken stone aggregate deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface
M&L for 75mm thick Cement concrete 1:4:8 type D-2, (using 40mm grade aggregate) as in sub base floor
M & L for polythene film, black, 50micron laid in floors.
M & L for Cement Concrete 1:1.5:3 type A1 (using 20 mm graded stone aggregate), as in top layer of hard standing/ floors finish etc complete all as specified and as directed.
M&L for rolled sections as in main trusses or cross beams, rafters, purlins of specifed angular/tubular section, beams or channel sections with flange plates caps, bases, cleats and other connections Fe-410 W (Gde E-250) quality B.
S&F for MS Plates (plain or chequered) channels, square cut or notched (ordinary & counter sunk) forming holes, without any attachment Fe-410-W (Gde E-250) quality'B' all as specified and derected
S&F Mild steel screw 10mm dia Nuts & bolts with welded to required shape (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 50cm but n exc 10cm long, complete as specified and as directed.
Supply and fix Hand rails, half round or other steel section drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof fixing screws for fitting the strip for roof of grade fe-410 W quality B grade E-250
M & L for preparation for new or previously umtreated steel surfaces of any description, over 10cm in width or girth,not otherwise described for two coats of synthetic enamelled paint over a coat of red oxide or zinc chrome primer on steel surfaces etc, complete all as specified and as directed."
Preparation of new steel surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc choromate primer
M&L for Applying 2 coats of Bitumenous paint over surfaces of any description steel, iron, brick, concrete, stone, wood etc. exceeding 10cm in width or girth.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified.
M&L for Forming Contraction (Dummy) joints 65mm deep and 10mm wide, filled with sealing compound grade 'A'
M&L for Removing of excavated material exc 250m but n exc 500m and deposited where directed at a level n exc. 1.5 m above the starting point
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 50 mm
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in in hard dense soil, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 mm levers of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Supply, installing, commissioning and testing static Silent Diesel Engine driven generating set capable of delivering 30 KVA, 415 volts (AC 3 Phase, 4 wire system of supply), 50 HZ at power factor 0.8 minimum, as per IS: 10001/10002 and alternator as per IS:13364 complete with relay panel for automatic starting on mains failure, control panel (AMF) having meters, sound proof canopy and including PCC foundation as per manufacturer's recommendation. The DG set shall consist of a diesel engine coupled directly to a matching alternator and mounted on Anti vibration pads of approved make on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardized by manufacturer, complete all as specified and directed and shall comprise of the following:-
(a) Engine (prime mover) : Directly coupled Diesel engine water cooled suitably de-rated of matching BHP for driving 30 KVA capacity alternator electric start, four stroke confirming to latest IS 10001/10002 Part-II 19801 for continuous running and capable for taking 10% over load for 1 hour complete with following accessories :- (i) Fly wheel to suit flexible coupling (ii) Flexible coupling with guards (iii) Air cleaner with filters (iv) Lubricating oil filter (v) Anti-vibration pad as recommended by manufacturer’s (vi) PT pump with electronic governor of suitable capacity (vii) Self-starter 12 volts DC
(viii) Necessary arrangement for charging battery (ix) Lead acid storage or dry type battery as recommended by manufacturer along with flexible copper battery lead and connector (x) Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm and 150 mm height - 01 number (xi) standard safety device (xii) daily service fuel tank for full running capacity of DG set for min 08 hours enclosed within the canopy all as per CPC B with lever indicator inlet, fuel outlet drain pug, air vent and locking arrangement’s etc. (xiii) Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and stage for operator
(xiv) Engine display should have following:- (a) KW, KVA, KWH, KVAR, Power Factor, Phase to Phase & Phase to Neutral Voltage, Ampere etc., (aa) Lubrication oil temperature (ab) Lubrication oil pressure (ac) water temperature (ad) Battery voltage (af) Indicator lamp etc (ag) Safety measure :- (i) Low lubricant oil pressure trip (ii) High coolant temperature trip (iii) Engine over speed trip (iv) Battery charging alternator (v) Emergency stop pressed.
(b) Alternator : 30 KVA at 0.8 power factor, self-regulated 3 phase with neutral 415 Volts 50 Hz 1500 RPM as per IS 2613 / IS : 4722 complete with automatic voltage regulator and foot mounted regulator and foot mounted including making cable connection. The salient feature of alternator are as under:- (i) Voltage regulation under static condition + 1.5% (ii) Class 'H' insulation (iii) Permanently lubricating bearing (iv) Capable to make 10% over load for one hour for every 12 hours (c) AMF Panel in built suitable for 30 KVA DG set (d) Acoustic Enclosure : Floor mounted acoustic enclosure suitable for 30 KVA DG set as per CPCB norms of the make as that of DG set be provided
Note1: DG set shall be composite type with AMF panel prime mover and alternator and allied accessories in one enclosure, PCC/RCC foundation as per OEM Make: Kirloskar /Cummins/Crompton Greaves Note2:Fuel for testing is deemed to be included in quoted rate
Removal of old junction boxes and making good of disturbed surface complete as original one complete all as specified & as directed by the Engineer-in-charge.
Supply and fix in repair double door sheet metal enclosure for DBs when MCBs to be used single pole and neutral 8 WAY SPN DB with 200 amps rated bus bar complete all as specified & as directed by Engineer in charge.
Supply and fix in repair double door sheet metal enclosure for DBs when MCBs to be used single pole and neutral 4 WAY TPN DB complete all as specified & as directed by Engineer in charge.
Supply and fix in repair double door sheet metal enclosure for DBs when MCBs to be used single pole and neutral 4 WAY SPN DB with 200 amps rated bus bar complete all as specified & as directed by Engineer in charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. (i) TP 25 To 63 AMP
Supply and fixing amp rating SPN 32 AMP, 240V, 10KA, 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & as directed by Engineer in charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning..
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level,connected to galvanised iron wire 4 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 15 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol,Bentonite and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cotten soil brought at site.
Point wiring with 1.5 Sqmm (nominal area) PVC( Antitermite ecofriendly FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item No 88 here-in-before but for one 3 pin 5 Amps socket outlet on independent board.
All as per item No 88 here-in-before but for one 3 pin 5 Amps socket outlet on the sameboard with other switch with 1.5 sq mm size.
Point wiring with 2.5 Sqmm (nominal area) PVC( Antitermite ecofriendly FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed PVC conduit with all fittings such as bends, tee,junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including sunken box with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators, etc complete all as specified and as directed by Engr -in -Charge.
M&L wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLSH) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x4.0 Sqmm+1x4.0 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and as directed by Engineer-In-Charge (Note: 2 run of 4.0 sq mm & 1 run of 4 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
Supply, Installation, testing and commissioning of CPRI approved, factory made, outdoor Floor Mounted cubical, self supported, front & rear openable, double door ,hinged type with locking arrangement & sloping top canopy ,suitable ventilation on one side, with wire mesh,IP52 protection with Dust & Vermin proof etc. fabricated out of 3.15 mm CRCA sheet duly powder coated with , mounted/fixed on MS Angle iron stand /frame 40cm height from FFL. Fabricated out of 50*50*6 mm thick MS Angle duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:3:6 Type C1 using foundation ,Control wiring copper stranded PVC insulated FRLS Cable connected from main bus bar ,earth bus strip of 32*6 mm size for entire length of panel ,suitable size of MS Gland with gland plate, and aluminum lugs/thimbles for all incoming and outgoing cables ,etc, complete all as directed by GE including and accommodating the following, Main LT panel working on 440V 3-phase, 50 Hz, AC supply with copper bus bars , fully compartmentalized, & suitable for outdoor weather conditions and including the following accessories and as shown in single line diagrams GE-1970 Copper bus bar of 300 Amp for 3 Phase & 300 Amp for N, a)Out going MCCB 100 Amp TP 415 Volts 36KA - 01 Nos Legrand Cat Pt -420095 b)In comming MCCB 63 Amp TPN 415 Volts 25KA - 01 Nos Legrand Cat Pt -420043 c)Indicating lamps LED type for RYB - 03 Nos d)Multi function meter for measuring Voltage, Amp,Hz etc.- 01 No
Supply and install hi wall split units indoor/outdoor of 2 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity as shown complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing copper tubing with insulation for extension of connection from outdoor to indoor complete all as specified and as directed by the Engineer-in-charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed by the Engineer-in-charge.
Supply & fixing of voltage stabilizer 4 KVA of 170-280V Complete all as specified and as directed by the Engineer-in-charge.
Core cutting for making holes for inter connection of outdoor to indoor unit from stone/ brick masonry including plastering,making good of disturbed portion and painting to match with existing surface complete all as specified and as directed by the Engineer-in-charge.
M&L wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x4.0 Sqmm+1x4.0 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and as directed by Engineer-In-Charge (Note: 2 run of 4.0 sq mm & 1 run of 4 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
Supply & Laying heavy grade class 'C' MS tubing 25 mm bore in trenches/floor/fixed to wall / ceiling with suitable clamps (pipe to be clamp to bracket fabricated out of suitable rolled steel ISA and fixing the same by grouting in brick wall,closing hole with PCC 1:2:4 ,plastering and painting the surface to match with existing touch up) , complete with class 'C' fittings such as bends,Elbow,Tees,Reducer Tee, Short pieces,Caps plug union & flanges,nuts & bolts ,& provision of adaptor for outlet connection etc. duly welded to each other for carrying compressed air supply at pressure 8 Kg per sq cm for outlet as per requirement , including painting to pipe line with two coats of synthetic enamel paint over one coat of Red Oxide primer as per colour code as specified in relevent IS ,complete all as specified and as directed by Engineer In Charge. Make:Apollo/Jindal/Tata
Supply & fix full way ball valve for gas / air body made out of hot pressed brass and Nickle or chrome plated , with steel ball and teflon seal with steel handle with PVC grip manufactured accordence with EN-2900 make CIM or its equivalent suitable for 8 Kg per sqcm working pressure of size 25 mm bore, complete all as specified & as directed by Engineer-In-Charge.
Supply and fix High efficency oil moisture separator for eliminating moisture from compressed air suitable for 25 mm Nominal bore compressed air line with matching flanges all as specified and directed by Engineer-In charge.
Supply and fix pressure gauge for compressed air suitable for 25 mm Nominal bore compressed air line with matching flanges all as specified and directed by Engineer-In charge.
S/F Quick release valve suitable for compressed pipe line having male and female connectors of 25 mm dia complete all as specified and as directed by the engineer in charge.
Supply and fix in repair LED tube light fitting 1X20W, high quality material & design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable & robust housing structure, maximize the endurance over the lifetime slim integrated design easy to install efficasy : 125 lum/ watt 220V AC of make : Crompton Cat Part no: CCS-100-20-65-HL2-DP-NWH or equivalent make of Havells / philips or equivalent, complete all as specified and as directed by the engineer in charge.
Supply & install dehumidifier made of MS body powder coated 600 watt, Noise level approx 49 db rotary compressor & refrigerant gas R-410a with extraction capacity of 35 ltr/day & air flow 220 Cum/hr , bucket size 6.5 ltr with the provision of humidity display, should have a provision for electronic setting RH value. Set of 2 one working & One standby including drain pipe and connecting arrangements etc., complete all as specified and as directed by Engineer-in-Charge. Make: Origin cat pat: ND 390-I or equivalent make as approved by GE.
Supply & Fix Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm two to three terminals.complete all as specified and directed by Engineer-in-Charge
Supply & fix Modular switch one way 6 Amp,1 Module , complete all as specified and directed by Engineer-in-Charge
Supplying and fixing Modular socket, 6 amps-2/3 pin combined, 2 Module, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing Modular switch , one way, 16 amps, one Module complete all as specified and directed by Engineer-in-Charge
Supplying and fixing Modular socket 16 amps-6 pin multipin, 2 Module complete all as specified and directed by Engineer-in-Charge
M/S PRAMOD SURESHCHANDRA AHER
M/s M R MAHANA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .