| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹27.6 L+₹79,686.05 (2.98%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹27.8 L+₹1.1 L (3.93%)Rejected-Finance 4 9 SWARG ASHRAM NANAK RAM COLONY PARAMANAND CHOWK DELHI 110 009 | NEW DELHI | NEW DELHI | DELHI | 110009 | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹28.7 L+₹1.9 L (7.15%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹28.8 L+₹2.1 L (7.72%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹34.1 L
EMD Value
₹68,220
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
SPECIAL REPAIR TO BLDG NO P 15 (OTM ACCN) OF 23 PARA AT MP LINES UNDER GE (EAST) AGRA
2021_MES_483803_1
9391/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹68,220
Yes
7 Jan 2022
25 Oct 2021
8 Dec 2021
25 Oct 2021
29 Nov 2021
8 Nov 2021
60 days
Amount
Taking down of plaster from wall/ celing and soffits of chajja etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed.
Material & labour for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) surfaces finished even and fair faces complete all as specified and directed.
M&L for rendering 15 mm thick on smoothfaces of brick work or concrete surfaces in CM1:4 mixed with using water proofing compound @ 3% by weight of cement finished even and smooth complete all as specified and directed.
Supply only liquid water proofing compound.
Material & labour 10mm thick rendering in CM 1:3 concrete surfaces of ceiling etc, finished surfaced even & smooth with out using extra cement complete all as specified & directed.
M&L for 20 mm thick cement plaster (on roof projection, chajja's, ceiling etc.) in CM(1:3) in two coat each 10 mm thick finished even and smooth without using extra cement complete all as specified and directed
M&L for application on ceiling surfaces and roof projections with two coats of cement based polymer modified bonding slurry made of cement and polymer (Resikon 400) in ratio (1:6) by weight mixed in water to the brushable consistency @ 1.50 kg slurry in two coats such that first coat applied after wetting the surface and the second coat to be applied 15-20 minutes after the application of first coat complete all as per manufacturer's instructions.
Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash to match the existing as required, complete all as specified & directed.
M & L for preparation of new plastered surfaces of wall and applying 2 coats of OBD over one coat of primer complete all as specified and directed.
Material & labour for preparation of new plastered surfaces of wall and applying three coats of white wash to match the existing as required, complete all as specified & directed.
M & L for two coat of cement base paint on new plastered surfaces of wall over one coat of alkali resistant primer including preparation of surfaces complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces at any hight (n. Exc 8m) incl necessary scaffolding/ centering etc complete all as specified and directed.
M&L for complete removal of existing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and applying two coats of oil bound distamper over a coat of primer complete all as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of ceiling including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply two coats of white wash complete all as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of wall including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply two coat of white wash complete as specified and directed.
M&L for complete removal of existing old plastered or unplastered surfaces of wall including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for complete removal of existing old plastered or unplastered surfaces of ceiling including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply two coat of cement base paint over a coat of primer at any hight (n. Exc 8m) incl necessary scaffolding/ centering etc complete all as specified and directed.
Roughening surfaces of old concrete floor/brick wall by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring over 20mm thick cement screed bed in CM 1:6 , lade and jointed with grey cement slurry mixed with pigment to match the shade of stone slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed.
All as per Item No. 19 above but in skirting over 10mm thick rendring in CM 1:4 .
Dismantling floor, hearth wall tiling including cement mortar bedding (but not backing) including rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles (Premium quality) (squre/ rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for glazed ceramic coloured tiles (Premium quality) of size 450x350x7mm thick fixed over and including 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected.
Taking up or down steel tubing and connections of walls, ceiling, floor etc of 15mm bore complete all as specified & directed.
Taking up or down steel tubing and connections of walls, ceiling, floor etc of 20 mm bore complete all as specified & directed.
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, confirming to IS 1239 complete all as specified and directed.
S&F 20 mm dia tubes medium galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, confirming to IS 1239 complete all as specified and directed.
S&F in repairs CP over head shower rose of dia n. exc 125 mm, fancy type with arm and wall flange complete all as specified and drected.
S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, along with cast iron spun 'P' or 'S' trap, integral foot rests including flush pipe, inlcuding taking out of old unserviceable connections etc and connecting up new complete all as specified and directed by the Engineer-in-charge
Supply & fixing in repairs PVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes complete all as specified and directed.
Supply & fixing PVC connections of 450mm long of Make suitable for 15mm dia iron pipe incl PTMT nuts complete all as specified & directed.
Supplied and fixed in repair vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, CP waste coupling, complete all as specified & directed.
Supply & fixing of CP tubular towel rail, 60 cm long, 20mm bore, chromium plated complete all as specified & directed.
Diamantiling water tanks upto 1000 ltr capacity complete all as specified and directed.
Supply & fixing three layered rotational moulded polyethylene water storage tanks 1000 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings all as specified including dismantling existing water tanks complete all as specified & directed.
S & F in ball valve high pressure high pressure of PTMT withepoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (20mm bore dia of pipe ) complete all as specified and directed.
S&F in repair stop valve cast copper alloy high pressure fancy type chromium plated with long shank and cup (concealed type) 15mm dia as fixed in repair complete all as specified and directed.
Supply and fixed in repair angle stop valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed.
Supply & fix in repairs pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, complete all as specified & directed.
Supply & fixing in repair fancy type bib taps cast copper alloy chromium plated with long shank, crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, fixed in repairs complete all as specified & directed.
S & F in repair cast iron spun floor trap with grating (Diameter of outlet 75mm) including jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1) mixed with pedilite water proofing liquid @ 200ml in 50 kg cement, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S & F steel ventilators with top hung shutter & glazing bars hinges, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
S & F steel windows with side hung shutters using steel section with glazing bars including projected box type hinge, steel handle, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
S & F steel windows with side hung shutters using steel section without glazing bars including projected box type hinge, steel handle, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
S & F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Supply & fix galvanized mild steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified & directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing withoil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed. (Make :- Saint Gobin, Modi Guard, Asahi)
Description all as per item No 50 above but figured glass,pin head type complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface over 10 cm width or girth including preparation of new or previously untreated steel surfaces complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n. exc 4.00 Sqm each complete all as specified and directed.
M&L for factory made Pressed steel frames 125 x 60 x 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate,etc complete including PCC (1:3:6) type C-0 (using 12.5 mm graded stone aggregate) as in filling hollow portion of frame complete all as specified and directed.
S&F mild steel work for hold fast and similar small articles conforming to Fe 410-0 or Fe 310-0 including MS screws, bolts, including tarring with a coat of tar and sanding complete all as specified and directed.
M&L for providing, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) for embedding hold fasts including necessary form work etc complete all as specified and directed.
S & F Second class hardwood factory made door 35mm thick plain framed, panelled shutter (Two pane) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part I) klin seasoned and chemically pressure treated complete all as specified and directed.
Supply & fix Glazed or skeleton factory made door shutter, 30mm thick of second class hard wood (hollock), open rebated and prepared to receive glass, gauge ( without sash bars) with plain, chamfered or rounded, mitred beads for glass etc , size of members of shutters shall be as specified in SSR Part I, section -8 clause 8.24 (a) complete all as specified & directed.
S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed confirming to IS 1341 complete all as specified and directed.
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L for Aluminium anodised, barrel tower bolts of extruded section and fixed 200mm size complete all as specified and directed.
M&L for Aluminium handles, cast type, anodised 150mm size , complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface over 10 cm width or girth including preparation of new or previously untreated steel surfaces complete all as specified and directed.
Supply & fix solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes complete all as specified & directed. (Make:- Rajshree Plastiwood/Sintex/ Polyline).
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 174 of SSR 2020 (Part-II). (Make:- Rajshree Plastiwood/Sintex/ Polyline).
S&F 150 mm long Aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F in repair 25mm dia PVC coated metalic fancy type of approved finish curtain rod incl. brackets and fancy type end knobs, rings etc complete all as specified and directed.
S & F floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with lead joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with lead joints laid in trenches including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 75 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with lead joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and jointed with lead joint including making good disturbe portion to match the existing complete all as specified and directed.
S&F in repairs 75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed.
S&F of Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P' Size of gully traps 150x100 mm complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar incl all quoins, arches, pillars etc, complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size brick, straight curved on plan exc 6m mean radius built in cm (1:6) using old size bricks complete all as specified and directed.
M&L for providing pre-cast RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover (for manholes and drains) including necessary form work set in CM 1:4 with and including demolition complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately)
S&F MS TMT bars 10 mm dia and above cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Dismantling of polymeric water proofing membrane single layer with plaster on roofs complete including removal of material and debris away from the site etc complete all as specified and directed.
Demolition of concrete in any description and in any position (unreinforced) complete all as specified and directed.
Material and labour plain cement concrete type B-0, 1:2:4 (12.50mm graded aggregate) 25mm thick as in sub floor, sub base, padding etc including chicken wire mesh sandwich with two layer complete all as specified and directed.
Material and labour for applying 10 mm thick average plaster in CM 1:4 including water proofing compound @ 2% by weight of cement. ( Make of WPC - Pidilite, water Seal acro paints,snowem ,and other Make approved by GE)
Material and labour for water proofing treatment of roof slab all as specified below. (Note - Each stage passed by GE/Engr-In-Charge)
Preparation of plaster surface roof by brushing and cleaning .
Applying a priming coat with bitumen primer @0.5 Kg/Sqm. ( Make - Bangal Bitumen and other Make approved by GE)
Applying tack coat of hot blown industrial bitumen grade 85/25 @ 1.20Kg per sqm ( Make - Bangal Bitumen and other Make approved by GE)
Supply & laying 3 mm thick APP based polymeric membrane with mineral finished on top minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid by torch application over primed surface & the overlap shall be of minimum 75mm on longitudional direction and 100 mm on transverse dirrection complete all as per manufacturers's instruction.”( Make - Bangal Bitumen, STP,IWL India Ltd and other Make approved by GE)
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C- 2, (using 40mm graded stone aggregate) as in hard standing and plinth protection etc, finished even and smooth with out using extra cement complete all as specified and directed.
M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M & L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in north light curve /cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and modular sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Havells/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light point or one fan point controlled by one switch
One 3 pin socket outlet 5 amps on the same board with other switches
One 5 pin socket outlet 5/6 Amps on independent board
All as per item No 92 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FR PVC insulated sheathed cable with FR PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board/600 sqmm wall fan.
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate bodycomplete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supply and fix ceiling rose , PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed. Make : Havells/Cona/Plaza/Legrand
Supplying and fixing 20 watt LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly pre-wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting, complete all as specified and directed. Make :- Wipro Model No D532065 or equivalent model/ make of Wipro/CG
Supply and fix Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed. Make : Bajaj/Havells/Wipro/Philips
Dismantling, taking down exisitng ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Dismantling, taking down exisitng exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/Havells/Hager
Supply & fix in repair sheet metal enclosure MCB distribution board. triple pole & neutral 415 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all as specified and directed. Make : Legrand/Schneider/Havells/Hager
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/Havells/Hager
Supply and fix in repair MCB isolator four pole 415 volts any rating 100 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables complete all as specified and directed. Make : Legrand/Schneider/Havells/Hager .
Supply and fixing in repair MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make : Legrand/Schneider/Havells/Hager
Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make : Legrand/Schneider/Havells/Hager
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x2.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in PVC Conduit not less than 20 mm dia including dismantling of old unsv submain wiring complete all as specified and directed..Make Polycab/Havells/RR Kablel/Grandlay
Materials and labour as in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and lay in repair/replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 Core, including dismantling of Old Unsv cable Complete all as specified and directed. Make : Havells/Polycab/Grandlay
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Supply and lay in replacement GI tube light grade 40 size as in cable protection pipe including all fittings complete all as specified and directed. Make Jindal/Prakash/Surya/Bansal
FURNITURE POINT
M/s Himgiri construction
M/S RISHI RAJ AGRAWAL
N.K. ENTERPRISES
SahaDevSingh Constructions
SHRANGI RISHI CONSTRUCTION
MOHAN LAL GUPTA
MNR ASSOCIATES
M/s S. K. Construction Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .